Daniele Mazierli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Daniele Mazierli has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Ramalli
Department of Information Engineering, University of Florence, Florence, Italy
10 shared publications - Piero Tortoli
Department of Information Engineering, University of Florence, Florence, Italy
6 shared publications Piero Tortoli
University of Florence,Dept. of Information Engineering,Florence,Italy
5 shared publications- Laura Peralta
Research Department of Surgical and Interventional Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, SE1 7EH, United Kingdom
4 shared publications Joseph V Hajnal
Kings College London,Dept of Biomedical Engineering,London,UK
3 shared publicationsLaura Peralta
Kings College London,Dept. of Surgical Interventional Engineering,London,UK
3 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (1) , 404-416
Multi-Probe Vector Velocity Estimation in Deep and Large Regions of Interest: A Simulation Study
Objective: The current vector velocity measurement techniques are typically limited by probe apertures, which restrict their use to superficial vessels. This work introduces a high frame rate method based on the use of multiple array probes transmitting defocused beams and shows that such a method permits accurate and precise measurements of blood velocities in deep and large regions/volumes of interest. Methods: Multiple probes are positioned to investigate a common region of interest and activated in a sequence. The corresponding phase shifts are estimated and combined through a least square error approach to derive the velocity vector. The method's performance has been quantitatively evaluated in both 2-D and 3-D scenarios through simulations based on either two linear- or three matrix sparse-array probes. Results: Good estimations of both module (average rmse(v) 11.9% of vmax) and direction (average rmse(α) 2.3° and rmse(β) 8.0°) of the velocity vectors have been obtained. The corresponding vector velocity frames cover wide areas or volumes even around depths as high as 80 mm. Conclusions: This simulation work demonstrates that multi-probe configurations can be exploited to measure the 2-D or 3-D flow velocity accurately and precisely in deep and large regions of interest. Significance: In a clinical scenario, for example, the method could be exploited for velocity estimation in the abdominal region where large and deep vessels, such as the aorta, are located.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (1) , 404-416
Open AccessMulti-Probe Vector Velocity Estimation in Deep and Large Regions of Interest: A Simulation Study
Objective: The current vector velocity measurement techniques are typically limited by probe apertures, which restrict their use to superficial vessels. This work introduces a high frame rate method based on the use of multiple array probes transmitting defocused beams and shows that such a method permits accurate and precise measurements of blood velocities in deep and large regions/volumes of interest. Methods: Multiple probes are positioned to investigate a common region of interest and activated in a sequence. The corresponding phase shifts are estimated and combined through a least square error approach to derive the velocity vector. The method's performance has been quantitatively evaluated in both 2-D and 3-D scenarios through simulations based on either two linear- or three matrix sparse-array probes. Results: Good estimations of both module (average rmse(v) 11.9% of vmax) and direction (average rmse(α) 2.3° and rmse(β) 8.0°) of the velocity vectors have been obtained. The corresponding vector velocity frames cover wide areas or volumes even around depths as high as 80 mm. Conclusions: This simulation work demonstrates that multi-probe configurations can be exploited to measure the 2-D or 3-D flow velocity accurately and precisely in deep and large regions of interest. Significance: In a clinical scenario, for example, the method could be exploited for velocity estimation in the abdominal region where large and deep vessels, such as the aorta, are located.
