Zhicheng Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Zhicheng Guo has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Alex Q. Huang
University of Texas at Austin
9 shared publications - Binhong Cao
Department of Electrical Engineering, Arizona State University, Tempe, AZ, USA
4 shared publications - Xianyong Feng
Center for Electromechanics, University of Texas System, 7067 Austin, Texas United States 78701-2982
3 shared publications - Chen Chen
Semiconductor Power Electronics Center University of Texas at Austin 78712 Austin TX USA
2 shared publications - Guangyu Yan
Power Electronics and Energy Conversion (PEEC) Lab, Arizona State University, Tempe, AZ, USA
2 shared publications - Jie Deng
Power Electronics and Energy Conversion (PEEC) Lab, Arizona State University, Tempe, AZ, USA
2 shared publications
Latest Publications
- Open Access
- 3 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 7, 1846-1864
A Review of DC-DC Converters for Modular Solid-State Transformers: Challenges, Comparative Analysis, and Design
Solid-State Transformer (SST) technology has advanced significantly in recent decades, driven by the development of wide-bandgap semiconductors, progress in magnetic component design, and continuous optimization of power converter topologies. The modular SST architecture employs multiple power electronic building blocks (PEBBs) that constitute the DC-DC stage. Selecting the most suitable PEBB topology is critical to the overall performance of the SST and remains an open research question. This paper presents a comprehensive overview of the main requirements and challenges associated with the PEBB and reviews the most suitable DC-DC converter topologies for modular SST applications, including a comparative analysis of efficiencies reported in the literature in recent years. The most promising topologies are then identified, and a case study with a detailed design methodology is presented. A review of the latest advancements in medium-frequency transformer technology, which represents a key bottleneck in DC–DC converter design, is also included. Finally, experimental validations considering three different PEBB topologies are performed, achieving high efficiency (98.55% peak), confirming its feasibility for modular SST systems.
- 3 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 7, 1846-1864
Open AccessA Review of DC-DC Converters for Modular Solid-State Transformers: Challenges, Comparative Analysis, and Design
Solid-State Transformer (SST) technology has advanced significantly in recent decades, driven by the development of wide-bandgap semiconductors, progress in magnetic component design, and continuous optimization of power converter topologies. The modular SST architecture employs multiple power electronic building blocks (PEBBs) that constitute the DC-DC stage. Selecting the most suitable PEBB topology is critical to the overall performance of the SST and remains an open research question. This paper presents a comprehensive overview of the main requirements and challenges associated with the PEBB and reviews the most suitable DC-DC converter topologies for modular SST applications, including a comparative analysis of efficiencies reported in the literature in recent years. The most promising topologies are then identified, and a case study with a detailed design methodology is presented. A review of the latest advancements in medium-frequency transformer technology, which represents a key bottleneck in DC–DC converter design, is also included. Finally, experimental validations considering three different PEBB topologies are performed, achieving high efficiency (98.55% peak), confirming its feasibility for modular SST systems.
- 16 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (6) , 9422-9436
A Review of High-Power Medium-Frequency Transformers in Medium-Voltage Power Electronics: State of the Art, Challenges, and Solutions
Medium-frequency transformers (MFTs) have emerged as a key enabling technology in medium-voltage (MV) power electronics systems, supporting applications such as solid-state transformers, power electronic traction transformers, and medium-voltage direct current power distribution. This review provides a comprehensive overview of high-power MFTs, focusing on their state of the art, applications, technical challenges, and current research solutions. This article surveys key considerations, including core materials, core shapes, winding technologies, winding structures, insulation considerations, dielectric materials, electric field stress grading materials, and cooling technologies. Specifically targeted at modern MV power electronics, this article discusses the challenges and solutions in MFT insulation design and test. The topics include complex voltage stress and electric field distribution, partial discharge under medium-frequency high dv/dt waveforms, and insulation test standards, which are critical to enhance the performance, reliability, and development of high-power MFTs in MV applications.
- 16 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (6) , 9422-9436
A Review of High-Power Medium-Frequency Transformers in Medium-Voltage Power Electronics: State of the Art, Challenges, and Solutions
Medium-frequency transformers (MFTs) have emerged as a key enabling technology in medium-voltage (MV) power electronics systems, supporting applications such as solid-state transformers, power electronic traction transformers, and medium-voltage direct current power distribution. This review provides a comprehensive overview of high-power MFTs, focusing on their state of the art, applications, technical challenges, and current research solutions. This article surveys key considerations, including core materials, core shapes, winding technologies, winding structures, insulation considerations, dielectric materials, electric field stress grading materials, and cooling technologies. Specifically targeted at modern MV power electronics, this article discusses the challenges and solutions in MFT insulation design and test. The topics include complex voltage stress and electric field distribution, partial discharge under medium-frequency high dv/dt waveforms, and insulation test standards, which are critical to enhance the performance, reliability, and development of high-power MFTs in MV applications.
