YZYong Zhao

Yong Zhao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yong Zhao has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Diagnosis of Demagnetization Faults in PMSGs Based on Performance Evaluation of Machine Learning Algorithms Through Flux and Current Signals

    by Nadeem Shahbaz, Yu Chen, Feng Liang, Sichao Zhang, Shouwang Zhao, Yong Ma, Chong Li, Wei Deng, Yong Zhao

    This study proposed an effective machine learning (ML)-based fault diagnosis method for demagnetization faults, including "healthy, 30% unipolar demagnetization, 50% multi magnet demagnetization, 100% adjacent pole demagnetization, and 40% uniform demagnetization", in a 25-kW permanent magnet synchronous generator (PMSG) that considers algorithm accuracy and signal processing technique efficiency, top informative features, and training time of the ML algorithm. Our research involves developing a 3D finite element PMSG model in ANSYS Maxwell and conducting an industrial experiment to capture stator current and flux data. We employ advanced feature extraction techniques such as matching pursuit and discrete wavelet transform, assessing their accuracy using Ensemble, SVM, and KNN algorithms. Additionally, we optimize and rank features using ReliefF, mRMR, Chi2, ANOVA, and Kruskal‒Wallis filters, evaluating their impact on ML algorithms. The investigation extends to the evaluation of eight ML classifiers—ensemble, SVM, KNN, neural network, kernel, discriminant analysis, and naive Bayes—along with 31 subclassifiers to identify the most effective output signal, signal processing technique, informative features, suitable filters, and the optimal ML algorithm for diagnosing demagnetization faults in PMSGs. Our findings reveal that using flux signals in conjunction with the discrete wavelet transform, alongside the ANOVA feature ranking filter and fine Gaussian SVM algorithm, achieves 100% fault classification accuracy with a training time of 0.961 seconds. This approach proves highly effective for the early detection of demagnetization faults in PMSGs.


  • Identifying Early Stator Fault Severity in DFIGs Based on Adaptive Feature Mode Decomposition and Multiscale Complex Component Current Trajectories

    by Shouwang Zhao, Yu Chen, Feng Liang, Sichao Zhang, Nadeem Shahbaz, Shuang Wang, Yong Zhao, Wei Deng, Yonghong Cheng

    Early fault detection is critical for ensuring reliable operation in wind power generation systems employing Doubly Fed Induction Generators (DFIGs). Although the widespread use of motor current signature analysis (MCSA) for noninvasive fault detection, early-stage faults in DFIGs often present with weak characteristic fault information, posing challenges for detection amidst noise and interference signals. This paper proposes a novel method to assess the severity of early stator interturn short circuits (ITSCs) in DFIGs by combining adaptive feature mode decomposition (AFMD) with multiscale analysis of complex component current trajectories. AFMD is applied to perform quadratic time-frequency decomposition of current signals, resulting in a series of modal components with diverse frequency contents. By selecting the low-frequency current modal components with the fundamental frequency and low-order harmonics, high-frequency interferences and noise are effectively filtered out. The extracted low-frequency current modal components undergo multiscale Park vector trajectory analysis, thereby enhancing the expression of weak fault characteristics associated with early ITSCs. Further analysis involves the extraction of negative sequence current (NSC) and zero-sequence current (ZSC) components from the low-frequency modal components. The residual ZSC signal is constructed by filter out the fundamental frequency and low-order harmonic components from the ZSC component of the low-frequency modal. Analysis of the symmetrized dot pattern of the residual ZSC signal captures the evolution process of early-stage ITSCs with a low number of turns. Additionally, the negative sequence current of the low-frequency modal components is qualitatively and quantitatively evaluated for early low-turn insulation short circuits of varying severity levels. Experimental validation on a 100 kW DFIG test platform demonstrates the efficacy of the proposed method in enhancing the detection and diagnosis of early-stage ITSC faults.


