Daniar Fahmi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Daniar Fahmi has a total of 129 co-authors. Here are the top co-authors by number of shared publications:
- Yulistya Negara
Department of Electrical Engineering, Institut Teknologi Sepuluh Nopember, Surabaya, Indonesia
51 shared publications - Dimas Anton Asfani
Department of Electrical Engineering, Institut Teknologi Sepuluh Nopember, Surabaya, Indonesia
47 shared publications - I. Gusti Ngurah Satriyadi Hernanda
Institut Teknologi Sepuluh Nopember,Department of Electrical Engineering,Surabaya,Indonesia
19 shared publications Mochammad Wahyudi
Electrical and Information Engineering Department, Universitas Gadjah Mada
16 shared publications- Hazlee Azil Illias
Universiti Malaya
8 shared publications Dimas Anton Asfani
6 shared publications
Latest Publications
- Open Access
- 23 September 2026
- Published byĀ ElsevierĀ inĀ Results in Engineering
- Vol.Ā 32
Study of the selection of an individual grounding location point against direct lightning strikes on solar panel systems
- 23 September 2026
- Published byĀ ElsevierĀ inĀ Results in Engineering
- Vol.Ā 32
Open AccessStudy of the selection of an individual grounding location point against direct lightning strikes on solar panel systems
- 18 June 2026
- Published byĀ ElsevierĀ inĀ Electric Power Systems Research
- Vol.Ā 261
Sistematical evaluation of digital wavelet filter selection for identification system, case study: DC arcing detection system
- 18 June 2026
- Published byĀ ElsevierĀ inĀ Electric Power Systems Research
- Vol.Ā 261
Sistematical evaluation of digital wavelet filter selection for identification system, case study: DC arcing detection system
- 9 June 2026
- Published byĀ Institute of Electrical and Electronics Engineers (IEEE)Ā inĀ IEEE Transactions on Dielectrics and Electrical Insulation
- Vol.Ā PP Ā (10709878) , 1
Partial Discharge Characteristic of Cellulose-Contaminated Synthetic Ester-Based Nanofluid under Dynamic Flow and Non-Uniform Electric Field Conditions
This study investigates the characteristics of Partial Discharge (PD) in synthetic ester-based nanofluids contaminated with cellulose particles at various concentrations (0, 0.5, and 1 g/L) and circulation velocities (0, 0.3, and 0.5 m/s). The base oil is filtered, dried, and degassed, while cellulose and TiO2 nanoparticles (anatase phase, 30 nm average diameter, 0.01 wt%) are dried to prevent agglomeration. Nanofluids are produced using a two-step method to ensure their stability. A custom system with a DC pump and flow sensors regulates oil flow, and PD tests are performed in a plexiglass chamber using needle-plane electrodes featuring variations in tip geometry (needle, square, blunt) to measure Partial Discharge Inception Voltage (PDIV) and Phase-Resolved Partial Discharge (PRPD) patterns. Results show that PDIV decreases with higher cellulose concentration but increases with faster circulation. Blunt electrodes yield the highest PDIV, followed by square and needle tips. PRPD analysis reveals that higher cellulose concentrations increase the PD activity and cause the cluster density to spread. Conversely, an increase in the circulation velocity reduces the PD activity and shifts the cluster to the left with a more dispersed density. The order of the PD activity based on the electrode configuration is needle, square, and blunt. The obtained PRPD patterns demonstrate a dominant positive cycle associated with PD activity owing to the non-uniform electric field. This study provides insights into the effects of cellulose contamination and dynamic conditions on the performance of synthetic ester nanofluid insulation under non-uniform electric fields.