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (4) , 4546-4550
An Integrated Inductive Power and Capacitive Data Transfer System Using Ultrathin Nanocrystalline Laminated Sheets
This letter proposes a novel system that exploits 0.9 mm-thick nanocrystalline (NC) laminated sheets to integrate inductive power transfer (IPT) with capacitive data transfer. Besides enhancing inductive coupling and providing magnetic shielding, the NC laminated sheets can also enable capacitive coupling for data transfer through the parasitic capacitances, benefiting from the high electrical conductivity of NC material. Compared to those similar solutions, the NC laminated sheets combine the functions of ferrite plates and metal plates, enabling a more compact system. A 100-W prototype is established with 97.2% power transfer efficiency and 1-Mbps data rate. The operation of data transfer has almost no impact on power efficiency, and the interference from the power channel to data channel is sufficiently low, which guarantees the correct recovery of data bits.
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (4) , 4546-4550
An Integrated Inductive Power and Capacitive Data Transfer System Using Ultrathin Nanocrystalline Laminated Sheets
This letter proposes a novel system that exploits 0.9 mm-thick nanocrystalline (NC) laminated sheets to integrate inductive power transfer (IPT) with capacitive data transfer. Besides enhancing inductive coupling and providing magnetic shielding, the NC laminated sheets can also enable capacitive coupling for data transfer through the parasitic capacitances, benefiting from the high electrical conductivity of NC material. Compared to those similar solutions, the NC laminated sheets combine the functions of ferrite plates and metal plates, enabling a more compact system. A 100-W prototype is established with 97.2% power transfer efficiency and 1-Mbps data rate. The operation of data transfer has almost no impact on power efficiency, and the interference from the power channel to data channel is sufficiently low, which guarantees the correct recovery of data bits.
- 12 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (4) , 4530-4535
A Novel Hybrid Magnetic Core Structure for Planar Medium-Frequency Transformer
This letter proposes a novel planar hybrid magnetic core structure to address the significant eddy current loss issue of nanocrystalline (NC) laminated core in medium-frequency and high-frequency transformers. The proposed approach mitigates eddy current losses caused by flux components perpendicular to the NC cores by introducing ferrite cores that redirect these flux components. The hybrid core structure was validated with a planar transformer with rectangular coils subjected to pulse width modulation (PWM)-wave excitation from 200 V–600 V and 20–200 kHz. Compared with the NC-only design, the hybrid core structure demonstrates a 26.7% loss reduction under 600 V/20 kHz excitation, along with improved uniformity in flux density and temperature distribution. This approach is also validated over a wide frequency range (20–200 kHz) at a fixed voltage amplitude of 200 V, where the loss reduction increases with frequency, reaching 47.8% at 200 kHz. Moreover, the proposed hybrid structure also demonstrated its effectiveness in a planar transformer with Double-D (DD) coils at 200 V, achieving more than 50% core-loss reduction in the 50–200 kHz range compared with the NC-only design.
- 12 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (4) , 4530-4535
A Novel Hybrid Magnetic Core Structure for Planar Medium-Frequency Transformer
This letter proposes a novel planar hybrid magnetic core structure to address the significant eddy current loss issue of nanocrystalline (NC) laminated core in medium-frequency and high-frequency transformers. The proposed approach mitigates eddy current losses caused by flux components perpendicular to the NC cores by introducing ferrite cores that redirect these flux components. The hybrid core structure was validated with a planar transformer with rectangular coils subjected to pulse width modulation (PWM)-wave excitation from 200 V–600 V and 20–200 kHz. Compared with the NC-only design, the hybrid core structure demonstrates a 26.7% loss reduction under 600 V/20 kHz excitation, along with improved uniformity in flux density and temperature distribution. This approach is also validated over a wide frequency range (20–200 kHz) at a fixed voltage amplitude of 200 V, where the loss reduction increases with frequency, reaching 47.8% at 200 kHz. Moreover, the proposed hybrid structure also demonstrated its effectiveness in a planar transformer with Double-D (DD) coils at 200 V, achieving more than 50% core-loss reduction in the 50–200 kHz range compared with the NC-only design.
