Shogo Sonoda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shogo Sonoda has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Kazuya Nakamura
Faculty of Science and Technology, Sophia University, Tokyo, Japan
10 shared publications - Haruyuki Murakami
National Institutes for Quantum Science and Technology, Naka, Japan
8 shared publications Kotomi Yuinawa
Faculty of Science and Technology, Sophia University, Tokyo, Japan
5 shared publications- Tomoaki Takao
Faculty of Science and Technology, Sophia University, Tokyo, Japan
5 shared publications Kazuya Hamada
National Institutes for Quantum and Radiological Science and Technology, Naka, Japan
4 shared publications- Kazuya Hamada
National Institutes for Quantum Science and Technology, Naka, Japan
4 shared publications
Latest Publications
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-4
Improvement of the Quench Detection System for the PF Coils of JT-60SA
The JT-60SA superconducting coil system comprises 6 Equilibrium Field coils, 4 Central Solenoid modules, and 18 Toroidal Field coils. Detecting a quench correctly in superconducting coils is essential to avoid damage of the coil. During the last integrated commissioning test, spike-shaped voltage fluctuations were observed on the EF and CS quench detection (QD) voltages. The voltage fluctuations occurred when the currents in the EF and CS coils rapidly changed. Following a circuit analysis of the EF coils, it was found that the spike voltage originated at the input of the QD differential amplifier from a slight mismatch of the time constants of the resistance-capacitance (RC) noise filter circuit. The RC filter circuit had to be adjusted precisely to achieve the same time constant between the winding and the pickup coil. The reduction of spike noise was experimentally confirmed by adjusting the variable capacitor or resistor in the filter circuit.
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-4
Improvement of the Quench Detection System for the PF Coils of JT-60SA
The JT-60SA superconducting coil system comprises 6 Equilibrium Field coils, 4 Central Solenoid modules, and 18 Toroidal Field coils. Detecting a quench correctly in superconducting coils is essential to avoid damage of the coil. During the last integrated commissioning test, spike-shaped voltage fluctuations were observed on the EF and CS quench detection (QD) voltages. The voltage fluctuations occurred when the currents in the EF and CS coils rapidly changed. Following a circuit analysis of the EF coils, it was found that the spike voltage originated at the input of the QD differential amplifier from a slight mismatch of the time constants of the resistance-capacitance (RC) noise filter circuit. The RC filter circuit had to be adjusted precisely to achieve the same time constant between the winding and the pickup coil. The reduction of spike noise was experimentally confirmed by adjusting the variable capacitor or resistor in the filter circuit.
- 26 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-5
Estimation of Mutual Inductance Caused by Misalignment of JT-60SA TF Coil
The JT-60 Super Advanced (JT-60SA) was built as part of a project aimed at the early realization of fusion energy. The JT-60SA is used to support and complement work for ITER and to develop young fusion scientists and engineers. The superconducting coil system of the JT-60SA includes the toroidal field (TF) coils, equilibrium field (EF) coils, and central solenoid (CS) modules. Each TF coil is monitored by the quench detection voltage (QDV) system, which compares voltages at adjacent TF coils using a bridge circuit. The EF coils do not produce a voltage in the TF coils because, ideally, the TF coils are orthogonal to the EF coils. However, when the EF coils are energized, the QDV in the TF coils sometimes exceeds the threshold, falsely detecting quenches, which leads to the discharge of a TF current. It is believed that a magnetic flux from the EF coils passing through the TF coils may occur due to coil misalignment during installation and inadequate clearance design. As a result, an induced voltage could be generated in the TF coils. To understand how other coils influence the TF QDV system and to ensure the stable operation of the JT-60SA, it is crucial to investigate the cause of the induced voltage in the TF coils. In this study, a coil misalignment model was developed using finite element analysis software. This model was used to calculate the mutual inductance between the TF and EF coils. Furthermore, a circuit simulation model of the TF QDV system was created to quantitatively analyze the induced voltage caused by the misalignment of superconducting coils.