- 9 June 2026
- Published byĀ Institute of Electrical and Electronics Engineers (IEEE)Ā inĀ IEEE Transactions on Dielectrics and Electrical Insulation
- Vol.Ā PP Ā (10709878) , 1
Partial Discharge Characteristic of Cellulose-Contaminated Synthetic Ester-Based Nanofluid under Dynamic Flow and Non-Uniform Electric Field Conditions
This study investigates the characteristics of Partial Discharge (PD) in synthetic ester-based nanofluids contaminated with cellulose particles at various concentrations (0, 0.5, and 1 g/L) and circulation velocities (0, 0.3, and 0.5 m/s). The base oil is filtered, dried, and degassed, while cellulose and TiO2 nanoparticles (anatase phase, 30 nm average diameter, 0.01 wt%) are dried to prevent agglomeration. Nanofluids are produced using a two-step method to ensure their stability. A custom system with a DC pump and flow sensors regulates oil flow, and PD tests are performed in a plexiglass chamber using needle-plane electrodes featuring variations in tip geometry (needle, square, blunt) to measure Partial Discharge Inception Voltage (PDIV) and Phase-Resolved Partial Discharge (PRPD) patterns. Results show that PDIV decreases with higher cellulose concentration but increases with faster circulation. Blunt electrodes yield the highest PDIV, followed by square and needle tips. PRPD analysis reveals that higher cellulose concentrations increase the PD activity and cause the cluster density to spread. Conversely, an increase in the circulation velocity reduces the PD activity and shifts the cluster to the left with a more dispersed density. The order of the PD activity based on the electrode configuration is needle, square, and blunt. The obtained PRPD patterns demonstrate a dominant positive cycle associated with PD activity owing to the non-uniform electric field. This study provides insights into the effects of cellulose contamination and dynamic conditions on the performance of synthetic ester nanofluid insulation under non-uniform electric fields.
- 16 September 2025
- Published byĀ ElsevierĀ inĀ Electric Power Systems Research
- Vol.Ā 251
Impact of cellulose contamination and flow velocity on dielectric properties of synthetic ester-based nanofluid
- 16 September 2025
- Published byĀ ElsevierĀ inĀ Electric Power Systems Research
- Vol.Ā 251
Impact of cellulose contamination and flow velocity on dielectric properties of synthetic ester-based nanofluid
- Open Access
- 2 August 2025
- Published byĀ Engineering, Technology & Applied Science ResearchĀ inĀ Engineering, Technology & Applied Science Research
- Vol.Ā 15 Ā (4) , 24585-24593
Broken Rotor Bar Fault Detection and Severity Identification in Squirrel Cage Induction Motor Using Empirical Mode Decomposition and Artificial Neural Networks
The broken rotor bar is the fault that most often occurs in induction motors. This paper proposes a method to identify the broken rotor bar fault using a combination of Empirical Mode Decomposition and Artificial Neural Networks (ANNs). The motor current signal is processed using EMD analysis resulting in the Intrinsic Mode Function (IMF) signal. The zero crossing point of the IMF signal is recorded to obtain the Time Successive between Zero Crossing (TSZC). The Probability Density Function (PDF) of the TZSC is used as the ANN classifier input. The PDF properties of peak, width, and standard deviation are selected as the input variables. Two ANNs were designed as fault detection and severity identification systems. The experimental testing also considers the load level variation. The experiment of the broken rotor bar fault diagnostics shows that the ANN-based fault detection system is able to detect faults with accuracy up to 94.2%. Moreover, the ANN-based severity identification successfully identified 76.09% of the cases. In addition, the experiment on load variations reveals that the fault diagnostic is more effective at higher loads.
