Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Cederick Landry has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Dual-Output Physiology-Informed Neural Network Architecture for Continuous Cuffless Blood Pressure Waveform Estimation: A Proof‑of‑Concept

    by Zaineb Aloui, Cederick Landry

    This pilot study introduces the first subject‑specific, physiology‑informed neural network approach for accurate estimation of the full blood pressure (BP) waveform. The method builds on a nonlinear autoregressive model with exogenous inputs (NARX), implemented through artificial neural networks trained on subject‑specific electrocardiography (ECG) and photoplethysmography (PPG) signals. Three model configurations are evaluated: (1) a reference NARX model trained on 30 min of data, (2) a reduced‑data NARX model trained on 15 min, and (3) a physiology‑informed model (NARX physio ), also trained on 15 min, which incorporates a personalized four‑parameter BP–PPG sigmoidal layer into the training process through a dual‑output loss function that simultaneously estimates the BP and PPG waveforms. By embedding BP–PPG physiology directly into training, the architecture ensures internal physiological consistency—something not achieved in existing PPG‑based or purely data‑driven machine learning approaches. All three models were assessed on a small ( n = 5), but rich dataset, covering over six hours of activities of daily living. Despite using only half the training duration of the baseline NARX model, the physiology‑informed approach maintains accurate BP estimation. Beyond improved accuracy, the sigmoidal layer provides physiologically interpretable parameters, including estimated arterial‑compliance curve width with an average of 36.5 mmHg and an estimated PPG contact pressure with an average of 59 mmHg in this study, offering insights unavailable in standard neural network models. Together, these preliminary results suggest that the NARX physio model enables effective personalization of cuffless BP waveform estimation with limited training data, highlighting its potential to improve both the reliability and the clinical relevance of continuous cuffless BP monitoring.

  • Smartphone-Based Blood Pressure Monitoring via the Oscillometric Finger Pressing Method: Investigation of the DC Component of PPG

    by Mark Freithaler, Hadi Daher, Cederick Landry, Vishaal Dhamotharan, Shipeng Wang, Anand Chandrasekhar, Sanjeev G. Shroff, Ramakrishna Mukkamala

    Objective: Oscillometric finger pressing is a potential method for smartphone-based blood pressure (BP) monitoring. A photoplethysmography (PPG)-force sensor unit measures the slowly increasing finger pressure applied by the user under visual guidance and the resulting variable blood volume oscillations (“AC PPG”). BP can then be estimated from the oscillation height versus finger pressure function. The non-oscillating component of PPG (“DC PPG”) during oscillometric finger pressing was investigated. Methods: The total (AC+DC) PPG waveform, finger pressure, and ECG waveform during finger pressing were measured with a modified custom system along with arm cuff BP in volunteers. A mathematical model accounting for the arterial compliance curve and tissue compression was developed to explain the measured total PPG waveform versus finger pressure function. The model predicted that DC PPG (average of the total PPG over each heartbeat) versus finger pressure function will show a fiducial marker (bend) near finger systolic BP (SP). An algorithm was developed to detect this bend and estimate arm SP from the finger pressing measurements. Results: The model explained the measured total PPG waveform versus finger pressure function over the finger pressure range that is relevant to BP estimation. The model-based algorithm yielded a correlation coefficient of 0.90 and a precision error of 9.2 mmHg against cuff SP (N = 18). Conclusion: An easy-to-understand model can explain the total PPG waveform during finger pressing, and SP can be estimated from the DC (non-oscillating) PPG versus finger pressure function. Significance: These findings may prove useful in converting ubiquitous smartphones into BP sensors.

  • No Cuff, No Trust

    by Cederick Landry, Gregory L. Hundemer, Rémi Goupil


  • Employing Deep Reinforcement Learning to Maximize Lower Limb Blood Flow Using Intermittent Pneumatic Compression

    by Iara B. Santelices, Cederick LandryMember, Arash AramiMember, Sean D. Peterson

    Intermittent pneumatic compression (IPC) systems apply external pressure to the lower limbs and enhance peripheral blood flow. We previously introduced a cardiac-gated compression system that enhanced arterial blood velocity (BV) in the lower limb compared to fixed compression timing (CT) for seated and standing sub7 jects. However, these pilot studies found that the CT that maximized BV was not constant across individuals and could change over time. Current CT modelling methods for IPC are limited to predictions for a single day and one heartbeat ahead. However, IPC therapy for may span weeks or longer, the BV response to compression can vary with physiological state, and the best CT for eliciting the desired physiological outcome may change, even for the same individual. We propose that a deep reinforcement learning (DRL) algorithm can learn and adaptively modify CT to achieve a selected outcome using IPC. Herein, we target maximizing lower limb arterial BV as the desired out19 come and build participant-specific simulated lower limb environments for 6 participants. We show that DRL can adaptively learn the CT for IPC that maximized arterial BV. Compared to previous work, the DRL agent achieves 98% ± 2 of the resultant blood flow and is faster at maximizing BV; the DRL agent can learn an “optimal” policy in 15 minutes ± 2 on average and can adapt on the fly. Given a desired objective, we posit that the proposed DRL agent can be implemented in IPC systems to rapidly learn the (potentially time-varying) “optimal” CT with a human-in-the-loop.


