Shouwang Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shouwang Zhao has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Yu Chen
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
4 shared publications - Feng Liang
School of Electrical Engineering, Xian Jiaotong University, Xian, Shaanxi, China
3 shared publications - Shuang Wang
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
3 shared publications - Wei Deng
Xian Thermal Power Research Institute Company Ltd., Xian, Shaanxi, China
3 shared publications - Yong Zhao
Xian Thermal Power Research Institute Company Ltd., Xian, Shaanxi, China
3 shared publications - Yonghong Cheng
State Key Laboratory of Electrical Insulation and Power Equipment
3 shared publications
Latest Publications
- 14 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Diagnosis of Demagnetization Faults in PMSGs Based on Performance Evaluation of Machine Learning Algorithms Through Flux and Current Signals
This study proposed an effective machine learning (ML)-based fault diagnosis method for demagnetization faults, including "healthy, 30% unipolar demagnetization, 50% multi magnet demagnetization, 100% adjacent pole demagnetization, and 40% uniform demagnetization", in a 25-kW permanent magnet synchronous generator (PMSG) that considers algorithm accuracy and signal processing technique efficiency, top informative features, and training time of the ML algorithm. Our research involves developing a 3D finite element PMSG model in ANSYS Maxwell and conducting an industrial experiment to capture stator current and flux data. We employ advanced feature extraction techniques such as matching pursuit and discrete wavelet transform, assessing their accuracy using Ensemble, SVM, and KNN algorithms. Additionally, we optimize and rank features using ReliefF, mRMR, Chi2, ANOVA, and Kruskal‒Wallis filters, evaluating their impact on ML algorithms. The investigation extends to the evaluation of eight ML classifiers—ensemble, SVM, KNN, neural network, kernel, discriminant analysis, and naive Bayes—along with 31 subclassifiers to identify the most effective output signal, signal processing technique, informative features, suitable filters, and the optimal ML algorithm for diagnosing demagnetization faults in PMSGs. Our findings reveal that using flux signals in conjunction with the discrete wavelet transform, alongside the ANOVA feature ranking filter and fine Gaussian SVM algorithm, achieves 100% fault classification accuracy with a training time of 0.961 seconds. This approach proves highly effective for the early detection of demagnetization faults in PMSGs.
- 14 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Diagnosis of Demagnetization Faults in PMSGs Based on Performance Evaluation of Machine Learning Algorithms Through Flux and Current Signals
This study proposed an effective machine learning (ML)-based fault diagnosis method for demagnetization faults, including "healthy, 30% unipolar demagnetization, 50% multi magnet demagnetization, 100% adjacent pole demagnetization, and 40% uniform demagnetization", in a 25-kW permanent magnet synchronous generator (PMSG) that considers algorithm accuracy and signal processing technique efficiency, top informative features, and training time of the ML algorithm. Our research involves developing a 3D finite element PMSG model in ANSYS Maxwell and conducting an industrial experiment to capture stator current and flux data. We employ advanced feature extraction techniques such as matching pursuit and discrete wavelet transform, assessing their accuracy using Ensemble, SVM, and KNN algorithms. Additionally, we optimize and rank features using ReliefF, mRMR, Chi2, ANOVA, and Kruskal‒Wallis filters, evaluating their impact on ML algorithms. The investigation extends to the evaluation of eight ML classifiers—ensemble, SVM, KNN, neural network, kernel, discriminant analysis, and naive Bayes—along with 31 subclassifiers to identify the most effective output signal, signal processing technique, informative features, suitable filters, and the optimal ML algorithm for diagnosing demagnetization faults in PMSGs. Our findings reveal that using flux signals in conjunction with the discrete wavelet transform, alongside the ANOVA feature ranking filter and fine Gaussian SVM algorithm, achieves 100% fault classification accuracy with a training time of 0.961 seconds. This approach proves highly effective for the early detection of demagnetization faults in PMSGs.
