WWWawan Aries Widodo

Wawan Aries Widodo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wawan Aries Widodo has a total of 94 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effect of Freestream Vorticity Structure on Different Planform Wing Airfoil NASA SC(2)-0612

    by S.P. Setyo Hariyadi, Ahmad Bahrawi, Bambang Driyono, Dwiyanto Dwiyanto, Sutardi Sutardi, Wawan Aries Widodo

    The movement of fluid flow from the leading edge to the trailing edge is an interesting phenomenon to observe, especially on commercial aircraft wings. This condition becomes very different when the fluid flow crosses different wing planforms even though they have the same airfoil type. This study provides an alternative design for the wing planform of the Embraer ERJ 145 aircraft using the NASA SC(2)-0612 airfoil, resulting in improved aerodynamic performance. The numerical simulation uses a Reynolds number of Re = 2.88 × 10⁷, corresponding to the cruising speed conditions of the Embraer ERJ 145. Rectangular, delta, and swept-back wings were used as research configurations, particularly for the velocity magnitude, turbulent intensity, turbulent viscosity ratio, and turbulent kinetic energy components. The lateral flow from the wing root toward the wingtip, which is an effect of the wing planform, creates a vorticity structure flow pattern. The fluid flow on the rectangular wing, dominated by the mainflow from the leading edge to the trailing edge, does not significantly affect the flow properties around the wingtip. Conversely, the delta and swept-back wings significantly influence the turbulent intensity, turbulent viscosity ratio, and turbulent kinetic energy at the wingtip, which are highly influenced by the wing planform shape.

  • Numerical Investigation of Drag Characteristics on Wing Planform NASA 20612

    by Setyo Hariyadi Suranto Putro, Bambang Junipitoyo, Sutardi, Wawan Aries Widodo

  • Open Access

    Numerical Analysis of Extra Inlet Integration in Close House Cages under Single and Multiple Exhaust Fan Operations

    by Zain Lillahulhaq, Wawan Aries Widodo, Sutardi Sutardi, Shella Arinda

    This study investigates the impact of additional air inlets—specifically slot and ceiling inlets—on airflow distribution, microclimate conditions, and waste gas accumulation in a negative pressure close house cage. Poor ventilation in such systems often leads to heat stress, increased mortality, and the buildup of CO2 and NH3. Increasing the supply of fresh air is essential to enhance thermal comfort and maintain a healthy indoor environment. A three-dimensional CFD model was developed using the k-ω SST turbulence model, incorporating heat transfer, buoyancy effects, and porous media for both the evaporative cooling pad (ECP) and poultry. Simulations were conducted under single and multiple exhaust fan operations, using four variations of extra-inlet placements. The effects of each configuration were evaluated in terms of airflow velocity, temperature, relative humidity (RH), and gas concentration across 42 iso-surfaces along the cage’s longitudinal axis. The results showed that additional inlets reduced CO₂ and NH₃ accumulation, especially under multiple exhaust fan operation. However, these setups also introduced warmer and drier air due to unconditioned inflow, reducing airflow uniformity. Slot positions near sidewalls lowered RH and increased thermal discomfort. Despite improved gas removal, the configuration without extra inlets offered better environmental stability and thermal uniformity.


  • Open Access

    Ventilation Strategies to Control Aerosol Transmission in Classroom: A Numerical Study

    by Luthfi Hakim, Wawan Aries Widodo, Sutardi Sutardi, Priyo Heru Adiwibowo, Thearith Yone

    This study is a predicted numerical analysis that uses Computational Fluid Dynamics (CFD) to assess how well five different ventilation scenarios manage the spread of aerosols in classrooms. Three-dimensional transient simulations were conducted for 210 s using a U-RANS approach with an RNG k-epsilon turbulence model. To improve the accuracy of modelling airflow and particle trajectories, a Discrete Phase Model (DPM) Multicomponent Eulerian-Lagrangian model was used. Quantitative validation demonstrated a relative error of 1.08% compared to the Duguid experimental data, indicating a high level of accuracy for the numerical model. Numerical simulation results showed that the scenario with an OAR of 1.16% resulted in the least number of trapped aerosol particles, 101 out of a total of 4600 particles (1.2%). These findings demonstrate the potential for reducing the risk of spreading virus-carrying aerosols in enclosed spaces by optimizing ventilation configurations. This study presents an integrated approach that has not been explored in many previous studies, specifically the dynamic integration of multiphase models to evaluate ventilation techniques' efficacy. Recommendations from the results can be used as a predictive basis in the design of safer and more comfortable ventilation systems in school environments.


