KFKathleen F. Faulkner

Kathleen F. Faulkner

*This is an algorithmically generated author record based on publicly available information.

Kathleen F. Faulkner has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of frequency-to-place mismatch on speech and music sound quality in acoustic cochlear implant simulation

    by Louis Villejoubert, Lorenzo Picinali, Kathleen Faulkner, Deborah Vickers

    Sound quality perception for cochlear implant (CI) users has become increasingly important. Although many CI users achieve near-normal speech recognition in quiet, they often report poor sound quality, particularly for music. One factor contributing to this degradation is frequency-to-place mismatch (FTPM), which occurs when electrode positions do not align with the cochlea's characteristic frequency map. This study aimed to better understand the impact of FTPM on sound quality in CI simulations across different signal types and configurations. Twenty-three normal-hearing participants were tested (online or onsite) using an adapted MUlti Stimulus test with Hidden Reference and Anchor (MUSHRA) paradigm. Different FTPM configurations were simulated with a noise vocoder to assess their influence on speech and music sound quality. Results showed that greater FTPM caused noticeable degradation, especially when lower frequencies were affected. Variability in FTPM across electrodes also significantly reduced perceived quality. Furthermore, the impact of FTPM depended on the type of stimulus, with speech and music showing distinct sensitivity patterns. Online assessments closely matched onsite results, confirming the reliability of remote testing. Together, these findings clarify why sound quality perception differs between CI users and contexts and highlight new opportunities to develop strategies for alleviating mismatch effects in CIs.

  • Open Access

    Perceived auditory dynamic range is enhanced with wrist-based tactile stimulation

    by Scott C. Aker, Kathleen F. Faulkner, Hamish Innes-Brown, Jeremy Marozeau

    Tactile stimulation has been shown to increase auditory loudness judgments in listeners. This bias could be utilized to enhance perception for people with deficiencies in auditory intensity perception, such as cochlear implant users. However, several aspects of this enhancement remain uncertain. For instance, does the tactile stimulation need to be applied to the hand or body, or can it be applied to the wrist? Furthermore, can the tactile stimulation both amplify and attenuate the perceived auditory loudness? To address these questions, two loudness-matching experiments were conducted. Participants matched a comparison auditory stimulus with an auditory reference, either with or without spectro-temporally identical tactile stimulation. In the first experiment, fixed-level tactile stimulation was administered to the wrist during the comparison stimulus to assess whether perceived auditory loudness increased. The second experiment replicated the same conditions but introduced tactile stimulation to both the reference and comparison, aiming to investigate the potential decrease in perceived auditory loudness when the two tactile accompaniments were incongruent between the reference and comparison. The results provide evidence supporting the existence of the tactile loudness bias in each experiment and are a step towards wrist-based haptic devices that modulate the auditory dynamic range for a user.


  • Open Access

    Some, but not all, cochlear implant users prefer music stimuli with congruent haptic stimulation

    by Scott C. Aker, Kathleen F. Faulkner, Hamish Innes-Brown, Marianna Vatti, Jeremy Marozeau

    Cochlear implant (CI) users often report being unsatisfied by music listening through their hearing device. Vibrotactile stimulation could help alleviate those challenges. Previous research has shown that musical stimuli was given higher preference ratings by normal-hearing listeners when concurrent vibrotactile stimulation was congruent in intensity and timing with the corresponding auditory signal compared to incongruent. However, it is not known whether this is also the case for CI users. Therefore, in this experiment, we presented 18 CI users and 24 normal-hearing listeners with five melodies and five different audio-to-tactile maps. Each map varied the congruence between the audio and tactile signals related to intensity, fundamental frequency, and timing. Participants were asked to rate the maps from zero to 100, based on preference. It was shown that almost all normal-hearing listeners, as well as a subset of the CI users, preferred tactile stimulation, which was congruent with the audio in intensity and timing. However, many CI users had no difference in preference between timing aligned and timing unaligned stimuli. The results provide evidence that vibrotactile music enjoyment enhancement could be a solution for some CI users; however, more research is needed to understand which CI users can benefit from it most.


  • Open Access

    Effect of audio-tactile congruence on vibrotactile music enhancement

    by Scott C. Aker, Hamish Innes-Brown, Kathleen F. Faulkner, Marianna Vatti, Jeremy Marozeau

    Music listening experiences can be enhanced with tactile vibrations. However, it is not known which parameters of the tactile vibration must be congruent with the music to enhance it. Devices that aim to enhance music with tactile vibrations often require coding an acoustic signal into a congruent vibrotactile signal. Therefore, understanding which of these audio-tactile congruences are important is crucial. Participants were presented with a simple sine wave melody through supra-aural headphones and a haptic actuator held between the thumb and forefinger. Incongruent versions of the stimuli were made by randomizing physical parameters of the tactile stimulus independently of the auditory stimulus. Participants were instructed to rate the stimuli against the incongruent stimuli based on preference. It was found making the intensity of the tactile stimulus incongruent with the intensity of the auditory stimulus, as well as misaligning the two modalities in time, had the biggest negative effect on ratings for the melody used. Future vibrotactile music enhancement devices can use time alignment and intensity congruence as a baseline coding strategy, which improved strategies can be tested against.


