Loreto Bravo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Loreto Bravo has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
Jesús Hernández
Arrhythmias Unit, Cardiology Department, IBSAL-University Hospital, CIVER-CV, Universidad de Salamanca, Paseo de San Vicente, 58-182, 37007, Salamanca, Spain
5 shared publications- Javier Jiménez-Candil
Department of Cardiology, University Hospital, Paseo de San Vicente, 58-182, 37007 Salamanca, Spain
4 shared publications - Felipe Atienza
Cardiology Department, Hospital General Universitario Gregorio Marañón, Madrid, Spain
3 shared publications - Francisco Fernández-Avilés
Hospital General Universitario Gregorio Marañón
3 shared publications Olga Durán
Arrhythmias Unit, Cardiology Department, IBSAL-University Hospital, CIVER-CV, Universidad de Salamanca, Paseo de San Vicente, 58-182, 37007, Salamanca, Spain
3 shared publications- Pedro L. Sánchez
Department of Cardiology, University Hospital of Salamanca, 37007 Salamanca, Spain
3 shared publications
Latest Publications
- 1 February 2020
- Published by Elsevier in The American Journal of Cardiology
- Vol. 125 (3) , 409-414
Detecting Atrial Fibrillation in Patients With an Embolic Stroke of Undetermined Source (from the DAF-ESUS registry)
- 1 February 2020
- Published by Elsevier in The American Journal of Cardiology
- Vol. 125 (3) , 409-414
Detecting Atrial Fibrillation in Patients With an Embolic Stroke of Undetermined Source (from the DAF-ESUS registry)
- 27 November 2019
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 43 (1) , 62-67
A novel simple, fast, and safe approach for effective superior vena cava isolation using the third‐generation cryoballoon
Background: Superior vena cava (SVC) isolation with radiofrequency energy remains a challenge due to potential side effects, especially phrenic nerve (PN) or sinus node injury. The purpose of this study was to evaluate the feasibility of a novel SVC isolation technique using the third‐generation cryoballoon (CB3).Methods: Patients undergoing atrial fibrillation (AF) ablation were prospectively included. The procedure was performed with the CB3, beginning with the pulmonary veins and ending with SVC isolation. During applications in the SVC, continuous PN capture and sinus rate were monitored. Once reached SVC isolation during the application, 60 s more was applied, with no bonus application. If after 90 s the SVC was not isolated, application was stopped. A maximum number of four applications were permitted.Results: Thirty patients (62 ± 9 years; 74% male, 78% paroxysmal AF) were included. No SVC activity was observed in two patients. Success rate for SVC isolation was 89%. Mean number of applications per patient was 2.3 ± 1. Mean time to SVC isolation was 37 ± 20 s. Mean duration of application was 92 ± 15 s. Mean total time of procedure for SVC isolation was 218 ± 43 s. We recorded only two complications: one transient PN palsy and one short and transient sinus arrest. After a mean follow‐up of 5 ± 2 months, 89% are free from arrhythmia recurrence.Conclusions: We present a promising simple SVC‐isolation technique using CB3, featuring a high success rate and very low incidence of complications.
- 27 November 2019
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 43 (1) , 62-67
A novel simple, fast, and safe approach for effective superior vena cava isolation using the third‐generation cryoballoon
Background: Superior vena cava (SVC) isolation with radiofrequency energy remains a challenge due to potential side effects, especially phrenic nerve (PN) or sinus node injury. The purpose of this study was to evaluate the feasibility of a novel SVC isolation technique using the third‐generation cryoballoon (CB3).Methods: Patients undergoing atrial fibrillation (AF) ablation were prospectively included. The procedure was performed with the CB3, beginning with the pulmonary veins and ending with SVC isolation. During applications in the SVC, continuous PN capture and sinus rate were monitored. Once reached SVC isolation during the application, 60 s more was applied, with no bonus application. If after 90 s the SVC was not isolated, application was stopped. A maximum number of four applications were permitted.Results: Thirty patients (62 ± 9 years; 74% male, 78% paroxysmal AF) were included. No SVC activity was observed in two patients. Success rate for SVC isolation was 89%. Mean number of applications per patient was 2.3 ± 1. Mean time to SVC isolation was 37 ± 20 s. Mean duration of application was 92 ± 15 s. Mean total time of procedure for SVC isolation was 218 ± 43 s. We recorded only two complications: one transient PN palsy and one short and transient sinus arrest. After a mean follow‐up of 5 ± 2 months, 89% are free from arrhythmia recurrence.Conclusions: We present a promising simple SVC‐isolation technique using CB3, featuring a high success rate and very low incidence of complications.