  • Nonlinear Viscoelastic Modeling of Finger Arteries: Toward Smartphone-Based Blood Pressure Monitoring via the Oscillometric Finger Pressing Method

    by Cederick Landry, Mark Freithaler, Vishaal Dhamotharan, Hadi Daher, Sanjeev G. Shroff, Ramakrishna Mukkamala

    Objective: Oscillometric finger pressing is a smartphone-based blood pressure (BP) monitoring method. Finger photoplethysmography (PPG) oscillations and pressure are measured during a steady increase in finger pressure, and an algorithm computes systolic BP (SP) and diastolic BP (DP) from the measurements. The objective was to assess the impact of finger artery viscoelasticity on the BP computation. Methods: Nonlinear viscoelastic models relating transmural pressure (finger BP – applied pressure) to PPG oscillations during finger pressing were developed. The output of each model to a measured transmural pressure input was fitted to measured PPG oscillations from 15 participants. A parametric sensitivity analysis was performed via model simulations to elucidate the viscoelastic effect on the derivative-based BP computation algorithm. Results: A Wiener viscoelastic model comprising a first-order transfer function followed by a static sigmoidal function fitted the measured PPG oscillations better than an elastic model containing only the static function (median (IQR) error of 30.5% (25.6%–34.0%) vs 50.9% (46.7%–53.7%); p<0.01). In Wiener model simulations, the derivative algorithm underestimated SP, especially with high pulse pressure and low transfer function cutoff frequency (i.e., greater viscoelasticity). The mean of the normalized PPG waveform at the maximum oscillation beat was found to correlate with the cutoff frequency ( r = −0.8) and could thus possibly be used to compensate for viscoelasticity. Conclusion: Finger artery viscoelasticity negatively impacts oscillometric BP computation algorithms but can potentially be compensated for using available measurements. Significance: These findings may help in converting smartphones into truly cuffless BP monitors for improving hypertension awareness and control.


  • Cuffless Blood Pressure Estimation During Moderate- and Heavy-Intensity Exercise Using Wearable ECG and PPG

    by Cederick Landry, Eric T. Hedge, Richard L. Hughson, Sean D. Peterson, Arash Arami

    Objective: To develop and evaluate an accurate method for cuffless blood pressure (BP) estimation during moderate- and heavy-intensity exercise. Methods: Twelve participants performed three cycling exercises: a ramp-incremental exercise to exhaustion, and moderate and heavy pseudorandom binary sequence exercises on an electronically braked cycle ergometer over the course of 21 minutes. Subject-specific and population-based nonlinear autoregressive models with exogenous inputs (NARX) were compared with feedforward artificial neural network (ANN) models and pulse arrival time (PAT) models. Results: Population-based NARX models, that is, trained on the three cycling exercise conditions for 11 participants and tested on the remaining participant (applying leave-one-subject-out cross-validation), performed better than the other models and showed good capability for estimating large changes in mean arterial pressure (MAP). The models were unable to track consistent decreases in BP during prolonged exercise caused by reduction in peripheral vascular resistance, since this information is apparently not encoded in the employed proxy physiological signals (electrocardiography and forehead PPG) used for BP estimation. Nevertheless, the population-based NARX model had an error standard deviation of 11.0 mmHg during the entire exercise window, which improved to 9.0 mmHg when the model was periodically calibrated every 7 minutes. Conclusion: Population-based NARX models can estimate BP during moderate- and heavy-intensity exercise but need periodic calibration to account for the change in vascular resistance during exertion. Significance: MAP can be continuously tracked during exercise using only wearable sensors, making monitoring exercise physiology more convenient and accessible.


