    Study of the selection of an individual grounding location point against direct lightning strikes on solar panel systems

    by Dimas Anton Asfani, I. Gusti Ngurah Satriyadi Hernanda, I. Made Yulistya Negara, Daniar Fahmi, Muhammad Robich Mumtazy, Alya Maharani, Syafaruddin, Istiyo Winarno

  • Open Access

    Influence of metal particles shape on direct current voltage electric properties of nanofluids

    by Daniar Fahmi, Muhammad Fadlan Akbar, I Made Yulistya Negara, I Gusti Ngurah Satriyadi Hernanda, Dimas Anton Asfani, Risyad Alauddin Zaidan, Arkan Fadhilah

    It is widely recognized that the application of nanoparticles has the potential to improve the dielectric properties of transformer oil. Nevertheless, there is a scarcity of studies that have utilized pure nanofluids, and in practical applications, it is inevitable for transformer oil to become contaminated. Therefore, this study conducted tests to investigate how the shape and size of metal contaminants impact the dielectric performance of Fe3O4 nanofluids. The findings from the levitation voltage test indicate that as the size and diameter of the particle increase, the levitation voltage value measured also increases, and conversely. Moreover, a higher concentration of nanoparticles leads to a higher measured levitation voltage value. On the other hand, the breakdown voltage test results demonstrate that larger and sharper particles result in lower measured breakdown voltage values, and vice versa. The simulation outcomes regarding electric field distribution reveal that larger and sharper particles correspond to higher measured electric field values, while the opposite is true for smaller and less sharp particles.


  • Open Access

    The Influence of Iron Particle Contamination on the Breakdown Characteristics of Circulating Mineral Oil under DC Voltage

    by Daniar Fahmi, Muhammad Fadlan Akbar, I Made Yulistya Negara, Dimas Anton Asfani, I Gusti Ngurah Satriyadi Hernanda

    The presence of metallic particles can lead to the degradation of transformer oil due to the intensification of the electric fields near the conductive components. The primary objective of this research was to investigate the impact of iron impurities on the electrical properties of Mineral Oil (MO), particularly under conditions of continuous flow. Five distinct samples with varying levels of contaminants were carefully prepared for analysis. A specialized chamber was designed to replicate the circulation conditions of oil within an operating transformer. The focus of the investigation was on the breakdown characteristics under DC voltages. The results indicated that higher concentrations of iron impurities were associated with a reduction in breakdown voltage although the circulation of oil exhibited a beneficial effect. To validate these findings, Finite Element Method (FEM)-based simulations were conducted. The analysis of the electric field distribution revealed that iron impurities amplified the electric field intensity, while circulation served to mitigate this effect. Furthermore, the simulations tracking the trajectory of iron particles demonstrated that circulation hindered the particles from reaching the electrodes, thereby diminishing discharge events and lowering the risk of dielectric failure. In conclusion, the circulation of MO enhanced its breakdown voltage, although the presence of iron contamination could still pose a risk under DC voltage conditions.


  • Partial discharge characteristics from polymer insulator under various contaminant

    by Daniar Fahmi, Dimas Anton Asfani, I Gusti Ngurah Satriyadi Hernanda, Bagus Septianto, I Made Yulistya Negara, Hazlee Azil Illias


  • Effect of Grounding Rods Position and Fly Ash Material on Grounding Resistance in Limestone Soil

    by I Gusti Ngurah Satriyadi Hernanda, Arief Budi Ksatria, I Made Yulistya Negara, I Putu Cahya Suardana, Dimas Anton Asfani, Putri Jelita Mirnafandi

    This research was conducted using rod electrodes that were installed in 2 positions, namely Vertical and Horizontal using the Three Point Method of grounding which were arranged with different depth variations. The deepest measurement results obtained in the vertical position with a depth of 2 meters is 15.04 Ohms while in the Horizontal position with a depth of 1 meter it is 24.54 Ohms. The measurement results obtained will be compared with the results of the calculations that have been carried out. Because the measurement results are still far from the PUIL 2000 standard limit, this study also carried out treatment to the ground using fly ash to determine the decrease in ground resistance after fly ash was installed or before fly ash was installed. During 8 weeks of measurement using an earth resistance tester, it was found that fly ash was able to reduce the grounding value by 10 Ohms. The condition of the electrodes after configuration for 8 weeks with fly ash was in good condition and there was no corrosion on the electrodes even though it had rained at the research site.


  • The Correlation of the Jump Phenomenon Characteristics to Ferroresonance in 3-Phase Transformer

    by I Gusti Ngurah Satriyadi Hernanda, I Made Yulistya Negara, Dimas Anton Asfani, Afif Al Arif, Naoki Satryo Anggito, Bonifacius Kevin Yegar Sahaduta

    Ferroresonance is a phenomenon that occurs in the transformer core, and is characterized by the presence of abnormal voltages. An electrical circuit that can cause ferroresonance has elements of resistance (R), capacitance (C), and non-linear inductance (L). In this research, the phenomenon of a surge in the value of the transformer current and voltage, which has changed drastically (jump phenomenon) after being triggered by an increase in the source voltage of about 1%, has been found out. The emergence of this jump phenomenon can trigger the emergence of ferroresonance. This will cause the transformer not to work normally in its linear region but in non-linear (saturation) regions. The test has been carried out on a 220 V 3-phase low-voltage transformer with H-core type and M-core type. Then the initiation factors such as source voltage variation and capacitance variation have been given to the system. Trends in the waveforms of voltage, current, voltage at source, transformer capacitor have been analyzed. The test results have showed that the given initiation factor can explain the correlation between the jump phenomenon characteristics and the presence of ferroresonance in the H-core and M-core transformers. When ferroresonance has appeared, the voltage value has been relatively high in the H-core type transformer. The largest value of voltage and current of the transformer occurs at 30 uF in S-phase with a transformer voltage value of 265.8 V and a current value of 5.7 A. Whereas, the ferroresonance mode in H-core and M-core is the fundamental ferroresonance mode. Copyright © 2021 Praise Worthy Prize - All rights reserved.

