Randy F. Espinal Cabarera
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Randy F. Espinal Cabarera has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Collin J. McKinney
Department of Chemistry, University of North Carolina, Chapel Hill, USA
2 shared publications Farhad Shiri
2 shared publications- Pubudu Premarathne2 shared publications
Quentin Jarrell
2 shared publications- Steven Allan Soper
Department of Chemistry, The University of Kansas, Lawrence, KS 66045, USA
2 shared publications Indu A. Chandrasoma
Department of Chemistry The University of Kansas Lawrence KS USA
1 shared publication
Latest Publications
- Open Access
- 10 November 2026
- Published by Elsevier in Biosensors and Bioelectronics
Thin Film Conductors for Single-Molecule, Label-free Detection using Resistive Pulse Sensing
- 10 November 2026
- Published by Elsevier in Biosensors and Bioelectronics
Open AccessThin Film Conductors for Single-Molecule, Label-free Detection using Resistive Pulse Sensing
- Open Access
- 16 September 2026
- Published by Wiley in Small Methods
Peptide Fingerprinting of Single Protein Molecules Using In‐Plane Nanopore Sensors Integrated to an Extended Immobilized Nanoscale Enzymatic Reactor (eINER)
We report a thermoplastic nanofluidic device that combines an extended immobilized nanoscale enzymatic reactor (eINER) with a dual in‐plane nanopore time‐of‐flight (DNP‐ToF) reader for label‐free peptide fingerprinting of single protein molecules. As opposed to traditional membrane‐based nanopores, the DNP‐ToF reader uses two sub‐10 nm pores placed in series and are made from plastic to allow securing the resistive pulse sensing (RPS) independent ToF variable as well as the traditional RPS variables. The device enables on‐chip proteolytic digestion with downstream identification of peptide fragments. Using amyloid‐β (Aβ) as a model system, we demonstrate efficient digestion under nanoscale confinement consistent with a reaction‐limited regime and convection‐dominated transport. The device achieved robust event detection with >95% successful pairing of dual nanopore RPS signals enabling extraction of five key features (ΔI 1 /I 0 , ΔI 2 /I 0 , t D1 , t D2 , and ToF) from individual peptide events. Machine learning provided high‐confidence peptide identification with a random forest (RF) classifier achieving 100% accuracy and a cross‐validated accuracy of 99.6% ± 0.9%. Digestion efficiency was tunable through occupancy‐controlled conditions with RF‐assigned intact Aβ events decreasing from ∼9.5% at 1 nM to ∼0.33% at 100 pM. These results establish a scalable, high‐sensitivity platform for integrated single molecule analysis to secure proteomic data from mass‐limited samples.
- 16 September 2026
- Published by Wiley in Small Methods
Open AccessPeptide Fingerprinting of Single Protein Molecules Using In‐Plane Nanopore Sensors Integrated to an Extended Immobilized Nanoscale Enzymatic Reactor (eINER)
We report a thermoplastic nanofluidic device that combines an extended immobilized nanoscale enzymatic reactor (eINER) with a dual in‐plane nanopore time‐of‐flight (DNP‐ToF) reader for label‐free peptide fingerprinting of single protein molecules. As opposed to traditional membrane‐based nanopores, the DNP‐ToF reader uses two sub‐10 nm pores placed in series and are made from plastic to allow securing the resistive pulse sensing (RPS) independent ToF variable as well as the traditional RPS variables. The device enables on‐chip proteolytic digestion with downstream identification of peptide fragments. Using amyloid‐β (Aβ) as a model system, we demonstrate efficient digestion under nanoscale confinement consistent with a reaction‐limited regime and convection‐dominated transport. The device achieved robust event detection with >95% successful pairing of dual nanopore RPS signals enabling extraction of five key features (ΔI 1 /I 0 , ΔI 2 /I 0 , t D1 , t D2 , and ToF) from individual peptide events. Machine learning provided high‐confidence peptide identification with a random forest (RF) classifier achieving 100% accuracy and a cross‐validated accuracy of 99.6% ± 0.9%. Digestion efficiency was tunable through occupancy‐controlled conditions with RF‐assigned intact Aβ events decreasing from ∼9.5% at 1 nM to ∼0.33% at 100 pM. These results establish a scalable, high‐sensitivity platform for integrated single molecule analysis to secure proteomic data from mass‐limited samples.
