Kazuya Hamada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kazuya Hamada has a total of 102 co-authors. Here are the top co-authors by number of shared publications:
- Haruyuki Murakami
National Institutes for Quantum Science and Technology, Naka, Japan
9 shared publications - Kazuma Fukui
National Institutes for Quantum and Radiological Science and Technology, Naka, Japan
5 shared publications - Manfred Wanner
Fusion for Energy, Garching, Germany
5 shared publications - Valerio Tomarchio
Fusion for Energy, Garching, Germany
5 shared publications Guy Phillips
Broader Approach & Roadmap Project Unit, Fusion for Energy, Boltzmannstr. 2 Garching bei München
4 shared publications- Luca Novello
Fusion for Energy, Garching, Germany
4 shared publications
Latest Publications
- Open Access
- 1 April 2026
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1344 (1)
Performances of the JT-60SA cryogenic system in the integrated commissioning test
A tokamak-type fusion experimental machine, JT-60SA, has been constructed through an international collaboration between Japan and the European Union. The JT-60SA utilizes a superconducting magnet system and a helium refrigerator with an equivalent refrigeration power of 9.5 kW at 4.5 K, providing cold helium gas to cool the magnet system. The second integrated commissioning test for JT-60SA operations began in May 2023, and the magnet system cooled down to operation temperature (<5 K). For plasma experiments, the cryogenic system provided approximately 2 kg/s of supercritical helium to the magnet system, removing static heat loads such as radiation and conduction heat and dynamic heat loads due to AC losses in the conductors, eddy currents in the magnet structures, and joule heating of the joints. The cryogenic system was successfully operated, and the first plasma was achieved on 23 October 2023.
- 1 April 2026
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1344 (1)
Open AccessPerformances of the JT-60SA cryogenic system in the integrated commissioning test
A tokamak-type fusion experimental machine, JT-60SA, has been constructed through an international collaboration between Japan and the European Union. The JT-60SA utilizes a superconducting magnet system and a helium refrigerator with an equivalent refrigeration power of 9.5 kW at 4.5 K, providing cold helium gas to cool the magnet system. The second integrated commissioning test for JT-60SA operations began in May 2023, and the magnet system cooled down to operation temperature (<5 K). For plasma experiments, the cryogenic system provided approximately 2 kg/s of supercritical helium to the magnet system, removing static heat loads such as radiation and conduction heat and dynamic heat loads due to AC losses in the conductors, eddy currents in the magnet structures, and joule heating of the joints. The cryogenic system was successfully operated, and the first plasma was achieved on 23 October 2023.
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-4
Improvement of the Quench Detection System for the PF Coils of JT-60SA
The JT-60SA superconducting coil system comprises 6 Equilibrium Field coils, 4 Central Solenoid modules, and 18 Toroidal Field coils. Detecting a quench correctly in superconducting coils is essential to avoid damage of the coil. During the last integrated commissioning test, spike-shaped voltage fluctuations were observed on the EF and CS quench detection (QD) voltages. The voltage fluctuations occurred when the currents in the EF and CS coils rapidly changed. Following a circuit analysis of the EF coils, it was found that the spike voltage originated at the input of the QD differential amplifier from a slight mismatch of the time constants of the resistance-capacitance (RC) noise filter circuit. The RC filter circuit had to be adjusted precisely to achieve the same time constant between the winding and the pickup coil. The reduction of spike noise was experimentally confirmed by adjusting the variable capacitor or resistor in the filter circuit.
