Andrew J. Dent
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrew J. Dent has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Gopinathan Sankar
Department of Chemistry, University College London, London WC1H 0AJ, UK
2 shared publications - A. Douglas Winter
Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, United Kingdom
1 shared publication - Andrew James
Physical Sciences Diamond Light Source Diamond House - Harwell Science and Innovation Campus Didcot OxfordshireOX11 0DE United Kingdom
1 shared publication - Andrew Michael Beale
Department of Chemistry, University College London, 20 Gordon Street, WC1H 0AJ, UK
1 shared publication - Armando Pueyos
Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, United Kingdom
1 shared publication - Barry Dobson
Sagentia Ltd, Harston Mill CB22 7GG, England
1 shared publication
Latest Publications
- Open Access
- 22 October 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (6) , 1985-1995
Beamline K11 DIAD: a new instrument for dual imaging and diffraction at Diamond Light Source
The Dual Imaging and Diffraction (DIAD) beamline at Diamond Light Source is a new dual-beam instrument for full-field imaging/tomography and powder diffraction. This instrument provides the user community with the capability to dynamically image 2D and 3D complex structures and perform phase identification and/or strain mapping using micro-diffraction. The aim is to enable in situ and in operando experiments that require spatially correlated results from both techniques, by providing measurements from the same specimen location quasi-simultaneously. Using an unusual optical layout, DIAD has two independent beams originating from one source that operate in the medium energy range (7–38 keV) and are combined at one sample position. Here, either radiography or tomography can be performed using monochromatic or pink beam, with a 1.4 mm × 1.2 mm field of view and a feature resolution of 1.2 µm. Micro-diffraction is possible with a variable beam size between 13 µm × 4 µm and 50 µm × 50 µm. One key functionality of the beamline is image-guided diffraction, a setup in which the micro-diffraction beam can be scanned over the complete area of the imaging field-of-view. This moving beam setup enables the collection of location-specific information about the phase composition and/or strains at any given position within the image/tomography field of view. The dual beam design allows fast switching between imaging and diffraction mode without the need of complicated and time-consuming mode switches. Real-time selection of areas of interest for diffraction measurements as well as the simultaneous collection of both imaging and diffraction data of (irreversible) in situ and in operando experiments are possible.
- 22 October 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (6) , 1985-1995
Open AccessBeamline K11 DIAD: a new instrument for dual imaging and diffraction at Diamond Light Source
The Dual Imaging and Diffraction (DIAD) beamline at Diamond Light Source is a new dual-beam instrument for full-field imaging/tomography and powder diffraction. This instrument provides the user community with the capability to dynamically image 2D and 3D complex structures and perform phase identification and/or strain mapping using micro-diffraction. The aim is to enable in situ and in operando experiments that require spatially correlated results from both techniques, by providing measurements from the same specimen location quasi-simultaneously. Using an unusual optical layout, DIAD has two independent beams originating from one source that operate in the medium energy range (7–38 keV) and are combined at one sample position. Here, either radiography or tomography can be performed using monochromatic or pink beam, with a 1.4 mm × 1.2 mm field of view and a feature resolution of 1.2 µm. Micro-diffraction is possible with a variable beam size between 13 µm × 4 µm and 50 µm × 50 µm. One key functionality of the beamline is image-guided diffraction, a setup in which the micro-diffraction beam can be scanned over the complete area of the imaging field-of-view. This moving beam setup enables the collection of location-specific information about the phase composition and/or strains at any given position within the image/tomography field of view. The dual beam design allows fast switching between imaging and diffraction mode without the need of complicated and time-consuming mode switches. Real-time selection of areas of interest for diffraction measurements as well as the simultaneous collection of both imaging and diffraction data of (irreversible) in situ and in operando experiments are possible.
