CKCelal Fadil Kumru

Celal Fadil Kumru

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Celal Fadil Kumru has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • HIGH-SENSITIVITY DETECTION OF PARTIAL DISCHARGE-INDUCING VOIDS IN MEDIUM VOLTAGE XLPE CABLES USING A NOVEL SRR-BASED MICROWAVE SENSOR

    by Mustafa Yıldırım, Mahmut Ahmet Gözel, Celal Fadıl Kumru

    Air voids within the insulation layer of high-voltage power cables constitute a significant threat to system reliability by triggering partial discharge (PD) events, which can eventually lead to catastrophic insulation breakdown. In this study, a Split Ring Resonator (SRR) sensor based on the microwave resonance technique was designed and experimentally validated for the non-destructive detection of air voids in XLPE cable insulation. Distinct from existing literature, which predominantly utilizes antenna-based structures to capture PD signals via reflection coefficients (S11), this work employs a transmission line-based sensor to detect local dielectric changes directly through transmission parameter (S21) monitoring. The developed sensor induced significant resonance frequency shifts based on the principle that air voids reduce the effective dielectric constant. Experimental analyses demonstrated that the sensor possesses sufficient penetration depth to analyze the internal structure despite the shielding effects of the semiconductor layer and the outer protective sheath. In full-scale cable tests, the reference resonance frequency of 4.42 GHz shifted to 4.60 GHz for the dominant volumetric void, 4.56 GHz for the narrow void, and 4.54 GHz for the shallow void. With frequency differences reaching up to 460 MHz relative to the reference state, the sensor enabled both defect detection and characterization.

  • Open Access

    Numerical Assessment of Thermal Effects in Bundled Overhead Conductors for Dynamic Line Rating

    by Ziauddin Zia, Celal Fadil Kumru

    Dynamic Line Rating (DLR) is increasingly important for maximizing capacity of existing overhead transmission lines. Conventional thermal rating methods, such as IEEE 738 and model conductors as single, isothermal cylinders and offer limited guidance for multi-conductor bundles, not fully capturing the complex aerodynamic and thermal interactions present in high-voltage networks. This study addresses these limitations by presenting a high-fidelity, two-dimensional coupled thermal-fluid model developed in COMSOL Multiphysics 4.3b. Single and bundled configurations (two-conductor, three-conductor and four-conductor) are analyzed under steady-state conditions using the Shear Stress Transport (SST) turbulence model, accounting for sub-conductor spacing, wind speed, and interactions between temperature distribution and airflow. Simulation results are compared with ampacity calculations from relevant standards to evaluate limitations of simplified models. Results show that leeward conductors reach temperatures up to ~4 °C higher than windward conductors, forming the thermal bottleneck, with peak temperatures of ~103.3 °C versus ~99 °C for single conductors. For bundled conductors, the current required to keep the maximum temperature at 100 °C was calculated, and this value was found to be approximately 3% lower than the current predicted by IEEE 738. The study emphasizes the importance of multiphysics, position-aware simulations to prevent overloading and optimize transmission line utilization.


  • Open Access

    Assessing Ampacity Performance Through Dynamic Line Rating: A Comparison of IEEE Std 738 and CIGRÉ TB 601

    by Ziauddin Zia, Celal Fadil Kumru

    Overhead transmission lines (TLs) are typically rated using static methods that assume conservative environmental conditions, such as high ambient temperatures and low wind speeds. These conservative ratings often result in underutilization of the line’s full ampacity, as extreme conditions occur only intermittently. Dynamic line rating (DLR) addresses this issue by utilizing real-time weather and grid load data to dynamically calculate the available ampacity, considering favorable environmental conditions. The DLR continuously updates ampacity calculations, allowing operators to access unused capacity when conditions are more favorable. This approach improves transmission efficiency and enhances grid reliability, ensuring a more adaptive and resilient power system. By integrating real-time weather data, DLR provides a more accurate representation of a TL’s actual capacity than static ratings. Both IEEE and CIGRÉ standards employ the heat balance equation to calculate ampacity, accounting for heat absorption and dissipation. This paper compares the methodologies outlined in IEEE Std 738 and CIGRÉ TB 601, focusing on their approaches to calculating conductor temperature and ampacity. The study examines the impact of different modeling approaches on ampacity calculations and the performance of TLs. The analysis shows significant differences between the two methods. In summer, the IEEE method increases ampacity by 47.2% compared to static line rating (SLR), while the CIGRÉ method increases it by 46.5%. In winter, the IEEE method shows a 36.9% increase, and CIGRÉ shows a 38.6% increase. These results demonstrate the potential of DLR to optimize transmission capacity and improve grid performance by adapting to real-time environmental conditions. Seasonal variations further highlight how factors like temperature and wind speed impact ampacity, reinforcing the value of DLR systems for maximizing TL efficiency year-round. Cite this article as: Z. Zia and C. F. Kumru, "Assessing ampacity performance through dynamic line rating: A comparison of IEEE std 738 and CIGRÉ TB 601," Electrica, 2025, 25, 0109, doi: 10.5152/electrica.2025.25109.