  • Detection of Interturn Short-Circuit Faults in DFIGs Based on External Leakage Flux Sensing and the VMD-RCMDE Analytical Method

    by Shouwang Zhao, Yu Chen, Attiq Ur Rehman, Feng Liang, Shuang Wang, Yong Zhao, Wei Deng, Yong Ma, Yonghong Cheng

    Fault detection based on external leakage flux can address various faults, such as short-circuit faults in stators and rotors. External leakage flux sensing technology, as a noninvasive method, has been attracting increasing attention and research. However, for a high-power doubly fed induction generator (DFIG), the external leakage flux signals of the generator are easily overwhelmed by a strong noise background, and the fault diagnosis and recognition of stator interturn short circuit (S-ITSC) and rotor ITSC (R-ITSC) are complicated, which limit the practical engineering application of leakage flux sensing technology. Aiming at addressing ITSC faults in DFIGs, this article proposes a method for fault feature extraction and recognition of stator and rotor short circuits based on variational mode decomposition (VMD) and the refined composite multiscale dispersion entropy (RCMDE) analytical method for the external flux leakage of the generator. The optimized parameters of VMD are selected automatically by the genetic algorithm (GA), and VMD is adopted to adaptively decompose the external leakage flux signals into a series of intrinsic mode function (IMF) components. The evaluation criterion based on the correlation number in the frequency domain combined with the autocorrelation function is used to select the best IMF components with clear features. Two different components are chosen to reconstruct the flux leakage signal. The characteristic frequency of the reconstructed signal is analyzed by the Hilbert–Huang transform (HHT) and the total harmonic effective value of the characteristic component. To effectively identify and diagnose the generator S-ITSC and R-ITSC faults, RCMDE is used for the flux leakage reconstructed signal. The experimental results under different stator and rotor short-circuit levels show that this diagnosis method can effectively extract the weak feature information from the external flux leakage signals and perform fault feature extraction and recognition for stator and rotor short circuits.


  • Open Access

    An Integrated Approach-Based FMECA for Risk Assessment: Application to Offshore Wind Turbine Pitch System

    by Zhen Wang, Rongxi Wang, Wei Deng, Yong Zhao

    Failure mode, effects and criticality analysis (FMECA) is a well-known reliability analysis tool for recognizing, evaluating and prioritizing the known or potential failures in system, design, and process. In conventional FMECA, the failure modes are evaluated by using three risk factors, severity (S), occurrence (O) and detectability (D), and their risk priorities are determined by multiplying the crisp values of risk factors to obtain their risk priority numbers (RPNs). However, the conventional RPN has been considerably criticized due to its various shortcomings. Although significant efforts have been made to enhance the performance of traditional FMECA, some drawbacks still exist and need to be addressed in the real application. In this paper, a new FMECA model for risk analysis is proposed by using an integrated approach, which introduces Z-number, Rough number, the Decision-making trial and evaluation laboratory (DEMATEL) method and the VIsekriterijumska optimizacija i KOmpromisno Resenje (VIKOR) method to FMECA to overcome its deficiencies in real application. The novelty of this paper in theory is that the proposed approach integrates the strong expressive ability of Z-numbers to vagueness and uncertainty information, the strong point of DEMATEL method in studying the dependence among failure modes, the advantage of rough numbers for aggregating experts’ diversity evaluations, and the strength of VIKOR method to flexibly model multi-criteria decision-making problems. Based on the integrated approach, the proposed risk assessment model can favorably capture and aggregate FMECA team members’ diversity evaluations and prioritize failure modes under different types of uncertainties with considering the failure propagation. In terms of application, the proposed approach was applied to the risk analysis of failure modes in offshore wind turbine pitch system, and it can also be used in many industrial fields for risk assessment and safety analysis.


  • FEM simulation and analysis on stator winding inter-turn fault in DFIG

    by Yu Chen, Lulu Wang, Zihao Wang, Attiq Ur Rehman, Yonghong Cheng, Yong Zhao, Toshikatsu Tanaka

    With the development of renewable energy technology, Doubly-Fed Induction Generators (DFIG) are widely used on wind farms. Faults of machines have a direct influence on the safety and effectiveness of the power grid. In order to explore failure mechanism, it is of great importance to study the DFIG fault simulation models and features. In this paper, a Finite Element Method (FEM) simulation model of stator winding inter-turn fault in DFIG is presented by the software of ANSYS Maxwell. Different stator inter-turn short circuit fault conditions are achieved by changing the stator winding connection and the values of end leakage-inductance and resistance. Under normal condition, different branches' currents are the same in each phase and different phase currents are balanced. So the Total Harmonic Distortions (THD) of three-phase stator currents are low and phase differences of stator currents are all about 120°. Additionally, Park's vector trajectory is a circle and its eccentricity is approximately zero. However, as the fault degree enlarges, both the current of faulty-branch and the eccentricity of Park's vector trajectory increase. The phase differences related to faulty-phase and THD of faulty-phase become larger. Therefore, THD, phase differences and the eccentricity can be regarded as three fault features to diagnose fault phase and fault degree.