Barry Dobson
Barry Dobson has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
A. J. Dent
EPSRC Daresbury Laboratory, Warrington, WA4 4AD, United Kingdom
1 shared publication- Andrew J. Dent
Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, United Kingdom
1 shared publication - Andrew Michael Beale
Department of Chemistry, University College London, 20 Gordon Street, WC1H 0AJ, UK
1 shared publication Andrew. J. Dent
1 shared publicationD. Bogg
EPSRC Daresbury Laboratory, Warrington, WA4 4AD, United Kingdom
1 shared publicationG. Derbyshire
No address, Nocountry
1 shared publication
Latest Publications
- Open Access
- 22 September 2021
- Published by IOP Publishing in Journal of Physics: Condensed Matter
- Vol. 33 (48) , 483002
Past, present and future—sample environments for materials research studies in scattering and spectroscopy; a UK perspective
Small angle x-ray scattering and x-ray absorption fine structure are two techniques that have been employed at synchrotron sources ever since their inception. Over the course of the development of the techniques, the introduction of sample environments for added value experiments has grown dramatically. This article reviews past successes, current developments and an exploration of future possibilities for these two x-ray techniques with an emphasis on the developments in the United Kingdom between 1980–2020.
- 22 September 2021
- Published by IOP Publishing in Journal of Physics: Condensed Matter
- Vol. 33 (48) , 483002
Open AccessPast, present and future—sample environments for materials research studies in scattering and spectroscopy; a UK perspective
Small angle x-ray scattering and x-ray absorption fine structure are two techniques that have been employed at synchrotron sources ever since their inception. Over the course of the development of the techniques, the introduction of sample environments for added value experiments has grown dramatically. This article reviews past successes, current developments and an exploration of future possibilities for these two x-ray techniques with an emphasis on the developments in the United Kingdom between 1980–2020.
- 1 November 2016
- Published by Elsevier in Journal of Non-Crystalline Solids
- Vol. 451, 16-22
Influence of dopant metal ions on the formation of cordierite using combined SAXS/WAXS and EXAFS/WAXS techniques
- 1 November 2016
- Published by Elsevier in Journal of Non-Crystalline Solids
- Vol. 451, 16-22
Influence of dopant metal ions on the formation of cordierite using combined SAXS/WAXS and EXAFS/WAXS techniques
- Open Access
- 1 May 1999
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 6 (3) , 161-163
Conversion of the oldest XAFS station at the first dedicated SR source to a state-of-the-art XAFS facility
- 1 May 1999
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 6 (3) , 161-163
Open AccessConversion of the oldest XAFS station at the first dedicated SR source to a state-of-the-art XAFS facility
- 1 February 1995
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 66 (2) , 2307-2309
X-ray signal processing electronics for solid state detectors
With recent improvements in synchrotron sources and x‐ray optics great pressures have been placed on detector systems to produce higher count rates and better resolutions. Present high performance 13 element germanium detector systems can give reasonable count rates with good resolution (∼104–105 kHz per channel and ∼250 eV FWHM at Fe55 with 0.5 μs shaping time). However, these systems are restricted by limitations in both the detector and in the analog pulse processing after the detector. With respect to the detector, increasing the number of channels without degrading the energy resolution is a great challenge due to increased crosstalk and capacitance. The analog pulse processing electronics are significantly limited by the dead time introduced by the shaping amplifier. This dead time causes pulse pileup at higher rates which leads to nonlinearity and poor resolution. This paper describes the XSPRESS system which has been developed at Daresbury Laboratory for the new Wiggler II beamline 16. This system overcomes previous limits in both signal processing and detector fabrication to give great improvements in system performance. The signal processing electronics departs from standard analog processing techniques and employs sophisticated adaptive digital signal processing hardware to reduce the dead time associated with each event to a minimum. This VME based technology allows us to vastly increase the count rate for each channel yet still retain the ability to gain very good resolution. The detector has been developed through a collaborative agreement with EG&G ORTEC and packs an unprecedented 30 germanium crystals into an extremely small area while still retaining the energy resolution of smaller arrays. This system has increased the throughput rate by an order of magnitude per channel and when all channels are implemented, an increase of at least two orders of magnitude for the whole array should be seen. Data have been taken using this system on the SRS at Daresbury Laboratory and these results will be given along with a detailed explanation of the operation of this system.
- 1 February 1995
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 66 (2) , 2307-2309
X-ray signal processing electronics for solid state detectors
With recent improvements in synchrotron sources and x‐ray optics great pressures have been placed on detector systems to produce higher count rates and better resolutions. Present high performance 13 element germanium detector systems can give reasonable count rates with good resolution (∼104–105 kHz per channel and ∼250 eV FWHM at Fe55 with 0.5 μs shaping time). However, these systems are restricted by limitations in both the detector and in the analog pulse processing after the detector. With respect to the detector, increasing the number of channels without degrading the energy resolution is a great challenge due to increased crosstalk and capacitance. The analog pulse processing electronics are significantly limited by the dead time introduced by the shaping amplifier. This dead time causes pulse pileup at higher rates which leads to nonlinearity and poor resolution. This paper describes the XSPRESS system which has been developed at Daresbury Laboratory for the new Wiggler II beamline 16. This system overcomes previous limits in both signal processing and detector fabrication to give great improvements in system performance. The signal processing electronics departs from standard analog processing techniques and employs sophisticated adaptive digital signal processing hardware to reduce the dead time associated with each event to a minimum. This VME based technology allows us to vastly increase the count rate for each channel yet still retain the ability to gain very good resolution. The detector has been developed through a collaborative agreement with EG&G ORTEC and packs an unprecedented 30 germanium crystals into an extremely small area while still retaining the energy resolution of smaller arrays. This system has increased the throughput rate by an order of magnitude per channel and when all channels are implemented, an increase of at least two orders of magnitude for the whole array should be seen. Data have been taken using this system on the SRS at Daresbury Laboratory and these results will be given along with a detailed explanation of the operation of this system.