- 16 September 2019
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 56 (3) , 349-357
Effectiveness of first versus successive antitachycardia pacing attempts: predictors and clinical consequences
Antitachycardia pacing (ATP) terminates the majority (but not all) of slow ventricular tachycardias (S-VT) with a cycle length (CL) > 320 ms. Usually, several ATP therapies are programmed in the S-VT zone. Our objective is to analyse the ATP effectiveness, comparing the first ATP attempt (ATP-1) to the second (ATP-2) and third (ATP-3) attempts.
- 16 September 2019
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 56 (3) , 349-357
Effectiveness of first versus successive antitachycardia pacing attempts: predictors and clinical consequences
Antitachycardia pacing (ATP) terminates the majority (but not all) of slow ventricular tachycardias (S-VT) with a cycle length (CL) > 320 ms. Usually, several ATP therapies are programmed in the S-VT zone. Our objective is to analyse the ATP effectiveness, comparing the first ATP attempt (ATP-1) to the second (ATP-2) and third (ATP-3) attempts.
- 20 March 2018
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 52 (1) , 69-76
Beta-blocker therapy is associated with a lower incidence of syncope due to fast ventricular tachycardias among implantable cardioverter-defibrillator patients with left ventricular dysfunction: results from a multicenter study
Among implantable cardioverter-defibrillator (ICD) patients, a substantial proportion of syncopes are due to fast ventricular tachycardias (FVTs). In the experimental models of ventricular tachycardias, the arterial vasoconstriction plays an important role in recovering the arterial pressure. Since beta-blockers increase vascular resistance, we hypothesized that beta-blockers could reduce the occurrence of syncope due to FVTs. Our objective was to determine the relationship between the beta-blocker therapy and the incidence of syncope in FVT (cycle length [CL] 250–320 ms) occurring in ICD patients. Slow VTs were excluded because of the lack of symptoms and VF episodes because of the small number.
- 20 March 2018
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 52 (1) , 69-76
Beta-blocker therapy is associated with a lower incidence of syncope due to fast ventricular tachycardias among implantable cardioverter-defibrillator patients with left ventricular dysfunction: results from a multicenter study
Among implantable cardioverter-defibrillator (ICD) patients, a substantial proportion of syncopes are due to fast ventricular tachycardias (FVTs). In the experimental models of ventricular tachycardias, the arterial vasoconstriction plays an important role in recovering the arterial pressure. Since beta-blockers increase vascular resistance, we hypothesized that beta-blockers could reduce the occurrence of syncope due to FVTs. Our objective was to determine the relationship between the beta-blocker therapy and the incidence of syncope in FVT (cycle length [CL] 250–320 ms) occurring in ICD patients. Slow VTs were excluded because of the lack of symptoms and VF episodes because of the small number.
