XWXueying Wang

Xueying Wang

*This is an algorithmically generated author record based on publicly available information.

Xueying Wang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimal Configuration Model for Large Capacity Synchronous Condenser Considering Transient Voltage Stability in Multiple UHV DC Receiving End Grids

    by Lang Zhao, Zhidong Wang, Hao Sheng, Yizheng Li, Xueying Wang, Yao Wang, Haifeng Yu

    In a multi-fed DC environment, the UHV DC recipient grid faces significant challenges related to DC phase shift failure and voltage instability due to the high AC/DC coupling strength and low system inertia level. While the new large-capacity synchronous condensers (SCs) can provide effective transient reactive power support, the associated investment and operation costs are high. Therefore, it is valuable to investigate the optimization of SC configuration at key nodes in the recipient grid in a scientific and rational manner. This study begins by qualitatively and quantitatively analyzing the dynamic characteristics of DC reactive power and induction motors under AC faults. The sub-transient and transient reactive power output model is established to describe the SC output characteristics, elucidating the coupling relationship between the SC’s reactive power output and the DC reactive power demand at different time scales. Subsequently, a critical stabilized voltage index for dynamic loads is defined, and the SC’s reactive power compensation target is quantitatively calculated across different time scales, revealing the impact of transient changes in DC reactive power on the transient voltage stability of the multi-fed DC environment with dynamic load integration. Finally, an optimal configuration model for the large-capacity SC is proposed under the critical stability constraint of dynamic loads to maximize the SC’s reactive power support capability at the lowest economic cost. The proposed model is validated in a multi-fed DC area, demonstrating that the optimal configuration scheme effectively addresses issues related to DC phase shift failures and voltage instability resulting from AC bus voltage drops.


  • Open Access

    Two-Stage Optimal Configuration Strategy of Distributed Synchronous Condensers at the Sending End of Large-Scale Wind Power Generation Bases

    by Lang Zhao, Zhidong Wang, Yizheng Li, Xueying Wang, Zhiyun Hu, Yunpeng Xiao

    The transmission end of large-scale wind power generation bases faces challenges such as high AC-DC coupling strength, low system inertia, and weak voltage support capabilities. Deploying distributed synchronous condensers (SCs) within and around wind farms can effectively provide transient reactive power support, enhance grid system inertia at the transmission end, and improve dynamic frequency support capabilities. However, the high investment and maintenance costs of SCs hinder their large-scale deployment, necessitating the investigation of optimal SC configuration strategies at critical nodes in the transmission grid. Initially, a node inertia model was developed to identify weaknesses in dynamic frequency support, and a critical inertia constraint based on node frequency stability was proposed. Subsequently, a multi-timescale reactive power response model was formulated to quantify the impact on short-circuit ratio improvement and transient overvoltage suppression. Finally, a two-stage optimal configuration strategy for distributed SCs at the transmission end was proposed, considering dynamic frequency support and transient voltage stability. In the first stage, the optimal SC configuration aimed to maximize system inertia improvement per unit investment to meet dynamic frequency support requirements. In the second stage, the configuration results from the first stage were adjusted by incorporating constraints for enhancing the multiple renewable short-circuit ratio (MRSCR) and suppressing transient overvoltage. The proposed model was validated using the feeder grid of a large energy base in western China. The results demonstrate that the optimal configuration scheme effectively suppressed transient overvoltage at the generator end and significantly enhanced the system’s dynamic frequency support strength.


  • Open Access

    Source-Storage-Load Flexible Scheduling Strategy Considering Characteristics Complementary of Hydrogen Storage System and Flexible Carbon Capture System

    by Lang Zhao, Zhidong Wang, Haiqiong Yi, Yizheng Li, Xueying Wang, Yunpeng Xiao, Zhiyun Hu, Honglian Zhou, Xinhua Zhang

    In the current literature, there exists a lack of analysis regarding the coordination of the spinning reserve and time-shift characteristics of hydrogen storage systems (HSS) and flexible carbon capture systems (FCCS) in terms of low-carbon economic operation. They are presently used solely as a tool to capture carbon dioxide, without fully utilizing the advantages of their flexible operation. The coordination and complementarity of the FCCS and HSS can ensure stable power supply and improve renewable energy (RE) consumption. Combined with demand side response (DSR), these factors can maximize the RE consumption capacity, reduce carbon emissions, and improve revenue. In this paper, a source-storage-load flexible scheduling strategy is proposed by considering the complementary nature of FCCS and HSS in terms of rotating standby and time-shift characteristics. First, the operational mechanisms of FCCS, HSS, and demand side response (DSR) are analyzed, and their mathematical models are constructed to improve flexibility in grid operation and regulation. Next, deficiencies in FCCS and HSS operation under rotating reserve requirements are analyzed to design a coordinated operation framework for the FCCS and HSS. This operational framework aims to enable the complementarity of the rotating reserve and time-shift characteristics of FCCS and HSS. Finally, based on the carbon emission trading mechanism, a three-stage ladder carbon emission trading cost model is constructed, and a source-storage-load flexible scheduling strategy is established to achieve an effective balance between low carbon emissions and economic performance. The simulation results demonstrate that the strategy reduces the overall cost by 8.57%, reduces the carbon emissions by 35.33%, and improves the renewable energy consumption by 3.5% compared with the unoptimized scheme.