G. Presta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
G. Presta has a total of 169 co-authors. Here are the top co-authors by number of shared publications:
- Francesco Piacentini
Dipartimento di Fisica, Sapienza Universit di Roma, Roma, Italy
10 shared publications - Fabio Columbro
Sapienza University of Rome
9 shared publications - Alessandro Paiella
Sapienza University of Rome
7 shared publications - Giorgio Pettinari
Institute for Photonics and Nanotechnologies (CNR‐IFN) National Research Council Rome 00133 Italy
7 shared publications P. de Bernardis
Univ. Roma Sapienza, Rome, Italy
7 shared publicationsA. Coppolecchia
Univ. Roma Sapienza, Rome, Italy
6 shared publications
Latest Publications
- Open Access
- 1 May 2020
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1548 (1)
The first flight of the OLIMPO experiment: instrument performance
OLIMPO is a balloon-borne experiment aiming at spectroscopic measurements of the Sunyaev-Zel’dovich effect in clusters of galaxies. The instrument operates from the stratosphere, so that it can cover a wide frequency range (from ∼ 130 to ∼ 520 GHz in 4 bands), including frequencies which are not observable with ground-based instruments. OLIMPO is composed of a 2.6-m aperture telescope, a differential Fourier transform spectrometer and four arrays of lumped element kinetic inductance detectors operating at the temperature of 0.3 K. The payload was launched from the Longyearbyen airport (Svalbard Islands) on July 14th, 2018, and operated for 5 days, at an altitude of 38 km around the North Pole. We report the in-flight performance of the first lumped element kinetic inductance detector arrays ever flown onboard a stratospheric balloon.
- 1 May 2020
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1548 (1)
Open AccessThe first flight of the OLIMPO experiment: instrument performance
OLIMPO is a balloon-borne experiment aiming at spectroscopic measurements of the Sunyaev-Zel’dovich effect in clusters of galaxies. The instrument operates from the stratosphere, so that it can cover a wide frequency range (from ∼ 130 to ∼ 520 GHz in 4 bands), including frequencies which are not observable with ground-based instruments. OLIMPO is composed of a 2.6-m aperture telescope, a differential Fourier transform spectrometer and four arrays of lumped element kinetic inductance detectors operating at the temperature of 0.3 K. The payload was launched from the Longyearbyen airport (Svalbard Islands) on July 14th, 2018, and operated for 5 days, at an altitude of 38 km around the North Pole. We report the in-flight performance of the first lumped element kinetic inductance detector arrays ever flown onboard a stratospheric balloon.
- 17 April 2020
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 200 (5-6) , 374-383
Progress Report on the Large-Scale Polarization Explorer
- 17 April 2020
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 200 (5-6) , 374-383
Progress Report on the Large-Scale Polarization Explorer
- 24 February 2020
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 312-319
SWIPE Multi-mode Pixel Assembly Design and Beam Pattern Measurements at Cryogenic Temperature
- 24 February 2020
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 312-319
SWIPE Multi-mode Pixel Assembly Design and Beam Pattern Measurements at Cryogenic Temperature
- 10 February 2020
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 491-501
In-Flight Performance of the LEKIDs of the OLIMPO Experiment
- 10 February 2020
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 491-501
In-Flight Performance of the LEKIDs of the OLIMPO Experiment
- 9 December 2019
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 130-137
W-band Lumped Element Kinetic Inductance Detector Array for Large Ground-Based Telescopes
- 9 December 2019
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 130-137
W-band Lumped Element Kinetic Inductance Detector Array for Large Ground-Based Telescopes
- 1 July 2019
- Published by IOP Publishing in Journal of Cosmology and Astroparticle Physics
- Vol. 2019 (07) , 003