- Open Access
- 4 July 2025
- Published by Elsevier in Ultrasonics
- Vol. 155, 107731
Specific Filtered Delay Multiply and Sum beamforming for coherent multi-transducer ultrasound imaging
- 4 July 2025
- Published by Elsevier in Ultrasonics
- Vol. 155, 107731
Open AccessSpecific Filtered Delay Multiply and Sum beamforming for coherent multi-transducer ultrasound imaging
- Open Access
- 2 October 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (19) , 10924
On the Arrays Distribution, Scan Sequence and Apodization in Coherent Dual-Array Ultrasound Imaging Systems
Coherent multi-transducer ultrasound (CoMTUS) imaging creates an extended effective aperture through the coherent combination of multiple arrays, which results in images with enhanced resolution, extended field-of-view, and higher sensitivity. However, this also creates a large discontinuous effective aperture that presents additional challenges for current beamforming methods. The discontinuities may increase the level of grating and side lobes and degrade contrast. Also, direct transmissions between multiple arrays, happening at certain transducer relative positions, produce undesirable cross-talk artifacts. Hence, the position of the transducers and the scan sequence play key roles in the beamforming algorithm and imaging performance of CoMTUS. This work investigates the role of the distribution of the individual arrays and the scan sequence in the imaging performance of a coherent dual-array system. First, the imaging performance for different configurations was assessed numerically using the point-spread-function, and then optimized settings were tested on a tissue mimicking phantom. Finally, a subset of the proposed optimum imaging schemes was experimentally validated on two synchronized ULA OP-256 systems equipped with identical linear arrays. Results show that CoMTUS imaging performance can be enhanced by optimizing the relative position of the arrays and the scan sequence together, and that the use of apodization can reduce cross-talk artifacts without degrading spatial resolution. Adding weighted compounding further decreases artifacts and helps to compensate for the differences in the brightness across the image. Setting the maximum steering angle according to the spatial configuration of the arrays reduces the sidelobe energy up to 10 dB plus an extra 4 dB reduction is possible when increasing the number of PWs compounded.
- 2 October 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (19) , 10924
Open AccessOn the Arrays Distribution, Scan Sequence and Apodization in Coherent Dual-Array Ultrasound Imaging Systems
Coherent multi-transducer ultrasound (CoMTUS) imaging creates an extended effective aperture through the coherent combination of multiple arrays, which results in images with enhanced resolution, extended field-of-view, and higher sensitivity. However, this also creates a large discontinuous effective aperture that presents additional challenges for current beamforming methods. The discontinuities may increase the level of grating and side lobes and degrade contrast. Also, direct transmissions between multiple arrays, happening at certain transducer relative positions, produce undesirable cross-talk artifacts. Hence, the position of the transducers and the scan sequence play key roles in the beamforming algorithm and imaging performance of CoMTUS. This work investigates the role of the distribution of the individual arrays and the scan sequence in the imaging performance of a coherent dual-array system. First, the imaging performance for different configurations was assessed numerically using the point-spread-function, and then optimized settings were tested on a tissue mimicking phantom. Finally, a subset of the proposed optimum imaging schemes was experimentally validated on two synchronized ULA OP-256 systems equipped with identical linear arrays. Results show that CoMTUS imaging performance can be enhanced by optimizing the relative position of the arrays and the scan sequence together, and that the use of apodization can reduce cross-talk artifacts without degrading spatial resolution. Adding weighted compounding further decreases artifacts and helps to compensate for the differences in the brightness across the image. Setting the maximum steering angle according to the spatial configuration of the arrays reduces the sidelobe energy up to 10 dB plus an extra 4 dB reduction is possible when increasing the number of PWs compounded.
- 1 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 70 (3) , 197-206
3-D Coherent Multitransducer Ultrasound Imaging With Sparse Spiral Arrays
Coherent multitransducer ultrasound (CoMTUS) creates an extended effective aperture through the coherent combination of multiple arrays, which results in images with enhanced resolution, extended field-of-view, and higher sensitivity. The subwavelength localization accuracy of the multiple transducers required to coherently beamform the data is achieved by using the echoes backscattered from targeted points. In this study, CoMTUS is implemented and demonstrated for the first time in 3-D imaging using a pair of 256-element 2-D sparse spiral arrays, which keep the channel count low and limit the amount of data to be processed. The imaging performance of the method was investigated using both simulations and phantom tests. The feasibility of free-hand operation is also experimentally demonstrated. Results show that, in comparison with a single dense array system using the same total number of active elements, the proposed CoMTUS system improves spatial resolution (up to ten times) in the direction where both arrays are aligned, contrast-to-noise ratio (CNR; up to 46%), and generalized CNR (gCNR; up to 15%). Overall, CoMTUS shows a narrower main lobe and higher CNR, which results in an increased dynamic range and better target detectability.