- 23 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-16
Identifying Early Stator Fault Severity in DFIGs Based on Adaptive Feature Mode Decomposition and Multiscale Complex Component Current Trajectories
Early fault detection is critical for ensuring reliable operation in wind power generation systems employing Doubly Fed Induction Generators (DFIGs). Although the widespread use of motor current signature analysis (MCSA) for noninvasive fault detection, early-stage faults in DFIGs often present with weak characteristic fault information, posing challenges for detection amidst noise and interference signals. This paper proposes a novel method to assess the severity of early stator interturn short circuits (ITSCs) in DFIGs by combining adaptive feature mode decomposition (AFMD) with multiscale analysis of complex component current trajectories. AFMD is applied to perform quadratic time-frequency decomposition of current signals, resulting in a series of modal components with diverse frequency contents. By selecting the low-frequency current modal components with the fundamental frequency and low-order harmonics, high-frequency interferences and noise are effectively filtered out. The extracted low-frequency current modal components undergo multiscale Park vector trajectory analysis, thereby enhancing the expression of weak fault characteristics associated with early ITSCs. Further analysis involves the extraction of negative sequence current (NSC) and zero-sequence current (ZSC) components from the low-frequency modal components. The residual ZSC signal is constructed by filter out the fundamental frequency and low-order harmonic components from the ZSC component of the low-frequency modal. Analysis of the symmetrized dot pattern of the residual ZSC signal captures the evolution process of early-stage ITSCs with a low number of turns. Additionally, the negative sequence current of the low-frequency modal components is qualitatively and quantitatively evaluated for early low-turn insulation short circuits of varying severity levels. Experimental validation on a 100 kW DFIG test platform demonstrates the efficacy of the proposed method in enhancing the detection and diagnosis of early-stage ITSC faults.
- 23 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-16
Identifying Early Stator Fault Severity in DFIGs Based on Adaptive Feature Mode Decomposition and Multiscale Complex Component Current Trajectories
Early fault detection is critical for ensuring reliable operation in wind power generation systems employing Doubly Fed Induction Generators (DFIGs). Although the widespread use of motor current signature analysis (MCSA) for noninvasive fault detection, early-stage faults in DFIGs often present with weak characteristic fault information, posing challenges for detection amidst noise and interference signals. This paper proposes a novel method to assess the severity of early stator interturn short circuits (ITSCs) in DFIGs by combining adaptive feature mode decomposition (AFMD) with multiscale analysis of complex component current trajectories. AFMD is applied to perform quadratic time-frequency decomposition of current signals, resulting in a series of modal components with diverse frequency contents. By selecting the low-frequency current modal components with the fundamental frequency and low-order harmonics, high-frequency interferences and noise are effectively filtered out. The extracted low-frequency current modal components undergo multiscale Park vector trajectory analysis, thereby enhancing the expression of weak fault characteristics associated with early ITSCs. Further analysis involves the extraction of negative sequence current (NSC) and zero-sequence current (ZSC) components from the low-frequency modal components. The residual ZSC signal is constructed by filter out the fundamental frequency and low-order harmonic components from the ZSC component of the low-frequency modal. Analysis of the symmetrized dot pattern of the residual ZSC signal captures the evolution process of early-stage ITSCs with a low number of turns. Additionally, the negative sequence current of the low-frequency modal components is qualitatively and quantitatively evaluated for early low-turn insulation short circuits of varying severity levels. Experimental validation on a 100 kW DFIG test platform demonstrates the efficacy of the proposed method in enhancing the detection and diagnosis of early-stage ITSC faults.
- 24 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-12
Detection of Interturn Short-Circuit Faults in DFIGs Based on External Leakage Flux Sensing and the VMD-RCMDE Analytical Method
Fault detection based on external leakage flux can address various faults, such as short-circuit faults in stators and rotors. External leakage flux sensing technology, as a noninvasive method, has been attracting increasing attention and research. However, for a high-power doubly fed induction generator (DFIG), the external leakage flux signals of the generator are easily overwhelmed by a strong noise background, and the fault diagnosis and recognition of stator interturn short circuit (S-ITSC) and rotor ITSC (R-ITSC) are complicated, which limit the practical engineering application of leakage flux sensing technology. Aiming at addressing ITSC faults in DFIGs, this article proposes a method for fault feature extraction and recognition of stator and rotor short circuits based on variational mode decomposition (VMD) and the refined composite multiscale dispersion entropy (RCMDE) analytical method for the external flux leakage of the generator. The optimized parameters of VMD are selected automatically by the genetic algorithm (GA), and VMD is adopted to adaptively decompose the external leakage flux signals into a series of intrinsic mode function (IMF) components. The evaluation criterion based on the correlation number in the frequency domain combined with the autocorrelation function is used to select the best IMF components with clear features. Two different components are chosen to reconstruct the flux leakage signal. The characteristic frequency of the reconstructed signal is analyzed by the Hilbert–Huang transform (HHT) and the total harmonic effective value of the characteristic component. To effectively identify and diagnose the generator S-ITSC and R-ITSC faults, RCMDE is used for the flux leakage reconstructed signal. The experimental results under different stator and rotor short-circuit levels show that this diagnosis method can effectively extract the weak feature information from the external flux leakage signals and perform fault feature extraction and recognition for stator and rotor short circuits.
