Mohammad Tavakoli Bina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mohammad Tavakoli Bina has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Amir Shahirinia
Department of Electrical and Computer Engineering, University of the District of Columbia, 4200 Connecticut Avenue NW, Wahington, DC 20008, USA
7 shared publications - Hossein Hafezi
Faculty of Information Technology and Communication Sciences, Tampere University, Tampere, Finland
3 shared publications - Mohammad Farsijani
Department of Electrical and Computer Engineering, University of Illinois Chicago, Chicago, IL, USA
3 shared publications - Sohrab Abbasian
Electrical Engineering Unit, Tampere University, Tampere, Finland
3 shared publications - Araz Saleki
Department of Electrical Engineering, K.N. Toosi University of Technology, Tehran, Iran
2 shared publications Farhad Bagheroskouei
Power Electronic Laboratory, K.N. Tossi University of Technology, Tehran, Iran
2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 104453-104467
Model-Based SMC Strategy for Speed Control With a Sensorless Load-Torque SM Observer: Analysis and Experimental Validation Using an IM
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 104453-104467
Open AccessModel-Based SMC Strategy for Speed Control With a Sensorless Load-Torque SM Observer: Analysis and Experimental Validation Using an IM
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 20 (1)
Modelling AC Induction Along a Pipeline Aligned With an Overhead Power Line: Analysis, Simulations and Field Measurements
The AC voltage is induced along a pipeline when an overhead power line is aligned with the pipeline. The AC induction needs to be analysed and determined even with cathodic protection systems (CPS) protecting pipelines, storage tanks, and many other metal surfaces in various industries to prevent electrochemical corrosion. Hence, the design and accurate operation of a CPS needs a proper model to monitor and assess the condition of pipelines aligned with overhead power lines. Conventional pipeline models, including lumped resistances introducing cables and connections, anode beds, and metal structures, do not represent the stated AC induction. This paper suggests a non‐uniform distributed model for pipelines aligned with overhead power lines driven by the CPS to determine the voltage profile across the long metal surfaces such as pipelines. The case study is an 11.5 km pipeline for gas transmission from a gas field located west of Iran, aligned with a three‐phase 20 kV overhead power line. First, the parameters of this gas pipeline model are analysed and obtained, which include resistances, non‐uniform inductances, and capacitances. Then, simulations are introduced for the developed distributed model. Finally, the voltage profile of the pipeline is obtained experimentally by measuring 23 points along the pipeline to confirm the model and simulations; also, waveforms of electrical potentials related to both ends and the midpoint are recorded by a portable oscilloscope for further verifications. Experimental results desirably validate the analytical distributed model and simulations.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 20 (1)
Open AccessModelling AC Induction Along a Pipeline Aligned With an Overhead Power Line: Analysis, Simulations and Field Measurements
The AC voltage is induced along a pipeline when an overhead power line is aligned with the pipeline. The AC induction needs to be analysed and determined even with cathodic protection systems (CPS) protecting pipelines, storage tanks, and many other metal surfaces in various industries to prevent electrochemical corrosion. Hence, the design and accurate operation of a CPS needs a proper model to monitor and assess the condition of pipelines aligned with overhead power lines. Conventional pipeline models, including lumped resistances introducing cables and connections, anode beds, and metal structures, do not represent the stated AC induction. This paper suggests a non‐uniform distributed model for pipelines aligned with overhead power lines driven by the CPS to determine the voltage profile across the long metal surfaces such as pipelines. The case study is an 11.5 km pipeline for gas transmission from a gas field located west of Iran, aligned with a three‐phase 20 kV overhead power line. First, the parameters of this gas pipeline model are analysed and obtained, which include resistances, non‐uniform inductances, and capacitances. Then, simulations are introduced for the developed distributed model. Finally, the voltage profile of the pipeline is obtained experimentally by measuring 23 points along the pipeline to confirm the model and simulations; also, waveforms of electrical potentials related to both ends and the midpoint are recorded by a portable oscilloscope for further verifications. Experimental results desirably validate the analytical distributed model and simulations.