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-4
Improvement of the Quench Detection System for the PF Coils of JT-60SA
The JT-60SA superconducting coil system comprises 6 Equilibrium Field coils, 4 Central Solenoid modules, and 18 Toroidal Field coils. Detecting a quench correctly in superconducting coils is essential to avoid damage of the coil. During the last integrated commissioning test, spike-shaped voltage fluctuations were observed on the EF and CS quench detection (QD) voltages. The voltage fluctuations occurred when the currents in the EF and CS coils rapidly changed. Following a circuit analysis of the EF coils, it was found that the spike voltage originated at the input of the QD differential amplifier from a slight mismatch of the time constants of the resistance-capacitance (RC) noise filter circuit. The RC filter circuit had to be adjusted precisely to achieve the same time constant between the winding and the pickup coil. The reduction of spike noise was experimentally confirmed by adjusting the variable capacitor or resistor in the filter circuit.
- 26 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-5
Estimation of Mutual Inductance Caused by Misalignment of JT-60SA TF Coil
The JT-60 Super Advanced (JT-60SA) was built as part of a project aimed at the early realization of fusion energy. The JT-60SA is used to support and complement work for ITER and to develop young fusion scientists and engineers. The superconducting coil system of the JT-60SA includes the toroidal field (TF) coils, equilibrium field (EF) coils, and central solenoid (CS) modules. Each TF coil is monitored by the quench detection voltage (QDV) system, which compares voltages at adjacent TF coils using a bridge circuit. The EF coils do not produce a voltage in the TF coils because, ideally, the TF coils are orthogonal to the EF coils. However, when the EF coils are energized, the QDV in the TF coils sometimes exceeds the threshold, falsely detecting quenches, which leads to the discharge of a TF current. It is believed that a magnetic flux from the EF coils passing through the TF coils may occur due to coil misalignment during installation and inadequate clearance design. As a result, an induced voltage could be generated in the TF coils. To understand how other coils influence the TF QDV system and to ensure the stable operation of the JT-60SA, it is crucial to investigate the cause of the induced voltage in the TF coils. In this study, a coil misalignment model was developed using finite element analysis software. This model was used to calculate the mutual inductance between the TF and EF coils. Furthermore, a circuit simulation model of the TF QDV system was created to quantitatively analyze the induced voltage caused by the misalignment of superconducting coils.
- 26 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-5
Estimation of Mutual Inductance Caused by Misalignment of JT-60SA TF Coil
The JT-60 Super Advanced (JT-60SA) was built as part of a project aimed at the early realization of fusion energy. The JT-60SA is used to support and complement work for ITER and to develop young fusion scientists and engineers. The superconducting coil system of the JT-60SA includes the toroidal field (TF) coils, equilibrium field (EF) coils, and central solenoid (CS) modules. Each TF coil is monitored by the quench detection voltage (QDV) system, which compares voltages at adjacent TF coils using a bridge circuit. The EF coils do not produce a voltage in the TF coils because, ideally, the TF coils are orthogonal to the EF coils. However, when the EF coils are energized, the QDV in the TF coils sometimes exceeds the threshold, falsely detecting quenches, which leads to the discharge of a TF current. It is believed that a magnetic flux from the EF coils passing through the TF coils may occur due to coil misalignment during installation and inadequate clearance design. As a result, an induced voltage could be generated in the TF coils. To understand how other coils influence the TF QDV system and to ensure the stable operation of the JT-60SA, it is crucial to investigate the cause of the induced voltage in the TF coils. In this study, a coil misalignment model was developed using finite element analysis software. This model was used to calculate the mutual inductance between the TF and EF coils. Furthermore, a circuit simulation model of the TF QDV system was created to quantitatively analyze the induced voltage caused by the misalignment of superconducting coils.
