Rob Aspin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rob Aspin has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Farid Meziane
University of Derby
10 shared publications - Peter Hogg
University of Salford, United Kingdom
5 shared publications - Asaad F. Qasim
Ministry of Higher Education and Scientific Research, Studies, Planning and Follow-up Directorate, Baghdad, Iraq
3 shared publications - David Roberts
University of Salford
3 shared publications - Judith Kelly
The Countess of Chester Hospitals NHS Foundation Trust
3 shared publications - Ali Majeed Hasan
College of Medicine, Al-Nahrain University, Baghdad 10001, Iraq
2 shared publications
Latest Publications
- Open Access
- 13 October 2022
- Published by FSFEI HE Don State Technical University in Advanced Engineering Research (Rostov-on-Don)
- Vol. 22 (3) , 261-271
Describing Pulmonary Nodules Using 3D Clustering
Introduction. Determining the tumor (nodule) characteristics in terms of the shape, location, and type is an essential step after nodule detection in medical images for selecting the appropriate clinical intervention by radiologists. Computer-aided detection (CAD) systems efficiently succeeded in the nodule detection by 2D processing of computed tomography (CT)-scan lung images; however, the nodule (tumor) description in more detail is still a big challenge that faces these systems.Materials and Methods. In this paper, the 3D clustering is carried out on volumetric CT-scan images containing the nodule and its structures to describe the nodule progress through the consecutive slices of the lung in CT images.Results. This paper combines algorithms to cluster and define nodule’s features in 3D visualization. Applying some 3D functions to the objects, clustered using the K-means technique of CT lung images, provides a 3D visual exploration of the nodule shape and location. This study mainly focuses on clustering in 3D to discover complex information for a case missed in the radiologist’s report. In addition, the 3D-Density-based spatial clustering of applications with noise (DBSCAN) method and another 3D application (plotly) have been applied to evaluate the proposed system in this work. The proposed method has discovered a complicated case in data and automatically provides information about the nodule types (spherical, juxta-pleural, and pleural-tail). The algorithm is validated on the standard data consisting of the lung computed tomography scans with nodules greater and less than 3mm in size.Discussion and Conclusions. Based on the proposed model, it is possible to cluster lung nodules in volumetric CT scan and determine a set of characteristics such as the shape, location and type.
- 13 October 2022
- Published by FSFEI HE Don State Technical University in Advanced Engineering Research (Rostov-on-Don)
- Vol. 22 (3) , 261-271
Open AccessDescribing Pulmonary Nodules Using 3D Clustering
Introduction. Determining the tumor (nodule) characteristics in terms of the shape, location, and type is an essential step after nodule detection in medical images for selecting the appropriate clinical intervention by radiologists. Computer-aided detection (CAD) systems efficiently succeeded in the nodule detection by 2D processing of computed tomography (CT)-scan lung images; however, the nodule (tumor) description in more detail is still a big challenge that faces these systems.Materials and Methods. In this paper, the 3D clustering is carried out on volumetric CT-scan images containing the nodule and its structures to describe the nodule progress through the consecutive slices of the lung in CT images.Results. This paper combines algorithms to cluster and define nodule’s features in 3D visualization. Applying some 3D functions to the objects, clustered using the K-means technique of CT lung images, provides a 3D visual exploration of the nodule shape and location. This study mainly focuses on clustering in 3D to discover complex information for a case missed in the radiologist’s report. In addition, the 3D-Density-based spatial clustering of applications with noise (DBSCAN) method and another 3D application (plotly) have been applied to evaluate the proposed system in this work. The proposed method has discovered a complicated case in data and automatically provides information about the nodule types (spherical, juxta-pleural, and pleural-tail). The algorithm is validated on the standard data consisting of the lung computed tomography scans with nodules greater and less than 3mm in size.Discussion and Conclusions. Based on the proposed model, it is possible to cluster lung nodules in volumetric CT scan and determine a set of characteristics such as the shape, location and type.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 202-207
Integration of Digital Watermarking Technique into Medical Imaging Systems
This paper presents the process of integrating digital watermarking technique into medical imaging workflow to evaluate, validate and verify its applicability and appropriateness to medical domains. This is significant to ensure the ability of the proposed approach to tackle security threats that may face medical images during routine medical practices. This work considers two key objectives within the aim of defining a secure and practical digital medical imaging system: current digital medical workflows are deeply analyzed to define security limitations in Picture Archiving and Communication Systems (PACS) of medical imaging; the proposed watermarking approach is then theoretically tested and validated in its ability to operate in a real-world scenario (e.g. PACS). These have been undertaken through identified case studies related to manipulations of medical images within PACS workflow during acquisition, viewing, exchanging and archiving. This work assures the achievement of the identified particular requirements of digital watermarking when applied to digital medical images and also provides robust controls within medical imaging pipelines to detect modifications that may be applied to medical images during viewing, storing and transmitting.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 202-207
Integration of Digital Watermarking Technique into Medical Imaging Systems
This paper presents the process of integrating digital watermarking technique into medical imaging workflow to evaluate, validate and verify its applicability and appropriateness to medical domains. This is significant to ensure the ability of the proposed approach to tackle security threats that may face medical images during routine medical practices. This work considers two key objectives within the aim of defining a secure and practical digital medical imaging system: current digital medical workflows are deeply analyzed to define security limitations in Picture Archiving and Communication Systems (PACS) of medical imaging; the proposed watermarking approach is then theoretically tested and validated in its ability to operate in a real-world scenario (e.g. PACS). These have been undertaken through identified case studies related to manipulations of medical images within PACS workflow during acquisition, viewing, exchanging and archiving. This work assures the achievement of the identified particular requirements of digital watermarking when applied to digital medical images and also provides robust controls within medical imaging pipelines to detect modifications that may be applied to medical images during viewing, storing and transmitting.
