LZLang Zhao

Lang Zhao

*This is an algorithmically generated author record based on publicly available information.

Lang Zhao has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Two-Stage Locating and Capacity Optimization Model for the Ultra-High-Voltage DC Receiving End Considering Carbon Emission Trading and Renewable Energy Time-Series Output Reconstruction

    by Lang Zhao, Zhidong Wang, Hao Sheng, Yizheng Li, Tianqi Zhang, Yao Wang, Haifeng Yu

    With the load center’s continuous expansion and development of the AC power grid’s scale and construction, the recipient grid under the multi-feed DC environment is facing severe challenges of DC commutation failure and bipolar blocking due to the high strength of AC-DC coupling and the low level of system inertia, which brings many complexities and uncertainties to economic scheduling. In addition, the large-scale grid integration of wind power, photovoltaic, and other intermittent energy sources makes the ultra-high-voltage (UHV) DC channel operation state randomized. The deterministic scenario-based timing power simulation is no longer suitable for the current complex and changeable grid operation state. In this paper, we first start with the description and analysis of the uncertainty in renewable energy (RE) sources, such as wind and solar, and reconstruct the time-sequence power model by using the stochastic differential equation model. Then, a carbon emission trading cost (CET) model is constructed based on the CET mechanism, and the two-stage locating and capacity optimization model for the UHV DC receiving end is proposed under the constraint of dispatch safety and stability. Among them, the first stage starts with the objective of maximizing the carrying capacity of the UHV DC receiving end grid; the second stage checks its dynamic safety under the basic and fault modes according to the results of the first stage and corrects the drop point and capacity of the UHV DC line with the objective of achieving safe and stable UHV DC operation at the lowest economic investment. In addition, the two-stage model innovatively proposes UHV DC relative inertia constraints, peak adjustment margin constraints, transient voltage support constraints under commutation failure conditions, and frequency support constraints under a DC blocking state. In addition, to address the problem that the probabilistic constraints of the scheduling model are difficult to solve, the discrete step-size transformation and convolution sequence operation methods are proposed to transform the chance-constrained planning into mixed-integer linear planning for solving. Finally, the proposed model is validated with a UHV DC channel in 2023, and the results confirm the feasibility and effectiveness of the model.

  • Open Access

    Optimal Configuration Model for Large Capacity Synchronous Condenser Considering Transient Voltage Stability in Multiple UHV DC Receiving End Grids

    by Lang Zhao, Zhidong Wang, Hao Sheng, Yizheng Li, Xueying Wang, Yao Wang, Haifeng Yu

    In a multi-fed DC environment, the UHV DC recipient grid faces significant challenges related to DC phase shift failure and voltage instability due to the high AC/DC coupling strength and low system inertia level. While the new large-capacity synchronous condensers (SCs) can provide effective transient reactive power support, the associated investment and operation costs are high. Therefore, it is valuable to investigate the optimization of SC configuration at key nodes in the recipient grid in a scientific and rational manner. This study begins by qualitatively and quantitatively analyzing the dynamic characteristics of DC reactive power and induction motors under AC faults. The sub-transient and transient reactive power output model is established to describe the SC output characteristics, elucidating the coupling relationship between the SC’s reactive power output and the DC reactive power demand at different time scales. Subsequently, a critical stabilized voltage index for dynamic loads is defined, and the SC’s reactive power compensation target is quantitatively calculated across different time scales, revealing the impact of transient changes in DC reactive power on the transient voltage stability of the multi-fed DC environment with dynamic load integration. Finally, an optimal configuration model for the large-capacity SC is proposed under the critical stability constraint of dynamic loads to maximize the SC’s reactive power support capability at the lowest economic cost. The proposed model is validated in a multi-fed DC area, demonstrating that the optimal configuration scheme effectively addresses issues related to DC phase shift failures and voltage instability resulting from AC bus voltage drops.


  • Open Access

    Two-Stage Optimal Configuration Strategy of Distributed Synchronous Condensers at the Sending End of Large-Scale Wind Power Generation Bases

    by Lang Zhao, Zhidong Wang, Yizheng Li, Xueying Wang, Zhiyun Hu, Yunpeng Xiao

    The transmission end of large-scale wind power generation bases faces challenges such as high AC-DC coupling strength, low system inertia, and weak voltage support capabilities. Deploying distributed synchronous condensers (SCs) within and around wind farms can effectively provide transient reactive power support, enhance grid system inertia at the transmission end, and improve dynamic frequency support capabilities. However, the high investment and maintenance costs of SCs hinder their large-scale deployment, necessitating the investigation of optimal SC configuration strategies at critical nodes in the transmission grid. Initially, a node inertia model was developed to identify weaknesses in dynamic frequency support, and a critical inertia constraint based on node frequency stability was proposed. Subsequently, a multi-timescale reactive power response model was formulated to quantify the impact on short-circuit ratio improvement and transient overvoltage suppression. Finally, a two-stage optimal configuration strategy for distributed SCs at the transmission end was proposed, considering dynamic frequency support and transient voltage stability. In the first stage, the optimal SC configuration aimed to maximize system inertia improvement per unit investment to meet dynamic frequency support requirements. In the second stage, the configuration results from the first stage were adjusted by incorporating constraints for enhancing the multiple renewable short-circuit ratio (MRSCR) and suppressing transient overvoltage. The proposed model was validated using the feeder grid of a large energy base in western China. The results demonstrate that the optimal configuration scheme effectively suppressed transient overvoltage at the generator end and significantly enhanced the system’s dynamic frequency support strength.


