Manuel Armando Mazzoletti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Manuel Armando Mazzoletti has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Guillermo Ruben Bossio
Applied Electronics Group, Faculty of Engineering, National University of Río Cuarto, Río Cuarto, Crdoba, Argentina
14 shared publications - Cristian Hernan De Angelo
National University of Rio Cuarto
6 shared publications Diego R. Espinoza-Trejo
Department of Mechatronics Engineering, Coordinación Académica Región Altiplano, Universidad Autónoma de San Luis Potosí, San Luis Potosí, México
4 shared publications- Pablo Daniel Donolo
Universidad Nacional de Río Cuarto
4 shared publications - Marcos Donolo
Schweitzer Engineering Laboratories, Inc
2 shared publications - Carlos Martin Pezzani
IITEMA, CONICET FI, UNRC, Rio Cuarto, Argentina
1 shared publication
Latest Publications
- 21 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (2) , 1927-1935
Turn to Turn Short-Circuit Fault and High-Resistance Connection Diagnosis for Induction Motor During Start-Up Transient
In this paper, a new method to diagnose turn-to-turn short-circuit faults (TSCFs) and high-resistance connections (HRCs) for soft-starters fed squirrel cage-rotor induction motors (IMs) is proposed. TSCF and HRC faults cause a significant temperature increase if not early detected. TSCFs requires immediate IM shutdown, whereas the effects of HRCs can be monitored over time. Several methods proposed in the literature are based on zero-sequence voltage or negative-sequence current for fault diagnosis. Most of them were applied for steady-state conditions and only consider sinusoidally distributed windings, without including harmonic components. The proposed method is based on monitoring the fifth harmonic current during the start-up transient to separate the effects of TSCFs and HRCs. Two new analytical models with fault considering the h-th harmonic in the supply voltage are proposed. The first IM model incorporates the effects of a TSCF in any of the phase windings, while the second considers an HRC fault. Based on these analytical models, two indicators are proposed to quantify the severity of the faults. Both indicators are defined from the positive-sequence component of the stator current and allow decoupling the effects between the TSCFs and the HRCs. The practical implementation was carried out with a standard soft-starter, without modifying their control algorithm or internal structure. In the experimental tests, an IM with modified windings was used to generate short-circuits between 3 and 10 turns. On the other hand, the HRCs were generated by connecting resistors of different magnitudes in series with a phase winding. The experimental results demonstrated that the positive-sequence current component of the fifth harmonic exhibits different patterns in the presence of a TSCF or an HRC.
- 21 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (2) , 1927-1935
Turn to Turn Short-Circuit Fault and High-Resistance Connection Diagnosis for Induction Motor During Start-Up Transient
In this paper, a new method to diagnose turn-to-turn short-circuit faults (TSCFs) and high-resistance connections (HRCs) for soft-starters fed squirrel cage-rotor induction motors (IMs) is proposed. TSCF and HRC faults cause a significant temperature increase if not early detected. TSCFs requires immediate IM shutdown, whereas the effects of HRCs can be monitored over time. Several methods proposed in the literature are based on zero-sequence voltage or negative-sequence current for fault diagnosis. Most of them were applied for steady-state conditions and only consider sinusoidally distributed windings, without including harmonic components. The proposed method is based on monitoring the fifth harmonic current during the start-up transient to separate the effects of TSCFs and HRCs. Two new analytical models with fault considering the h-th harmonic in the supply voltage are proposed. The first IM model incorporates the effects of a TSCF in any of the phase windings, while the second considers an HRC fault. Based on these analytical models, two indicators are proposed to quantify the severity of the faults. Both indicators are defined from the positive-sequence component of the stator current and allow decoupling the effects between the TSCFs and the HRCs. The practical implementation was carried out with a standard soft-starter, without modifying their control algorithm or internal structure. In the experimental tests, an IM with modified windings was used to generate short-circuits between 3 and 10 turns. On the other hand, the HRCs were generated by connecting resistors of different magnitudes in series with a phase winding. The experimental results demonstrated that the positive-sequence current component of the fifth harmonic exhibits different patterns in the presence of a TSCF or an HRC.
