Yan Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yan Chen has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Jiejian Zhang
School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001, People’s Republic of China
2 shared publications- Xiaoliang Guo
College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, China
2 shared publications - Daihua Zhang
State Key Laboratory of Precision Measurement Technology and Instruments, School of Precision Instruments and Opto-electronics Engineering , Tianjin University , No. 92 Weijin Road , Tianjin 300072 , China
1 shared publication - Hao Zhang
State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
1 shared publication Honglan Jiang
Tsinghua University, Beijing, Beijing, China
1 shared publication- Qiang Sun
China-Japan Friendship Hospital Stomatology Center, No.2 Sakura East Street, Chaoyang District, Beijing 100029, China
1 shared publication
Latest Publications
- Open Access
- 20 September 2026
- Published by Fuji Technology Press Ltd. in Journal of Advanced Computational Intelligence and Intelligent Informatics
- Vol. 30 (5) , 1335-1343
MRI Image Segmentation Algorithm for Temporomandibular Joint Discs and Condyles Based on the Improved nnU-Net Framework
Accurate segmentation of the articular disc from MRI is crucial for diagnosing and treating temporomandibular joint disorders (TMD), but it remains challenging because of the small structure size, blurred boundaries, and class imbalance. This study aims to improve articular disc segmentation accuracy for computer-aided TMD diagnosis. We propose an enhanced nnU-Net-based method with three modifications: (1) fewer downsampling layers to preserve spatial detail, (2) a DynFocus module with channel-and-spatial attention at the bottleneck to enhance disc-background discrimination, and (3) a joint loss combining Dice focal and boundary losses to improve sensitivity and boundary delineation. On 50 temporomandibular joint MRI cases, the proposed method improved disc segmentation Dice from 0.69 to 0.71, maintained condyle Dice at 0.89, and achieved an average Dice of 0.80. These results indicate that the proposed enhancements improve disc segmentation performance while preserving condyle segmentation accuracy, supporting their usefulness for MRI-based TMD assessment.
- 20 September 2026
- Published by Fuji Technology Press Ltd. in Journal of Advanced Computational Intelligence and Intelligent Informatics
- Vol. 30 (5) , 1335-1343
Open AccessMRI Image Segmentation Algorithm for Temporomandibular Joint Discs and Condyles Based on the Improved nnU-Net Framework
Accurate segmentation of the articular disc from MRI is crucial for diagnosing and treating temporomandibular joint disorders (TMD), but it remains challenging because of the small structure size, blurred boundaries, and class imbalance. This study aims to improve articular disc segmentation accuracy for computer-aided TMD diagnosis. We propose an enhanced nnU-Net-based method with three modifications: (1) fewer downsampling layers to preserve spatial detail, (2) a DynFocus module with channel-and-spatial attention at the bottleneck to enhance disc-background discrimination, and (3) a joint loss combining Dice focal and boundary losses to improve sensitivity and boundary delineation. On 50 temporomandibular joint MRI cases, the proposed method improved disc segmentation Dice from 0.69 to 0.71, maintained condyle Dice at 0.89, and achieved an average Dice of 0.80. These results indicate that the proposed enhancements improve disc segmentation performance while preserving condyle segmentation accuracy, supporting their usefulness for MRI-based TMD assessment.
- 1 April 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (4) , 047523
An Online Fully-Automatic High Precision Monitoring System of Steam Dryness Based on Spectral Absorption Characteristics
Steam dryness detection is crucial in the field of oil exploitation. A steam dryness too high will be dangerous, whereas a low steam dryness too low will affect the efficiency of extraction. Therefore, real-time, high-precision detection of steam dryness is essential. The methods for detecting steam dryness include chemical, thermodynamic, radiometric, and microwave. The manual test method possesses the best detection accuracy. However, the real-time performance is not good, and the detection process is cumbersome. This article uses a silver nitrate solution to titrate chloride ions and combine them with the change in the absorbance of the solution to determine the endpoint of the titration. This article reported that the automatic chloride ion concentration measurement was a rep and that the detection of chloride ion concentration was 15 mg l −1 . The detection linearity reached 0.992. Therefore, our titration endpoint judgment method has better anti-interference.