- 2 August 2025
- Published byĀ Engineering, Technology & Applied Science ResearchĀ inĀ Engineering, Technology & Applied Science Research
- Vol.Ā 15 Ā (4) , 24585-24593
Open AccessBroken Rotor Bar Fault Detection and Severity Identification in Squirrel Cage Induction Motor Using Empirical Mode Decomposition and Artificial Neural Networks
The broken rotor bar is the fault that most often occurs in induction motors. This paper proposes a method to identify the broken rotor bar fault using a combination of Empirical Mode Decomposition and Artificial Neural Networks (ANNs). The motor current signal is processed using EMD analysis resulting in the Intrinsic Mode Function (IMF) signal. The zero crossing point of the IMF signal is recorded to obtain the Time Successive between Zero Crossing (TSZC). The Probability Density Function (PDF) of the TZSC is used as the ANN classifier input. The PDF properties of peak, width, and standard deviation are selected as the input variables. Two ANNs were designed as fault detection and severity identification systems. The experimental testing also considers the load level variation. The experiment of the broken rotor bar fault diagnostics shows that the ANN-based fault detection system is able to detect faults with accuracy up to 94.2%. Moreover, the ANN-based severity identification successfully identified 76.09% of the cases. In addition, the experiment on load variations reveals that the fault diagnostic is more effective at higher loads.
- Open Access
- 1 August 2025
- Published byĀ Lembaga Penelitian dan Pengabdian kepada Masyarakat ITSĀ inĀ JAREE (Journal on Advanced Research in Electrical Engineering)
- Vol.Ā 9 Ā (2)
Optimal Variable Speed Control of BLDC Diesel Generator to Enhance Fuel Efficiency
The growing adoption of renewable energy technologies still faces challenges such as instability, intermittent, and limited energy storage capacity. Diesel engine generators, known for their stability and reliability, remain essential as primary or backup power sources, especially in remote areas. However, conventional diesel generators operating at constant speed are inefficient in fuel consumption and produce high emissions. This study investigates the implementation of a variable-speed diesel generator system using a BLDC (Brushless Direct Current) generator controlled by a fuzzy logic-based controller (FLC). The proposed system adjusts engine speed and the duty cycle of the converter to optimize fuel efficiency while maintaining voltage and frequency stability. Simulation results demonstrate that the system reduces fuel consumption by up to 7.6% (0.86 liters/hour) for a 100 kW generator. Additionally, the FLC effectively stabilizes voltage and frequency during load changes and finally enhancing overall system performance.
- 1 August 2025
- Published byĀ Lembaga Penelitian dan Pengabdian kepada Masyarakat ITSĀ inĀ JAREE (Journal on Advanced Research in Electrical Engineering)
- Vol.Ā 9 Ā (2)
Open AccessOptimal Variable Speed Control of BLDC Diesel Generator to Enhance Fuel Efficiency
The growing adoption of renewable energy technologies still faces challenges such as instability, intermittent, and limited energy storage capacity. Diesel engine generators, known for their stability and reliability, remain essential as primary or backup power sources, especially in remote areas. However, conventional diesel generators operating at constant speed are inefficient in fuel consumption and produce high emissions. This study investigates the implementation of a variable-speed diesel generator system using a BLDC (Brushless Direct Current) generator controlled by a fuzzy logic-based controller (FLC). The proposed system adjusts engine speed and the duty cycle of the converter to optimize fuel efficiency while maintaining voltage and frequency stability. Simulation results demonstrate that the system reduces fuel consumption by up to 7.6% (0.86 liters/hour) for a 100 kW generator. Additionally, the FLC effectively stabilizes voltage and frequency during load changes and finally enhancing overall system performance.
- 6 June 2025
- Published byĀ Institute of Electrical and Electronics Engineers (IEEE)Ā inĀ IEEE Transactions on Dielectrics and Electrical Insulation
- Vol.Ā 32 Ā (6) , 3419-3427
Cellulose Movement Characteristics in Circulated Synthetic Ester Oil-Based Nanofluids Under AC Voltage
This study investigates the impact of the cellulose movement characteristics on the dielectric properties of circulated synthetic ester oil-based nanofluids. Finite Element Method (FEM) simulations are employed to analyze the accumulation and trajectory behavior of cellulose particles. The results show that TiO2 nanoparticle addition limits particle accumulation by capturing cellulose, and the circulation velocity created drag forces that hinder conductive bridge formation. This results in more linear movement of cellulose particles, allowing for quicker transit through the charged region between electrodes, while nanoparticles also promote a flattener trajectory for cellulose. The experimental data validates the simulation result, revealing a linear relationship, demonstrating that the breakdown voltage diminishes as cellulose concentration rises, making it easier for the conductive bridge to form. Conversely, the introduction of nanoparticles and an increase in circulation velocity yield an opposing effect.