- 26 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-5
Estimation of Mutual Inductance Caused by Misalignment of JT-60SA TF Coil
The JT-60 Super Advanced (JT-60SA) was built as part of a project aimed at the early realization of fusion energy. The JT-60SA is used to support and complement work for ITER and to develop young fusion scientists and engineers. The superconducting coil system of the JT-60SA includes the toroidal field (TF) coils, equilibrium field (EF) coils, and central solenoid (CS) modules. Each TF coil is monitored by the quench detection voltage (QDV) system, which compares voltages at adjacent TF coils using a bridge circuit. The EF coils do not produce a voltage in the TF coils because, ideally, the TF coils are orthogonal to the EF coils. However, when the EF coils are energized, the QDV in the TF coils sometimes exceeds the threshold, falsely detecting quenches, which leads to the discharge of a TF current. It is believed that a magnetic flux from the EF coils passing through the TF coils may occur due to coil misalignment during installation and inadequate clearance design. As a result, an induced voltage could be generated in the TF coils. To understand how other coils influence the TF QDV system and to ensure the stable operation of the JT-60SA, it is crucial to investigate the cause of the induced voltage in the TF coils. In this study, a coil misalignment model was developed using finite element analysis software. This model was used to calculate the mutual inductance between the TF and EF coils. Furthermore, a circuit simulation model of the TF QDV system was created to quantitatively analyze the induced voltage caused by the misalignment of superconducting coils.
- 6 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-6
Effect of Cool-Down Speed on Temperature Distribution in the JT-60SA Superconducting Coil
The JT-60SA central solenoid (CS) module is cooled to the operating temperature by the gas and supercritical helium. The cool-down tests of center solenoid model coil (CSMC), manufactured to validate the CS module manufacturing process for JT-60SA, showed that the maximum temperature in the CSMC occurs at the innermost turn of the coil. In the JT-60SA cool-down operation, the temperature can only be measured at the flow pipes connected to the outlet and inlet. Therefore, the maximum temperature in the CS module, which has a flow path similar to that of the CSMC, cannot be measured directly. In this study, we developed an analytical model to estimate the temperature distribution for the helium, strands, and jacket in the conductor from the measurement of the JT-60SA CSMC cool-down test. When the inlet temperature of the CS module in the JT-60SA cool-down test in 2023 was used for the inlet temperature in the analytical model, the coil was safely cooled to the operating temperature. Furthermore, the maximum temperature difference in the CS module and the cool-down speed were evaluated when the inlet was adjusted to keep the temperature difference between the inlet and outlet constant.
- 6 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-6
Effect of Cool-Down Speed on Temperature Distribution in the JT-60SA Superconducting Coil
The JT-60SA central solenoid (CS) module is cooled to the operating temperature by the gas and supercritical helium. The cool-down tests of center solenoid model coil (CSMC), manufactured to validate the CS module manufacturing process for JT-60SA, showed that the maximum temperature in the CSMC occurs at the innermost turn of the coil. In the JT-60SA cool-down operation, the temperature can only be measured at the flow pipes connected to the outlet and inlet. Therefore, the maximum temperature in the CS module, which has a flow path similar to that of the CSMC, cannot be measured directly. In this study, we developed an analytical model to estimate the temperature distribution for the helium, strands, and jacket in the conductor from the measurement of the JT-60SA CSMC cool-down test. When the inlet temperature of the CS module in the JT-60SA cool-down test in 2023 was used for the inlet temperature in the analytical model, the coil was safely cooled to the operating temperature. Furthermore, the maximum temperature difference in the CS module and the cool-down speed were evaluated when the inlet was adjusted to keep the temperature difference between the inlet and outlet constant.
- 24 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Effects of Resonance Phenomenon on Voltage Between Conductors in JT-60SA PF Coils
The JT-60SA Poloidal Field (PF) coils system comprises four Central Solenoid (CS) modules and six Equilibrium Field (EF) coils, and the cryostat, vacuum vessel (VV), and stabilizing plate (SP) are installed around the PF coil. Evaluating the voltage between conductors in the PF coils is one of the most critical factors in the energized coil operation and the insulation design. The power supply voltage of the PF coils has some frequency components caused by the voltage control system. The resonance phenomena caused by the voltage fluctuations of the power supply induce a non-uniform voltage distribution in the coil. The locally concentrated voltage may exceed the withstand voltage of the insulation, affecting the operation of the JT-60SA. In this study, a circuital model was assembled including four CS modules and six EF coils, to estimate the resonance frequency effect into the coil voltage distribution. In addition, the effects of the cryostat, VV, and SP on the voltage between conductors in the PF coils were evaluated.