  • Identification of Ferroresonance on Transformer using Wavelet Transformatio

    by I Made Yulistya Negara, I Gusti Ngurah Satriyadi Hernanda, Dimas Anton Asfani, Daniar Fahmi, Luthfi Lukman Hakim, I Gede Arka Prawira Putra

    Ferroresonance is a transient phenomenon characterized by overvoltage and waveform mismatches affected by a combination of nonlinear inductances and capacitors. Even though ferroressonance is a transient phenomenon however the impact of the ferroresonance continue for a steady state that causes excess temperature and finaly damage the impacted apparatus . Therefore, this study concern to understand and identify ferroresonance phenomena and at the end to distinguish them from other disturbances such as overvoltage and harmonics. Ferroresonance initiation is carried out on a laboratory scale using a basic circuit of ferroresonance consisting of capacitors and transformers. Two kind of transformer core topologies, namely H type and M type, was used in the experiments. Moreover other disturbances such as harmonics was also simulated in laboratory. The ferroresonance and harmonic waveform then be processed using wavelet transformations and its cumulative energy was also determined. The results shows that for H type transformer the threshold value that distinguishes ferroresonance from other disturbances is about 9.24. On the other hand for M type transformer was about 7.97. Based on these values, the type of transformer core affect the energy level of ferroresonance. Moreover wavelet transformation could identify between ferroresonance and other disturbance under study very well, however further study should be done to investigate the effectivity of wavelet to discriminate all possible mode of ferroresonance.


  • Real-Time Battery Monitoring and Fault Identification Application on Electric Scooter

    by Dimas Anton Asfani, I Made Yulistya Negara, I Gusti Ngurah Satriyadi Hernanda, Daniar Fahmi, Muhammad Nur Yuniarto, Rizal Hardiyanto, Raditya Premananda

    Peoples have shifted from fossil fuel-powered vehicles to electric vehicles these days. It is environmentally friendly and also saves more energy. Electric scooter has two main components which are BLDC motor as a prime mover and battery as energy storage. Therefore, design of monitoring and diagnosing instruments are needed to maintain battery performance. Design of the instrument necessarily arranged to optimize the battery usage, monitor and identify an interruption or damage on battery used in electric scooter. Parameters used in design are voltage, current, temperature, and battery capacity. Furthermore, in optimizing the battery usage, all of the parameters are processed by a Controller Area Network (CAN) protocol. The parameters will be displayed on android smartphone to provide the scooter performance and give an alert if the interruption or damage is occurred such as over temperature and unbalanced cell. Based on the experiment results, it is shown that maximum error for current testing is 2.17% and for voltage testing is 0.09%. Maximum unbalance cell testing value reaches 12 % with an average value over 1 minute is 8.4% while safe limit of unbalance cell is 10%.


  • Floating Metal Particle Motion Characteristics with Shape and Size Variation in the Oil Insulation Under DC Voltage

    by Daniar Fahmi, I Made Yulistya Negara, Dimas Anton Asfani, I Gusti Ngurah Satriyadi Hernanda, Tasha Hadianty Deliana, Juan Christian Soebagio

    Liquid insulation may fail on utilizing its functions due to aging. Aging is caused by the presence of materials such as solid particles, oxygen, water, piles of deposits, dirt, and dust. The solid particles in form of copper, aluminum, stainless steel, and other metal materials may cause impurities and lower the value of breakdown voltage. These particles may float in oil and have different motion and breakdown characteristic. This study was conducted with variable on particles of stainless steel as contaminants. Contaminants vary in shape and size, i.e. spherical and elliptical shape particles with different size. This test was carried out by using DC high voltage generation. Video recording was done to capture the movement pattern of floating metal particles with a high speed camera. Nonetheless, CST simulation was running to determine the field value (E) when the particle moves. The results of the tests showed that the smaller the particle diameter, the greater the breakdown voltage value. Furthermore, particle size has an effect on the pattern of movement of floating metal particles. The larger the particles is, the more cycle generated and the faster floating metal particles move.


  • Low-Voltage Arcing Detection on Non-Linear Load with Total Harmonic Distortion and Power Factor Variations

    by Dimas Anton Asfani, Daniar Fahmi, I Made Yulistya Negara, I Gusti Ngurah Satriyadi Hernanda, Jefri Haris Setyadi, Made Yudha Pranadiksa Giri

    Fires in residential areas are generally caused by low-voltage arcing. This phenomenon has unique characteristics, very high current magnitude and very fast period. Therefore, low-voltage arcing can’t be detected by circuit breaker. The study about low-voltage arcing detection on non-linear load with total harmonic distortion (THD) and power factor (cos phi) variations has been conducted. There were two observation conditions, arcing and normal condition. This study has been able to detect low-voltage arcing. Based on wavelet transformation, maximum value of high frequency (HF) current and the number of arc points that exceeds the HF current threshold (2 A) were used to differentiate between arcing and normal conditions. Based on the analysis results, maximum value of HF current and the number of arc points at arcing condition are not affected by THD and power factor variations.