AWAvinash S. Welankiwar

Avinash S. Welankiwar

*This is an algorithmically generated author record based on publicly available information.

Avinash S. Welankiwar has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Phase dispersion index based fault detection and classification method in transmission lines connecting AC Microgrids

    by Avinash Welankiwar, Rajesh Sharma, Bhupendra Kumar

    Conventional magnitude-based protection techniques are no longer dependable due to the substantial changes in fault current characteristics induced from inverter-interfaced distributed generation in AC microgrids. The Phase Dispersion Index based fault detection and classification technique for transmission lines connecting AC microgrids is presented in this study. The proposed approach uses phase dispersion characteristics of phase currents derived using sliding window technique and Hilbert Huang Transform based signal processing to quantify fault-induced asymmetry through a robust PDI. Self adaptive threshold is used to boost sensitivity of detection. Phase wise measured instantaneous currents from both line ends are only required for computation. While fault classification is carried out utilizing phase-wise persistence and zero sequence current to identify the presence of a ground flag, fault detection is accomplished by tracking the rapid deviation of the PDI with respect to the self-adaptive threshold. Case studies of short circuit faults with variations in DG penetration levels are simulated at line receiving end and 60 km far from receiving end using PSCAD, fault detection and classification is implemented in MATLAB. With a minimal time of detection of 0.6 milliseconds, the proposed technique accurately identifies every simulated fault, confirms speed, precision, and dependable fault detection and classification.

  • MATLAB GUI based Partial Discharge Localization in Power Transformers using UHF Acoustic Method

    by Avinash S. Welankiwar, R. B. Sharma

    Partial Discharge (PD) problem is getting more attention day by day due to its severity towards insulation deterioration and internal arcing problems. In this Paper, PD detection is illustrated with the help of a case study conducted on a Power Transformer by using Ultra High Frequency (UHF) injection and acoustic method combined with High frequency Current Transducer (HFCT) to get more accurate results. This method is getting more popular day by day due to its accuracy in PD detection. This paper represents the mathematical approach of UHF acoustic method for the Localization of PD in MATLAB GUI environment. Field testing is done on 100 MVA 400/220 kV Interconnecting Transformer at 400 kV receiving station and the obtained results are compared with the output of mathematical algorithm in MATLAB software. Results revels the effective visualization of the possible position of the PD in the transformer tank in terms of x, y and z coordinates.