SAScott C. Aker

Scott C. Aker

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Scott C. Aker has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Effect of Etiology, Array Type and Duration of Deafness on Focused Detection Thresholds in Cochlear Implant Listeners

    by Caylin McCallick, Scott C. Aker, Heather A. Kreft, Tina Munjal, Andrew J. Oxenham, Julie G. Arenberg

    Cochlear implants (CIs) are considered effective at restoring some hearing abilities to individuals with severe hearing loss. However, there is considerable variability in performance outcomes among adults with CIs. One likely source of variability is the quality of the electrode-neuron interface (ENI), which describes how well implanted electrodes stimulate nearby spiral-ganglion neurons (SGNs) in the cochlea. Absolute thresholds, measured via focused electrical stimulation, have been proposed as a behavioral estimate of ENI. In this retrospective study, focused-stimulation threshold patterns were compared for 92 ears from 74 adult cochlear implant listeners with various etiologies, durations of deafness, and electrode array types. The results showed that CI listeners implanted with a pre-curved array tended to have lower overall focused thresholds than listeners with straight arrays, as well as a threshold profile with lower (better) thresholds at each end of the array and highest thresholds near the middle of the array. CI listeners with etiologies related to auto-immune dysfunction, such as Meniere’s disease, tended to have the opposite profile, with lowest thresholds near the middle of the array. No significant effect of duration of deafness on focused thresholds was observed. Further investigation into which demographic and device factors affect focused thresholds, and therefore potentially ENI, could shed light on the variability of CI outcomes and guide development of individualized treatment strategies.

  • Open Access

    Perceived auditory dynamic range is enhanced with wrist-based tactile stimulation

    by Scott C. Aker, Kathleen F. Faulkner, Hamish Innes-Brown, Jeremy Marozeau

    Tactile stimulation has been shown to increase auditory loudness judgments in listeners. This bias could be utilized to enhance perception for people with deficiencies in auditory intensity perception, such as cochlear implant users. However, several aspects of this enhancement remain uncertain. For instance, does the tactile stimulation need to be applied to the hand or body, or can it be applied to the wrist? Furthermore, can the tactile stimulation both amplify and attenuate the perceived auditory loudness? To address these questions, two loudness-matching experiments were conducted. Participants matched a comparison auditory stimulus with an auditory reference, either with or without spectro-temporally identical tactile stimulation. In the first experiment, fixed-level tactile stimulation was administered to the wrist during the comparison stimulus to assess whether perceived auditory loudness increased. The second experiment replicated the same conditions but introduced tactile stimulation to both the reference and comparison, aiming to investigate the potential decrease in perceived auditory loudness when the two tactile accompaniments were incongruent between the reference and comparison. The results provide evidence supporting the existence of the tactile loudness bias in each experiment and are a step towards wrist-based haptic devices that modulate the auditory dynamic range for a user.


  • Open Access

    Some, but not all, cochlear implant users prefer music stimuli with congruent haptic stimulation

    by Scott C. Aker, Kathleen F. Faulkner, Hamish Innes-Brown, Marianna Vatti, Jeremy Marozeau

    Cochlear implant (CI) users often report being unsatisfied by music listening through their hearing device. Vibrotactile stimulation could help alleviate those challenges. Previous research has shown that musical stimuli was given higher preference ratings by normal-hearing listeners when concurrent vibrotactile stimulation was congruent in intensity and timing with the corresponding auditory signal compared to incongruent. However, it is not known whether this is also the case for CI users. Therefore, in this experiment, we presented 18 CI users and 24 normal-hearing listeners with five melodies and five different audio-to-tactile maps. Each map varied the congruence between the audio and tactile signals related to intensity, fundamental frequency, and timing. Participants were asked to rate the maps from zero to 100, based on preference. It was shown that almost all normal-hearing listeners, as well as a subset of the CI users, preferred tactile stimulation, which was congruent with the audio in intensity and timing. However, many CI users had no difference in preference between timing aligned and timing unaligned stimuli. The results provide evidence that vibrotactile music enjoyment enhancement could be a solution for some CI users; however, more research is needed to understand which CI users can benefit from it most.


  • Open Access

    Effect of audio-tactile congruence on vibrotactile music enhancement

    by Scott C. Aker, Hamish Innes-Brown, Kathleen F. Faulkner, Marianna Vatti, Jeremy Marozeau

    Music listening experiences can be enhanced with tactile vibrations. However, it is not known which parameters of the tactile vibration must be congruent with the music to enhance it. Devices that aim to enhance music with tactile vibrations often require coding an acoustic signal into a congruent vibrotactile signal. Therefore, understanding which of these audio-tactile congruences are important is crucial. Participants were presented with a simple sine wave melody through supra-aural headphones and a haptic actuator held between the thumb and forefinger. Incongruent versions of the stimuli were made by randomizing physical parameters of the tactile stimulus independently of the auditory stimulus. Participants were instructed to rate the stimuli against the incongruent stimuli based on preference. It was found making the intensity of the tactile stimulus incongruent with the intensity of the auditory stimulus, as well as misaligning the two modalities in time, had the biggest negative effect on ratings for the melody used. Future vibrotactile music enhancement devices can use time alignment and intensity congruence as a baseline coding strategy, which improved strategies can be tested against.