  • Open Access

    Numerical simulation of co-firing oil palm fronds and lignite coal injected at different burning rates in tangential pulverized coal burner

    by Sobar Ihsan, Prabowo Prabowo, Wawan Aries Widodo, I Nyoman Agus Adi Saputra

    Reducing CO₂ emissions and utilizing biomass, particularly palm oil mill waste, is crucial for addressing climate change, enhancing air quality, and advancing environmentally sustainable clean technology innovations. Palm fronds can serve as a renewable fuel source with minimal emissions, providing a viable co-firing option for coal in coal-fired power plants (PLTU). Although previous studies have shown promising CO₂ emission reductions through co-combustion of oil palm fronds and coal, there is still no comprehensive analysis of the combustion characteristics and emission behavior when varying the burner injection zone, thus further research is required. This study performs a numerical analysis using three-dimensional computational-fluid dynamics (CFD) to examine the co-burning process of palm fronds alongside low-calorie coal (LRC) at the Pacitan PLTU, which has a capacity of 315 megawatts. The co-burning simulation, incorporating a 5% substitution of palm fronds in each burner, was conducted to differentiate between burners A and D, aiming to determine the optimum injection area. The findings of the simulation reveal inconsistencies in combustion properties, particularly regarding temperature allocation. The primary results demonstrate a temperature rise when palm fronds are used as a co-firing fuel, attributed to their greater volatility and oxygen content compared to coal. The most notable decrease in CO₂ emissions was observed with the substitution of 5% oil palm fronds in burner B; however, the reduction was not substantial, as indicated by a mass fraction value of 0.128 at the boiler discharge. An increase in NOx mass fraction was also observed due to the organic nitrogen in palm frond biomass, which decomposes rapidly during combustion at high temperatures. This co-firing technology is expected to provide a means for lowering emissions and improving the use of alternative fuels as a substitution for fossil fuels in a time to come.


  • Open Access

    Utilization of Palm Frond Waste as Fuel for Co-Firing Coal and Biomass in a Tangentially Pulverized Coal Boiler Using Computational Fluid Dynamic Analysis

    by Sobar Ihsan, Prabowo, Wawan Aries Widodo, I Nyoman Agus Adi Saputra, Hariana

    Renewable energy sources are becoming increasingly crucial in the global energy industry and are acknowledged as a significant substitute for fossil fuels. Oil palm fronds are a type of biomass fuel that can be utilized as a substitute for fossil fuels in the combustion process of boilers. Co-firing (HT-FRD) is a beneficial technology for reducing exhaust gas emissions generated by coal-burning power stations. By utilizing computational fluid dynamics (CFD), this study has modeled and evaluated co-firing palm frond residue (HT-FRD) with hydrothermal treatment into a 315 MWe boiler. In the simulation, six different HT-FRD co-firing ratios, 0%, 5%, 15%, 25%, 35%, and 50%, were used to demonstrate the differences in combustion characteristics and emissions in the combustion chamber. The data indicate that HT-FRD co-firing can enhance temperature distribution, velocity, and unburned particles. All in all, co-firing conditions with 5–15% HT-FRD ratios appear to have the most favorable combustion temperature, velocity, and exhaust gas characteristics.


  • Open Access

    An Analysis of Air Conditioning System Operation Patterns on Droplet Particle Distribution in a Classroom-A CFD Approach

    by Luthfi Hakim, Wawan Aries Widodo, Bambang Arip Dwiyantoro, Sutardi, Anton Nugroho, Zain Lillahulhaq

    In the classroom context, the transmission of pathogens among students is a significant concern. Therefore, it is important to determine appropriate airflow patterns, the placement of supply and exhaust ventilation, and the optimization of classroom design to reduce the risk of pathogen transmission. This research aims to determine the performance of two air conditioning (AC) operating patterns—low speed and high speed—in six scenarios involving window and door configurations and identify the most effective strategies for minimizing virus exposure to occupants in classrooms. The method used in this research is numerical simulation with the 3D unsteady k-ε RNG model to simulate air flow and the Eulerian-Lagrange approach to capture the movement of SARS-CoV-2 aerosol droplets. The results of this research show that of the six scenarios determined by the researchers, the low-speed AC operating pattern with an incoming air speed of 3.5 m/s occurs in scenario 5, that is, all windows open and doors closed. This is based on the lowest number of students exposed to the virus, which is 22.22%. Meanwhile, the high-speed AC operating pattern with an incoming air speed of 6 m/s occurs in scenario 2, that is, all windows closed and doors open. This is based on the lowest number of students exposed to the virus, which is 22.22%, so it can be concluded that increasing the air flow speed originating from the AC will speed up the droplets to leave the room through the outlet. Meanwhile, increasing the outlet capacity will shorten the particle path, thereby shortening the time when the droplets are in the classroom.