- 2 January 2018
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (10) , 1638-1646
Delta of the local ventriculo-atrial intervals at the septal location to differentiate tachycardia using septal accessory pathways from atypical atrioventricular nodal re-entry
Tachycardia mediated by septal accessory pathways (AP) and atypical atrioventricular nodal re-entry (AVNRT) require careful electrophysiologic evaluation for differential diagnosis. We aim to describe the differential behaviour of local ventriculo-atrial (VA) intervals which predicts the tachycardia mechanism. The local VA intervals at the para-Hisian septum were measured under three different situations: (i) tachycardia; (ii) sustained entrainment from the right ventricular apex (RVA); and (iii) continuous pacing from the RVA during sinus rhythm. Differences were computed as follows: Δ-VAentr = VA during entrainment − VA during tachycardia; and Δ-VApac = VA while pacing during sinus rhythm − VA during tachycardia. In contrast to AVNRT, we hypothesized that an invariable retrograde conduction through the septal AP will keep the result of the subtractions close to 0 ms in cases of ortodromic atrioventricular re-entrant tachycardia (AVRT). We analysed 55 atypical AVNRT (45% posterior type) and 82 AVRT (10 anteroseptal, 18 para-Hisian, 12 mid-septal, and 42 posteroseptal). Δ-VAentr was longer for AVNRT (98.5 ± 40.3 ms) compared with septal AP (−5.7 ± 19.3 ms; P < 0.001). A value of 50 ms showed 98.7% sensitivity and 92% specificity (AUC 0.99; 95% CI 0.98–1). According to physiological criteria, a negative Δ-VAentr remains unobserved in the case of AVNRT (positive predictive value 100% for septal AP). Δ-VApac was also longer for AVNRT (66.5 ± 14.6 ms) compared with septal AP (−9.7 ± 3.3 ms; P < 0.001). A value of 50 ms showed 100% sensitivity and 74% specificity (AUC 0.86; 95% CI 0.76–0.93). Delta of the local VA intervals enables distinction between atypical AVNRT and AVRT mediated by septal AP.
- 2 January 2018
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (10) , 1638-1646
Delta of the local ventriculo-atrial intervals at the septal location to differentiate tachycardia using septal accessory pathways from atypical atrioventricular nodal re-entry
Tachycardia mediated by septal accessory pathways (AP) and atypical atrioventricular nodal re-entry (AVNRT) require careful electrophysiologic evaluation for differential diagnosis. We aim to describe the differential behaviour of local ventriculo-atrial (VA) intervals which predicts the tachycardia mechanism. The local VA intervals at the para-Hisian septum were measured under three different situations: (i) tachycardia; (ii) sustained entrainment from the right ventricular apex (RVA); and (iii) continuous pacing from the RVA during sinus rhythm. Differences were computed as follows: Δ-VAentr = VA during entrainment − VA during tachycardia; and Δ-VApac = VA while pacing during sinus rhythm − VA during tachycardia. In contrast to AVNRT, we hypothesized that an invariable retrograde conduction through the septal AP will keep the result of the subtractions close to 0 ms in cases of ortodromic atrioventricular re-entrant tachycardia (AVRT). We analysed 55 atypical AVNRT (45% posterior type) and 82 AVRT (10 anteroseptal, 18 para-Hisian, 12 mid-septal, and 42 posteroseptal). Δ-VAentr was longer for AVNRT (98.5 ± 40.3 ms) compared with septal AP (−5.7 ± 19.3 ms; P < 0.001). A value of 50 ms showed 98.7% sensitivity and 92% specificity (AUC 0.99; 95% CI 0.98–1). According to physiological criteria, a negative Δ-VAentr remains unobserved in the case of AVNRT (positive predictive value 100% for septal AP). Δ-VApac was also longer for AVNRT (66.5 ± 14.6 ms) compared with septal AP (−9.7 ± 3.3 ms; P < 0.001). A value of 50 ms showed 100% sensitivity and 74% specificity (AUC 0.86; 95% CI 0.76–0.93). Delta of the local VA intervals enables distinction between atypical AVNRT and AVRT mediated by septal AP.