- 23 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-7
Magnet Commissioning on the World's Biggest Operating Tokamak JT-60SA
JT-60SA is the world's biggest operating tokamak (R = 3, a = 1.2) having achieved a plasma volume of 160m3 in 2023. As the first of a new generation of large fusion experimental machines, its commissioning represents a unique opportunity to gain invaluable operational experience. The magnets form the backbone of any tokamak, and the superconducting magnet systems of JT-60SA play a critical role in allowing long pulse operation, essential for studying plasma behaviour in conditions relevant to reactor operation. The novel design of the NbTi Toroidal Field (TF) magnet, providing the main confinement field for the plasma, allows its 18 coils (each 7.5 m high) to expand radially when energized within their Outer Intercoil Structures, which in turn provide lateral support. The 100-tonne Nb3Sn Central Solenoid (CS) is key to driving current in the plasma while the six NbTi Equilibrium Field (EF) coils, up to 12m in diameter, shape and control it. The TF magnet was successfully operated at its full 2.25 T on-axis field in 2021, and in October 2023 all the magnets could be operated together to produce the first tokamak plasma. While individual components - such as a coils, power supplies or cryoplants - can be thoroughly tested in isolation, many critical aspects of their interaction can only be assessed during integrated commissioning, where all systems are operated together. This paper provides an overview of the magnet system integrated commissioning process and highlights key lessons learned, particularly regarding insulation integrity, Paschen testing, applied voltages, power circuit design, and quench detection.
- 23 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-7
Magnet Commissioning on the World's Biggest Operating Tokamak JT-60SA
JT-60SA is the world's biggest operating tokamak (R = 3, a = 1.2) having achieved a plasma volume of 160m3 in 2023. As the first of a new generation of large fusion experimental machines, its commissioning represents a unique opportunity to gain invaluable operational experience. The magnets form the backbone of any tokamak, and the superconducting magnet systems of JT-60SA play a critical role in allowing long pulse operation, essential for studying plasma behaviour in conditions relevant to reactor operation. The novel design of the NbTi Toroidal Field (TF) magnet, providing the main confinement field for the plasma, allows its 18 coils (each 7.5 m high) to expand radially when energized within their Outer Intercoil Structures, which in turn provide lateral support. The 100-tonne Nb3Sn Central Solenoid (CS) is key to driving current in the plasma while the six NbTi Equilibrium Field (EF) coils, up to 12m in diameter, shape and control it. The TF magnet was successfully operated at its full 2.25 T on-axis field in 2021, and in October 2023 all the magnets could be operated together to produce the first tokamak plasma. While individual components - such as a coils, power supplies or cryoplants - can be thoroughly tested in isolation, many critical aspects of their interaction can only be assessed during integrated commissioning, where all systems are operated together. This paper provides an overview of the magnet system integrated commissioning process and highlights key lessons learned, particularly regarding insulation integrity, Paschen testing, applied voltages, power circuit design, and quench detection.
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
JT-60SA Central Solenoid Conductor Hotspot Risk Analysis for High Voltage Protection
The upgrade to JT-60SA tokamak was conducted within a Europe-Japan collaboration agreement including superconducting magnets implementation. In 2021, an arcing issue on a coil led to an overall magnet insulation reinforcement against high voltage. The Central Solenoid (CS), less accessible for repair, deserving specific attention versus voltage exposure, a risk mitigation was considered to address fast discharge event, which results in the highest voltage application. Maximum voltage during discharge being proportional to the external dump resistance (RDUMP), it is aimed at decreasing this resistance by 30%, inducing a slower current decrease after a quench, therefore a higher Joule energy absorbed by conductor. This induces a higher temperature rise in the conductor, increasing the risk of thermo-mechanical degradation due to hotspot occurrence. A risk analysis is performed to better understand the impact on the conductor. A methodology is followed to define streamlined hotspot risk criteria, backed by rationale and references to support the establishment of those methodological elements. Thermo-hydraulic simulations on the CS magnet, that were extensively produced, are analyzed to ensure that even after dump resistance modification, the hotspot safety limits are still respected. For this, a reference case and associated parametric studies were explored using THEA code. Finally, a positive recommendation is issued to validate and implement the JT-60SA project team decision to decrease the CS magnet RDUMP. Further perspectives are also evaluated.
