Francesco Pelella
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Francesco Pelella has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Luca Viscito
Department of Industrial Engineering, Università degli Studi di Napoli–Federico II, P.le Tecchio 80, 80125 Naples, Italy
6 shared publications - Alfonso William Mauro
Department of Industrial Engineering, Università degli Studi di Napoli–Federico II, P.le Tecchio 80, 80125 Naples, Italy
5 shared publications - Adelso Flaviano Passarelli
Department of Industrial Engineering, Università degli Studi di Napoli–Federico II, P.le Tecchio 80, 80125 Naples, Italy
2 shared publications - Alessandro Zanella
Centro Ricerche FIAT SCpA, 10043 Orbassano, Italy
2 shared publications - Belén Llopis-Mengual
Instituto Universitario de Investigación de Ingeniería Energética (IUIIE), Universitat Politècnica de València (UPV), Camino de Vera s/n, 46022 Valencia, Spain
2 shared publications - Emilio Navarro-Peris
Instituto Universitario de Investigación de Ingeniería Energética (IUIIE), Universitat Politècnica de València (UPV), Camino de Vera s/n, 46022 Valencia, Spain
2 shared publications
Latest Publications
- Open Access
- 14 May 2026
- Published by MDPI AG in Journal of Experimental and Theoretical Analyses
- Vol. 4 (2) , 18
Impact of Sensor Accuracy and Model Calibration on Simulation of Heat Pumps with Refrigerant Leakage Faults
Soft operational faults can noticeably degrade the performance of heat pumps and influence key monitored variables, emphasizing the need for reliable Fault Detection, Diagnosis, and Evaluation (FDDE) strategies. The BEYOND project tackles this challenge by analyzing simultaneous soft faults using a calibrated simulation model informed by data from a dedicated test rig. Achieving reliable results depends on both accurate measurements and proper model calibration. However, sensor uncertainty and errors in sub-models and correlations calibration can compromise model reliability. This work investigates the influence of measurement accuracy and calibration quality on both experimental variables and simulation outcomes for a residential air-to-water heat pump operating in cooling mode, with particular focus on refrigerant charge estimation. Two sensor configurations—“low accuracy” and “high accuracy”—are assessed, representing commercial- and laboratory-grade instruments, respectively, along with two corresponding calibration strategies. In the low-accuracy case, uncertainties around 10% were found for cooling capacity, energy efficiency ratio, and refrigerant mass flow rate, whereas high-accuracy setups reduced these to approximately 3%. Ultimately, the comparison between experimental and model-derived uncertainties confirms that achieving reliable predictions requires a balanced investment in both high-quality instrumentation and careful model calibration. Overall, this study serves as a crucial tool during the preliminary design of an experimental setup, assisting in the selection of a sensor suite that ensures not only the reliability of secondary variables and KPIs but also a robust and accurate calibration of physics-based models using the acquired experimental data.
- 14 May 2026
- Published by MDPI AG in Journal of Experimental and Theoretical Analyses
- Vol. 4 (2) , 18
Open AccessImpact of Sensor Accuracy and Model Calibration on Simulation of Heat Pumps with Refrigerant Leakage Faults
Soft operational faults can noticeably degrade the performance of heat pumps and influence key monitored variables, emphasizing the need for reliable Fault Detection, Diagnosis, and Evaluation (FDDE) strategies. The BEYOND project tackles this challenge by analyzing simultaneous soft faults using a calibrated simulation model informed by data from a dedicated test rig. Achieving reliable results depends on both accurate measurements and proper model calibration. However, sensor uncertainty and errors in sub-models and correlations calibration can compromise model reliability. This work investigates the influence of measurement accuracy and calibration quality on both experimental variables and simulation outcomes for a residential air-to-water heat pump operating in cooling mode, with particular focus on refrigerant charge estimation. Two sensor configurations—“low accuracy” and “high accuracy”—are assessed, representing commercial- and laboratory-grade instruments, respectively, along with two corresponding calibration strategies. In the low-accuracy case, uncertainties around 10% were found for cooling capacity, energy efficiency ratio, and refrigerant mass flow rate, whereas high-accuracy setups reduced these to approximately 3%. Ultimately, the comparison between experimental and model-derived uncertainties confirms that achieving reliable predictions requires a balanced investment in both high-quality instrumentation and careful model calibration. Overall, this study serves as a crucial tool during the preliminary design of an experimental setup, assisting in the selection of a sensor suite that ensures not only the reliability of secondary variables and KPIs but also a robust and accurate calibration of physics-based models using the acquired experimental data.