- Open Access
- 3 October 2017
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (8) , 1334-1342
Safety and efficacy of cryoablation vs. radiofrequency ablation of septal accessory pathways: systematic review of the literature and meta-analyses
Radiofrequency ablation (RFA) of septal accessory pathways (APs) is associated with a significant rate of first procedure failures and complications. Cryoablation is an alternative energy source but there are no studies comparing both ablation techniques. We aimed to systematically review the literature and compare the efficacy and safety of cryoablation vs. RFA of septal APs. We conducted two separate meta-analysis of cryoablation and RFA of septal APs and calculated the global estimates of the efficacy and safety. Sixty-four articles were included: 38 articles reporting RFA and 27 articles reporting cryoablation procedures. Additionally, we included the previously non-published cryoablation registry of septal APs performed at our institution. Overall, 4244 septal APs constitute our study population, 3495 in the RFA cohort and 749 in the cryoablation cohort. Acute procedural success rate of cryoablation was 86.0% (95% CI 81.6–89.4%) and RFA 89.0% (95% CI 86.8–91.0%). Recurrence rate of cryoablation was 18.1% (95% CI 14.8–21.8%) and RFA 9.9% (95% CI 8.2–12.0%). Long-term success rate after multiple ablation procedures of cryoablation was 75.9% (95% CI 68.2–82.3%) and RFA 88.4% (95% CI 84.7–91.3%). There were no reported cases of persistent atrioventricular block (AVB) with cryoablation and 2.7% (95% CI 2.2–3.4%) with RFA. Studies of RFA for treatment of septal APs report higher efficacy rates than do studies using cryoablation, but a significantly higher rate of AVB.
- 3 October 2017
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (8) , 1334-1342
Open AccessSafety and efficacy of cryoablation vs. radiofrequency ablation of septal accessory pathways: systematic review of the literature and meta-analyses
Radiofrequency ablation (RFA) of septal accessory pathways (APs) is associated with a significant rate of first procedure failures and complications. Cryoablation is an alternative energy source but there are no studies comparing both ablation techniques. We aimed to systematically review the literature and compare the efficacy and safety of cryoablation vs. RFA of septal APs. We conducted two separate meta-analysis of cryoablation and RFA of septal APs and calculated the global estimates of the efficacy and safety. Sixty-four articles were included: 38 articles reporting RFA and 27 articles reporting cryoablation procedures. Additionally, we included the previously non-published cryoablation registry of septal APs performed at our institution. Overall, 4244 septal APs constitute our study population, 3495 in the RFA cohort and 749 in the cryoablation cohort. Acute procedural success rate of cryoablation was 86.0% (95% CI 81.6–89.4%) and RFA 89.0% (95% CI 86.8–91.0%). Recurrence rate of cryoablation was 18.1% (95% CI 14.8–21.8%) and RFA 9.9% (95% CI 8.2–12.0%). Long-term success rate after multiple ablation procedures of cryoablation was 75.9% (95% CI 68.2–82.3%) and RFA 88.4% (95% CI 84.7–91.3%). There were no reported cases of persistent atrioventricular block (AVB) with cryoablation and 2.7% (95% CI 2.2–3.4%) with RFA. Studies of RFA for treatment of septal APs report higher efficacy rates than do studies using cryoablation, but a significantly higher rate of AVB.
- 7 September 2017
- Published by Oxford University Press (OUP) in European Heart Journal: Acute Cardiovascular Care
- Vol. 7 (5) , 484-489
Percutaneous extracorporeal membrane oxygenation in electrical storm: five case reports addressing efficacy, transferring allowance or radiofrequency ablation support
Extracorporeal membrane oxygenation systems have undergone rapid technological improvements and are now feasible options for medium-term support of severe cardiac or pulmonary failure. We report five cases of electrical storm that was rescued by the insertion of peripheral veno-arterial extracorporeal membrane oxygenation systems. This device could help to restore systemic circulation as well as permitting organ perfusion in patients with cardiogenic shock in relation to electrical storm thus achieving greater electrical stability. Also, in some cases extracorporeal membrane oxygenation support could facilitate electrophysiology study.
- 7 September 2017
- Published by Oxford University Press (OUP) in European Heart Journal: Acute Cardiovascular Care
- Vol. 7 (5) , 484-489
Percutaneous extracorporeal membrane oxygenation in electrical storm: five case reports addressing efficacy, transferring allowance or radiofrequency ablation support
Extracorporeal membrane oxygenation systems have undergone rapid technological improvements and are now feasible options for medium-term support of severe cardiac or pulmonary failure. We report five cases of electrical storm that was rescued by the insertion of peripheral veno-arterial extracorporeal membrane oxygenation systems. This device could help to restore systemic circulation as well as permitting organ perfusion in patients with cardiogenic shock in relation to electrical storm thus achieving greater electrical stability. Also, in some cases extracorporeal membrane oxygenation support could facilitate electrophysiology study.