- 24 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Effects of Resonance Phenomenon on Voltage Between Conductors in JT-60SA PF Coils
The JT-60SA Poloidal Field (PF) coils system comprises four Central Solenoid (CS) modules and six Equilibrium Field (EF) coils, and the cryostat, vacuum vessel (VV), and stabilizing plate (SP) are installed around the PF coil. Evaluating the voltage between conductors in the PF coils is one of the most critical factors in the energized coil operation and the insulation design. The power supply voltage of the PF coils has some frequency components caused by the voltage control system. The resonance phenomena caused by the voltage fluctuations of the power supply induce a non-uniform voltage distribution in the coil. The locally concentrated voltage may exceed the withstand voltage of the insulation, affecting the operation of the JT-60SA. In this study, a circuital model was assembled including four CS modules and six EF coils, to estimate the resonance frequency effect into the coil voltage distribution. In addition, the effects of the cryostat, VV, and SP on the voltage between conductors in the PF coils were evaluated.
- 14 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-4
Experimental Study on Quench Protection Method for HTS Coil That Uses Cu Tape Co-Wound With HTS Tape
The authors previously proposed a quench protection method for a high-temperature superconducting (HTS) coil that uses Cu tape co-wound with HTS tape (Cu-CW method). In this method, when a quench occurs in the HTS coil, part of the current in the HTS coil is quickly transferred to the co-wound Cu tape coil by shorting the Cu coil with a resistor due to the tight magnetic coupling of both coils, and the hot-spot temperature of the HTS coil is reduced due to the quick reduction of the HTS coil current. The previous work showed by a numerical simulation that the method is effective to improve the quench protection performance compared with a commonly used detect and dump method (D&D method). In this work, the effectiveness of the method was studied by an experiment using small-scale test coils wound with yttrium barium copper oxide (YBCO) coated tapes to experimentally simulate quench behaviours of HTS coils of significant scale.
- 14 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-4
Experimental Study on Quench Protection Method for HTS Coil That Uses Cu Tape Co-Wound With HTS Tape
The authors previously proposed a quench protection method for a high-temperature superconducting (HTS) coil that uses Cu tape co-wound with HTS tape (Cu-CW method). In this method, when a quench occurs in the HTS coil, part of the current in the HTS coil is quickly transferred to the co-wound Cu tape coil by shorting the Cu coil with a resistor due to the tight magnetic coupling of both coils, and the hot-spot temperature of the HTS coil is reduced due to the quick reduction of the HTS coil current. The previous work showed by a numerical simulation that the method is effective to improve the quench protection performance compared with a commonly used detect and dump method (D&D method). In this work, the effectiveness of the method was studied by an experiment using small-scale test coils wound with yttrium barium copper oxide (YBCO) coated tapes to experimentally simulate quench behaviours of HTS coils of significant scale.
- 17 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-4
Enhanced Levitation Performance of Magnetic Levitation System Using HTS Racetrack Coil
We have studied a magnetic levitation system including an HTS bulk as magnetic shield. This system consists of a ferromagnetic rail, HTS bulks, and HTS coil. In this paper, the vertical attractive force was discussed in two types of the analytical models. First, the model with the racetrack coil was proposed. We analyzed the vertical attractive force depending on the length of the coil's straight section. As a results, the maximum vertical attractive force became large with increasing a straight section, and the force reached approximately 20 kg when the straight section was 1 m. Next, we proposed a scaled-up model which was a 10-fold scaled-up of the HTS racetrack coil, HTS bulk, and ferromagnetic rail assuming an actual train size. Here we considered that one vehicle body, whose weight was 25 t, was levitated by four racetrack coils. Hence the vertical attractive force of each racetrack coil needed to be about 6.25 t. According to the analysis, the maximum vertical attractive force was about 16 t. The force was generated by one racetrack coil. Therefore, the vertical attractive force was enough larger than the weight of the actual vehicle body.
- 17 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-4
Enhanced Levitation Performance of Magnetic Levitation System Using HTS Racetrack Coil
We have studied a magnetic levitation system including an HTS bulk as magnetic shield. This system consists of a ferromagnetic rail, HTS bulks, and HTS coil. In this paper, the vertical attractive force was discussed in two types of the analytical models. First, the model with the racetrack coil was proposed. We analyzed the vertical attractive force depending on the length of the coil's straight section. As a results, the maximum vertical attractive force became large with increasing a straight section, and the force reached approximately 20 kg when the straight section was 1 m. Next, we proposed a scaled-up model which was a 10-fold scaled-up of the HTS racetrack coil, HTS bulk, and ferromagnetic rail assuming an actual train size. Here we considered that one vehicle body, whose weight was 25 t, was levitated by four racetrack coils. Hence the vertical attractive force of each racetrack coil needed to be about 6.25 t. According to the analysis, the maximum vertical attractive force was about 16 t. The force was generated by one racetrack coil. Therefore, the vertical attractive force was enough larger than the weight of the actual vehicle body.