Kinetic Inductance Detectors for the OLIMPO experiment: in-flight operation and performance
- 1 July 2019
- Published by IOP Publishing in Journal of Cosmology and Astroparticle Physics
- Vol. 2019 (07) , 003
Kinetic Inductance Detectors for the OLIMPO experiment: in-flight operation and performance
- Open Access
- 1 February 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1182 (1) , 012005
Kinetic Inductance Detectors and readout electronics for the OLIMPO experiment
Kinetic Inductance Detectors (KIDs) are superconductive low–temperature detectors useful for astrophysics and particle physics. We have developed arrays of lumped elements KIDs (LEKIDs) sensitive to microwave photons, optimized for the four horn–coupled focal planes of the OLIMPO balloon–borne telescope, working in the spectral bands centered at 150 GHz, 250 GHz, 350 GHz, and 460 GHz. This is aimed at measuring the spectrum of the Sunyaev–Zel’dovich effect for a number of galaxy clusters, and will validate LEKIDs technology in a space–like environment. Our detectors are optimized for an intermediate background level, due to the presence of residual atmosphere and room–temperature optical system and they operate at a temperature of 0.3 K. The LEKID planar superconducting circuits are designed to resonate between 100 and 600 MHz, and to match the impedance of the feeding waveguides; the measured quality factors of the resonators are in the 104 – 105 range, and they have been tuned to obtain the needed dynamic range. The readout electronics is composed of a cold part, which includes a low noise amplifier, a dc–block, coaxial cables, and power attenuators; and a room–temperature part, FPGA–based, including up and down-conversion microwave components (IQ modulator, IQ demodulator, amplifiers, bias tees, attenuators). In this contribution, we describe the optimization, fabrication, characterization and validation of the OLIMPO detector system.
- 1 February 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1182 (1) , 012005
Open AccessKinetic Inductance Detectors and readout electronics for the OLIMPO experiment
Kinetic Inductance Detectors (KIDs) are superconductive low–temperature detectors useful for astrophysics and particle physics. We have developed arrays of lumped elements KIDs (LEKIDs) sensitive to microwave photons, optimized for the four horn–coupled focal planes of the OLIMPO balloon–borne telescope, working in the spectral bands centered at 150 GHz, 250 GHz, 350 GHz, and 460 GHz. This is aimed at measuring the spectrum of the Sunyaev–Zel’dovich effect for a number of galaxy clusters, and will validate LEKIDs technology in a space–like environment. Our detectors are optimized for an intermediate background level, due to the presence of residual atmosphere and room–temperature optical system and they operate at a temperature of 0.3 K. The LEKID planar superconducting circuits are designed to resonate between 100 and 600 MHz, and to match the impedance of the feeding waveguides; the measured quality factors of the resonators are in the 104 – 105 range, and they have been tuned to obtain the needed dynamic range. The readout electronics is composed of a cold part, which includes a low noise amplifier, a dc–block, coaxial cables, and power attenuators; and a room–temperature part, FPGA–based, including up and down-conversion microwave components (IQ modulator, IQ demodulator, amplifiers, bias tees, attenuators). In this contribution, we describe the optimization, fabrication, characterization and validation of the OLIMPO detector system.
- 1 February 2019
- Published by IOP Publishing in Journal of Cosmology and Astroparticle Physics
- Vol. 2019 (02) , E01
Erratum: Kinetic inductance detectors for the OLIMPO experiment: design and pre-flight characterization
Please see the PDF file for details.
- 1 February 2019
- Published by IOP Publishing in Journal of Cosmology and Astroparticle Physics
- Vol. 2019 (02) , E01
Erratum: Kinetic inductance detectors for the OLIMPO experiment: design and pre-flight characterization
Please see the PDF file for details.