  • CapsPDNet: Optimized Capsule Network for Predicting Insulator Discharges Using UHF Signals

    by Mohammad AlShaikh Saleh, Ahmad Darwish, Ali Ghrayeb, Shady S. Refaat, Haitham Abu-Rub, Sunil P. Khatri, Ayman H. El-Hag, Celal F. Kumru

    Outdoor insulation systems often suffer from partial discharge (PD) faults that compromise the reliability of electrical grids. This paper proposes an integrated approach combining a non-invasive downsized discone antenna to capture ultra-high-frequency signals and an optimized capsule network (CapsPDNet) for robust PD fault prediction. The CapsPDNet is chosen as it overcomes the information loss associated with pooling operations and leverages vector representations, providing more nuanced predictions than scalar values, especially when the predictions are made across different antenna locations. Three typical PD fault types are targeted, surface discharges on ceramic and polymeric materials, internal discharges, and corona discharges, and then multiple signal processing techniques are evaluated to determine the most effective feature extraction and reconstruction technique. Experimental results show that the proposed model achieves up to a 18.89% improvement in PD fault prediction accuracy over benchmark approaches, demonstrating high generalizability and scalability when considering different antenna locations. The patented antenna used in this study offers a compact size through a novel size reduction technique, covers a wide bandwidth, and exhibits high sensitivity to PD activities. Additionally, discrete wavelet decomposition (DWT) is chosen as the feature extractor as it provides high-importance features with the lowest computational time, offering a more reliable and scalable solution for early PD fault detection and real-time condition monitoring of insulation systems.


  • Open Access

    Finite Element Method Based Design of a Computer Application Interface for Thermal Analysis of Underground Power Cable System

    by Celal Fadıl Kumru

    The aim of thermal analysis of underground power cable studies is to optimize electrical and physical parameters of cable system and to transfer maximum power with minimum losses. For such problems, finite element method is mostly preferred, since they have complex geometry and requires multi-disciplinary (thermal and electrical) study. However, design, calculation and analysis of the problem is quite challenging since it requires advanced knowledge in related areas. Therefore, it becomes difficult particularly for engineers and students to study on thermal analysis of underground cables which has an important role in power system. In this context, it is aimed to design an application to perform thermal analysis of a typical medium voltage underground cable system. The application is designed using Comsol Multiphysics and allows users to perform two-dimensional, time-dependent thermal analyses. It also provides users to set several thermal, electrical and physical parameters as inputs and allows to compare thermal distribution results at desired points and regions. In the study, a series of thermal analyses are performed and results are presented for a sample loading scenario to indicate performance of the application. Besides, the application designed is used as a training material in a seminar in Yildiz Technical University, Electrical Engineering Department. Results showed that the application can be used as a useful tool for engineering education.

  • Novel Antenna for Partial Discharge Detection and Classification: A Convolutional Neural Network-Based Deep Learning Approach

    by Ahmad Darwish, Shady S. Refaat, Haitham Abu-Rub, Hamid A. Toliyat, Celal F. Kumru, Farook Mustafa, Ayman H. El-Hag, Graeme Coapes, Sayed Mohammad Kameli

    Inspection of high voltage (HV) devices using ultra-high frequency (UHF) sensors has been predominantly employed for partial discharge (PD) detection and classification. This work reports implementing and testing a coplanar waveguide (CPW)-fed annular monopole antenna for PD detection. The 3D Maxwell solver of COMSOL multi-physics is used in this paper to optimize the antenna parameters and improve its performance. The original size of the antenna is reduced by about 47% utilizing structural symmetry and current resonances. The proposed antenna exhibits a wide bandwidth over frequencies ranging between 0.5 GHz - 3 GHz (except at 0.6 GHz, 1.2 GHz, and 2.75 GHz) due to the applied size reduction, using a maximum reflection coefficient of -10 dB (based on measurements). Nonetheless, the antenna performance is still effective over the full UHF range (considering that -6 dB is sufficient to detect PD activities). The effectiveness of the proposed antenna in PD detection is verified by testing the antenna’s performance against three common types of PD defects, namely, sharp point-to-ground discharge, surface discharge, and internal discharge. Furthermore, deep learning is implemented to classify the three defects with a total classification accuracy of 96%.