- 24 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-12
Detection of Interturn Short-Circuit Faults in DFIGs Based on External Leakage Flux Sensing and the VMD-RCMDE Analytical Method
Fault detection based on external leakage flux can address various faults, such as short-circuit faults in stators and rotors. External leakage flux sensing technology, as a noninvasive method, has been attracting increasing attention and research. However, for a high-power doubly fed induction generator (DFIG), the external leakage flux signals of the generator are easily overwhelmed by a strong noise background, and the fault diagnosis and recognition of stator interturn short circuit (S-ITSC) and rotor ITSC (R-ITSC) are complicated, which limit the practical engineering application of leakage flux sensing technology. Aiming at addressing ITSC faults in DFIGs, this article proposes a method for fault feature extraction and recognition of stator and rotor short circuits based on variational mode decomposition (VMD) and the refined composite multiscale dispersion entropy (RCMDE) analytical method for the external flux leakage of the generator. The optimized parameters of VMD are selected automatically by the genetic algorithm (GA), and VMD is adopted to adaptively decompose the external leakage flux signals into a series of intrinsic mode function (IMF) components. The evaluation criterion based on the correlation number in the frequency domain combined with the autocorrelation function is used to select the best IMF components with clear features. Two different components are chosen to reconstruct the flux leakage signal. The characteristic frequency of the reconstructed signal is analyzed by the Hilbert–Huang transform (HHT) and the total harmonic effective value of the characteristic component. To effectively identify and diagnose the generator S-ITSC and R-ITSC faults, RCMDE is used for the flux leakage reconstructed signal. The experimental results under different stator and rotor short-circuit levels show that this diagnosis method can effectively extract the weak feature information from the external flux leakage signals and perform fault feature extraction and recognition for stator and rotor short circuits.
- 30 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
Photoelectron Emission Yield of Au Film: Theoretical Calculation and Measurement
Spacecraft in orbit are exposed to intense solar radiation in the space environment, causing the material surface to be charged and damaged. The incident electrons, ions, and photons on the surface of spacecraft materials produce secondary electrons, backscattered electrons, photoelectrons, and so on. The damage to the material caused by the emitted photocurrent is more serious when the incident energy is higher than the photoelectric threshold. In view of the significant threat of particle radiation to the charge protection and operational life of spacecraft materials, in this article, a theoretical model of the photoelectron emission yield (PEEY) is studied, and a test system of metal materials under ultraviolet light is developed. First, we derive a three-step model of the photoemission of metal materials and calculate the PEEY spectrum of Au. Second, the optical system is built by using a deuterium lamp, a monochromator, and an aperture. The installation structure of the photodiode is designed, and the photon number is obtained by measuring the incident luminous flux. Third, a central through-hole microchannel plate is used and a voltage division circuit module is designed to realize effective collection of photoelectrons emitted from the sample surface. This approach realizes a detectable range for an Au film from 10 −4 to 10 −7 el./ph in the spectral range of 130–258 nm. The reliability of the test system is proved by comparing the experimental results with the theoretical results.
- 30 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
Photoelectron Emission Yield of Au Film: Theoretical Calculation and Measurement
Spacecraft in orbit are exposed to intense solar radiation in the space environment, causing the material surface to be charged and damaged. The incident electrons, ions, and photons on the surface of spacecraft materials produce secondary electrons, backscattered electrons, photoelectrons, and so on. The damage to the material caused by the emitted photocurrent is more serious when the incident energy is higher than the photoelectric threshold. In view of the significant threat of particle radiation to the charge protection and operational life of spacecraft materials, in this article, a theoretical model of the photoelectron emission yield (PEEY) is studied, and a test system of metal materials under ultraviolet light is developed. First, we derive a three-step model of the photoemission of metal materials and calculate the PEEY spectrum of Au. Second, the optical system is built by using a deuterium lamp, a monochromator, and an aperture. The installation structure of the photodiode is designed, and the photon number is obtained by measuring the incident luminous flux. Third, a central through-hole microchannel plate is used and a voltage division circuit module is designed to realize effective collection of photoelectrons emitted from the sample surface. This approach realizes a detectable range for an Au film from 10 −4 to 10 −7 el./ph in the spectral range of 130–258 nm. The reliability of the test system is proved by comparing the experimental results with the theoretical results.