- Open Access
- 3 October 2024
- Published by MDPI AG in Electronics
- Vol. 13 (19) , 3918
Hardware Testing Methodologies for Wide Bandgap High-Power Converters
Wide bandgap (WBG) power semiconductor devices are increasingly replacing silicon IGBTs in high-power and high-voltage power electronics applications. However, there is a significant gap in the literature regarding efficient testing methodologies for high-power and high-voltage converters under constrained laboratory resources. This paper addresses this gap by presenting comprehensive, hardware-focused testing methodologies for high-power and high-voltage WBG power semiconductor-based converter bring-up before the control validation phase steps in. The proposed methods enable thorough evaluation and validation of converter hardware, including device switching characteristics, driving circuit functionality, thermal management performance, insulation integrity, and sustained operation at full power. We utilized the double pulse test (DPT) to characterize switching performance in a two-level phase leg configuration, extract circuit parasitics, and validate magnetic components. The DPT was further applied to optimize gate driving circuits, validate overcurrent protection mechanisms, and measure device on-resistance. Additionally, a multicycle test was introduced to rapidly assess steady-state converter performance and estimate efficiency. Recognizing the critical role of thermal management in high-power converters, our methodologies extend to the experimental extraction of key thermal parameters—such as junction-to-ambient thermal resistance and thermal capacitance—via a heat loss injection method. A correlation method between temperature sensor measurements and junction temperature is presented to enhance the accuracy of device temperature monitoring during tests. To ensure reliability and safety, dielectric withstand tests and partial discharge measurements were conducted at both component and converter levels under conventional 60 Hz sinusoidal and high-frequency PWM waveforms. Finally, we highlight the importance of testing converters under full voltage, current, and thermal conditions through power circulating tests with minimal power consumption, applicable to both non-isolated and isolated high-power converters. Practical examples are provided to demonstrate the effectiveness and applicability of these hardware testing methodologies.
- 3 October 2024
- Published by MDPI AG in Electronics
- Vol. 13 (19) , 3918
Open AccessHardware Testing Methodologies for Wide Bandgap High-Power Converters
Wide bandgap (WBG) power semiconductor devices are increasingly replacing silicon IGBTs in high-power and high-voltage power electronics applications. However, there is a significant gap in the literature regarding efficient testing methodologies for high-power and high-voltage converters under constrained laboratory resources. This paper addresses this gap by presenting comprehensive, hardware-focused testing methodologies for high-power and high-voltage WBG power semiconductor-based converter bring-up before the control validation phase steps in. The proposed methods enable thorough evaluation and validation of converter hardware, including device switching characteristics, driving circuit functionality, thermal management performance, insulation integrity, and sustained operation at full power. We utilized the double pulse test (DPT) to characterize switching performance in a two-level phase leg configuration, extract circuit parasitics, and validate magnetic components. The DPT was further applied to optimize gate driving circuits, validate overcurrent protection mechanisms, and measure device on-resistance. Additionally, a multicycle test was introduced to rapidly assess steady-state converter performance and estimate efficiency. Recognizing the critical role of thermal management in high-power converters, our methodologies extend to the experimental extraction of key thermal parameters—such as junction-to-ambient thermal resistance and thermal capacitance—via a heat loss injection method. A correlation method between temperature sensor measurements and junction temperature is presented to enhance the accuracy of device temperature monitoring during tests. To ensure reliability and safety, dielectric withstand tests and partial discharge measurements were conducted at both component and converter levels under conventional 60 Hz sinusoidal and high-frequency PWM waveforms. Finally, we highlight the importance of testing converters under full voltage, current, and thermal conditions through power circulating tests with minimal power consumption, applicable to both non-isolated and isolated high-power converters. Practical examples are provided to demonstrate the effectiveness and applicability of these hardware testing methodologies.