- Open Access
- 28 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 79596-79608
Multi-Site Wind Farms Dependence Structure Using Vine Copulas: Impacts of Dataset Sizes and Employed Copulas
Using copulas in statistics evaluates the dependence between random variables. Copula modeling has significantly been used in many areas, especially in the search for multivariate distributions. As wind energy rapidly becomes an important renewable energy source, it is very important to deeply evaluate any potential existing dependencies among the data. This study introduces a comprehensive application of vine copulas in modeling multi-site wind speed dependencies for different sizes of datasets, offering a more flexible approach than traditional correlation-based methods. Unlike previous studies, this work systematically evaluates the impact of dataset sizes on the selection of the best-performing vine copula structures, providing valuable insights for improving wind forecasting and grid stability. These evaluations are studied using R-vine, C-and D-vine models by applying pair copulas families and the pairwise empirical Kendall’s τ values, where the appropriate model is selected based on the Akaike Information Criteria (AIC), the Bayesian Information Criteria (BIC), and the likelihood method (Log-likelihood). This study finds out the best vine copula model for three different wind speed datasets, namely hourly (large), daily (medium), and small (weekly). Also, using all pair copulas families (Clayton, Frank, Gumbel, Student’s t, and Gaussian), vine copula simulations provide guidelines for conceptual understanding of mutual impacts and correlations among multi-site wind farms. Simulations also show that the R-vine copula is the best structure for both large and small datasets, while the C-vine copula is the best structure for medium datasets.
- 28 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 79596-79608
Open AccessMulti-Site Wind Farms Dependence Structure Using Vine Copulas: Impacts of Dataset Sizes and Employed Copulas
Using copulas in statistics evaluates the dependence between random variables. Copula modeling has significantly been used in many areas, especially in the search for multivariate distributions. As wind energy rapidly becomes an important renewable energy source, it is very important to deeply evaluate any potential existing dependencies among the data. This study introduces a comprehensive application of vine copulas in modeling multi-site wind speed dependencies for different sizes of datasets, offering a more flexible approach than traditional correlation-based methods. Unlike previous studies, this work systematically evaluates the impact of dataset sizes on the selection of the best-performing vine copula structures, providing valuable insights for improving wind forecasting and grid stability. These evaluations are studied using R-vine, C-and D-vine models by applying pair copulas families and the pairwise empirical Kendall’s τ values, where the appropriate model is selected based on the Akaike Information Criteria (AIC), the Bayesian Information Criteria (BIC), and the likelihood method (Log-likelihood). This study finds out the best vine copula model for three different wind speed datasets, namely hourly (large), daily (medium), and small (weekly). Also, using all pair copulas families (Clayton, Frank, Gumbel, Student’s t, and Gaussian), vine copula simulations provide guidelines for conceptual understanding of mutual impacts and correlations among multi-site wind farms. Simulations also show that the R-vine copula is the best structure for both large and small datasets, while the C-vine copula is the best structure for medium datasets.
- Open Access
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Nonlinear Control of Inertial Response for HVDC‐Connected Offshore Wind Farms
The growing penetration of renewable energy resources could be a major concern in terms of the primary frequency response of the grid. Nevertheless, this can potentially be addressed by the inertial response of the grid‐connected DFIG‐based offshore wind farms through VSC‐HVDC‐VSC (voltage‐sourced converter). However, the inherent nonlinearity of this system leads to unsatisfactory performance when controlled with linear controllers. This paper proposes a nonlinear control strategy specifically designed to enable robust inertial support under the grid frequency events. A detailed nonlinear model is developed for the entire system, including the wind turbine, DFIG converters, HVDC transmission system, and grid interface. Unlike conventional omission of nonlinear terms, the output feedback linearisation (FL) is applied to transform the coordinates of the nonlinear system into a new coordinate representing a linear structure while fully retaining the original nonlinearities, thereby ensuring accurate dynamic representation. Furthermore, a sliding mode control (SMC) strategy is proposed to ensure robust system performance in the face of load variations and uncertainties in the engaged system and grid parameters. The stability of the system's internal dynamics and the sliding surface in the SMC is demonstrated using Lyapunov's method. The performance of the proposed controller is validated through various simulations under different scenarios by employing the IEEE 39‐bus test system.