- Open Access
- 19 July 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 279
Thermo-economic optimization of vertical farms exploring multiple design options for the built environment and HVAC system
- 19 July 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 279
Open AccessThermo-economic optimization of vertical farms exploring multiple design options for the built environment and HVAC system
- Open Access
State-of-the-Art Methodologies for Self-Fault Detection, Diagnosis and Evaluation (FDDE) in Residential Heat Pumps
The European Union’s 2050 targets for decarbonization and electrification are promoting the widespread integration of heat pumps for space heating, cooling, and domestic hot water in buildings. However, their energy and environmental performance can be significantly compromised by soft faults, such as refrigerant leakage or heat exchanger fouling, which may reduce system efficiency by up to 25%, even with maintenance intervals every two years. As a result, the implementation of self-fault detection, diagnosis, and evaluation (FDDE) tools based on operational data has become increasingly important. The complexity and added value of these tools grow as they progress from simple fault detection to quantitative fault evaluation, enabling more accurate and timely maintenance strategies. Direct fault measurements are often unfeasible due to spatial, economic, or intrusiveness constraints, thus requiring indirect methods based on low-cost and accessible measurements. In such cases, overlapping fault symptoms may create diagnostic ambiguities. Moreover, the accuracy of FDDE approaches depends on the type and number of sensors deployed, which must be balanced against cost considerations. This paper provides a comprehensive review of current FDDE methodologies for heat pumps, drawing insights from the academic literature, patent databases, and commercial products. Finally, the role of artificial intelligence in enhancing fault evaluation capabilities is discussed, along with emerging challenges and future research directions.
Open AccessState-of-the-Art Methodologies for Self-Fault Detection, Diagnosis and Evaluation (FDDE) in Residential Heat Pumps
The European Union’s 2050 targets for decarbonization and electrification are promoting the widespread integration of heat pumps for space heating, cooling, and domestic hot water in buildings. However, their energy and environmental performance can be significantly compromised by soft faults, such as refrigerant leakage or heat exchanger fouling, which may reduce system efficiency by up to 25%, even with maintenance intervals every two years. As a result, the implementation of self-fault detection, diagnosis, and evaluation (FDDE) tools based on operational data has become increasingly important. The complexity and added value of these tools grow as they progress from simple fault detection to quantitative fault evaluation, enabling more accurate and timely maintenance strategies. Direct fault measurements are often unfeasible due to spatial, economic, or intrusiveness constraints, thus requiring indirect methods based on low-cost and accessible measurements. In such cases, overlapping fault symptoms may create diagnostic ambiguities. Moreover, the accuracy of FDDE approaches depends on the type and number of sensors deployed, which must be balanced against cost considerations. This paper provides a comprehensive review of current FDDE methodologies for heat pumps, drawing insights from the academic literature, patent databases, and commercial products. Finally, the role of artificial intelligence in enhancing fault evaluation capabilities is discussed, along with emerging challenges and future research directions.
- Open Access
Physical Model for the Simulation of an Air Handling Unit Employed in an Automotive Production Process: Calibration Procedure and Potential Energy Saving
A meticulous thermo-hygrometric control is essential for various industrial production processes, particularly those involving the painting phases of body-in-white, in which the air temperature and relative humidity in production boots must be limited in strict intervals to ensure the high quality of the final product. However, traditional proportional integrative derivative (PID) controllers may result in non-optimal control strategies, leading to energy wastage due to response delays and unnecessary superheatings. In this regard, predictive models designed for control can significantly aid in achieving all the targets set by the European Union. This paper focuses on the development of a predictive model for the energy consumption of an air handling unit (AHU) used in the paint-shop area of an automotive production process. The model, developed in MATLAB 2024b, is based on mass and energy balances within each component, and phenomenological equations for heat exchangers. It enables the evaluation of thermal powers and water mass flow rates required to process an inlet air flow rate to achieve a target condition for the temperature and relative humidity. The model was calibrated and validated using experimental data of a real case study of an automotive production process, obtaining mean errors of 16% and 31% for the hot and cold heat exchangers, respectively, in predicting the water mass flow rate. Additionally, a control logic based on six regulation thermo-hygrometric zones was developed, which depended on the external conditions of temperature and relative humidity. Finally, as the main outcome, several examples are provided to demonstrate both the applicability of the developed model and its potential in optimizing energy consumption, achieving energy savings of up to 46% compared to the actual baseline control strategy, and external boundary conditions, identifying an optimal trade-off between energy saving and operation feasibility.