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
JT-60SA Central Solenoid Conductor Hotspot Risk Analysis for High Voltage Protection
The upgrade to JT-60SA tokamak was conducted within a Europe-Japan collaboration agreement including superconducting magnets implementation. In 2021, an arcing issue on a coil led to an overall magnet insulation reinforcement against high voltage. The Central Solenoid (CS), less accessible for repair, deserving specific attention versus voltage exposure, a risk mitigation was considered to address fast discharge event, which results in the highest voltage application. Maximum voltage during discharge being proportional to the external dump resistance (RDUMP), it is aimed at decreasing this resistance by 30%, inducing a slower current decrease after a quench, therefore a higher Joule energy absorbed by conductor. This induces a higher temperature rise in the conductor, increasing the risk of thermo-mechanical degradation due to hotspot occurrence. A risk analysis is performed to better understand the impact on the conductor. A methodology is followed to define streamlined hotspot risk criteria, backed by rationale and references to support the establishment of those methodological elements. Thermo-hydraulic simulations on the CS magnet, that were extensively produced, are analyzed to ensure that even after dump resistance modification, the hotspot safety limits are still respected. For this, a reference case and associated parametric studies were explored using THEA code. Finally, a positive recommendation is issued to validate and implement the JT-60SA project team decision to decrease the CS magnet RDUMP. Further perspectives are also evaluated.
- 22 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Gamma-Ray Irradiation Characteristics of an Organic Olefin-Based Thermosetting Dicyclopentadiene Resin Under Vacuum Atmosphere
An organic olefin-based thermosetting dicyclopentadiene (DCP) resin named TELENE was proposed as an impregnation material for Nb3Sn magnets to reduce the training. To verify the radiation resistance of the TELENE, gamma-ray irradiation experiments and three-point bending tests were conducted on the TELENE and the CTD-101K. The TELENE mixed with Gd2O2S powder was also applied for these measurements. The gamma-ray irradiation experiment was carried out up to nearly 20 MGy at room temperature using a Cobalt-60 source at the Takasaki Advanced Radiation Research Institute in Japan. For gamma irradiation in the absence of air, all resin samples were sealed in glass tubes and evacuated. The flexural strength and flexural modulus of each resin were measured by the three-point bending test before and after gamma-ray irradiation. The pure and mixed TELENE exhibits plastic deformation before the irradiation and can withstand larger strain than the CTD-101K. After irradiation, no decrease in flexural strength was observed up to 6 MGy for the pure TELENE and up to 17 MGy for the mixed TELENE. However, their strains at fracture decreased by more than 50% after 5 MGy irradiation.
- 22 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Gamma-Ray Irradiation Characteristics of an Organic Olefin-Based Thermosetting Dicyclopentadiene Resin Under Vacuum Atmosphere
An organic olefin-based thermosetting dicyclopentadiene (DCP) resin named TELENE was proposed as an impregnation material for Nb3Sn magnets to reduce the training. To verify the radiation resistance of the TELENE, gamma-ray irradiation experiments and three-point bending tests were conducted on the TELENE and the CTD-101K. The TELENE mixed with Gd2O2S powder was also applied for these measurements. The gamma-ray irradiation experiment was carried out up to nearly 20 MGy at room temperature using a Cobalt-60 source at the Takasaki Advanced Radiation Research Institute in Japan. For gamma irradiation in the absence of air, all resin samples were sealed in glass tubes and evacuated. The flexural strength and flexural modulus of each resin were measured by the three-point bending test before and after gamma-ray irradiation. The pure and mixed TELENE exhibits plastic deformation before the irradiation and can withstand larger strain than the CTD-101K. After irradiation, no decrease in flexural strength was observed up to 6 MGy for the pure TELENE and up to 17 MGy for the mixed TELENE. However, their strains at fracture decreased by more than 50% after 5 MGy irradiation.