- Open Access
- 1 August 2023
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 13 (4) , 3593-3605
Online detection of interturn short-circuit fault in induction motor based on 5th harmonic current tracking using Vold-Kalman filter
In this paper we propose a strategy for real-time detection of interturn short-circuit faults (ISCF) on three-phase induction motor (IM) by using a Vold-Kalman filter (VKF) algorithm. ISCF produce a thermal stress into the stator winding due to large current that flows through the short-circuited turns. Therefore, incipient fault detection is required in order to avoid catastrophic failures such as phase to phase, or phase to ground faults. The strategy is based on an analytical IM model that includes a ISCF fault in any of the phase windings and considering the h-th harmonic in the voltage supply. Based on equivalent electrical circuits with harmonics in sequence components, we propose a strategy for detection of an ISCF on IM by tracking the 5th harmonic current component using a VKF algorithm. The proposed model is experimentally validated using a three-phase IM with modified stator windings to generate ISCF. Also, the IM is feeded by a programmable voltage source to synthesize distorted voltage supply with the 5th harmonic. The results demonstrated that the positive-sequence magnitude for the 5th harmonic current component is a good indicator of the fault severity once it exceeds a threshold limit value, even under load variations and unbalanced voltages.
- 1 August 2023
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 13 (4) , 3593-3605
Open AccessOnline detection of interturn short-circuit fault in induction motor based on 5th harmonic current tracking using Vold-Kalman filter
In this paper we propose a strategy for real-time detection of interturn short-circuit faults (ISCF) on three-phase induction motor (IM) by using a Vold-Kalman filter (VKF) algorithm. ISCF produce a thermal stress into the stator winding due to large current that flows through the short-circuited turns. Therefore, incipient fault detection is required in order to avoid catastrophic failures such as phase to phase, or phase to ground faults. The strategy is based on an analytical IM model that includes a ISCF fault in any of the phase windings and considering the h-th harmonic in the voltage supply. Based on equivalent electrical circuits with harmonics in sequence components, we propose a strategy for detection of an ISCF on IM by tracking the 5th harmonic current component using a VKF algorithm. The proposed model is experimentally validated using a three-phase IM with modified stator windings to generate ISCF. Also, the IM is feeded by a programmable voltage source to synthesize distorted voltage supply with the 5th harmonic. The results demonstrated that the positive-sequence magnitude for the 5th harmonic current component is a good indicator of the fault severity once it exceeds a threshold limit value, even under load variations and unbalanced voltages.
- 8 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 19 (5) , 726-734
Stator Faults Detection on Induction Motors Using Harmonic Sequence Current Components Analysis
In this paper we propose a strategy for detecting interturn short circuits on stator windings of three-phase induction motors (IM). The strategy is based on an analytical model that includes a stator fault in any of the phase windings considering the h-th harmonic in the supply voltage. To find the adequate model, we propose an equivalent electrical circuit of the IM in steady state, considering each sequence component. The proposed strategy allows the detection of an interturn short-circuit fault by monitoring the fifth-order harmonic component. We present simulation and experimental results for the faulty IM and different operating conditions. In the laboratory tests, we use a programmable power supply in order to synthesize distorted and unbalance voltages. Also, the windings of a three-phase IM have been modified to generate stator faults and validate the proposed model. The results show that the sustained increase of the fifth-order harmonic of positive-sequence current is a good indicator of the fault severity.
- 8 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 19 (5) , 726-734
Stator Faults Detection on Induction Motors Using Harmonic Sequence Current Components Analysis
In this paper we propose a strategy for detecting interturn short circuits on stator windings of three-phase induction motors (IM). The strategy is based on an analytical model that includes a stator fault in any of the phase windings considering the h-th harmonic in the supply voltage. To find the adequate model, we propose an equivalent electrical circuit of the IM in steady state, considering each sequence component. The proposed strategy allows the detection of an interturn short-circuit fault by monitoring the fifth-order harmonic component. We present simulation and experimental results for the faulty IM and different operating conditions. In the laboratory tests, we use a programmable power supply in order to synthesize distorted and unbalance voltages. Also, the windings of a three-phase IM have been modified to generate stator faults and validate the proposed model. The results show that the sustained increase of the fifth-order harmonic of positive-sequence current is a good indicator of the fault severity.