- Open Access
- 9 September 2024
- Published by MDPI AG in Preprints.org
Hardware Testing Methodology for Wide Bandgap High Power Converters
Wide bandgap (WBG) power semiconductor devices are increasingly replacing silicon IGBTs in high-power and high-voltage power electronics applications. However, there is a significant gap in the literature regarding efficient testing methodologies for high-power and high-voltage converters under constrained laboratory resources. This paper addresses this gap by presenting comprehensive, hardware-focused testing methodologies for high-power and high-voltage WBG power semiconductor based converters, preceding the control evaluation phase. The proposed methods enable thorough evaluation and evaluation of converter hardware, including device switching characteristics, driving circuit functionality, thermal management performance, insulation integrity, and sustained operation at full power. We utilize the double pulse test (DPT) to characterize switching performance in a two-level phase leg configuration, extract circuit parasitics, and validate magnetic components. The DPT is further applied to optimize gate driving circuits, validate overcurrent protection mechanisms, and measure device on-resistance. Additionally, a multicycle test is introduced to rapidly assess steady-state converter performance and estimate efficiency. Recognizing the critical role of thermal management in high-power converters, our methodologies extend to the experimental extraction of key thermal parameters—such as junction-to-ambient thermal resistance and thermal capacitance—via a heat loss injection method. A correlation method between temperature sensor measurements and junction temperature is presented to enhance the accuracy of device temperature monitoring during tests. To ensure reliability and safety, dielectric withstand tests and partial discharge measurements are conducted at both component and converter levels under conventional 60 Hz sinusoidal and high-frequency PWM waveforms. Finally, we highlight the importance of testing converters under full voltage, current, and thermal conditions through power circulating tests with minimal power consumption, applicable to both non-isolated and isolated high-power converters. Practical examples are provided to demonstrate the effectiveness and applicability of these hardware testing methodologies.
- 9 September 2024
- Published by MDPI AG in Preprints.org
Open AccessHardware Testing Methodology for Wide Bandgap High Power Converters
Wide bandgap (WBG) power semiconductor devices are increasingly replacing silicon IGBTs in high-power and high-voltage power electronics applications. However, there is a significant gap in the literature regarding efficient testing methodologies for high-power and high-voltage converters under constrained laboratory resources. This paper addresses this gap by presenting comprehensive, hardware-focused testing methodologies for high-power and high-voltage WBG power semiconductor based converters, preceding the control evaluation phase. The proposed methods enable thorough evaluation and evaluation of converter hardware, including device switching characteristics, driving circuit functionality, thermal management performance, insulation integrity, and sustained operation at full power. We utilize the double pulse test (DPT) to characterize switching performance in a two-level phase leg configuration, extract circuit parasitics, and validate magnetic components. The DPT is further applied to optimize gate driving circuits, validate overcurrent protection mechanisms, and measure device on-resistance. Additionally, a multicycle test is introduced to rapidly assess steady-state converter performance and estimate efficiency. Recognizing the critical role of thermal management in high-power converters, our methodologies extend to the experimental extraction of key thermal parameters—such as junction-to-ambient thermal resistance and thermal capacitance—via a heat loss injection method. A correlation method between temperature sensor measurements and junction temperature is presented to enhance the accuracy of device temperature monitoring during tests. To ensure reliability and safety, dielectric withstand tests and partial discharge measurements are conducted at both component and converter levels under conventional 60 Hz sinusoidal and high-frequency PWM waveforms. Finally, we highlight the importance of testing converters under full voltage, current, and thermal conditions through power circulating tests with minimal power consumption, applicable to both non-isolated and isolated high-power converters. Practical examples are provided to demonstrate the effectiveness and applicability of these hardware testing methodologies.
- 27 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power Electronics Magazine
- Vol. 11 (2) , 34-38
1.2 kV/400 A SiC Source Turn-Off MOSFET Intelligent Power Module
Excellent switching performances and higher levels of integration are two critical topics for intelligent power modules (IPM). This article proposes a novel and cost effective 1.2 kV/400 A SiC half-bridge power module based on the Source Turn-off (STO) MOSFET. STO MOSFET is a driver integrated MOSFET architecture that can achieve ultra-fast turn-on and turn-off operations beyond the traditional voltage source gate driver approach. A built-in current and temperature monitoring features are also integrated. The IPM integrates discrete SiC devices, direct bond copper (DBC) base plate, STO gate driver, auxiliary power supply, current monitor, temperature monitor, and decoupling caps, making it plug-and-play ready.
- 27 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power Electronics Magazine
- Vol. 11 (2) , 34-38
1.2 kV/400 A SiC Source Turn-Off MOSFET Intelligent Power Module
Excellent switching performances and higher levels of integration are two critical topics for intelligent power modules (IPM). This article proposes a novel and cost effective 1.2 kV/400 A SiC half-bridge power module based on the Source Turn-off (STO) MOSFET. STO MOSFET is a driver integrated MOSFET architecture that can achieve ultra-fast turn-on and turn-off operations beyond the traditional voltage source gate driver approach. A built-in current and temperature monitoring features are also integrated. The IPM integrates discrete SiC devices, direct bond copper (DBC) base plate, STO gate driver, auxiliary power supply, current monitor, temperature monitor, and decoupling caps, making it plug-and-play ready.