  • Open Access

    Multidimensional Timbre Spaces of Cochlear Implant Vocoded and Non-vocoded Synthetic Female Singing Voices

    by Molly L. Erickson, Katie Faulkner, Patti M. Johnstone, Mark S. Hedrick, Taylor Stone

    Many post-lingually deafened cochlear implant (CI) users report that they no longer enjoy listening to music, which could possibly contribute to a perceived reduction in quality of life. One aspect of music perception, vocal timbre perception, may be difficult for CI users because they may not be able to use the same timbral cues available to normal hearing listeners. Vocal tract resonance frequencies have been shown to provide perceptual cues to voice categories such as baritone, tenor, mezzo-soprano, and soprano, while changes in glottal source spectral slope are believed to be related to perception of vocal quality dimensions such as fluty vs. brassy. As a first step toward understanding vocal timbre perception in CI users, we employed an 8-channel noise-band vocoder to test how vocoding can alter the timbral perception of female synthetic sung vowels across pitches. Non-vocoded and vocoded stimuli were synthesized with vibrato using 3 excitation source spectral slopes and 3 vocal tract transfer functions (mezzo-soprano, intermediate, soprano) at the pitches C4, B4, and F5. Six multi-dimensional scaling experiments were conducted: C4 not vocoded, C4 vocoded, B4 not vocoded, B4 vocoded, F5 not vocoded, and F5 vocoded. At the pitch C4, for both non-vocoded and vocoded conditions, dimension 1 grouped stimuli according to voice category and was most strongly predicted by spectral centroid from 0 to 2 kHz. While dimension 2 grouped stimuli according to excitation source spectral slope, it was organized slightly differently and predicted by different acoustic parameters in the non-vocoded and vocoded conditions. For pitches B4 and F5 spectral centroid from 0 to 2 kHz most strongly predicted dimension 1. However, while dimension 1 separated all 3 voice categories in the vocoded condition, dimension 1 only separated the soprano stimuli from the intermediate and mezzo-soprano stimuli in the non-vocoded condition. While it is unclear how these results predict timbre perception in CI listeners, in general, these results suggest that perhaps some aspects of vocal timbre may remain.


  • Some Neurocognitive Correlates of Noise-Vocoded Speech Perception in Children With Normal Hearing: A Replication and Extension of Eisenberg et al. (2002)

    by Adrienne S. Roman, David B. Pisoni, William G. Kronenberger, Kathleen F. Faulkner

    Objectives: Noise-vocoded speech is a valuable research tool for testing experimental hypotheses about the effects of spectral degradation on speech recognition in adults with normal hearing (NH). However, very little research has utilized noise-vocoded speech with children with NH. Earlier studies with children with NH focused primarily on the amount of spectral information needed for speech recognition without assessing the contribution of neurocognitive processes to speech perception and spoken word recognition. In this study, we first replicated the seminal findings reported by Eisenberg et al. (2002) who investigated effects of lexical density and word frequency on noise-vocoded speech perception in a small group of children with NH. We then extended the research to investigate relations between noise-vocoded speech recognition abilities and five neurocognitive measures: auditory attention (AA) and response set, talker discrimination, and verbal and nonverbal short-term working memory. Design: Thirty-one children with NH between 5 and 13 years of age were assessed on their ability to perceive lexically controlled words in isolation and in sentences that were noise-vocoded to four spectral channels. Children were also administered vocabulary assessments (Peabody Picture Vocabulary test-4th Edition and Expressive Vocabulary test-2nd Edition) and measures of AA (NEPSY AA and response set and a talker discrimination task) and short-term memory (visual digit and symbol spans). Results: Consistent with the findings reported in the original Eisenberg et al. (2002) study, we found that children perceived noise-vocoded lexically easy words better than lexically hard words. Words in sentences were also recognized better than the same words presented in isolation. No significant correlations were observed between noise-vocoded speech recognition scores and the Peabody Picture Vocabulary test-4th Edition using language quotients to control for age effects. However, children who scored higher on the Expressive Vocabulary test-2nd Edition recognized lexically easy words better than lexically hard words in sentences. Older children perceived noise-vocoded speech better than younger children. Finally, we found that measures of AA and short-term memory capacity were significantly correlated with a child’s ability to perceive noise-vocoded isolated words and sentences. Conclusions: First, we successfully replicated the major findings from the Eisenberg et al. (2002) study. Because familiarity, phonological distinctiveness and lexical competition affect word recognition, these findings provide additional support for the proposal that several foundational elementary neurocognitive processes underlie the perception of spectrally degraded speech. Second, we found strong and significant correlations between performance on neurocognitive measures and children’s ability to recognize words and sentences noise-vocoded to four spectral channels. These findings extend earlier research suggesting that perception of spectrally degraded speech reflects early peripheral auditory processes, as well as additional contributions of executive function, specifically, selective attention and short-term memory processes in spoken word recognition. The present findings suggest that AA and short-term memory support robust spoken word recognition in children with NH even under compromised and challenging listening conditions. These results are relevant to research carried out with listeners who have hearing loss, because they are routinely required to encode, process, and understand spectrally degraded acoustic signals.


