  • Open Access

    Multi-Probe Vector Velocity Estimation in Deep and Large Regions of Interest: A Simulation Study

    by Daniele Mazierli, Piero Tortoli, Laura Peralta, Alessandro Ramalli

    Objective: The current vector velocity measurement techniques are typically limited by probe apertures, which restrict their use to superficial vessels. This work introduces a high frame rate method based on the use of multiple array probes transmitting defocused beams and shows that such a method permits accurate and precise measurements of blood velocities in deep and large regions/volumes of interest. Methods: Multiple probes are positioned to investigate a common region of interest and activated in a sequence. The corresponding phase shifts are estimated and combined through a least square error approach to derive the velocity vector. The method's performance has been quantitatively evaluated in both 2-D and 3-D scenarios through simulations based on either two linear- or three matrix sparse-array probes. Results: Good estimations of both module (average rmse(v) 11.9% of vmax) and direction (average rmse(α) 2.3° and rmse(β) 8.0°) of the velocity vectors have been obtained. The corresponding vector velocity frames cover wide areas or volumes even around depths as high as 80 mm. Conclusions: This simulation work demonstrates that multi-probe configurations can be exploited to measure the 2-D or 3-D flow velocity accurately and precisely in deep and large regions of interest. Significance: In a clinical scenario, for example, the method could be exploited for velocity estimation in the abdominal region where large and deep vessels, such as the aorta, are located.


  • Open Access

    Specific Filtered Delay Multiply and Sum beamforming for coherent multi-transducer ultrasound imaging

    by Paul Dryburgh, Daniele Mazierli, Joseph V. Hajnal, Piero Tortoli, Alessandro Ramalli, Laura Peralta


  • Open Access

    On the Arrays Distribution, Scan Sequence and Apodization in Coherent Dual-Array Ultrasound Imaging Systems

    by Laura Peralta, Daniele Mazierli, Kirsten Christensen-Jeffries, Alessandro Ramalli, Piero Tortoli, Joseph V. Hajnal

    Coherent multi-transducer ultrasound (CoMTUS) imaging creates an extended effective aperture through the coherent combination of multiple arrays, which results in images with enhanced resolution, extended field-of-view, and higher sensitivity. However, this also creates a large discontinuous effective aperture that presents additional challenges for current beamforming methods. The discontinuities may increase the level of grating and side lobes and degrade contrast. Also, direct transmissions between multiple arrays, happening at certain transducer relative positions, produce undesirable cross-talk artifacts. Hence, the position of the transducers and the scan sequence play key roles in the beamforming algorithm and imaging performance of CoMTUS. This work investigates the role of the distribution of the individual arrays and the scan sequence in the imaging performance of a coherent dual-array system. First, the imaging performance for different configurations was assessed numerically using the point-spread-function, and then optimized settings were tested on a tissue mimicking phantom. Finally, a subset of the proposed optimum imaging schemes was experimentally validated on two synchronized ULA OP-256 systems equipped with identical linear arrays. Results show that CoMTUS imaging performance can be enhanced by optimizing the relative position of the arrays and the scan sequence together, and that the use of apodization can reduce cross-talk artifacts without degrading spatial resolution. Adding weighted compounding further decreases artifacts and helps to compensate for the differences in the brightness across the image. Setting the maximum steering angle according to the spatial configuration of the arrays reduces the sidelobe energy up to 10 dB plus an extra 4 dB reduction is possible when increasing the number of PWs compounded.


  • 3-D Coherent Multitransducer Ultrasound Imaging With Sparse Spiral Arrays

    by Laura Peralta, Daniele Mazierli, Alberto Gomez, Joseph V Hajnal, Piero Tortoli, Alessandro Ramalli

    Coherent multitransducer ultrasound (CoMTUS) creates an extended effective aperture through the coherent combination of multiple arrays, which results in images with enhanced resolution, extended field-of-view, and higher sensitivity. The subwavelength localization accuracy of the multiple transducers required to coherently beamform the data is achieved by using the echoes backscattered from targeted points. In this study, CoMTUS is implemented and demonstrated for the first time in 3-D imaging using a pair of 256-element 2-D sparse spiral arrays, which keep the channel count low and limit the amount of data to be processed. The imaging performance of the method was investigated using both simulations and phantom tests. The feasibility of free-hand operation is also experimentally demonstrated. Results show that, in comparison with a single dense array system using the same total number of active elements, the proposed CoMTUS system improves spatial resolution (up to ten times) in the direction where both arrays are aligned, contrast-to-noise ratio (CNR; up to 46%), and generalized CNR (gCNR; up to 15%). Overall, CoMTUS shows a narrower main lobe and higher CNR, which results in an increased dynamic range and better target detectability.


  • Towards multi-probe high frame rate volumetric vector Doppler imaging: a feasibility study

    by Daniele Mazierli, Laura Peralta, Joseph V Hajnal, Alessandro Ramalli, Piero Tortoli

    The Doppler approach more frequently used for estimating two components of the velocity vector is based on the use of the “dual beams” associated with either two single-element probes or two sub-apertures of a linear array. With the diffusion of high frame rate (HFR) sequences, these methods have been adapted to the investigation of a planar region of interest (ROI). In this study, we evaluate the feasibility of using multiple 2-D sparse array probes to extend HFR vector Doppler imaging to a 3-D ROI. The results of this work confirm that accurate estimations of the velocity can be obtained. Our results show bias and standard deviation errors below 4.5 % and 13.0 %, respectively, and an achievable rate of 750 volumes per second.