  • Open Access

    Isolating In-Situ Grip and Push Force Distribution from Hand-Handle Contact Pressure with an Industrial Electric Nutrunner

    by Cederick Landry, Daniel Loewen, Harish Rao, Brendan L. Pinto, Robert Bahensky, Naveen Chandrashekar

    Objectives: Grip force during hand tool operation is the primary contributor to tendon strain and related wrist injuries, whereas push force is a contributor to shoulder injuries. However, both cannot be directly measured using a single measurement instrument. The objective of this research was to develop and test an algorithm to isolate the grip and push force distributions from in-situ hand-handle pressure measurements and to quantify their distributions among industrial workers using an electric nutrunner. Methods: Experienced automobile assembly line workers used an industrial nutrunner to tighten fasteners at various locations and postures. The pressure applied by the hand on the tool handle was measured dynamically using pressure sensors mounted on the handle. An algorithm was developed to compute the push force applied to the handle of an electric pistol-grip nutrunner based on recorded pressure measurements. An optimization problem was solved to find the contribution of each measured pressure to the actual pushing force of the tool. Finally, the grip force was determined from the difference between the measured pressure and the calculated pushing pressure. Results: The grip force and push force were successfully isolated and there was no correlation between the two forces. The computed grip force increased from low to high fastener locations, whereas the push force significantly increased during overhead fastening. A significant difference across the participants’ computed grip forces was observed. The grip force distribution showed that its contribution to total hand force was larger than other definitions in the literature. Conclusions: The developed algorithm can aid in better understanding the risk of injury associated with different tasks through the notion of grip and push force distribution. This was shown to be important as even workers with considerable power tool experience applied significantly more grip and push force than other participants, all of whom successfully completed each task. Moreover, the fact that both forces were uncorrelated shows the need for extracting them independently.


  • Accurate Blood Pressure Estimation During Activities of Daily Living: A Wearable Cuffless Solution

    by Cederick Landry, Eric T. Hedge, Richard L. Hughson, Sean D. Peterson, Arash Arami

    The objective is to develop a cuffless method that accurately estimates blood pressure (BP) during activities of daily living. User-specific nonlinear autoregressive models with exogenous inputs (NARX) are implemented using artificial neural networks to estimate the BP waveforms from electrocardiography and photoplethysmography signals. To broaden the range of BP in the training data, subjects followed a short procedure consisting of sitting, standing, walking, Valsalva maneuvers, and static handgrip exercises. The procedure was performed before and after a six-hour testing phase wherein five participants went about their normal daily living activities. Data were further collected at a four-month time point for two participants and again at six months for one of the two. The performance of three different NARX models was compared with three pulse arrival time (PAT) models. The NARX models demonstrate superior accuracy and correlation with “ground truth” systolic and diastolic BP measures compared to the PAT models and a clear advantage in estimating the large range of BP. Preliminary results show that the NARX models can accurately estimate BP even months apart from the training. Preliminary testing suggests that it is robust against variabilities due to sensor placement. This establishes a method for cuffless BP estimation during activities of daily living that can be used for continuous monitoring and acute hypotension and hypertension detection.


  • Design Space Exploration of a Beam Flexible Hub Concept for an Inside-Out Ceramic Turbine Using a Simplified Rotordynamic Finite Element Model

    by Céderick Landry, Patrick K. Dubois, Jean-Sébastien Plante, Francois R. Charron, Mathieu Picard

    This paper presents a new flexible hub design for the inside-out ceramic turbine (ICT) rotor configuration. This configuration is used in microturbines to integrate ceramic blades in order to increase turbine inlet temperature (TIT), which leads to higher cycle efficiency values. The ICT uses an outer composite rim to load the ceramic blades in compression by converting the centrifugal loads of the blades into hoop stresses in the composite rim. High stresses in the composite rim lead to high radial displacement of the blades. This displacement is compensated by using flexible hub in order to maintain the contact with the blades. However, hub flexibility can lead to rotordynamic problems as heavy hub deformation will induce high stresses in it. Thus, stresses in the hub are induced by both rotordynamics and centrifugation, requiring a multi-objective design process, which has yielded geometries that limited, until now, the blade tip speed to 358 m/s. In this paper, a simplified rotordynamics finite element model of a flexible hub is developed to allow quick design iterations. Using the model, a design space exploration of this hub concept is done while considering centrifugation and rotordynamics. Experimental validation is conducted on a simplified ICT prototype up to 129 krpm, i.e., an equivalent blade tip speed of 390 m/s. Finally, predictions from the experimentally calibrated model show that the tested prototype hub could reach a blade tip speed of 680 m/s.

  • Accuracy enhancement in low frequency gain and phase detector (AD8302) based bioimpedance spectroscopy system

    by Youssoufa Mohamadou, Foutse Momo, Lealea Theophile, C. Njike Kouekeu Landry, Tueche Fabrice, Simeu Emmanuel