- 28 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-4
Study on Resonance Phenomenon Caused by Voltage Fluctuation of Power Supply in JT-60SA EF Coil
For the large research Tokamak JT-60SA, evaluating the withstand voltage between conductors is one of the most critical factors for the coil design. The power supply feeding the coil injects a wide spectrum of frequency components. The transient response and resonance phenomena induce a non-uniform voltage distribution in the coil. The transiently concentrated voltage can cause the insulation breakdown between conductors, and JT-60SA may not be able to operate safely. This study conducted an impulse test to evaluate the withstand voltage between adjacent conductors for an equilibrium field (EF) coil. The actual power supply voltage for the EF coil was measured to investigate the ramp rate (dv/dt) and frequency spectrum. In addition, based on the results of a resonance test of the EF dummy coil, a circuit simulation model for the EF coil was developed to evaluate the effect of the transient response and resonance phenomenon on the voltage in the coil. The results of this study provide fundamental data that can be used to ensure that the EF coil does not cause insulation breakdown.
- 28 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-4
Study on Resonance Phenomenon Caused by Voltage Fluctuation of Power Supply in JT-60SA EF Coil
For the large research Tokamak JT-60SA, evaluating the withstand voltage between conductors is one of the most critical factors for the coil design. The power supply feeding the coil injects a wide spectrum of frequency components. The transient response and resonance phenomena induce a non-uniform voltage distribution in the coil. The transiently concentrated voltage can cause the insulation breakdown between conductors, and JT-60SA may not be able to operate safely. This study conducted an impulse test to evaluate the withstand voltage between adjacent conductors for an equilibrium field (EF) coil. The actual power supply voltage for the EF coil was measured to investigate the ramp rate (dv/dt) and frequency spectrum. In addition, based on the results of a resonance test of the EF dummy coil, a circuit simulation model for the EF coil was developed to evaluate the effect of the transient response and resonance phenomenon on the voltage in the coil. The results of this study provide fundamental data that can be used to ensure that the EF coil does not cause insulation breakdown.
- 6 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-6
Estimation of Cool-Down Speed Affected by Mass Flow Rate and Inlet Pressure in JT-60SA CS Module
The JT-60SA central solenoid (CS) module is cooled to 4.5 K using liquid helium. This cool-down operation of the coil is planned to take about one month. During cool-down, the maximum temperature difference in the coil (dT C-M ) must be kept below 40 K to avoid excessive thermal stress. Thermometers are attached only at the inlet and outlet on the outer perimeter of the coil. However, because the maximum temperature inside the coil occurs near its inner edge, dT C-M cannot be measured directly. Hence, estimating dT C-M is important to allow the cool-down process to be completed within one month without excessive thermal stress on the CS. In the present study, based on the results of the JT-60SA cool-down test performed in 2020, a temperature simulation model of the CS module, including the strands, jacket, and He in the bundle and hole regions was created using MATLAB, and dT C-M was estimated during the cool-down test. This model was then used to evaluate the effect of the mass flow rate and inlet pressure on the cool-down speed.
- 6 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-6
Estimation of Cool-Down Speed Affected by Mass Flow Rate and Inlet Pressure in JT-60SA CS Module
The JT-60SA central solenoid (CS) module is cooled to 4.5 K using liquid helium. This cool-down operation of the coil is planned to take about one month. During cool-down, the maximum temperature difference in the coil (dT C-M ) must be kept below 40 K to avoid excessive thermal stress. Thermometers are attached only at the inlet and outlet on the outer perimeter of the coil. However, because the maximum temperature inside the coil occurs near its inner edge, dT C-M cannot be measured directly. Hence, estimating dT C-M is important to allow the cool-down process to be completed within one month without excessive thermal stress on the CS. In the present study, based on the results of the JT-60SA cool-down test performed in 2020, a temperature simulation model of the CS module, including the strands, jacket, and He in the bundle and hole regions was created using MATLAB, and dT C-M was estimated during the cool-down test. This model was then used to evaluate the effect of the mass flow rate and inlet pressure on the cool-down speed.