- 1 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 70 (3) , 197-206
3-D Coherent Multitransducer Ultrasound Imaging With Sparse Spiral Arrays
Coherent multitransducer ultrasound (CoMTUS) creates an extended effective aperture through the coherent combination of multiple arrays, which results in images with enhanced resolution, extended field-of-view, and higher sensitivity. The subwavelength localization accuracy of the multiple transducers required to coherently beamform the data is achieved by using the echoes backscattered from targeted points. In this study, CoMTUS is implemented and demonstrated for the first time in 3-D imaging using a pair of 256-element 2-D sparse spiral arrays, which keep the channel count low and limit the amount of data to be processed. The imaging performance of the method was investigated using both simulations and phantom tests. The feasibility of free-hand operation is also experimentally demonstrated. Results show that, in comparison with a single dense array system using the same total number of active elements, the proposed CoMTUS system improves spatial resolution (up to ten times) in the direction where both arrays are aligned, contrast-to-noise ratio (CNR; up to 46%), and generalized CNR (gCNR; up to 15%). Overall, CoMTUS shows a narrower main lobe and higher CNR, which results in an increased dynamic range and better target detectability.
- 10 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Towards multi-probe high frame rate volumetric vector Doppler imaging: a feasibility study
The Doppler approach more frequently used for estimating two components of the velocity vector is based on the use of the “dual beams” associated with either two single-element probes or two sub-apertures of a linear array. With the diffusion of high frame rate (HFR) sequences, these methods have been adapted to the investigation of a planar region of interest (ROI). In this study, we evaluate the feasibility of using multiple 2-D sparse array probes to extend HFR vector Doppler imaging to a 3-D ROI. The results of this work confirm that accurate estimations of the velocity can be obtained. Our results show bias and standard deviation errors below 4.5 % and 13.0 %, respectively, and an achievable rate of 750 volumes per second.
- 10 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Towards multi-probe high frame rate volumetric vector Doppler imaging: a feasibility study
The Doppler approach more frequently used for estimating two components of the velocity vector is based on the use of the “dual beams” associated with either two single-element probes or two sub-apertures of a linear array. With the diffusion of high frame rate (HFR) sequences, these methods have been adapted to the investigation of a planar region of interest (ROI). In this study, we evaluate the feasibility of using multiple 2-D sparse array probes to extend HFR vector Doppler imaging to a 3-D ROI. The results of this work confirm that accurate estimations of the velocity can be obtained. Our results show bias and standard deviation errors below 4.5 % and 13.0 %, respectively, and an achievable rate of 750 volumes per second.
- 10 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Experimental demonstration of the coherent use of two sparse arrays for 3-D imaging
Coherent multi-transducer ultrasound (CoMTUS) creates an extended effective aperture through the coherent combination of multiple arrays. In this study, for the first time, CoMTUS is experimentally implemented and demonstrated in 3-D using two synchronized ULA-OP 256 systems controlling a pair of 2-D sparse arrays. Results show that, in comparison to a single dense spiral array system using the same total number of active elements, the proposed CoMTUS system formed by two 2-D 256-element sparse spiral arrays leads to significant improvements in spatial resolution, in the direction where both arrays are aligned, and higher contrast-to-noise-ratio and generalized contrast-to-noise-ratio.
- 10 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Experimental demonstration of the coherent use of two sparse arrays for 3-D imaging
Coherent multi-transducer ultrasound (CoMTUS) creates an extended effective aperture through the coherent combination of multiple arrays. In this study, for the first time, CoMTUS is experimentally implemented and demonstrated in 3-D using two synchronized ULA-OP 256 systems controlling a pair of 2-D sparse arrays. Results show that, in comparison to a single dense spiral array system using the same total number of active elements, the proposed CoMTUS system formed by two 2-D 256-element sparse spiral arrays leads to significant improvements in spatial resolution, in the direction where both arrays are aligned, and higher contrast-to-noise-ratio and generalized contrast-to-noise-ratio.
