Experimental study on the association among flow profile shape, systemic and local hemodynamics, wave reflections, based on Vector Doppler imaging
Authors:
- 11 September 2021
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Abstract
Blood flow velocity profile in large arteries, although commonly assumed parabolic, quite often shows more complex patterns. The aim of this study was to investigate possible correlations between the different flow patterns and their potential determinants like systemic hemodynamic factors as well as local vessel geometry, distensibility and wave reflections. The study focuses on carotid (common, CCA, and internal, ICA) and femoral (common, CFA) arteries in normal subjects. The velocity profiles were obtained through the Multi Line Vector Doppler (MLVD) approach implemented in the ULA-OP 256 scanner, and their shape was quantified through the Bluntness Index (BI), i.e. the ratio between peak and cross-section averaged velocity. Possible correlations among BI and the other systemic and local parameters were investigated. We found that in healthy subjects, plaque free, the profile shape in the CCA is almost parabolic, but it is not in ICA and CFA. Moreover, the profile shape in the carotid is mainly affected by systemic hemodynamic factors, while local factors are more relevant for the profile in CFA.Keywords
Funding Information
- CAMP
- Tuscany Regional Government (CUP I58D20000520002)
This publication has 14 references indexed in Scilit:
- Continuous Simultaneous Recording of Brachial Artery Distension and Wall Shear Rate: A New Boost for Flow-Mediated VasodilationIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2018
- Real-Time Blood Velocity Vector Measurement Over a 2-D RegionIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2017
- Wall Shear Rate Measurement: Validation of a New Method Through Multiphysics SimulationsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2016
- ULA-OP 256: A 256-Channel Open Scanner for Development and Real-Time Implementation of New Ultrasound MethodsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2016
- Accurate blood peak velocity estimation using spectral models and vector dopplerIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2015
- Accuracy and Reproducibility of a Novel Dynamic Volume Flow Measurement MethodUltrasound in Medicine & Biology, 2013
- Different role of wave reflection magnitude and timing on left ventricular mass reduction during antihypertensive treatmentJournal Of Hypertension, 2008
- A System for Real-Time Measurement of the Brachial Artery Diameter in B-Mode Ultrasound ImagesIEEE Transactions on Medical Imaging, 2007
- Interaction between secondary velocities, flow pulsation and vessel morphology in the common carotid arteryUltrasound in Medicine & Biology, 2003
- Multiple crossed-beam ultrasound Doppler velocimetryIEEE Transactions on Sonics and Ultrasonics, 1978