- 1 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Fault Diagnosis in PMSM with Partitioned Stator Windings−Part I: Experimental Validation with Static Eccentricity
A signal-based strategy for static eccentricity (SE) detection in permanent magnet synchronous machines (PMSM) is proposed in this work. The effects of SE are analyzed from a model developed using a finite element method (FEM). SE detection is realized by evaluating the residual voltages (RV) obtained from the midpoint voltages measured in the middle of the windings of each phase. Unlike the methods based on motor current or voltage signature analysis (MCSA/MVSA), RVs allow to detect only the effects of an SE against other external problems that are usually found in industrial applications. Experimental laboratory results are presented which were obtained using bearings with eccentric bushings to generate different degrees of SE in the PMSM. The proposed strategy is validated by comparing the results obtained by FEM with the experimental tests for PMSM in different operating conditions, guaranteeing the correct diagnosis of SE.
- 1 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Fault Diagnosis in PMSM with Partitioned Stator Windings−Part I: Experimental Validation with Static Eccentricity
A signal-based strategy for static eccentricity (SE) detection in permanent magnet synchronous machines (PMSM) is proposed in this work. The effects of SE are analyzed from a model developed using a finite element method (FEM). SE detection is realized by evaluating the residual voltages (RV) obtained from the midpoint voltages measured in the middle of the windings of each phase. Unlike the methods based on motor current or voltage signature analysis (MCSA/MVSA), RVs allow to detect only the effects of an SE against other external problems that are usually found in industrial applications. Experimental laboratory results are presented which were obtained using bearings with eccentric bushings to generate different degrees of SE in the PMSM. The proposed strategy is validated by comparing the results obtained by FEM with the experimental tests for PMSM in different operating conditions, guaranteeing the correct diagnosis of SE.
- Open Access
- 8 September 2020
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 14 (12) , 2301-2311
Interturn short‐circuit fault diagnosis in PMSM with partitioned stator windings
A new signal‐based strategy for stator winding interturn short‐circuit fault detection and isolation in permanent magnet synchronous machines (PMSM) is proposed. The strategy is based on an analysis of the midpoint voltage of the phase windings. A PMSM model with partitioned stator windings including an interturn short‐circuit fault is presented. Unlike the motor current signature analysis methods, the midpoint voltage measurement allows detecting an incipient stator fault even under external disturbances without false alarms. For PMSM generators used in variable‐speed wind turbines, the random changes of wind produce fluctuations in the rotor speed. In this situation, conventional fault detection methods used for the steady‐state condition may produce errors in the fault diagnosis. However, the proposed strategy is capable of rejecting the effects of the non‐stationary speed conditions by resampling the voltage signals at fixed increments of the rotor angular position. Several experimental results in time and frequency‐domain are presented for different speed conditions using a PMSM with modified stator winding.