- 10 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Specific Delay Multiply and Sum Beamforming for 2-D and 3-D Coherent Multi-Transducer Ultrasound imaging
Coherent multi-transducer ultrasound (CoMTUS) imaging enables the use of multiple arrays as one large effective aperture. This yields images with enlarged field-of-view, improved resolution, and higher SNR. However, creating a large but discontinuous effective aperture increases the grating and side lobe levels and generates cross-talk artifacts from the direct transmissions between arrays. These additional challenges can degrade the contrast of the images obtained through the classic Delay and Sum (DAS) beamforming algorithm. This study investigates the use of an alternative nonlinear beamforming algorithm, the Delay Multiply and Sum (DMAS), to improve contrast and reduce cross-talk artifacts in CoMTUS. We adapted the original DMAS beamforming algorithm to the specific effective aperture of CoMTUS and tested its performance in a coherent dual-array system for both 2-D and 3-D imaging. The comparison between images obtained through CoMTUS DMAS and DAS was investigated by both 2-D and 3-D simulations and experiments. DMAS was shown effective to lower the side lobes and the noise floor, thus improving the detectability of cystic lesions.
- 10 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Specific Delay Multiply and Sum Beamforming for 2-D and 3-D Coherent Multi-Transducer Ultrasound imaging
Coherent multi-transducer ultrasound (CoMTUS) imaging enables the use of multiple arrays as one large effective aperture. This yields images with enlarged field-of-view, improved resolution, and higher SNR. However, creating a large but discontinuous effective aperture increases the grating and side lobe levels and generates cross-talk artifacts from the direct transmissions between arrays. These additional challenges can degrade the contrast of the images obtained through the classic Delay and Sum (DAS) beamforming algorithm. This study investigates the use of an alternative nonlinear beamforming algorithm, the Delay Multiply and Sum (DMAS), to improve contrast and reduce cross-talk artifacts in CoMTUS. We adapted the original DMAS beamforming algorithm to the specific effective aperture of CoMTUS and tested its performance in a coherent dual-array system for both 2-D and 3-D imaging. The comparison between images obtained through CoMTUS DMAS and DAS was investigated by both 2-D and 3-D simulations and experiments. DMAS was shown effective to lower the side lobes and the noise floor, thus improving the detectability of cystic lesions.
- Open Access
- 28 June 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (13) , 6562
Requirements and Hardware Limitations of High-Frame-Rate 3-D Ultrasound Imaging Systems
The spread of high frame rate and 3-D imaging techniques has raised pressing requirements for ultrasound systems. In particular, the processing power and data transfer rate requirements may be so demanding to hinder the real-time (RT) implementation of such techniques. This paper first analyzes the general requirements involved in RT ultrasound systems. Then, it identifies the main bottlenecks in the receiving section of a specific RT scanner, the ULA-OP 256, which is one of the most powerful available open scanners and may therefore be assumed as a reference. This case study has evidenced that the “star” topology, used to digitally interconnect the system’s boards, may easily saturate the data transfer bandwidth, thus impacting the achievable frame/volume rates in RT. The architecture of the digital scanner was exploited to tackle the bottlenecks by enabling a new “ring“ communication topology. Experimental 2-D and 3-D high-frame-rate imaging tests were conducted to evaluate the frame rates achievable with both interconnection modalities. It is shown that the ring topology enables up to 4400 frames/s and 510 volumes/s, with mean increments of +230% (up to +620%) compared to the star topology.
- 28 June 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (13) , 6562
Open AccessRequirements and Hardware Limitations of High-Frame-Rate 3-D Ultrasound Imaging Systems
The spread of high frame rate and 3-D imaging techniques has raised pressing requirements for ultrasound systems. In particular, the processing power and data transfer rate requirements may be so demanding to hinder the real-time (RT) implementation of such techniques. This paper first analyzes the general requirements involved in RT ultrasound systems. Then, it identifies the main bottlenecks in the receiving section of a specific RT scanner, the ULA-OP 256, which is one of the most powerful available open scanners and may therefore be assumed as a reference. This case study has evidenced that the “star” topology, used to digitally interconnect the system’s boards, may easily saturate the data transfer bandwidth, thus impacting the achievable frame/volume rates in RT. The architecture of the digital scanner was exploited to tackle the bottlenecks by enabling a new “ring“ communication topology. Experimental 2-D and 3-D high-frame-rate imaging tests were conducted to evaluate the frame rates achievable with both interconnection modalities. It is shown that the ring topology enables up to 4400 frames/s and 510 volumes/s, with mean increments of +230% (up to +620%) compared to the star topology.