  • Open Access

    An EXPERIMENTAL STUDY ON DIELECTRIC PARAMETERS OF XLPE INSULATED HIGH VOLTAGE CABLES UNDER DIFFERENT OPERATING CONDITIONS

    by Celal Fadıl KUMRU, Celal Kocatepe

    High voltage underground cables used in distribution systems provide benefits including aesthetics, reliability, low maintenance costs, and resistance to environmental factors. However, their initial installation expenses are considerably higher than overhead lines, and fault detection is quite challenging. Thus, a deep analysis of dielectric parameters is crucial. Typically, electrical specifications of high voltage underground cables provided by the manufacturer are used for nominal operating conditions. However, it is essential to acknowledge that variations in operational conditions have a discernible impact on the dielectric characteristics of cable insulation. This phenomenon results in an accelerated aging process of the insulation material and contributes to unexpected failures. Hence, it is imperative to determine dielectric parameters of cable insulation under varying operational conditions and elucidate the impact of these operational states on insulation properties. This study involved experimental determination of the dielectric parameters, including capacitance, relative dielectric constant, dielectric loss, and tanδ, for a XLPE insulated high voltage underground cable, designed for a nominal voltage of 12/20 kV. These assessments were performed under varying operating conditions, specifically for distinct voltage, temperature, and frequency. Based on the acquired findings, it is evident that the dielectric characteristics of the cable insulation exhibit substantial variations in response to alterations in voltage, temperature, and frequency, even when operating within the defined nominal limits.


  • Open Access

    YÜKSEK GERİLİM LABORATUVARLARI İÇİN IoT TABANLI HAVA İSTASYONU TASARIMI VE UYGULAMASI

    by Celal Fadıl KUMRU, Muzaffer Samed Vural

    This study presents the design and implementation of an internet of things (IoT) based weather station for high voltage laboratories using the Raspberry Pi 4 Model B and two BME680 sensors. The weather station calculates the relative air density and humidity correction coefficients using the temperature, pressure, and relative humidity data obtained from the sensors. The study investigates the effect of the constant and real-time calculation of these coefficients on the measurement of AC, DC and lightning breakdown voltage using spherical electrodes. Measurements were performed within a laboratory setting for a period of 12 hours, and the obtained results were subsequently compared. The findings reveal that the real time calculation of the correction coefficients leads to a reduction in measurement errors. The study also includes the development of a web-based user interface using HTML and CSS, which is hosted on the Raspberry Pi 4 using the Flask web framework. This interface allows users to access the weather station data from any device with a web browser and provides real-time monitoring of the current coefficients, as well as the capability to calculate actual parameters online.


  • Open Access

    FARKLI YÜKLEME ŞARTLARI İÇİN XLPE İZOLELİ DENİZALTI KABLOLARININ ISIL ANALİZİ

    by Ahmet Yiğit ARABUL, Celal Fadıl KUMRU

    Submarine cables are critical assets that play an indispensable role in interconnected power systems, particularly in cross-sea energy transmission and offshore wind turbines. Their importance is further accentuated in exigent situations such as natural disasters and war, which emphasize the need for secure, reliable and uninterrupted energy supply. Furthermore, the investment and operating costs of submarine cables are relatively higher than other power system equipment, making it essential to operate them under the rated operating conditions to prevent possible faults and ensure power system stability. As thermal stress can lead to damage of cable insulation, it is an essential parameter to consider. Overloading increases thermal stress, resulting in rapid aging of the cable insulation and a shorter cable lifetime. Therefore, it is imperative to determine the maximum conductor temperatures and current carrying capacities of submarine cables under varying loading rates and ambient conditions using thermal analysis. In this study, thermal analyses are carried out for a three-phase, 220 kV HVAC, XLPE insulated submarine cable under different loading conditions. The findings demonstrate that the maximum temperature, current carrying capacity, and total losses of the cable are significantly impacted by loading rate, phase imbalance, and seawater temperature.