- 21 March 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 215
Superconducting magnet operation in JT-60SA integrated commissioning test
- 21 March 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 215
Superconducting magnet operation in JT-60SA integrated commissioning test
- 25 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Exploring Operation Limits of JT-60SA Cryomagnet Operation: Integrated Commissioning Database Use for Modeling Analysis
In the framework of international development on fusion devices, the tokamak JT-60SA was equipped with superconducting magnets within a Europe-Japan collaboration. After a first integrated commissioning (IC) in 2021, another IC was conducted in 2023 reaching magnet energization levels compliant with 1 MA-class plasmas. The Toroidal Field (TF) coil system was loaded at nominal current and the Poloidal Field (PF) at 50% of nominal current. In the 2023 IC various energization pulse patterns were applied on PF coils to gain experience on the magnets control and protection system in operation conditions. Some tailored current pulses were applied to learn about PF coils coupling parameters and protection system, which sensitivity was found to be improved. In this environment, we developed tools and methods to model and predict the magnets behaviour to possibly identify coils limits in operation conditions. First step is with thermo-hydraulic evaluation of PF coil temperature safety margin evaluation along their pulsed current patterns. Second step is a first order analysis of the TF quench detection system sensitivity, found higher than expected to PF transients, and the contribution to possible mitigation measures to avoid spurious false positive detections. Both steps were benchmarked against experimental data collected during 2023 IC to consolidate models prediction capacities. Foreseen applications aim at checking plasma scenarios repetability rate or avoiding pulsed coil current to generate apparent fault signal in absence of real risk (mostly quench). The tools and methods are described and their rationales explained, together with their intrinsic limits and room for improvement.
- 25 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Exploring Operation Limits of JT-60SA Cryomagnet Operation: Integrated Commissioning Database Use for Modeling Analysis
In the framework of international development on fusion devices, the tokamak JT-60SA was equipped with superconducting magnets within a Europe-Japan collaboration. After a first integrated commissioning (IC) in 2021, another IC was conducted in 2023 reaching magnet energization levels compliant with 1 MA-class plasmas. The Toroidal Field (TF) coil system was loaded at nominal current and the Poloidal Field (PF) at 50% of nominal current. In the 2023 IC various energization pulse patterns were applied on PF coils to gain experience on the magnets control and protection system in operation conditions. Some tailored current pulses were applied to learn about PF coils coupling parameters and protection system, which sensitivity was found to be improved. In this environment, we developed tools and methods to model and predict the magnets behaviour to possibly identify coils limits in operation conditions. First step is with thermo-hydraulic evaluation of PF coil temperature safety margin evaluation along their pulsed current patterns. Second step is a first order analysis of the TF quench detection system sensitivity, found higher than expected to PF transients, and the contribution to possible mitigation measures to avoid spurious false positive detections. Both steps were benchmarked against experimental data collected during 2023 IC to consolidate models prediction capacities. Foreseen applications aim at checking plasma scenarios repetability rate or avoiding pulsed coil current to generate apparent fault signal in absence of real risk (mostly quench). The tools and methods are described and their rationales explained, together with their intrinsic limits and room for improvement.
- 13 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Development of the Protection System for JT-60SA Superconducting Magnet Against Vacuum Degradation
The JT-60SA project succeeded in commissioning test toward the first plasma in 2023 under a framework: the Satellite Tokamak Programme of the Broader Approach Agreement between EU and Japan (H. Shirai et al., 2016). JT-60SA is a tokamak type magnetic confinement device with a superconducting magnet system (Y. Koide et al., 2015) developed and operated at the Quantum Science and Technology institute (QST) in Japan. The magnet system consists of 18 Toroidal Field coils, 6 Equilibrium Field coils, and 4 modules of Central Solenoids, and all the coils are superconducting magnets. In the first commissioning, during 2020 - 2021, JT-60SA has experienced a discharge incident at the EF1 magnet (H. Shirai et al., 2024). As a conclusion of the investigation of the incident, it turned out that the insulation resistance of the magnet system was insufficient. Although the insulation was partly reinforced, the voltage holding under accidentally arising Paschen conditions was not improved enough for the recent operation (OP-1, 2023) (K. Hamada et al., 2024). To prevent the magnet system from discharging during vacuum degradation, a vacuum monitoring system must be prepared to detect vacuum degradation and ramp down the magnet current immediately in case of unexpected vacuum degradation. In this article, the development of the vacuum monitoring system, operational results, and the future plan of the system will be described.