- 11 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Real-Time Ultrasound Open Platform with an Extendable Number of Channels
Ultrasound open platforms are ideal instruments to experiment innovative modalities in transmission and reception. So far, the high number of channels, involved in applications based on 2-D arrays, has been managed through complex combinations of scanners and personal computers, at the expense of ease of use, portability, and real-time performance. This work presents a new flexible architecture, based on the full (hardware and software) synchronization of multiple ULA-OP 256 scanners, in a Master-Slave architecture, and controlled by a single computer. For the hardware synchronization, a Master scanner provides two digital signals (clock and transmission start) to the Slave scanners, while the software synchronization is managed by two purposely developed MATLAB classes that allow the user to interface the scanners as a single system. To demonstrate the effectiveness of the architecture, a 512-channel prototype, composed of two ULA-OP 256 connected to a host PC and to a sparse array, was implemented and tested through applications that demonstrate the high real-time processing power.
- 11 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Real-Time Ultrasound Open Platform with an Extendable Number of Channels
Ultrasound open platforms are ideal instruments to experiment innovative modalities in transmission and reception. So far, the high number of channels, involved in applications based on 2-D arrays, has been managed through complex combinations of scanners and personal computers, at the expense of ease of use, portability, and real-time performance. This work presents a new flexible architecture, based on the full (hardware and software) synchronization of multiple ULA-OP 256 scanners, in a Master-Slave architecture, and controlled by a single computer. For the hardware synchronization, a Master scanner provides two digital signals (clock and transmission start) to the Slave scanners, while the software synchronization is managed by two purposely developed MATLAB classes that allow the user to interface the scanners as a single system. To demonstrate the effectiveness of the architecture, a 512-channel prototype, composed of two ULA-OP 256 connected to a host PC and to a sparse array, was implemented and tested through applications that demonstrate the high real-time processing power.
- 11 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Experimental study on the association among flow profile shape, systemic and local hemodynamics, wave reflections, based on Vector Doppler imaging
Blood flow velocity profile in large arteries, although commonly assumed parabolic, quite often shows more complex patterns. The aim of this study was to investigate possible correlations between the different flow patterns and their potential determinants like systemic hemodynamic factors as well as local vessel geometry, distensibility and wave reflections. The study focuses on carotid (common, CCA, and internal, ICA) and femoral (common, CFA) arteries in normal subjects. The velocity profiles were obtained through the Multi Line Vector Doppler (MLVD) approach implemented in the ULA-OP 256 scanner, and their shape was quantified through the Bluntness Index (BI), i.e. the ratio between peak and cross-section averaged velocity. Possible correlations among BI and the other systemic and local parameters were investigated. We found that in healthy subjects, plaque free, the profile shape in the CCA is almost parabolic, but it is not in ICA and CFA. Moreover, the profile shape in the carotid is mainly affected by systemic hemodynamic factors, while local factors are more relevant for the profile in CFA.
- 11 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Experimental study on the association among flow profile shape, systemic and local hemodynamics, wave reflections, based on Vector Doppler imaging
Blood flow velocity profile in large arteries, although commonly assumed parabolic, quite often shows more complex patterns. The aim of this study was to investigate possible correlations between the different flow patterns and their potential determinants like systemic hemodynamic factors as well as local vessel geometry, distensibility and wave reflections. The study focuses on carotid (common, CCA, and internal, ICA) and femoral (common, CFA) arteries in normal subjects. The velocity profiles were obtained through the Multi Line Vector Doppler (MLVD) approach implemented in the ULA-OP 256 scanner, and their shape was quantified through the Bluntness Index (BI), i.e. the ratio between peak and cross-section averaged velocity. Possible correlations among BI and the other systemic and local parameters were investigated. We found that in healthy subjects, plaque free, the profile shape in the CCA is almost parabolic, but it is not in ICA and CFA. Moreover, the profile shape in the carotid is mainly affected by systemic hemodynamic factors, while local factors are more relevant for the profile in CFA.