- 8 September 2020
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 14 (12) , 2301-2311
Open AccessInterturn short‐circuit fault diagnosis in PMSM with partitioned stator windings
A new signal‐based strategy for stator winding interturn short‐circuit fault detection and isolation in permanent magnet synchronous machines (PMSM) is proposed. The strategy is based on an analysis of the midpoint voltage of the phase windings. A PMSM model with partitioned stator windings including an interturn short‐circuit fault is presented. Unlike the motor current signature analysis methods, the midpoint voltage measurement allows detecting an incipient stator fault even under external disturbances without false alarms. For PMSM generators used in variable‐speed wind turbines, the random changes of wind produce fluctuations in the rotor speed. In this situation, conventional fault detection methods used for the steady‐state condition may produce errors in the fault diagnosis. However, the proposed strategy is capable of rejecting the effects of the non‐stationary speed conditions by resampling the voltage signals at fixed increments of the rotor angular position. Several experimental results in time and frequency‐domain are presented for different speed conditions using a PMSM with modified stator winding.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Steady-State Induction Machine Model with Turn Faults and Voltage Harmonics
A model of the Induction Machine (IM) considering the harmonics of the power supply network is presented in this paper. Unlike previous models that consider the effect only on the fundamental frequency component, the proposed model allows to evaluate the effect of an interturn short-circuit faults on the harmonic components. This is very useful for the development of the fault diagnostic strategies capable of isolating the stator faults of other usual disturbances in the industrial applications, such as the unbalance or distortion of the power supply voltage or the high-resistance connection, among others. The steady-state IM equivalent circuits with stator fault derived from the dynamic model in qd reference frame are presented. Finally, the behavior of the proposed model for different fault conditions and IM operations are analyzed by simulation results.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Steady-State Induction Machine Model with Turn Faults and Voltage Harmonics
A model of the Induction Machine (IM) considering the harmonics of the power supply network is presented in this paper. Unlike previous models that consider the effect only on the fundamental frequency component, the proposed model allows to evaluate the effect of an interturn short-circuit faults on the harmonic components. This is very useful for the development of the fault diagnostic strategies capable of isolating the stator faults of other usual disturbances in the industrial applications, such as the unbalance or distortion of the power supply voltage or the high-resistance connection, among others. The steady-state IM equivalent circuits with stator fault derived from the dynamic model in qd reference frame are presented. Finally, the behavior of the proposed model for different fault conditions and IM operations are analyzed by simulation results.
- Top Cited Papers
- 29 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 64 (9) , 7218-7228
A Model-Based Strategy for Interturn Short-Circuit Fault Diagnosis in PMSM
A model-based method for interturn short-circuit fault detection and isolation in permanent magnet synchronous machines (PMSMs) is proposed in this paper. The fault detection is realized based on a residual current vector (RCV) generated by the difference between the measured stator currents and the stator currents estimated by a state observer. In order to avoid false alarms due to possible undesired perturbations, the sequence decomposition of the RCV is performed by employing different reference-frames. Thus, the proposed RCV allows the correct detection of interturn short-circuit faults and quantification of the fault severity in any faulty stator-phase winding. Moreover, since the back-EMF generated by the magnets is proportional to the rotor shaft speed, the electrical angular speed is estimated through the stator voltages measurement, without using a speed sensor. Simulation results from the three-phase PMSM dynamic model that allows considering the interturn short-circuit fault in any stator phase-windings are presented. The proposed method is validated using a three-phase PMSM prototype with modified stator windings. The robustness and the reliability of the proposal was tested for several interturn fault conditions under transient conditions including different disturbances.
- 29 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 64 (9) , 7218-7228
Top Cited PapersA Model-Based Strategy for Interturn Short-Circuit Fault Diagnosis in PMSM
A model-based method for interturn short-circuit fault detection and isolation in permanent magnet synchronous machines (PMSMs) is proposed in this paper. The fault detection is realized based on a residual current vector (RCV) generated by the difference between the measured stator currents and the stator currents estimated by a state observer. In order to avoid false alarms due to possible undesired perturbations, the sequence decomposition of the RCV is performed by employing different reference-frames. Thus, the proposed RCV allows the correct detection of interturn short-circuit faults and quantification of the fault severity in any faulty stator-phase winding. Moreover, since the back-EMF generated by the magnets is proportional to the rotor shaft speed, the electrical angular speed is estimated through the stator voltages measurement, without using a speed sensor. Simulation results from the three-phase PMSM dynamic model that allows considering the interturn short-circuit fault in any stator phase-windings are presented. The proposed method is validated using a three-phase PMSM prototype with modified stator windings. The robustness and the reliability of the proposal was tested for several interturn fault conditions under transient conditions including different disturbances.