Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Cihat Cagdas Uydur has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Effect of Conductor Geometry on Electric Field Distribution in Air-Insulated Medium Voltage Busbar Systems

    by Ahmet Can Yalcin, Huseyin Akdemir, Cihat Cagdas Uydur, Bekir Dursun

    In the design processes of medium-voltage (MV) systems, ensuring insulation safety is considered a critical parameter in terms of both system sustainability and the service life of the components used. In this study, the direct effects of the cross-sectional geometry of conductors used in air-insulated switchgear (AIS) systems on electric field distribution and dielectric strength characteristics were quantitatively investigated through numerical analysis methods. Within the scope of the research, conductor models with different geometric structures were created based on a rated line-to-line voltage level of 17.5 kV, and these models were analyzed using the finite element method with COMSOL Multiphysics® (AC/DC Module 6.2 version) software under the rated peak inter-phase potential difference (24.75 kV). Simulation studies demonstrate that curved transitions at the rounded edges on conductor surfaces cause electric field lines to concentrate at these boundaries, leading to local electric field intensification. In calculations performed on a standard rectangular cross-section conductor with dimensions CU-6 × 180 mm, the maximum electric field strength reached 10.90 kV/cm at the rounded edges. For wider rectangular profiles such as CU-12 × 220 mm and CU-12 × 360 mm, maximum field strengths remained at 7.77 kV/cm and 7.42 kV/cm, respectively. In contrast, adopting equal-area cylindrical configurations for these profiles reduced the peak electric field to 4.54 kV/cm (for the 12 × 220 mm equivalent) and 4.22 kV/cm (for the 12 × 360 mm equivalent) owing to the uniform charge distribution across the continuous cylindrical boundary. Beyond the qualitative understanding of electrostatic curvature, this study quantitatively benchmarks the dielectric safety margins and field utilization factors for standardized industrial MV busbar profiles at 17.5 kV, providing practical geometric criteria for partial discharge mitigation in compact switchgear designs. The findings indicate that profile geometry serves as an effective design measure in mitigating electrical stress and reducing partial discharge risk in medium-voltage equipment.

  • Open Access

    Multi-Physics (Electromagnetic–Thermal–CFD) and Techno-Economic Analysis of Double-Neutral and Increased Cross-Section Scenarios in Harmonically Loaded Busbar Trunking Systems

    by Huseyin Akdemir, Ahmet Can Yalcin, Bekir Dursun, Cihat Cagdas Uydur

    In this study, the double-neutral (3P + 2N) configuration, considered a traditional solution for busbar systems subjected to overcurrent and thermal stresses under harmonic loads, and alternative cross-sectional expansion (from 6 mm × 55 mm to 6 mm × 65 mm) scenarios are investigated using a multidisciplinary approach. In this context, the electrical, electromagnetic, current density distributions, and magnetic flux densities (Bmax) of the systems are modeled in the COMSOL Multiphysics® (AC/DC Module 6.2 version) environment; the obtained q″ (W/m3) loss maps were transferred to FLOEFD convective airflow (CFD) simulations as volumetric heat sources, and steady-state electro-thermal analyses were performed. Convergence tests were conducted with the BiCGStab solver to ensure numerical stability, solver convergence, and spatial grid independence, and high accuracy was obtained at a margin of error of 3.5222 × 10−4. The findings showed that the proximity effect, due to the close placement of the pair of neutral conductors at the 150 Hz harmonic frequency, increased the current density to 4.68 A/mm2 and turned the neutral line into an additional heat source. In contrast, in the 4-conductor scheme where all conductor cross-sections were increased by 18.18%, the magnetic flux density at 150 Hz was suppressed from 27.21 mT to 23.50 mT, and the current density was distributed more homogeneously, optimizing the temperature rise limits (ΔT). Furthermore, the techno-economic cost analysis conducted revealed that, under premium scenarios for LME raw copper and processed bar copper, the application of increased cross-sectional area offered an optimization that was approximately 5.77% more economical per meter (approximately $36 USD for a standard 3 m length) compared to the double-neutral configuration. Consequently, it has been proven that in BTS designs, not only total harmonic distortion (THD) but also the triplen harmonic ratio, frequency-dependent AC resistance (Rac) variations, and material mass–cost balance should be considered together.