- 28 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
Increase of Thermal Stability Caused by High Thermal Conduction Fiber and Sheet in Conduction-Cooled HTS Coils
We have examined thermal stability in high-temperature superconducting (HTS) coils, focusing on thermal properties of coil's structural components. As the component materials, high thermal conduction fibers and sheets made from a liquid crystal polymer (LCP) were used. First, we fabricated an LCP fiber reinforced plastic (LCP-FRP), and experimentally estimated thermal conductivity of the LCP-FRP round rod at cryogenic temperature, and made sure the conductivity was high. Next, thermal strain of the LCP-FRP rod from room temperature to 77 K was measured. From the results, the LCP-FRP bar expanded to a longitudinal direction of the bar with the cool down. Finally, we made an experimental apparatus which simulated a part of the HTS coil, and inserted the LCP sheet or a GFRP sheet in the HTS coil model. When the model was heated by a local heater, temperature rise of the model having the LCP sheet was lower than that having the GFRP sheet. From those experimental results, we think that thermal stability of the HTS coil becomes better by using the LCP sheet for non-metallic structural component in the coil.
- 28 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
Increase of Thermal Stability Caused by High Thermal Conduction Fiber and Sheet in Conduction-Cooled HTS Coils
We have examined thermal stability in high-temperature superconducting (HTS) coils, focusing on thermal properties of coil's structural components. As the component materials, high thermal conduction fibers and sheets made from a liquid crystal polymer (LCP) were used. First, we fabricated an LCP fiber reinforced plastic (LCP-FRP), and experimentally estimated thermal conductivity of the LCP-FRP round rod at cryogenic temperature, and made sure the conductivity was high. Next, thermal strain of the LCP-FRP rod from room temperature to 77 K was measured. From the results, the LCP-FRP bar expanded to a longitudinal direction of the bar with the cool down. Finally, we made an experimental apparatus which simulated a part of the HTS coil, and inserted the LCP sheet or a GFRP sheet in the HTS coil model. When the model was heated by a local heater, temperature rise of the model having the LCP sheet was lower than that having the GFRP sheet. From those experimental results, we think that thermal stability of the HTS coil becomes better by using the LCP sheet for non-metallic structural component in the coil.
- 14 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-4
Investigation of Transient Response Caused by Power Supply on JT-60SA Central Solenoid
The JT-60SA power supply of the central solenoid (CS) module contains multiple frequency components, and the transient response phenomenon and the resonance phenomenon cause the voltage non-uniformity in the CS. There is thus a possibility that a local voltage between the conductors that is larger than the withstand voltage of the insulation between conductors will be occurred, and the insulation is damaged. Therefore, an estimation of the transient response phenomenon and the resonance phenomenon is important for verifying that the CS is electrically stable. In the present study, the power supply voltage of the JT-60SA CS module was measured, and the effect of the transient response and the resonance phenomenon on the voltage between CS conductors was evaluated using an analysis model that included CS (four modules), the current lead between the power supply and the CS, and the structures surrounding the CS. The simulation results show that when the actual power supply is applied to the CS, the maximum voltage between CS conductors affected by the transient response and the resonance phenomenon is lower than the withstand voltage of the insulation between CS conductors. The results of our analyses provide fundamental data that can be used to estimate the voltage distribution in the CS and thus ensure the electrical stability.
- 14 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-4
Investigation of Transient Response Caused by Power Supply on JT-60SA Central Solenoid
The JT-60SA power supply of the central solenoid (CS) module contains multiple frequency components, and the transient response phenomenon and the resonance phenomenon cause the voltage non-uniformity in the CS. There is thus a possibility that a local voltage between the conductors that is larger than the withstand voltage of the insulation between conductors will be occurred, and the insulation is damaged. Therefore, an estimation of the transient response phenomenon and the resonance phenomenon is important for verifying that the CS is electrically stable. In the present study, the power supply voltage of the JT-60SA CS module was measured, and the effect of the transient response and the resonance phenomenon on the voltage between CS conductors was evaluated using an analysis model that included CS (four modules), the current lead between the power supply and the CS, and the structures surrounding the CS. The simulation results show that when the actual power supply is applied to the CS, the maximum voltage between CS conductors affected by the transient response and the resonance phenomenon is lower than the withstand voltage of the insulation between CS conductors. The results of our analyses provide fundamental data that can be used to estimate the voltage distribution in the CS and thus ensure the electrical stability.