JCJie Chen

Jie Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jie Chen has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Study on Wind Resistance Performance of Transmission Tower Using Fixture-Type Reinforcement Device

    by Xiao Tan, Yaodong Liu, Ben Sha, Nailong Zhang, Jie Chen, Hao Wang, Jianxiao Mao

    Transmission towers are an important component of the electric system, and their tall structural characteristics make them susceptible to failure under strong winds. Therefore, it is crucial to enhance the wind resistance of the transmission tower structures. This paper uses the finite element method to investigate the influence of a fixture-type reinforcement device (FRD) on the load-bearing performance of the transmission tower structure and explores the effects of different numbers of fixture pairs on the reinforcement. Based on this, the paper further analyzes the stress characteristics and failure modes of a typical tower structure under wind loads in two directions and investigates the influence of different reinforcement lengths on the wind resistance performance of the tower structure. The research results indicate that the FRD can effectively improve the deformation mode and failure characteristics of steel components under axial load. At the same time, using the FRD can effectively reduce the deformation of tower structures under strong wind, and only reinforcing three angled steel components can reduce the tower top displacement by about 55% and more.


  • Self-learning Diagnosis of Transmission Line Fault Type Based on Deep Forest and SMOTE

    by Xiao Tan, Guoji Chang, Gang Qiu, Jinjin Shi, Jie Chen, Qiwei Wu


  • Open Access

    Influence of Arc Size on the Ignition and Flame Propagation of Cable Fire

    by Chenying Li, Jie Chen, Wei Zhang, Libing Hu, Jingying Cao, Jianjun Liu, Zhenyu Zhu, Shuqun Wu

    Cable fire caused by arc faults is one of the essential factors threatening the safe operation of a power system. The ignition and flame propagation of cable fire dependent on the characteristics of the arc discharge is lackingin in-depth understanding at present. In this work, with the constant electric power deposited into the arc discharge, the effects of arc size on the ignition and flame propagation of 110 kV XLPE cable fire are investigated for the first time. The arc size is changed by varying the gap distance of electrodes from 1.5 cm to 2.5 cm. It is interesting to find that the larger the arc size is, the faster the cable fire is ignited and propagates, and the larger the damaged area of the sheath of the cable is. Therein, when the gap distance increases from 1.3 cm to 3.1 cm, the equivalent impedance and the length of the arc discharge increase nearly seven times and three times, respectively. However, the gas temperature of the arc decreases slightly from 2280 K to 2100 K. In addition, a 3D model of the cable fire ignited by arc discharge is computed by Pyrosim software with fire dynamic simulation (FDS) module. Simulated results show that as the arc size increases, the cable fire is ignited faster, the flame propagates both vertically and horizontally increasing significantly, which is agreed well with the experimental results. This study deepens the understanding of the cable fire ignited by arc discharge and therefore it is useful for the evaluation and prevention of cable fire.