  • Open Access

    Source-Storage-Load Flexible Scheduling Strategy Considering Characteristics Complementary of Hydrogen Storage System and Flexible Carbon Capture System

    by Lang Zhao, Zhidong Wang, Haiqiong Yi, Yizheng Li, Xueying Wang, Yunpeng Xiao, Zhiyun Hu, Honglian Zhou, Xinhua Zhang

    In the current literature, there exists a lack of analysis regarding the coordination of the spinning reserve and time-shift characteristics of hydrogen storage systems (HSS) and flexible carbon capture systems (FCCS) in terms of low-carbon economic operation. They are presently used solely as a tool to capture carbon dioxide, without fully utilizing the advantages of their flexible operation. The coordination and complementarity of the FCCS and HSS can ensure stable power supply and improve renewable energy (RE) consumption. Combined with demand side response (DSR), these factors can maximize the RE consumption capacity, reduce carbon emissions, and improve revenue. In this paper, a source-storage-load flexible scheduling strategy is proposed by considering the complementary nature of FCCS and HSS in terms of rotating standby and time-shift characteristics. First, the operational mechanisms of FCCS, HSS, and demand side response (DSR) are analyzed, and their mathematical models are constructed to improve flexibility in grid operation and regulation. Next, deficiencies in FCCS and HSS operation under rotating reserve requirements are analyzed to design a coordinated operation framework for the FCCS and HSS. This operational framework aims to enable the complementarity of the rotating reserve and time-shift characteristics of FCCS and HSS. Finally, based on the carbon emission trading mechanism, a three-stage ladder carbon emission trading cost model is constructed, and a source-storage-load flexible scheduling strategy is established to achieve an effective balance between low carbon emissions and economic performance. The simulation results demonstrate that the strategy reduces the overall cost by 8.57%, reduces the carbon emissions by 35.33%, and improves the renewable energy consumption by 3.5% compared with the unoptimized scheme.


  • Open Access

    Optimal Economic Scheduling Method for Power Systems Based on Whole-System-Cost Electricity Price

    by Yizheng Li, Yuan Zeng, Zhidong Wang, Lang Zhao, Yao Wang

    At present, the traditional scheduling mode of power grids generally dispatches according to the power generation cost within the safe range. Transmission costs are evenly distributed to customers according to their load ratios. There are no methods for the rational distribution of transmission costs according to the utilization degree of generation and load to transmission network resources. This traditional scheduling mode will render transmission cost distribution unfair, and it is difficult to guide reasonable load distribution in time and space. Therefore, an optimal economic scheduling method for power systems based on the whole-system-cost electricity price is proposed in this paper. For the power generation and the transmission sides, the whole-system-cost electricity price model was constructed according to the power flow tracking method. For the load side, a demand-side response model of users’ responses to electricity price changes was established. Finally, the IEEE 57 node standard model was used to simulate optimal economic scheduling. The results show that the proposed method can guide the rational distribution of power flow. The power flow is shifted moderately from far away to near the power generation center, allowing for the load demand to be guided to meet nearby customers’ demands and preventing the line from blocking, the latter of which is conducive to ensuring the safety of the power grid.


  • Open Access

    Optimal Configuration Analysis Method of Energy Storage System Based on “Equal Area Criterion”

    by Yizheng Li, Yuan Zeng, Zhidong Wang, Lang Zhao, Yao Wang

    In order to solve the problem of randomness and volatility caused by the rapid growth of renewable energy (RE), energy storage systems (ESSs)—as an important means of regulation—can effectively improve the flexible regulation capacity of power systems utilizing a high proportion of RE. Most of the current ESS capacity configuration procedures are carried out based on the typical scenario method or time series production simulation. This method tends to determine the size of the ESS configuration through multiple trial simulations. Uncertainty of simulation prediction data can result in the existence of an excess capacity or lack of configured capacity. In addition, this method reflects the ESS demand under specific targets, but it fails to fully utilize RE generation characteristics. The configuration process lacks the mathematical mechanism of RE consumption, and the calculation process is too complicated. In view of the shortcomings of traditional ESS optimal configuration methods, this paper examines the mathematical mechanism of RE consumption and proposes the ESS optimal configuration analysis method based on “equal area criterion”. First, the principle of RE consumption is analyzed and the “RE consumption characteristic curve” is proposed according to RE characteristics. In addition, a working principle diagram of RE consumption, including ESS, is constructed to visually show the consumption capacity of RE and the working position of ESS. Then, the ESS optimal configuration process, based on the “equal area criterion”, is proposed to achieve an accurate match between ESS capacity demand and RE consumption targets. Finally, the power grid of a region in China is taken as an example. We prove that the proposed method can save 1.41 × 103 MWh of ESS capacity and provide a more “mathematical” and “convenient” systematic solution for RE consumption and ESS optimization compared to the production simulation method.

  • Open Access

    Application of Matter Element Analysis in Power Grid Development Diagnosis

    by Chao Xu, Di Huang, Zhe Chen, Dong Peng, Lang Zhao, Tianqi Zhang

    The structure and form of modern power grids are becoming more and more complex, and there are many indicators and factors that need to be considered to evaluate the development status of the power grid. In order to diagnose the development level of power grid, the index system is reconstructed, which includes seven dimensions: the coordination of power grid development speed, the coordination of power grid development scale, the coordination of power grid structure, the security and reliability of power grid, the level of equipment, the utilization efficiency of power grid and the development benefit of power grid, the construction principle and index selection basis are given. When dealing with contradictory problems in reality, methods combining quantitative and qualitative can be applied to study. The matter element analysis method is applied to power grid development diagnosis, and a model of power grid development diagnosis based on matter element analysis is established, the model can not only diagnose the development level of power grid, but also determine the key factors that affect the diagnosis results, and give suggestions for improvement. The practical example verifies the feasibility and rationality of the method, which has good evaluation accuracy and prediction effect.