  • Open Access

    Analysis of Geometry-Dependent Skin Effect in High-Current Conductors: A Comparative Study of Busbar and Cable Geometries

    by Cihat Cagdas Uydur, Huseyin Akdemir, Ahmet Can Yalcin, Bekir Dursun

    Given the modernization of power systems in recent years, the quality of electrical energy is changing. With the increasing prevalence of harmonic components and rising current densities, conductor efficiency has become critically important. This study investigates the skin effect as a function of conductor geometry within the framework of electromagnetic field theory. Classical circular cross-section cable geometries and rectangular busbar systems were compared under an AC current of 1350 A (peak) across a frequency range of 50–500 Hz. The findings are comparatively presented, and their electromagnetic and thermal implications are discussed. Numerical modeling and simulation studies were performed using the Finite Element Method. COMSOL Multiphysics® software AC/DC Module 6.2 version was used for the analyses. In the simulation studies, the magnetic flux density distribution within the conductor and the current concentration induced by eddy currents were analyzed. Frequency-dependent behavioral characteristics were examined in the analyses. The results revealed that the conductor with circular geometry exhibited a more severe skin effect. The rectangular conductor used in busbar systems was found to effectively distribute the current density across its surface area. Thus, rectangular geometry optimizes AC resistance. The analysis results revealed that conductor design and material selection depend not only on the cross-sectional area but also on the geometric shape factor. In this context, it was determined that conductor design has a decisive effect on electromagnetic power losses, which directly govern the heat generation potential within high-current systems. This study serves as a technical guide to evaluate frequency-dependent electromagnetic performance across a 50–500 Hz range—reflecting frequencies relevant to harmonic components—to assist in the design and optimization of high-current energy distribution systems.

  • Open Access

    Induced Voltage-Based Optimization of Grounding Intervals for MV Busbar Enclosures

    by H. Akdemir, A. C. Yalcin, B. Dursun, C. C. Uydur

    Methods for establishing Medium-voltage (MV) grounding systems, which can be dangerous and costly, are typically based on traditional practices or on unscientific assumptions (e.g., fixed 10–20 meter intervals). Consequently, these methods fail to consider the geometry of conductors and high load currents which can lead to unsafe touch voltages and excessive installation costs. This research establishes a scientifically based method, grounded in the laws of physics and compliant with IEC 60364, for determining grounding connection intervals, and determines the electromagnetic coupling between phase conductors and metal enclosures using measured mutual inductance data and COMSOL Multiphysics simulations. This approach of has enabled the determination of the induced voltage gradients associated with MV busbar connection systems across various current levels (up to 5000 amps) and voltage classes (12-24 kV). Therefore, this research has provided an understanding of the physical characteristics that govern grounding system connections. The results indicate that the maximum safe grounding distances (Lmax), found to range from 120.3 m for 950 A systems to 33.5 m for high-capacity 5000 A systems, depend strongly on system design parameters. The sensitivity analysis indicates that Lmax is most influenced by fluctuations in load current and geometric clearances, and therefore provides practical guidance for incorporating strategic safety multipliers (0.8 and 0.6) into engineering applications. Additionally, this study provides a scalable framework to ensure that all grounding system designs meet the 50 V safety standard while minimizing over-engineering. In addition, this study enables the application of experimental or experience-based knowledge to the design of modern electrical infrastructure, going beyond simple estimates and providing a scientific framework for grounding system designs.

  • Open Access

    Exploring High Voltage Potential of 3D Printed Capacitors: A Filament-Based Comparison Through Dielectric Performance Analysis

    by Cihat Cagdas Uydur, Firat Akin

    Recent advancements in 3D printing technology have enabled the rapid production of complex structures, yet the dielectric performance of 3D printing materials and their potential for manufacturing electrical components remain insufficiently studied. In this study, a capacitor rated at 10 kV with a capacitance of 1 nF was designed and developed for high-voltage applications. During the production of the capacitor, the insulating and conductive parts were fabricated using a 3D printer. While PLA, ABS, ASA, and PETG were employed as insulating materials, aluminum was chosen as the conductive part. Theoretical calculations and the finite element method were used to validate the measured capacitance of the equipment. The performance of the prototype capacitor was analyzed through partial discharge inception voltages (PDIV), dissipation factor (tanδ), and breakdown voltage measurements. Dissipation factor measurements were performed at 2 and 4 kV voltages in the 50–400 Hz frequency range. The performance of employed materials was comparatively analyzed through experimental and simulation results. Finally, the impact of different insulating materials on the dielectric performance of the prototype capacitors was evaluated.


  • Open Access

    Assessment of Dielectric Strength for 3D Printed Solid Materials in Terms of Insulation Coordination

    by Cihat Cagdas Uydur

    Insulating materials can be classified into solid, liquid, and gaseous forms. Solid insulation materials are divided into different types such as organic, inorganic, and polymer types. In electrical circuits, solid insulation materials are generally used as components that provide insulation and mechanical support. In recent years, as a result of developing technologies, the production of participation insulation materials with 3D printing technology has become widespread. Three-dimensional printing technology enables the rapid creation of objects by combining materials based on digital model data. It is important to evaluate the materials produced with 3D printing in terms of insulation coordination. Studies have shown that the electrical breakdown strength of solid dielectrics varies depending on factors such as sample type, thickness, the magnitude of applied voltage, and the temperature of the physical environment. According to IEC-60243 standards, there are various methods to measure the breakdown strength of solid insulators applied to different voltage types. In this study, the behavior of PLA, ABS, ASA, PETG, and PC/ABS materials produced with 3D printing and having the potential to be used as insulation materials when exposed to high voltage within the scope of insulation coordination was investigated. The breakdown strengths of solid insulation materials produced with 3D printing were measured in the high-voltage laboratory within the scope of IEC-60243. Breakdown strength was statistically evaluated with the Weibull distribution. Damage analysis of the breakdowns in the test specimens was examined in detail with ImageJ software. With the comparative analysis, the behaviors of PLA, ABS, ASA, PETG, and PC/ABS solid insulation materials were revealed and their superiority over each other was determined.