- 21 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (6) , 5705-5714
Characterizations of Partial Discharge in Modern Power Electronics
Partial discharge (PD) is a phenomenon often occurring in insulation system defects (cavities), which can significantly affect lifetime and reliability of power electronics components and system. While broad knowledge on PD phenomenology has been achieved under ac sinusoidal voltage, much less work has been discussed to infer PD behavior under emerging high frequency Pulse Width Modulation (PWM) operation conditions. With the introduction of wide bandgap (WBG) power devices to modern power electronics, the insulation voltage stress is high frequency Pulse Width Modulation (PWM) waveforms with high dv/dt. Moreover, in some complex modular power electronics systems face a superimposed electric stress of two different frequencies, namely the grid frequency and the switching frequency of converter operation. This paper comprehensively reviews the PD test platforms utilized in the characterization of high frequency transformers (HFT), power modules, printed circuit board (PCB), and medium voltage (MV) power converters. In addition, this paper compares PD behaviors under 60 Hz sinusoidal waveform and high frequency PWM waveform. The PD mechanism under PWM pulses and the effect of the slew rate, and frequency to PD characterizations are studied. Finally, PD mitigation solutions for modern power electronics components and system are discussed.
- 21 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (6) , 5705-5714
Characterizations of Partial Discharge in Modern Power Electronics
Partial discharge (PD) is a phenomenon often occurring in insulation system defects (cavities), which can significantly affect lifetime and reliability of power electronics components and system. While broad knowledge on PD phenomenology has been achieved under ac sinusoidal voltage, much less work has been discussed to infer PD behavior under emerging high frequency Pulse Width Modulation (PWM) operation conditions. With the introduction of wide bandgap (WBG) power devices to modern power electronics, the insulation voltage stress is high frequency Pulse Width Modulation (PWM) waveforms with high dv/dt. Moreover, in some complex modular power electronics systems face a superimposed electric stress of two different frequencies, namely the grid frequency and the switching frequency of converter operation. This paper comprehensively reviews the PD test platforms utilized in the characterization of high frequency transformers (HFT), power modules, printed circuit board (PCB), and medium voltage (MV) power converters. In addition, this paper compares PD behaviors under 60 Hz sinusoidal waveform and high frequency PWM waveform. The PD mechanism under PWM pulses and the effect of the slew rate, and frequency to PD characterizations are studied. Finally, PD mitigation solutions for modern power electronics components and system are discussed.
- 25 October 2022
- Published by Elsevier in Chemical Engineering Journal
- Vol. 453, 139762
Hydrogen bond and 3D frameworks to reconcile the conflict between safety and detonation performance in energetic metal–organic frameworks
- 25 October 2022
- Published by Elsevier in Chemical Engineering Journal
- Vol. 453, 139762
Hydrogen bond and 3D frameworks to reconcile the conflict between safety and detonation performance in energetic metal–organic frameworks
- 12 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (1) , 112-117
A Novel High Insulation 100 kW Medium Frequency Transformer
High voltage insulation and thermal management are the two major challenges in a high-power medium frequency transformer (MFT) design. This letter proposes novel insulation and cooling structure with potted windings in a 100 kW MFT with two FINEMET FT-3TL magnetic cores and parallel-concentric winding structure. For the first time, a three-dimensional printed bobbin with heatsink fins is demonstrated. The 100 kW MFT achieves a power density of 10.6 kW/L and a partial discharge inception voltage of 20 kV peak. The MFT is applied in a dual active bridge based medium voltage solid state transformer, achieving a peak efficiency of 98.2% at 40 kW and 97.5% at 100 kW. The MFT itself has a 99.735% efficiency with superior thermal performance at 100 kW output power.
- 12 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (1) , 112-117
A Novel High Insulation 100 kW Medium Frequency Transformer
High voltage insulation and thermal management are the two major challenges in a high-power medium frequency transformer (MFT) design. This letter proposes novel insulation and cooling structure with potted windings in a 100 kW MFT with two FINEMET FT-3TL magnetic cores and parallel-concentric winding structure. For the first time, a three-dimensional printed bobbin with heatsink fins is demonstrated. The 100 kW MFT achieves a power density of 10.6 kW/L and a partial discharge inception voltage of 20 kV peak. The MFT is applied in a dual active bridge based medium voltage solid state transformer, achieving a peak efficiency of 98.2% at 40 kW and 97.5% at 100 kW. The MFT itself has a 99.735% efficiency with superior thermal performance at 100 kW output power.