- Open Access
- 22 September 2021
- Published by IOP Publishing in Journal of Physics: Condensed Matter
- Vol. 33 (48) , 483002
Past, present and future—sample environments for materials research studies in scattering and spectroscopy; a UK perspective
Small angle x-ray scattering and x-ray absorption fine structure are two techniques that have been employed at synchrotron sources ever since their inception. Over the course of the development of the techniques, the introduction of sample environments for added value experiments has grown dramatically. This article reviews past successes, current developments and an exploration of future possibilities for these two x-ray techniques with an emphasis on the developments in the United Kingdom between 1980–2020.
- 22 September 2021
- Published by IOP Publishing in Journal of Physics: Condensed Matter
- Vol. 33 (48) , 483002
Open AccessPast, present and future—sample environments for materials research studies in scattering and spectroscopy; a UK perspective
Small angle x-ray scattering and x-ray absorption fine structure are two techniques that have been employed at synchrotron sources ever since their inception. Over the course of the development of the techniques, the introduction of sample environments for added value experiments has grown dramatically. This article reviews past successes, current developments and an exploration of future possibilities for these two x-ray techniques with an emphasis on the developments in the United Kingdom between 1980–2020.
- Open Access
- 31 May 2021
- Published by IOP Publishing in Journal of Physics: Condensed Matter
- Vol. 33 (26) , 264002
Monitoring the process of formation of ZnO from ZnO2 using in situ combined XRD/XAS technique
Use of in situ combined x-ray diffraction and x-ray absorption spectroscopy for the study of the thermal decomposition of zinc peroxide to zinc oxide is reported here. Comparison of data extracted from both x-ray diffraction (XRD) and x-ray absorption spectroscopy (XAS) with thermo gravimetric analysis (TGA) enabled us to follow the nature of the conversion of ZnO2 to ZnO. A temperature range between 230 °C and 350 °C appears to show that a very poorly crystalline ZnO is formed prior to the formation of an ordered ZnO material. Both the decrease in white line intensity in the Zn K-edge XANES and resulting lower coordination numbers estimated from analysis of the Zn K-edge data of ZnO heated at 500 °C, in comparison to bulk ZnO, suggest that the ZnO produced by this method has significant defects in the system.
- 31 May 2021
- Published by IOP Publishing in Journal of Physics: Condensed Matter
- Vol. 33 (26) , 264002
Open AccessMonitoring the process of formation of ZnO from ZnO2 using in situ combined XRD/XAS technique
Use of in situ combined x-ray diffraction and x-ray absorption spectroscopy for the study of the thermal decomposition of zinc peroxide to zinc oxide is reported here. Comparison of data extracted from both x-ray diffraction (XRD) and x-ray absorption spectroscopy (XAS) with thermo gravimetric analysis (TGA) enabled us to follow the nature of the conversion of ZnO2 to ZnO. A temperature range between 230 °C and 350 °C appears to show that a very poorly crystalline ZnO is formed prior to the formation of an ordered ZnO material. Both the decrease in white line intensity in the Zn K-edge XANES and resulting lower coordination numbers estimated from analysis of the Zn K-edge data of ZnO heated at 500 °C, in comparison to bulk ZnO, suggest that the ZnO produced by this method has significant defects in the system.
- 15 November 2012
- Published by Royal Society of Chemistry (RSC) in Dalton Transactions
- Vol. 42 (6) , 2213-2223
Sc(iii) complexes with neutral N3- and SNS-donor ligands – a spectroscopic study of the activation of ethene polymerisation catalysts
Scandium trichloride complexes with tridentate N3- and S2N-donor ligands (L3) have been synthesised and characterised by IR, 1H, 13C{1H} and 45Sc NMR spectroscopy, microanalysis, and solid state and solution XAFS spectroscopy. Catalytic testing of a subset of these complexes with ethene has been undertaken in chlorobenzene with MMAO-3A and PMAO-IP at 60 °C and 40 bar ethene, giving low activity ethene polymerisation. The reactions of these complexes with MeLi and AlMe3 were studied by 1H, 13C{1H}, 27Al and 45Sc NMR spectroscopy and in situ via Sc K-edge XAFS spectroscopy. Three or four mol. equivalents of MeLi react with [ScCl3(Me3-tacn)] in THF solution to form [ScMe3(Me3-tacn)] cleanly, while complexes of type [ScCl3(R-SNS)] {R-SNS = HN(CH2CH2SC10H21)2} form two different species proposed to be [ScMe3(R-SN(Li)S)] and [ScMe2(R-SN−S)]. In contrast, in situ45Sc NMR and Sc K-edge XAFS spectroscopic studies of the reaction of [ScCl3(Me3-tacn)] with 10 mol. equivalents of AlMe3 strongly suggest that alkylation at the Sc(III) centre does not occur, instead retaining the Cl3N3 coordination environment and most likely forming Sc−Cl−AlMe3 bridging interactions. Similar studies on [ScCl3(decyl-SNS)] with 10 mol. equivalents of AlMe3 are also consistent with this, indicating that alkylation at the Sc centre does not occur except in the presence of co-catalyst [Ph3C][Al{OC(CF3)3}4] and the α-alkene, hex-1-ene.
