Yu. I. Davydov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Yu. I. Davydov has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
V. Baranov
JINR, Dubna
35 shared publicationsV. Glagolev
30 shared publications- Nikolay Atanov
Joint Institute for Nuclear Research, Dubna, Russia
27 shared publications - Simona Giovannella
Istituto Nazionale di Fisica Nucleare Laboratori Nazionali di Frascati
26 shared publications V. Tereshchenko
Joint Institute for Nuclear Research, Dubna, Russia
23 shared publicationsF. Colao
Laboratori Nazionali di Frascati dell'INFN, Frascati, Italy
22 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , E10001
Erratum: Light outputs of yttrium doped BaF 2 crystals irradiated with neutrons
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , E10001
Open AccessErratum: Light outputs of yttrium doped BaF 2 crystals irradiated with neutrons
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04045
Light outputs of yttrium doped BaF 2 crystals irradiated with gamma
This paper presents a study of gamma irradiation effects on the optical and scintillation properties of pure and yttrium-doped BaF 2 crystals with yttrium concentrations of 1, 3, and 5 mol%. The optical transmittance, light output, and energy resolution of twenty-four 1×1×1 cm 3 samples were measured before and after 60 Co gamma irradiation, with absorbed doses up to 3.56 Mrad. In pure BaF 2 samples, no noticeable degradation in scintillation properties was observed with increasing absorbed dose. In yttrium-doped samples, a deterioration of scintillation properties is observed, with the fast component of crystal luminescence deteriorating more than the slow one. The correlation between the loss of light output and the radiation-induced decrease of optical transmittance, together with the absence of structural changes in Raman spectra, indicates that the degradation of scintillation properties is primarily due to increased self-absorption, rather than to disruption of the scintillation mechanism.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04045
Light outputs of yttrium doped BaF 2 crystals irradiated with gamma
This paper presents a study of gamma irradiation effects on the optical and scintillation properties of pure and yttrium-doped BaF 2 crystals with yttrium concentrations of 1, 3, and 5 mol%. The optical transmittance, light output, and energy resolution of twenty-four 1×1×1 cm 3 samples were measured before and after 60 Co gamma irradiation, with absorbed doses up to 3.56 Mrad. In pure BaF 2 samples, no noticeable degradation in scintillation properties was observed with increasing absorbed dose. In yttrium-doped samples, a deterioration of scintillation properties is observed, with the fast component of crystal luminescence deteriorating more than the slow one. The correlation between the loss of light output and the radiation-induced decrease of optical transmittance, together with the absence of structural changes in Raman spectra, indicates that the degradation of scintillation properties is primarily due to increased self-absorption, rather than to disruption of the scintillation mechanism.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04047
Study of gamma radiation resistance of GaN transistors for signal amplifiers of scintillation electromagnetic calorimeter cells
Based on an unconventional application of commercially available power GaN transistors, a voltage-sensitive amplifier circuit was proposed for a scintillation sandwich-type lead-plastic calorimeter cell using SiPMs, intended for detectors operating under high-radiation conditions. The radiation hardness of the selected GaN transistors under gamma irradiation was investigated. Defect formation in the transistor structures was studied using C-V characteristics. The results demonstrate that GaN transistors can serve as a promising element base for scintillation detectors operating in high-luminosity accelerator environments.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04047
Study of gamma radiation resistance of GaN transistors for signal amplifiers of scintillation electromagnetic calorimeter cells
Based on an unconventional application of commercially available power GaN transistors, a voltage-sensitive amplifier circuit was proposed for a scintillation sandwich-type lead-plastic calorimeter cell using SiPMs, intended for detectors operating under high-radiation conditions. The radiation hardness of the selected GaN transistors under gamma irradiation was investigated. Defect formation in the transistor structures was studied using C-V characteristics. The results demonstrate that GaN transistors can serve as a promising element base for scintillation detectors operating in high-luminosity accelerator environments.
- Open Access
- 1 August 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (08) , P08004
Development, production, and testing of the Mu2e Calorimeter Silicon Photomultipliers
The development and production of the custom Silicon Photomultipliers (SiPMs) for the Mu2e Calorimeter (Mu2e SiPMs) was a complex endeavor, involving meticulous design, procurement, testing, and integration processes. After a thorough analysis of the calorimeter requirements, which translated into detailed technical specifications for the photosensors, a design and pre-production phase was conducted, to evaluate their construction parameters, via an international bidding process with the fabrication contract eventually awarded to Hamamatsu. The production phase, which started in 2018, consisted of manufacturing 3950 Mu2e SiPMs at a rate of 300 units per month, each engineered and quality-controlled to meet the stringent technical requirements. Assembly into the calorimeter disks was completed by December 2023, representing a significant milestone of the Mu2e project. This article offers a comprehensive account of the entire process, from design and procurement to testing and integration.
- 1 August 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (08) , P08004
Open AccessDevelopment, production, and testing of the Mu2e Calorimeter Silicon Photomultipliers
The development and production of the custom Silicon Photomultipliers (SiPMs) for the Mu2e Calorimeter (Mu2e SiPMs) was a complex endeavor, involving meticulous design, procurement, testing, and integration processes. After a thorough analysis of the calorimeter requirements, which translated into detailed technical specifications for the photosensors, a design and pre-production phase was conducted, to evaluate their construction parameters, via an international bidding process with the fabrication contract eventually awarded to Hamamatsu. The production phase, which started in 2018, consisted of manufacturing 3950 Mu2e SiPMs at a rate of 300 units per month, each engineered and quality-controlled to meet the stringent technical requirements. Assembly into the calorimeter disks was completed by December 2023, representing a significant milestone of the Mu2e project. This article offers a comprehensive account of the entire process, from design and procurement to testing and integration.
- Open Access
- 9 October 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1069
The Mu2e crystal and SiPM calorimeter
- 9 October 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1069
Open AccessThe Mu2e crystal and SiPM calorimeter
- 5 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (7) , 1281-1287
The Mu2e Crystal and SiPM Calorimeter: Construction Status
The Mu2e experiment at Fermilab searches for the neutrino-less conversion of a negative muon into an electron, with a distinctive signature of a mono-energetic electron with energy of 104.967 MeV. The calorimeter is made of two disks of pure CsI crystals, each read out by two custom large area UV-extended SiPMs. It plays a fundamental role in providing excellent particle identification capabilities and an online trigger filter while improving the track reconstruction, requiring better than 10% energy and 500 ps timing resolutions for 100 MeV electrons. In this paper, we present the status of construction and the Quality Control (QC) performed on the produced crystals and photosensors, the development of the rad-hard electronics and the most important results of the irradiation tests. Construction of the mechanics is also reported. Status and plans for the calorimeter assembly and its first commissioning are described.
- 5 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (7) , 1281-1287
The Mu2e Crystal and SiPM Calorimeter: Construction Status
The Mu2e experiment at Fermilab searches for the neutrino-less conversion of a negative muon into an electron, with a distinctive signature of a mono-energetic electron with energy of 104.967 MeV. The calorimeter is made of two disks of pure CsI crystals, each read out by two custom large area UV-extended SiPMs. It plays a fundamental role in providing excellent particle identification capabilities and an online trigger filter while improving the track reconstruction, requiring better than 10% energy and 500 ps timing resolutions for 100 MeV electrons. In this paper, we present the status of construction and the Quality Control (QC) performed on the produced crystals and photosensors, the development of the rad-hard electronics and the most important results of the irradiation tests. Construction of the mechanics is also reported. Status and plans for the calorimeter assembly and its first commissioning are described.