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A Computer-aided Diagnosis System for Glioma Grading using Three Dimensional Texture Analysis and Machine Learning in MRI Brain Tumour
Glioma grading is vital for therapeutic planning where the higher level of glioma is associated with high mortality. It is a challenging task as different glioma grades have mixed morphological characteristics of brain tumour. A computeraided diagnosis (CAD) system based on three-dimensional textural grey level co-occurrence matrix (GLCM) and machine learning is proposed for glioma grading. The purpose of this paper is to assess the usefulness of the 3D textural analysis in establishing a malignancy prediction model for glioma grades. Furthermore, this paper aims to find the best classification model based on textural analysis for glioma grading. The classification system was evaluated using leave-one-out cross-validation technique. The experimental design includes feature extraction, feature selection, and finally the classification that includes single and ensemble classification models in a comparative study. Experimental results illustrate that single and ensemble classification models, can achieve efficient prediction performance based on 3D textural analysis and the classification accuracy result has significantly improved after using feature selection methods. In this paper, we compare the proficiency of applying different angles of 3D textural analysis and different classification models to determine the malignant level of glioma. The obtained sensitivity, accuracy and specificity are 100%, 96.6%, 90% respectively. The prediction system presents an effective approach to assess the malignancy level of glioma with a non-invasive, reproducible and accurate CAD system for glioma grading.
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A Computer-aided Diagnosis System for Glioma Grading using Three Dimensional Texture Analysis and Machine Learning in MRI Brain Tumour
Glioma grading is vital for therapeutic planning where the higher level of glioma is associated with high mortality. It is a challenging task as different glioma grades have mixed morphological characteristics of brain tumour. A computeraided diagnosis (CAD) system based on three-dimensional textural grey level co-occurrence matrix (GLCM) and machine learning is proposed for glioma grading. The purpose of this paper is to assess the usefulness of the 3D textural analysis in establishing a malignancy prediction model for glioma grades. Furthermore, this paper aims to find the best classification model based on textural analysis for glioma grading. The classification system was evaluated using leave-one-out cross-validation technique. The experimental design includes feature extraction, feature selection, and finally the classification that includes single and ensemble classification models in a comparative study. Experimental results illustrate that single and ensemble classification models, can achieve efficient prediction performance based on 3D textural analysis and the classification accuracy result has significantly improved after using feature selection methods. In this paper, we compare the proficiency of applying different angles of 3D textural analysis and different classification models to determine the malignant level of glioma. The obtained sensitivity, accuracy and specificity are 100%, 96.6%, 90% respectively. The prediction system presents an effective approach to assess the malignancy level of glioma with a non-invasive, reproducible and accurate CAD system for glioma grading.