- 6 June 2025
- Published byĀ Institute of Electrical and Electronics Engineers (IEEE)Ā inĀ IEEE Transactions on Dielectrics and Electrical Insulation
- Vol.Ā 32 Ā (6) , 3419-3427
Cellulose Movement Characteristics in Circulated Synthetic Ester Oil-Based Nanofluids Under AC Voltage
This study investigates the impact of the cellulose movement characteristics on the dielectric properties of circulated synthetic ester oil-based nanofluids. Finite Element Method (FEM) simulations are employed to analyze the accumulation and trajectory behavior of cellulose particles. The results show that TiO2 nanoparticle addition limits particle accumulation by capturing cellulose, and the circulation velocity created drag forces that hinder conductive bridge formation. This results in more linear movement of cellulose particles, allowing for quicker transit through the charged region between electrodes, while nanoparticles also promote a flattener trajectory for cellulose. The experimental data validates the simulation result, revealing a linear relationship, demonstrating that the breakdown voltage diminishes as cellulose concentration rises, making it easier for the conductive bridge to form. Conversely, the introduction of nanoparticles and an increase in circulation velocity yield an opposing effect.
- Open Access
- 1 February 2025
- Published byĀ Institute of Advanced Engineering and ScienceĀ inĀ International Journal of Electrical and Computer Engineering (IJECE)
- Vol.Ā 15 Ā (1) , 56-66
Influence of metal particles shape on direct current voltage electric properties of nanofluids
It is widely recognized that the application of nanoparticles has the potential to improve the dielectric properties of transformer oil. Nevertheless, there is a scarcity of studies that have utilized pure nanofluids, and in practical applications, it is inevitable for transformer oil to become contaminated. Therefore, this study conducted tests to investigate how the shape and size of metal contaminants impact the dielectric performance of Fe3O4 nanofluids. The findings from the levitation voltage test indicate that as the size and diameter of the particle increase, the levitation voltage value measured also increases, and conversely. Moreover, a higher concentration of nanoparticles leads to a higher measured levitation voltage value. On the other hand, the breakdown voltage test results demonstrate that larger and sharper particles result in lower measured breakdown voltage values, and vice versa. The simulation outcomes regarding electric field distribution reveal that larger and sharper particles correspond to higher measured electric field values, while the opposite is true for smaller and less sharp particles.
- 1 February 2025
- Published byĀ Institute of Advanced Engineering and ScienceĀ inĀ International Journal of Electrical and Computer Engineering (IJECE)
- Vol.Ā 15 Ā (1) , 56-66
Open AccessInfluence of metal particles shape on direct current voltage electric properties of nanofluids
It is widely recognized that the application of nanoparticles has the potential to improve the dielectric properties of transformer oil. Nevertheless, there is a scarcity of studies that have utilized pure nanofluids, and in practical applications, it is inevitable for transformer oil to become contaminated. Therefore, this study conducted tests to investigate how the shape and size of metal contaminants impact the dielectric performance of Fe3O4 nanofluids. The findings from the levitation voltage test indicate that as the size and diameter of the particle increase, the levitation voltage value measured also increases, and conversely. Moreover, a higher concentration of nanoparticles leads to a higher measured levitation voltage value. On the other hand, the breakdown voltage test results demonstrate that larger and sharper particles result in lower measured breakdown voltage values, and vice versa. The simulation outcomes regarding electric field distribution reveal that larger and sharper particles correspond to higher measured electric field values, while the opposite is true for smaller and less sharp particles.