- 15 November 2012
- Published by Royal Society of Chemistry (RSC) in Dalton Transactions
- Vol. 42 (6) , 2213-2223
Sc(iii) complexes with neutral N3- and SNS-donor ligands – a spectroscopic study of the activation of ethene polymerisation catalysts
Scandium trichloride complexes with tridentate N3- and S2N-donor ligands (L3) have been synthesised and characterised by IR, 1H, 13C{1H} and 45Sc NMR spectroscopy, microanalysis, and solid state and solution XAFS spectroscopy. Catalytic testing of a subset of these complexes with ethene has been undertaken in chlorobenzene with MMAO-3A and PMAO-IP at 60 °C and 40 bar ethene, giving low activity ethene polymerisation. The reactions of these complexes with MeLi and AlMe3 were studied by 1H, 13C{1H}, 27Al and 45Sc NMR spectroscopy and in situ via Sc K-edge XAFS spectroscopy. Three or four mol. equivalents of MeLi react with [ScCl3(Me3-tacn)] in THF solution to form [ScMe3(Me3-tacn)] cleanly, while complexes of type [ScCl3(R-SNS)] {R-SNS = HN(CH2CH2SC10H21)2} form two different species proposed to be [ScMe3(R-SN(Li)S)] and [ScMe2(R-SN−S)]. In contrast, in situ45Sc NMR and Sc K-edge XAFS spectroscopic studies of the reaction of [ScCl3(Me3-tacn)] with 10 mol. equivalents of AlMe3 strongly suggest that alkylation at the Sc(III) centre does not occur, instead retaining the Cl3N3 coordination environment and most likely forming Sc−Cl−AlMe3 bridging interactions. Similar studies on [ScCl3(decyl-SNS)] with 10 mol. equivalents of AlMe3 are also consistent with this, indicating that alkylation at the Sc centre does not occur except in the presence of co-catalyst [Ph3C][Al{OC(CF3)3}4] and the α-alkene, hex-1-ene.
- Open Access
- 1 March 2001
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 8 (2) , 622-624
Effect of Si(IV) substitution on the stability of microporous ZnAPSO-44 solid acid catalysts: a combined XAS/XRD study
The combined XAS/XRD technique has been used to investigate the stability of the microporous structure during calcination process for a series of ZnAPSO-44 materials. Incorporation of large amounts of Zn is found to produce materials that are unstable upon removal of the structure directing organic template molecule. However, simultaneous incorporation of Si is found to increase the thermal stability of the materials, yielding catalysts that are well suited for acid catalysed reactions.
- 1 March 2001
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 8 (2) , 622-624
Open AccessEffect of Si(IV) substitution on the stability of microporous ZnAPSO-44 solid acid catalysts: a combined XAS/XRD study
The combined XAS/XRD technique has been used to investigate the stability of the microporous structure during calcination process for a series of ZnAPSO-44 materials. Incorporation of large amounts of Zn is found to produce materials that are unstable upon removal of the structure directing organic template molecule. However, simultaneous incorporation of Si is found to increase the thermal stability of the materials, yielding catalysts that are well suited for acid catalysed reactions.