  • Experimental demonstration of the coherent use of two sparse arrays for 3-D imaging

    by Laura Peralta, Daniele Mazierli, Alberto Gomez, Joseph V Hajnal, Piero Tortoli, Alessandro Ramalli

    Coherent multi-transducer ultrasound (CoMTUS) creates an extended effective aperture through the coherent combination of multiple arrays. In this study, for the first time, CoMTUS is experimentally implemented and demonstrated in 3-D using two synchronized ULA-OP 256 systems controlling a pair of 2-D sparse arrays. Results show that, in comparison to a single dense spiral array system using the same total number of active elements, the proposed CoMTUS system formed by two 2-D 256-element sparse spiral arrays leads to significant improvements in spatial resolution, in the direction where both arrays are aligned, and higher contrast-to-noise-ratio and generalized contrast-to-noise-ratio.


  • Specific Delay Multiply and Sum Beamforming for 2-D and 3-D Coherent Multi-Transducer Ultrasound imaging

    by Laura Peralta, Daniele Mazierli, Joseph V Hajnal, Piero Tortoli, Alessandro Ramalli

    Coherent multi-transducer ultrasound (CoMTUS) imaging enables the use of multiple arrays as one large effective aperture. This yields images with enlarged field-of-view, improved resolution, and higher SNR. However, creating a large but discontinuous effective aperture increases the grating and side lobe levels and generates cross-talk artifacts from the direct transmissions between arrays. These additional challenges can degrade the contrast of the images obtained through the classic Delay and Sum (DAS) beamforming algorithm. This study investigates the use of an alternative nonlinear beamforming algorithm, the Delay Multiply and Sum (DMAS), to improve contrast and reduce cross-talk artifacts in CoMTUS. We adapted the original DMAS beamforming algorithm to the specific effective aperture of CoMTUS and tested its performance in a coherent dual-array system for both 2-D and 3-D imaging. The comparison between images obtained through CoMTUS DMAS and DAS was investigated by both 2-D and 3-D simulations and experiments. DMAS was shown effective to lower the side lobes and the noise floor, thus improving the detectability of cystic lesions.


  • Open Access

    Requirements and Hardware Limitations of High-Frame-Rate 3-D Ultrasound Imaging Systems

    by Claudio Giangrossi, Alessandro Ramalli, Alessandro Dallai, Daniele Mazierli, Valentino Meacci, Enrico Boni, Piero Tortoli

    The spread of high frame rate and 3-D imaging techniques has raised pressing requirements for ultrasound systems. In particular, the processing power and data transfer rate requirements may be so demanding to hinder the real-time (RT) implementation of such techniques. This paper first analyzes the general requirements involved in RT ultrasound systems. Then, it identifies the main bottlenecks in the receiving section of a specific RT scanner, the ULA-OP 256, which is one of the most powerful available open scanners and may therefore be assumed as a reference. This case study has evidenced that the “star” topology, used to digitally interconnect the system’s boards, may easily saturate the data transfer bandwidth, thus impacting the achievable frame/volume rates in RT. The architecture of the digital scanner was exploited to tackle the bottlenecks by enabling a new “ring“ communication topology. Experimental 2-D and 3-D high-frame-rate imaging tests were conducted to evaluate the frame rates achievable with both interconnection modalities. It is shown that the ring topology enables up to 4400 frames/s and 510 volumes/s, with mean increments of +230% (up to +620%) compared to the star topology.


  • Real-Time Ultrasound Open Platform with an Extendable Number of Channels

    by Daniele Mazierli, Alessandro Ramalli, Enrico Boni, Francesco Guidi, Piero Tortoli

    Ultrasound open platforms are ideal instruments to experiment innovative modalities in transmission and reception. So far, the high number of channels, involved in applications based on 2-D arrays, has been managed through complex combinations of scanners and personal computers, at the expense of ease of use, portability, and real-time performance. This work presents a new flexible architecture, based on the full (hardware and software) synchronization of multiple ULA-OP 256 scanners, in a Master-Slave architecture, and controlled by a single computer. For the hardware synchronization, a Master scanner provides two digital signals (clock and transmission start) to the Slave scanners, while the software synchronization is managed by two purposely developed MATLAB classes that allow the user to interface the scanners as a single system. To demonstrate the effectiveness of the architecture, a 512-channel prototype, composed of two ULA-OP 256 connected to a host PC and to a sparse array, was implemented and tested through applications that demonstrate the high real-time processing power.


  • Experimental study on the association among flow profile shape, systemic and local hemodynamics, wave reflections, based on Vector Doppler imaging

    by Stefano Ricci, Carmela Morizzo, Daniele Mazierli, Piero Tortoli, Michaela Kozakova, Carlo Palombo

    Blood flow velocity profile in large arteries, although commonly assumed parabolic, quite often shows more complex patterns. The aim of this study was to investigate possible correlations between the different flow patterns and their potential determinants like systemic hemodynamic factors as well as local vessel geometry, distensibility and wave reflections. The study focuses on carotid (common, CCA, and internal, ICA) and femoral (common, CFA) arteries in normal subjects. The velocity profiles were obtained through the Multi Line Vector Doppler (MLVD) approach implemented in the ULA-OP 256 scanner, and their shape was quantified through the Bluntness Index (BI), i.e. the ratio between peak and cross-section averaged velocity. Possible correlations among BI and the other systemic and local parameters were investigated. We found that in healthy subjects, plaque free, the profile shape in the CCA is almost parabolic, but it is not in ICA and CFA. Moreover, the profile shape in the carotid is mainly affected by systemic hemodynamic factors, while local factors are more relevant for the profile in CFA.