- 26 August 2015
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 44 (2) , 187-195
Differences in ventricular tachyarrythmias and antitachycardia pacing effectiveness according to the ICD indication (primary versus secondary prevention): an analysis based on the stored electrograms
To determine whether monomorphic ventricular tachycardias (VTs) have different characteristics and/or responses to antitachycardia pacing (ATP) with respect to the indication—primary prevention (PP) versus secondary prevention (SP)—among ICD patients with left ventricular dysfunction. We prospectively studied 551 VT (cycle length [CL] 329 ± 35 ms; PP 34 %) occurring in 67 ICD patients with left ventricular dysfunction (LVEF 35 ± 8 %). ICD programming was standardized, including ATP for slow (CL 400–321 ms) and fast VT (CL 250–320 ms). We analyzed the following aspects: CL, percentage of variability of the 12 RR intervals prior to ATP (P-RR)—which was calculated by dividing the mean difference between each R-R interval with the next one by the CL × 100—and type of termination: immediate (VT ceased immediately upon ATP completion) or delayed (VT persisted after ATP). ATP was successful in 86 % of VTs. VTs occurring in SP patients had a lower P-RR, median (IQR) 2.7 % (1.2–3.7) versus 1.9 % (0.9–3.2); p = 0.002; they terminated immediately after ATP less frequently (27 % versus 12 %; p < 0.001), and although they were more frequently slow (51 % versus 67 %; p = 0.01), ATP was less effective in them, 92 versus 80 % (p = 0.02). VTs occurring in SP patients are slower, more stable, and they terminate less frequently at ATP. Therefore, compared with PP, SP patients seem to have fewer self-terminating VTs.
- 26 August 2015
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 44 (2) , 187-195
Differences in ventricular tachyarrythmias and antitachycardia pacing effectiveness according to the ICD indication (primary versus secondary prevention): an analysis based on the stored electrograms
To determine whether monomorphic ventricular tachycardias (VTs) have different characteristics and/or responses to antitachycardia pacing (ATP) with respect to the indication—primary prevention (PP) versus secondary prevention (SP)—among ICD patients with left ventricular dysfunction. We prospectively studied 551 VT (cycle length [CL] 329 ± 35 ms; PP 34 %) occurring in 67 ICD patients with left ventricular dysfunction (LVEF 35 ± 8 %). ICD programming was standardized, including ATP for slow (CL 400–321 ms) and fast VT (CL 250–320 ms). We analyzed the following aspects: CL, percentage of variability of the 12 RR intervals prior to ATP (P-RR)—which was calculated by dividing the mean difference between each R-R interval with the next one by the CL × 100—and type of termination: immediate (VT ceased immediately upon ATP completion) or delayed (VT persisted after ATP). ATP was successful in 86 % of VTs. VTs occurring in SP patients had a lower P-RR, median (IQR) 2.7 % (1.2–3.7) versus 1.9 % (0.9–3.2); p = 0.002; they terminated immediately after ATP less frequently (27 % versus 12 %; p < 0.001), and although they were more frequently slow (51 % versus 67 %; p = 0.01), ATP was less effective in them, 92 versus 80 % (p = 0.02). VTs occurring in SP patients are slower, more stable, and they terminate less frequently at ATP. Therefore, compared with PP, SP patients seem to have fewer self-terminating VTs.
- 1 March 2014
- Published by Elsevier in The American Journal of Cardiology
- Vol. 113 (5) , 827-831
Comparison of the Safety and Feasibility of Arrhythmia Ablation Using the Amigo Robotic Remote Catheter System Versus Manual Ablation
- 1 March 2014
- Published by Elsevier in The American Journal of Cardiology
- Vol. 113 (5) , 827-831
Comparison of the Safety and Feasibility of Arrhythmia Ablation Using the Amigo Robotic Remote Catheter System Versus Manual Ablation