- 13 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Development of the Protection System for JT-60SA Superconducting Magnet Against Vacuum Degradation
The JT-60SA project succeeded in commissioning test toward the first plasma in 2023 under a framework: the Satellite Tokamak Programme of the Broader Approach Agreement between EU and Japan (H. Shirai et al., 2016). JT-60SA is a tokamak type magnetic confinement device with a superconducting magnet system (Y. Koide et al., 2015) developed and operated at the Quantum Science and Technology institute (QST) in Japan. The magnet system consists of 18 Toroidal Field coils, 6 Equilibrium Field coils, and 4 modules of Central Solenoids, and all the coils are superconducting magnets. In the first commissioning, during 2020 - 2021, JT-60SA has experienced a discharge incident at the EF1 magnet (H. Shirai et al., 2024). As a conclusion of the investigation of the incident, it turned out that the insulation resistance of the magnet system was insufficient. Although the insulation was partly reinforced, the voltage holding under accidentally arising Paschen conditions was not improved enough for the recent operation (OP-1, 2023) (K. Hamada et al., 2024). To prevent the magnet system from discharging during vacuum degradation, a vacuum monitoring system must be prepared to detect vacuum degradation and ramp down the magnet current immediately in case of unexpected vacuum degradation. In this article, the development of the vacuum monitoring system, operational results, and the future plan of the system will be described.
- Open Access
- 20 September 2024
- Published by Cryogenic Association of Japan in Teion Kogaku (Journal of Cryogenics and Superconductivity Society of Japan)
- Vol. 59 (5) , 289-296
Integrated Commissioning Test of JT-60SA Magnet and Cryogenic Systems:
JT-60SA cryogenic system comprises a main refrigerator cold box, auxiliary cold box, warm helium compressor, control system, and utility system (cooling water and instrumentation air). The total equivalent refrigerator power is 9.5 kW at 4.5 K. The cryogenic system supplied 4.4 K supercritical helium to the magnet system, 50 K pressurized helium gas to high-temperature superconducting current lead, and 80 K pressurized helium gas to the thermal shield. Before cooldown, cryostat helium leak testing and helium gas purification were performed. It took approximately 41 days to cool the magnet system from room temperature to superconducting transition temperature. During operation, the refrigerator was stopped three times because of electrical grounding problems and incorrect control parameter values in the cold rotation machine control system. Except for problems, the cryogenic system was steadily operated. This paper describes the cryogenic system operation results during cooldown and magnet operation.
- 20 September 2024
- Published by Cryogenic Association of Japan in Teion Kogaku (Journal of Cryogenics and Superconductivity Society of Japan)
- Vol. 59 (5) , 289-296
Open AccessIntegrated Commissioning Test of JT-60SA Magnet and Cryogenic Systems:
JT-60SA cryogenic system comprises a main refrigerator cold box, auxiliary cold box, warm helium compressor, control system, and utility system (cooling water and instrumentation air). The total equivalent refrigerator power is 9.5 kW at 4.5 K. The cryogenic system supplied 4.4 K supercritical helium to the magnet system, 50 K pressurized helium gas to high-temperature superconducting current lead, and 80 K pressurized helium gas to the thermal shield. Before cooldown, cryostat helium leak testing and helium gas purification were performed. It took approximately 41 days to cool the magnet system from room temperature to superconducting transition temperature. During operation, the refrigerator was stopped three times because of electrical grounding problems and incorrect control parameter values in the cold rotation machine control system. Except for problems, the cryogenic system was steadily operated. This paper describes the cryogenic system operation results during cooldown and magnet operation.