  • List Equivalency of PRESTO for the Evaluation of Speech Recognition

    by Kathleen F. Faulkner, Terrin N. Tamati, Jaimie L. Gilbert, David B. Pisoni

    Background:There is a pressing clinical need for the development of ecologically valid and robust assessment measures of speech recognition. Perceptually Robust English Sentence Test Open-set (PRESTO) is a new high-variability sentence recognition test that is sensitive to individual differences and was designed for use with several different clinical populations. PRESTO differs from other sentence recognition tests because the target sentences differ in talker, gender, and regional dialect. Increasing interest in using PRESTO as a clinical test of spoken word recognition dictates the need to establish equivalence across test lists.Purpose:The purpose of this study was to establish list equivalency of PRESTO for clinical use.Research Design:PRESTO sentence lists were presented to three groups of normal-hearing listeners in noise (multitalker babble [MTB] at 0 dB signal-to-noise ratio) or under eight-channel cochlear implant simulation (CI-Sim).Study Sample:Ninety-one young native speakers of English who were undergraduate students from the Indiana University community participated in this study.Data Collection and Analysis:Participants completed a sentence recognition task using different PRESTO sentence lists. They listened to sentences presented over headphones and typed in the words they heard on a computer. Keyword scoring was completed offline. Equivalency for sentence lists was determined based on the list intelligibility (mean keyword accuracy for each list compared with all other lists) and listener consistency (the relation between mean keyword accuracy on each list for each listener).Results:Based on measures of list equivalency and listener consistency, ten PRESTO lists were found to be equivalent in the MTB condition, nine lists were equivalent in the CI-Sim condition, and six PRESTO lists were equivalent in both conditions.Conclusions:PRESTO is a valuable addition to the clinical toolbox for assessing sentence recognition across different populations. Because the test condition influenced the overall intelligibility of lists, researchers and clinicians should take the presentation conditions into consideration when selecting the best PRESTO lists for their research or clinical protocols.


  • Sentence recognition in older adults

    by Kathleen F. Faulkner, Gary R. Kidd, Larry E. Humes, David B. Pisoni

  • Identifying Cochlear Implant Channels With Poor Electrode-Neuron Interfaces: Electrically Evoked Auditory Brain Stem Responses Measured With the Partial Tripolar Configuration

    by Julie Arenberg Bierer, Kathleen F. Faulkner, Kelly L. Tremblay

    Objectives: The goal of this study was to compare cochlear implant behavioral measures and electrically evoked auditory brain stem responses (EABRs) obtained with a spatially focused electrode configuration. It has been shown previously that channels with high thresholds, when measured with the tripolar configuration, exhibit relatively broad psychophysical tuning curves. The elevated threshold and degraded spatial/spectral selectivity of such channels are consistent with a poor electrode-neuron interface, defined as suboptimal electrode placement or reduced nerve survival. However, the psychophysical methods required to obtain these data are time intensive and may not be practical during a clinical mapping session, especially for young children. Here, we have extended the previous investigation to determine whether a physiological approach could provide a similar assessment of channel functionality. We hypothesized that, in accordance with the perceptual measures, higher EABR thresholds would correlate with steeper EABR amplitude growth functions, reflecting a degraded electrode-neuron interface. Design: Data were collected from six cochlear implant listeners implanted with the HiRes 90k cochlear implant (Advanced Bionics). Single-channel thresholds and most comfortable listening levels were obtained for stimuli that varied in presumed electrical field size by using the partial tripolar configuration, for which a fraction of current (σ) from a center active electrode returns through two neighboring electrodes and the remainder through a distant indifferent electrode. EABRs were obtained in each subject for the two channels having the highest and lowest tripolar (σ = 1 or 0.9) behavioral threshold. Evoked potentials were measured with both the monopolar (σ = 0) and a more focused partial tripolar (σ ≥ 0.50) configuration. Results: Consistent with previous studies, EABR thresholds were highly and positively correlated with behavioral thresholds obtained with both the monopolar and partial tripolar configurations. The Wave V amplitude growth functions with increasing stimulus level showed the predicted effect of shallower growth for the partial tripolar than for the monopolar configuration, but this was observed only for the low-threshold channels. In contrast, high-threshold channels showed the opposite effect; steeper growth functions were seen for the partial tripolar configuration. Conclusions: These results suggest that behavioral thresholds or EABRs measured with a restricted stimulus can be used to identify potentially impaired cochlear implant channels. Channels having high thresholds and steep growth functions would likely not activate the appropriate spatially restricted region of the cochlea, leading to suboptimal perception. As a clinical tool, quick identification of impaired channels could lead to patient-specific mapping strategies and result in improved speech and music perception.