- Open Access
- 1 January 2019
- Published by Wiley in Astronomische Nachrichten
- Vol. 340 (1-3) , 83-88
The short wavelength instrument for the polarization explorer balloon‐borne experiment: Polarization modulation issues
- 1 January 2019
- Published by Wiley in Astronomische Nachrichten
- Vol. 340 (1-3) , 83-88
Open AccessThe short wavelength instrument for the polarization explorer balloon‐borne experiment: Polarization modulation issues
- 1 January 2019
- Published by IOP Publishing in Journal of Cosmology and Astroparticle Physics
- Vol. 2019 (01) , 039
Kinetic inductance detectors for the OLIMPO experiment: design and pre-flight characterization
We designed, fabricated, and characterized four arrays of horn-coupled, lumped element kinetic inductance detectors (LEKIDs), optimized to work in the spectral bands of the balloon-borne OLIMPO experiment. OLIMPO is a 2.6 m aperture telescope, aimed at spectroscopic measurements of the Sunyaev-Zel'dovich (SZ) effect. OLIMPO will also validate the LEKID technology in a representative space environment. The corrected focal plane is filled with diffraction limited horn-coupled KID arrays, with 19, 37, 23, 41 active pixels respectively at 150, 250, 350, and 460 GHz. Here we report on the full electrical and optical characterization performed on these detector arrays before the flight. In a dark laboratory cryostat, we measured the resonator electrical parameters, such as the quality factors and the electrical responsivities, at a base temperature of 300 mK. The measured average resonator Qs are 1.7× 104, 7.0× 103, 1.0× 104, and 1.0× 104 for the 150, 250, 350, and 460 GHz arrays, respectively. The average electrical phase responsivities on resonance are 1.4 rad/pW, 1.5 rad/pW, 2.1 rad/pW, and 2.1 rad/pW; the electrical noise equivalent powers are 45 aW/√Hz, 160 aW/√Hz, 80 aW/√Hz, and 140 aW/√Hz, at 12 Hz. In the OLIMPO cryostat, we measured the optical properties, such as the noise equivalent temperatures (NET) and the spectral responses. The measured NETRJs are 200 μ K.√s, 240 μK √s, 240 μK √s, and 340 μK √s, at 12 Hz; under 78, 88, 92, and 90 mK Rayleigh-Jeans blackbody load changes respectively for the 150, 250, 350, and 460 GHz arrays. The spectral responses were characterized with the OLIMPO differential Fourier transform spectrometer (DFTS) up to THz frequencies, with a resolution of 1.8 GHz.
- 1 January 2019
- Published by IOP Publishing in Journal of Cosmology and Astroparticle Physics
- Vol. 2019 (01) , 039
Kinetic inductance detectors for the OLIMPO experiment: design and pre-flight characterization
We designed, fabricated, and characterized four arrays of horn-coupled, lumped element kinetic inductance detectors (LEKIDs), optimized to work in the spectral bands of the balloon-borne OLIMPO experiment. OLIMPO is a 2.6 m aperture telescope, aimed at spectroscopic measurements of the Sunyaev-Zel'dovich (SZ) effect. OLIMPO will also validate the LEKID technology in a representative space environment. The corrected focal plane is filled with diffraction limited horn-coupled KID arrays, with 19, 37, 23, 41 active pixels respectively at 150, 250, 350, and 460 GHz. Here we report on the full electrical and optical characterization performed on these detector arrays before the flight. In a dark laboratory cryostat, we measured the resonator electrical parameters, such as the quality factors and the electrical responsivities, at a base temperature of 300 mK. The measured average resonator Qs are 1.7× 104, 7.0× 103, 1.0× 104, and 1.0× 104 for the 150, 250, 350, and 460 GHz arrays, respectively. The average electrical phase responsivities on resonance are 1.4 rad/pW, 1.5 rad/pW, 2.1 rad/pW, and 2.1 rad/pW; the electrical noise equivalent powers are 45 aW/√Hz, 160 aW/√Hz, 80 aW/√Hz, and 140 aW/√Hz, at 12 Hz. In the OLIMPO cryostat, we measured the optical properties, such as the noise equivalent temperatures (NET) and the spectral responses. The measured NETRJs are 200 μ K.√s, 240 μK √s, 240 μK √s, and 340 μK √s, at 12 Hz; under 78, 88, 92, and 90 mK Rayleigh-Jeans blackbody load changes respectively for the 150, 250, 350, and 460 GHz arrays. The spectral responses were characterized with the OLIMPO differential Fourier transform spectrometer (DFTS) up to THz frequencies, with a resolution of 1.8 GHz.