- Open Access
- 18 July 2026
- Published by Elsevier in SSRN Electronic Journal
Thin Film Conductors for Single-Molecule, Label-free Detection using Resistive Pulse Sensing
Resistive Pulse Sensing (RPS) provides label-free detection of single molecules. However, conventional RPS systems that rely on macroscopic wire electrodes suffer from mechanical instability and positional drift, which can contribute to large amounts of low-frequency noise. Integrating thin-film electrodes into RPS devices can address these issues, especially when coupled to devices that use thermoplastic substrates due to their ability to be fabricated in a high production mode. However, thin metal films patterned on polymer surfaces are limited by polymer surface energy mismatches and thermal deformation during metallization and bonding. Here, we present a monolithic integration approach for patterning thin film Ag/AgCl electrodes to a hybrid cyclic olefin polymer/copolymer (COP/COC) fluidic nanosensor. Robust interfacial adhesion was achieved utilizing O₂ plasma pretreatment of the plastic and a Titanium (Ti) adhesion layer followed by pulsed DC magnetron sputtering. A thermal fusion bonding protocol mitigated electrode step-height standoff, ensuring efficient sealing without compromising the integrity of the sub-100 nm features patterned via replication into the plastic substrate. Electrochemical characterization confirmed stable, non-polarizable operation for >3 h, while power spectral density analysis demonstrated reduced 1/f noise compared to wire electrodes. During the translocation of a 1200 nt DNA through in-plane nanopores (diameter ~10 nm), the integrated device delivered a 3.3-fold enhancement in the Signal-to-Noise Ratio compared to macro-scale wire electrodes. This performance was driven by a suppressed RMS noise floor and a 2.9-fold increase in fractional blockade amplitude. This work establishes a scalable, high-yield fabrication framework for robust, high-sensitivity solid-state nanopore sensing platforms.
- 18 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThin Film Conductors for Single-Molecule, Label-free Detection using Resistive Pulse Sensing
Resistive Pulse Sensing (RPS) provides label-free detection of single molecules. However, conventional RPS systems that rely on macroscopic wire electrodes suffer from mechanical instability and positional drift, which can contribute to large amounts of low-frequency noise. Integrating thin-film electrodes into RPS devices can address these issues, especially when coupled to devices that use thermoplastic substrates due to their ability to be fabricated in a high production mode. However, thin metal films patterned on polymer surfaces are limited by polymer surface energy mismatches and thermal deformation during metallization and bonding. Here, we present a monolithic integration approach for patterning thin film Ag/AgCl electrodes to a hybrid cyclic olefin polymer/copolymer (COP/COC) fluidic nanosensor. Robust interfacial adhesion was achieved utilizing O₂ plasma pretreatment of the plastic and a Titanium (Ti) adhesion layer followed by pulsed DC magnetron sputtering. A thermal fusion bonding protocol mitigated electrode step-height standoff, ensuring efficient sealing without compromising the integrity of the sub-100 nm features patterned via replication into the plastic substrate. Electrochemical characterization confirmed stable, non-polarizable operation for >3 h, while power spectral density analysis demonstrated reduced 1/f noise compared to wire electrodes. During the translocation of a 1200 nt DNA through in-plane nanopores (diameter ~10 nm), the integrated device delivered a 3.3-fold enhancement in the Signal-to-Noise Ratio compared to macro-scale wire electrodes. This performance was driven by a suppressed RMS noise floor and a 2.9-fold increase in fractional blockade amplitude. This work establishes a scalable, high-yield fabrication framework for robust, high-sensitivity solid-state nanopore sensing platforms.
- 1 April 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 112-115
Comparison of heparin-immobilized vs. antibody-immobilized microspheres for the capture and detection of cytokines during microdialysis sampling
Heparin-immobilized beads were compared against antibody-immobilized beads for improving the collection of targeted cytokines through microdialysis sampling probes. Heparin offers an advantage over antibodies with respect to its stability and cost. The cytokines, MCP-1 and RANTES, exhibited increased flux through the probes when either heparin-immobilized or antibody-immobilized beads were included in the perfusion fluid. This suggests that heparin-immobilized beads may be a viable alternative to antibody-immobilized beads to increase the flux of select cytokines during microdialysis sampling.
- 1 April 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 112-115
Comparison of heparin-immobilized vs. antibody-immobilized microspheres for the capture and detection of cytokines during microdialysis sampling
Heparin-immobilized beads were compared against antibody-immobilized beads for improving the collection of targeted cytokines through microdialysis sampling probes. Heparin offers an advantage over antibodies with respect to its stability and cost. The cytokines, MCP-1 and RANTES, exhibited increased flux through the probes when either heparin-immobilized or antibody-immobilized beads were included in the perfusion fluid. This suggests that heparin-immobilized beads may be a viable alternative to antibody-immobilized beads to increase the flux of select cytokines during microdialysis sampling.