- 1 February 2019
- Published by Elsevier in Signal Processing: Image Communication
- Vol. 70, 246-258
Assessment of perceptual distortion boundary through applying reversible watermarking to brain MR images
- 1 February 2019
- Published by Elsevier in Signal Processing: Image Communication
- Vol. 70, 246-258
Assessment of perceptual distortion boundary through applying reversible watermarking to brain MR images
- Open Access
- 15 December 2018
- Published by Springer Nature in Multimedia Tools and Applications
- Vol. 78 (12) , 16433-16463
ROI-based reversible watermarking scheme for ensuring the integrity and authenticity of DICOM MR images
- 15 December 2018
- Published by Springer Nature in Multimedia Tools and Applications
- Vol. 78 (12) , 16433-16463
Open AccessROI-based reversible watermarking scheme for ensuring the integrity and authenticity of DICOM MR images
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A Reversible and Imperceptible Watermarking Scheme for MR Images Authentication
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A Reversible and Imperceptible Watermarking Scheme for MR Images Authentication
- 1 February 2018
- Published by Elsevier in Computer Science Review
- Vol. 27, 45-60
Digital watermarking: Applicability for developing trust in medical imaging workflows state of the art review
- 1 February 2018
- Published by Elsevier in Computer Science Review
- Vol. 27, 45-60
Digital watermarking: Applicability for developing trust in medical imaging workflows state of the art review
- 16 June 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1075) , 20160871
The impact of simulated motion blur on lesion detection performance in full-field digital mammography
Objective: Motion blur is a known phenomenon in full-field digital mammography, but the impact on lesion detection is unknown. This is the first study to investigate detection performance with varying magnitudes of simulated motion blur. Methods: 7 observers (15 ± 5 years' reporting experience) evaluated 248 cases (62 containing malignant masses, 62 containing malignant microcalcifications and 124 normal cases) for 3 conditions: no blurring (0 mm) and 2 magnitudes of simulated blurring (0.7 and 1.5 mm). Abnormal cases were biopsy proven. Mathematical simulation was used to provide a pixel shift in order to simulate motion blur. A free-response observer study was conducted to compare lesion detection performance for the three conditions. The equally weighted jackknife alternative free-response receiver operating characteristic was used as the figure of merit. Test alpha was set at 0.05 to control probability of Type I error. Results: The equally weighted jackknife alternative free-response receiver operating characteristic analysis found a statistically significant difference in lesion detection performance for both masses [F(2,22) = 6.01, p = 0.0084] and microcalcifications [F(2,49) = 23.14, p < 0.0001]. The figures of merit reduced as the magnitude of simulated blurring increased. Statistical differences were found between some of the pairs investigated for the detection of masses (0.0 vs 0.7 and 0.0 vs 1.5 mm) and all pairs for microcalcifications (0.0 vs 0.7, 0.0 vs 1.5 and 0.7 vs 1.5 mm). No difference was detected between 0.7 and 1.5 mm for masses. Conclusion: The mathematical simulation of motion blur caused a statistically significant reduction in lesion detection performance. These false-negative decisions could have implications for clinical practice. Advances in knowledge: This research demonstrates for the first time that motion blur has a negative and statistically significant impact on lesion detection performance in digital mammography.
- 16 June 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1075) , 20160871
The impact of simulated motion blur on lesion detection performance in full-field digital mammography
Objective: Motion blur is a known phenomenon in full-field digital mammography, but the impact on lesion detection is unknown. This is the first study to investigate detection performance with varying magnitudes of simulated motion blur. Methods: 7 observers (15 ± 5 years' reporting experience) evaluated 248 cases (62 containing malignant masses, 62 containing malignant microcalcifications and 124 normal cases) for 3 conditions: no blurring (0 mm) and 2 magnitudes of simulated blurring (0.7 and 1.5 mm). Abnormal cases were biopsy proven. Mathematical simulation was used to provide a pixel shift in order to simulate motion blur. A free-response observer study was conducted to compare lesion detection performance for the three conditions. The equally weighted jackknife alternative free-response receiver operating characteristic was used as the figure of merit. Test alpha was set at 0.05 to control probability of Type I error. Results: The equally weighted jackknife alternative free-response receiver operating characteristic analysis found a statistically significant difference in lesion detection performance for both masses [F(2,22) = 6.01, p = 0.0084] and microcalcifications [F(2,49) = 23.14, p < 0.0001]. The figures of merit reduced as the magnitude of simulated blurring increased. Statistical differences were found between some of the pairs investigated for the detection of masses (0.0 vs 0.7 and 0.0 vs 1.5 mm) and all pairs for microcalcifications (0.0 vs 0.7, 0.0 vs 1.5 and 0.7 vs 1.5 mm). No difference was detected between 0.7 and 1.5 mm for masses. Conclusion: The mathematical simulation of motion blur caused a statistically significant reduction in lesion detection performance. These false-negative decisions could have implications for clinical practice. Advances in knowledge: This research demonstrates for the first time that motion blur has a negative and statistically significant impact on lesion detection performance in digital mammography.
- Open Access
- 22 March 2017
- Published by Association for Computing Machinery (ACM)
- p. 1-5
MRI brain scan classification using novel 3-D statistical features
- 22 March 2017
- Published by Association for Computing Machinery (ACM)
- p. 1-5
Open AccessMRI brain scan classification using novel 3-D statistical features