- 1 April 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (4) , 047523
An Online Fully-Automatic High Precision Monitoring System of Steam Dryness Based on Spectral Absorption Characteristics
Steam dryness detection is crucial in the field of oil exploitation. A steam dryness too high will be dangerous, whereas a low steam dryness too low will affect the efficiency of extraction. Therefore, real-time, high-precision detection of steam dryness is essential. The methods for detecting steam dryness include chemical, thermodynamic, radiometric, and microwave. The manual test method possesses the best detection accuracy. However, the real-time performance is not good, and the detection process is cumbersome. This article uses a silver nitrate solution to titrate chloride ions and combine them with the change in the absorbance of the solution to determine the endpoint of the titration. This article reported that the automatic chloride ion concentration measurement was a rep and that the detection of chloride ion concentration was 15 mg l −1 . The detection linearity reached 0.992. Therefore, our titration endpoint judgment method has better anti-interference.
- Open Access
- 13 October 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (10) , 1238
A Sensitivity-Enhanced Electrolyte-Gated Graphene Field-Effect Transistor Biosensor by Acoustic Tweezers
Low-abundance biomolecule detection is very crucial in many biological and medical applications. In this paper, we present a novel electrolyte-gated graphene field-effect transistor (EGFET) biosensor consisting of acoustic tweezers to increase the sensitivity. The acoustic tweezers are based on a high-frequency bulk acoustic resonator with thousands of MHz, which has excellent ability to concentrate nanoparticles. The operating principle of the acoustic tweezers to concentrate biomolecules is analyzed and verified by experiments. After the actuation of acoustic tweezers for 10 min, the IgG molecules are accumulated onto the graphene. The sensitivities of the EGFET biosensor with accumulation and without accumulation are compared. As a result, the sensitivity of the graphene-based biosensor is remarkably increased using SMR as the biomolecule concentrator. Since the device has advantages such as miniaturized size, low reagent consumption, high sensitivity, and rapid detection, we expect it to be readily applied to many biological and medical applications.
- 13 October 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (10) , 1238
Open AccessA Sensitivity-Enhanced Electrolyte-Gated Graphene Field-Effect Transistor Biosensor by Acoustic Tweezers
Low-abundance biomolecule detection is very crucial in many biological and medical applications. In this paper, we present a novel electrolyte-gated graphene field-effect transistor (EGFET) biosensor consisting of acoustic tweezers to increase the sensitivity. The acoustic tweezers are based on a high-frequency bulk acoustic resonator with thousands of MHz, which has excellent ability to concentrate nanoparticles. The operating principle of the acoustic tweezers to concentrate biomolecules is analyzed and verified by experiments. After the actuation of acoustic tweezers for 10 min, the IgG molecules are accumulated onto the graphene. The sensitivities of the EGFET biosensor with accumulation and without accumulation are compared. As a result, the sensitivity of the graphene-based biosensor is remarkably increased using SMR as the biomolecule concentrator. Since the device has advantages such as miniaturized size, low reagent consumption, high sensitivity, and rapid detection, we expect it to be readily applied to many biological and medical applications.
- 1 June 2021
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 168 (6) , 067524
Real-Time Continuous Rapid Colorimetric Sensor for Gaseous Formaldehyde Determination by Increasing Gas-Liquid Reaction Rate
Formaldehyde can have detrimental health effects on humans. To reduce exposure to formaldehyde, several methods have been reported for gas-phase formaldehyde determination including chromatography, capillary electrophoresis electrochemical and so on. Among these methods, colorimetric sensor is a promising technique for its high sensitivity, selectivity, low cost and compactness. However, it usually takes tens of minutes for one measurement. In this paper, a real-time continuous rapid formaldehyde determination system based on colorimetric sensor was presented. Through the study of the relationship between inlet diameter of gas and its bubble size and reaction speed, the reaction time is reduced to 1/3 with an ability to detect formaldehyde concentrations as low as 0.02 ppm. The system can also measure the formaldehyde concentration continuously and automatically, which is vital for locating pollution sources.
- 1 June 2021
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 168 (6) , 067524
Real-Time Continuous Rapid Colorimetric Sensor for Gaseous Formaldehyde Determination by Increasing Gas-Liquid Reaction Rate
Formaldehyde can have detrimental health effects on humans. To reduce exposure to formaldehyde, several methods have been reported for gas-phase formaldehyde determination including chromatography, capillary electrophoresis electrochemical and so on. Among these methods, colorimetric sensor is a promising technique for its high sensitivity, selectivity, low cost and compactness. However, it usually takes tens of minutes for one measurement. In this paper, a real-time continuous rapid formaldehyde determination system based on colorimetric sensor was presented. Through the study of the relationship between inlet diameter of gas and its bubble size and reaction speed, the reaction time is reduced to 1/3 with an ability to detect formaldehyde concentrations as low as 0.02 ppm. The system can also measure the formaldehyde concentration continuously and automatically, which is vital for locating pollution sources.