Open AccessPhysical Model for the Simulation of an Air Handling Unit Employed in an Automotive Production Process: Calibration Procedure and Potential Energy Saving
A meticulous thermo-hygrometric control is essential for various industrial production processes, particularly those involving the painting phases of body-in-white, in which the air temperature and relative humidity in production boots must be limited in strict intervals to ensure the high quality of the final product. However, traditional proportional integrative derivative (PID) controllers may result in non-optimal control strategies, leading to energy wastage due to response delays and unnecessary superheatings. In this regard, predictive models designed for control can significantly aid in achieving all the targets set by the European Union. This paper focuses on the development of a predictive model for the energy consumption of an air handling unit (AHU) used in the paint-shop area of an automotive production process. The model, developed in MATLAB 2024b, is based on mass and energy balances within each component, and phenomenological equations for heat exchangers. It enables the evaluation of thermal powers and water mass flow rates required to process an inlet air flow rate to achieve a target condition for the temperature and relative humidity. The model was calibrated and validated using experimental data of a real case study of an automotive production process, obtaining mean errors of 16% and 31% for the hot and cold heat exchangers, respectively, in predicting the water mass flow rate. Additionally, a control logic based on six regulation thermo-hygrometric zones was developed, which depended on the external conditions of temperature and relative humidity. Finally, as the main outcome, several examples are provided to demonstrate both the applicability of the developed model and its potential in optimizing energy consumption, achieving energy savings of up to 46% compared to the actual baseline control strategy, and external boundary conditions, identifying an optimal trade-off between energy saving and operation feasibility.
- Open Access
Comparison between Physics-Based Approaches and Neural Networks for the Energy Consumption Optimization of an Automotive Production Industrial Process
The automotive production sector plays a significant role in the energy consumption of all the industrial sphere, which currently represents approximately 38% of the total global energy use. Especially in production sites with several manufacturing lines working in parallel, the occurrence of failures and anomalies or sudden changes in the production volume may require a re-scheduling of the entire production process. In this regard, a digital twin of each phase of the process would give several indications about the new re-scheduled manufacture in terms of energy consumption and the control strategy to adopt. Therefore, the main goal of this paper is to propose different modeling approaches to a degreasing tank process, which is a preliminary phase at automotive production sites before the application of paint to car bodies. In detail, two different approaches have been developed: the first is a physics-based thermodynamic approach, which relies on the mass and energy balances of the system analyzed, and the second is machine learning-based, with the calibration of several artificial neural networks (ANNs). All the investigated approaches were assessed and compared, and it was determined that, for this application and with the data at our disposal, the thermodynamic approach has better prediction accuracy, with an overall mean absolute error (MAE) of 1.30 °C. Moreover, the model can be used to optimize the heat source policy of the tank, for which it has demonstrated, with historical data, an energy saving potentiality of up to 30%, and to simulate future scenarios in which, due to company constraints, a re-scheduling of the production of more work shifts is required.
Open AccessComparison between Physics-Based Approaches and Neural Networks for the Energy Consumption Optimization of an Automotive Production Industrial Process
The automotive production sector plays a significant role in the energy consumption of all the industrial sphere, which currently represents approximately 38% of the total global energy use. Especially in production sites with several manufacturing lines working in parallel, the occurrence of failures and anomalies or sudden changes in the production volume may require a re-scheduling of the entire production process. In this regard, a digital twin of each phase of the process would give several indications about the new re-scheduled manufacture in terms of energy consumption and the control strategy to adopt. Therefore, the main goal of this paper is to propose different modeling approaches to a degreasing tank process, which is a preliminary phase at automotive production sites before the application of paint to car bodies. In detail, two different approaches have been developed: the first is a physics-based thermodynamic approach, which relies on the mass and energy balances of the system analyzed, and the second is machine learning-based, with the calibration of several artificial neural networks (ANNs). All the investigated approaches were assessed and compared, and it was determined that, for this application and with the data at our disposal, the thermodynamic approach has better prediction accuracy, with an overall mean absolute error (MAE) of 1.30 °C. Moreover, the model can be used to optimize the heat source policy of the tank, for which it has demonstrated, with historical data, an energy saving potentiality of up to 30%, and to simulate future scenarios in which, due to company constraints, a re-scheduling of the production of more work shifts is required.
- 1 November 2020
- Published by Elsevier in International Journal of Refrigeration
- Vol. 119, 195-205
Flow boiling heat transfer and pressure drop data of non-azeotropic mixture R455A in a horizontal 6.0 mm stainless-steel tube
- 1 November 2020
- Published by Elsevier in International Journal of Refrigeration
- Vol. 119, 195-205
Flow boiling heat transfer and pressure drop data of non-azeotropic mixture R455A in a horizontal 6.0 mm stainless-steel tube
- 1 October 2019
- Published by Elsevier in Applied Thermal Engineering
- Vol. 161
Experimental thermal and hydraulic characterization of R448A and comparison with R404A during flow boiling
- 1 October 2019
- Published by Elsevier in Applied Thermal Engineering
- Vol. 161
Experimental thermal and hydraulic characterization of R448A and comparison with R404A during flow boiling