  • Assessment of Electricity Consumption Characteristic: Textile Factory Case Study

    by Cihat Çağdaş Uydur

    Currently, electrical energy tariffs are a crucial factor in the electricity market, as they significantly impact the decisions made by end users. They play a vital role in the effectiveness of energy management systems (EMS). Tariffs are not solely considered a fixed component of expenditure calculations. Instead, they are indirectly linked to the costs of power generation, electricity transmission, and electricity distribution, as well as other determinants such as government taxation. In certain regions, improper tariff calculation methodologies have resulted in substantial power losses, superluous investments, increased operating costs, and environmental pollution because of the underutilization of available renewable energy sources. This study examined the electrical energy consumption values and characteristics of an integrated textile factory. Additionally, analyses were conducted on the electricity tariffs published by the Energy Market Regulatory Authority (EMRA) Electricity Energy Market management, in order to decrease the electrical energy consumption costs of the textile factory. Based on the findings of the analyses, suggestions were put forward for regulating the electrical energy consumption characteristics and reducing the electrical energy consumption costs.


  • Open Access

    Simulation and Experimental Development of 100 kV Impulse Voltage Generator

    by Cihat Cagdas Uydur

    The disruptive effects on energy transmission and distribution systems are caused by transient voltage increases that affect the grid in natural or indirect ways. The most important of these are lightning impulse voltages that occur in nature and switching impulse voltages caused by opening and closing operations in the grid. The design of power systems is done to minimize the effects of these types of transient voltages. However, unpredictable excessive voltage magnitudes or insulation weaknesses of equipment in the system can still cause serious damage to the entire system. Therefore, the design of equipment used in power systems is carried out in accordance with the concept and standards of insulation coordination, and the equipment produced is tested in laboratory conditions according to the excessive voltages that can occur in the grid before being used in the grid. In this study, the lightning impulse generator located in High Voltage Laboratory at Yildiz Technical University has been reviewed and developed for its intended use. Changes have been made in the structure of the impulse voltage generator so that 100 kV lightning impulse generator can apply lightning impulse voltage consecutively every 15 seconds. The values of the required circuit elements were recalculated and tested with a simulation study using MATLAB/Simulink software program. By creating circuit parameters whose suitability was verified by calculated and simulation studies, a lightning impulse generator was developed in the laboratory environment. The modified impulse voltage generator was experimentally tested on different samples. As a result, the theoretical findings obtained from the simulation study were also experimentally confirmed.


  • Open Access

    Load Forecasting for Trakya University

    by Cihat Cagdas Uydur, Firat Akin, Sureyya Guclu, Bekir Dursun

    Electricity demand prediction involves analyzing historical and current electricity usage, identifying factors influencing load estimation, and employing various methods and algorithms to project future demand. The primary objective of demand forecasting is to deliver cost-effective, reliable, and highquality energy to consumers. To achieve this, electricity demand forecasting is segmented into different time periods, encompassing production, transmission, and distribution levels. Time-based classifications categorize load forecasting into very short-term, short-term, mid-term, and long-term forecasts, each serving specific planning purposes. Forecasts extending beyond a year are considered long-term, those spanning one week to one year are categorized as mid-term, forecasts covering one hour to one week are short-term, and estimates less than an hour fall under very short-term forecasts. The factors utilized to estimate electrical load vary based on the forecasting duration. Long-term load forecasting primarily relies on parameters like gross national product and population, while short-term load forecasting predominantly utilizes meteorological data. Electricity consumption fluctuates on an hourly basis throughout the day. Analyzing these consumption variations and forecasting power plant activity initiates with short-term load forecasting. An additional role of short-term load forecasting is optimizing energy usage economically. Addressing escalating energy requirements and ensuring sustainable energy supply commences with accurate load forecasting. Consequently, load forecasting applications are progressively gaining significance to meet the evolving energy demands. In this study, a short-term load forecast for Trakya University have been made. During the estimation and analysis processes, error rates have been revealed by using decision trees (DT), artificial neural networks (ANN) and least squares method (LSM). It is seen that the ANN algorithm comes to the forefront in predicting behavioral characteristics. The performance of the DT algorithm in behavior analysis is not unsuccessful. However, there is a higher margin of error in the prediction process using the DT algorithm compared to the ANN application. It has been revealed that LSM cannot be used as a load forecasting algorithm.