Jie Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jie Chen has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Xiao Tan
Electric Power Research Institute of State Grid Jiangsu Electric Power Co., Ltd., Nanjing 211103, China
2 shared publications - Ben Sha
College of Civil Engineering, Nanjing Forestry University, Nanjing 210037, China
1 shared publication - Chenying Li
State Grid Jiangsu Electric Power Company, Nanjing 211103, China
1 shared publication Gang Qiu
State Grid Jiangsu Electric Power Co., Ltd. Research Institute
1 shared publicationGuoji Chang
State Grid Jiangsu Electric Power Co., Ltd., Ultra High Voltage Branch
1 shared publication- Hao Wang
Key Laboratory of C&PC Structures of Ministry of Education, Southeast University, Nanjing, China
1 shared publication
Latest Publications
- Open Access
- 14 January 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (2) , 747
Study on Wind Resistance Performance of Transmission Tower Using Fixture-Type Reinforcement Device
Transmission towers are an important component of the electric system, and their tall structural characteristics make them susceptible to failure under strong winds. Therefore, it is crucial to enhance the wind resistance of the transmission tower structures. This paper uses the finite element method to investigate the influence of a fixture-type reinforcement device (FRD) on the load-bearing performance of the transmission tower structure and explores the effects of different numbers of fixture pairs on the reinforcement. Based on this, the paper further analyzes the stress characteristics and failure modes of a typical tower structure under wind loads in two directions and investigates the influence of different reinforcement lengths on the wind resistance performance of the tower structure. The research results indicate that the FRD can effectively improve the deformation mode and failure characteristics of steel components under axial load. At the same time, using the FRD can effectively reduce the deformation of tower structures under strong wind, and only reinforcing three angled steel components can reduce the tower top displacement by about 55% and more.
- 14 January 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (2) , 747
Open AccessStudy on Wind Resistance Performance of Transmission Tower Using Fixture-Type Reinforcement Device
Transmission towers are an important component of the electric system, and their tall structural characteristics make them susceptible to failure under strong winds. Therefore, it is crucial to enhance the wind resistance of the transmission tower structures. This paper uses the finite element method to investigate the influence of a fixture-type reinforcement device (FRD) on the load-bearing performance of the transmission tower structure and explores the effects of different numbers of fixture pairs on the reinforcement. Based on this, the paper further analyzes the stress characteristics and failure modes of a typical tower structure under wind loads in two directions and investigates the influence of different reinforcement lengths on the wind resistance performance of the tower structure. The research results indicate that the FRD can effectively improve the deformation mode and failure characteristics of steel components under axial load. At the same time, using the FRD can effectively reduce the deformation of tower structures under strong wind, and only reinforcing three angled steel components can reduce the tower top displacement by about 55% and more.
- 31 December 2023
- Published by Springer Nature
- p. 585-593
Self-learning Diagnosis of Transmission Line Fault Type Based on Deep Forest and SMOTE
- 31 December 2023
- Published by Springer Nature
- p. 585-593
Self-learning Diagnosis of Transmission Line Fault Type Based on Deep Forest and SMOTE
- Open Access
Influence of Arc Size on the Ignition and Flame Propagation of Cable Fire
Cable fire caused by arc faults is one of the essential factors threatening the safe operation of a power system. The ignition and flame propagation of cable fire dependent on the characteristics of the arc discharge is lackingin in-depth understanding at present. In this work, with the constant electric power deposited into the arc discharge, the effects of arc size on the ignition and flame propagation of 110 kV XLPE cable fire are investigated for the first time. The arc size is changed by varying the gap distance of electrodes from 1.5 cm to 2.5 cm. It is interesting to find that the larger the arc size is, the faster the cable fire is ignited and propagates, and the larger the damaged area of the sheath of the cable is. Therein, when the gap distance increases from 1.3 cm to 3.1 cm, the equivalent impedance and the length of the arc discharge increase nearly seven times and three times, respectively. However, the gas temperature of the arc decreases slightly from 2280 K to 2100 K. In addition, a 3D model of the cable fire ignited by arc discharge is computed by Pyrosim software with fire dynamic simulation (FDS) module. Simulated results show that as the arc size increases, the cable fire is ignited faster, the flame propagates both vertically and horizontally increasing significantly, which is agreed well with the experimental results. This study deepens the understanding of the cable fire ignited by arc discharge and therefore it is useful for the evaluation and prevention of cable fire.
Open AccessInfluence of Arc Size on the Ignition and Flame Propagation of Cable Fire
Cable fire caused by arc faults is one of the essential factors threatening the safe operation of a power system. The ignition and flame propagation of cable fire dependent on the characteristics of the arc discharge is lackingin in-depth understanding at present. In this work, with the constant electric power deposited into the arc discharge, the effects of arc size on the ignition and flame propagation of 110 kV XLPE cable fire are investigated for the first time. The arc size is changed by varying the gap distance of electrodes from 1.5 cm to 2.5 cm. It is interesting to find that the larger the arc size is, the faster the cable fire is ignited and propagates, and the larger the damaged area of the sheath of the cable is. Therein, when the gap distance increases from 1.3 cm to 3.1 cm, the equivalent impedance and the length of the arc discharge increase nearly seven times and three times, respectively. However, the gas temperature of the arc decreases slightly from 2280 K to 2100 K. In addition, a 3D model of the cable fire ignited by arc discharge is computed by Pyrosim software with fire dynamic simulation (FDS) module. Simulated results show that as the arc size increases, the cable fire is ignited faster, the flame propagates both vertically and horizontally increasing significantly, which is agreed well with the experimental results. This study deepens the understanding of the cable fire ignited by arc discharge and therefore it is useful for the evaluation and prevention of cable fire.