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Open AccessNonlinear Control of Inertial Response for HVDC‐Connected Offshore Wind Farms
The growing penetration of renewable energy resources could be a major concern in terms of the primary frequency response of the grid. Nevertheless, this can potentially be addressed by the inertial response of the grid‐connected DFIG‐based offshore wind farms through VSC‐HVDC‐VSC (voltage‐sourced converter). However, the inherent nonlinearity of this system leads to unsatisfactory performance when controlled with linear controllers. This paper proposes a nonlinear control strategy specifically designed to enable robust inertial support under the grid frequency events. A detailed nonlinear model is developed for the entire system, including the wind turbine, DFIG converters, HVDC transmission system, and grid interface. Unlike conventional omission of nonlinear terms, the output feedback linearisation (FL) is applied to transform the coordinates of the nonlinear system into a new coordinate representing a linear structure while fully retaining the original nonlinearities, thereby ensuring accurate dynamic representation. Furthermore, a sliding mode control (SMC) strategy is proposed to ensure robust system performance in the face of load variations and uncertainties in the engaged system and grid parameters. The stability of the system's internal dynamics and the sliding surface in the SMC is demonstrated using Lyapunov's method. The performance of the proposed controller is validated through various simulations under different scenarios by employing the IEEE 39‐bus test system.
- 14 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 15 (4) , 2777-2788
Inertial Frequency Response of Wind Turbines Using Adaptive Full Feedback Linearization Control: Stability and Robustness Analysis
It is a challenging task to affect suitably on the frequency response of a variable speed wind turbine (VSWT). The problem would be more crucial when the system is subjected to uncertainty in parameters as well as various external effects such as load changes and grid disturbances. Feedback linearization has already been applied to the VSWT, where two state variables experience instability. Hence, this paper presents a new methodology based on full-state feedback linearization in which by choosing an appropriate output, the closed-loop system is fully linearized, and the resulting linear system is stabilized by an optimal linear quadratic regulator (LQR). Since the parameters may be uncertain, the developed controller is augmented with an adaptive dynamic feedback such that all of the parameters are estimated while asymptotic stability is ensured by the Lyapunov method. Furthermore, robustness analysis is performed, and the effects of external disturbance are reduced by suitable selection of the gains. The analytical outcomes are verified through simulations, where these are compared with those of available work to show the improvement have been made by the suggested method.
- 14 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 15 (4) , 2777-2788
Inertial Frequency Response of Wind Turbines Using Adaptive Full Feedback Linearization Control: Stability and Robustness Analysis
It is a challenging task to affect suitably on the frequency response of a variable speed wind turbine (VSWT). The problem would be more crucial when the system is subjected to uncertainty in parameters as well as various external effects such as load changes and grid disturbances. Feedback linearization has already been applied to the VSWT, where two state variables experience instability. Hence, this paper presents a new methodology based on full-state feedback linearization in which by choosing an appropriate output, the closed-loop system is fully linearized, and the resulting linear system is stabilized by an optimal linear quadratic regulator (LQR). Since the parameters may be uncertain, the developed controller is augmented with an adaptive dynamic feedback such that all of the parameters are estimated while asymptotic stability is ensured by the Lyapunov method. Furthermore, robustness analysis is performed, and the effects of external disturbance are reduced by suitable selection of the gains. The analytical outcomes are verified through simulations, where these are compared with those of available work to show the improvement have been made by the suggested method.
- Open Access
- 1 April 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (4)
Spatial modeling sensitivity analysis: Copula selection for wind speed dependence
As the adoption of wind energy as a key renewable energy source accelerates, precise power flow analysis becomes crucial for accurate power delivery forecasting. This paper addresses the inherent uncertainties in wind speed data at different wind farm locations by conducting a sensitivity analysis to assess wind farm pairs. The analysis accommodates various data sizes, namely, short, medium, and large, and diverse spatial relationships between wind farms. By leveraging National Renewable Energy Laboratory wind speed data from nine distinct wind farms, the dependence structure between wind farm pairs is modeled using copulas. This modeling takes both the wind speed knowledge level and the various spatial interplays among the wind farm pairs into consideration. The findings indicate an inverse proportionality between the strength of dependence and the distance separating the wind farm pairs.
- 1 April 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (4)
Open AccessSpatial modeling sensitivity analysis: Copula selection for wind speed dependence
As the adoption of wind energy as a key renewable energy source accelerates, precise power flow analysis becomes crucial for accurate power delivery forecasting. This paper addresses the inherent uncertainties in wind speed data at different wind farm locations by conducting a sensitivity analysis to assess wind farm pairs. The analysis accommodates various data sizes, namely, short, medium, and large, and diverse spatial relationships between wind farms. By leveraging National Renewable Energy Laboratory wind speed data from nine distinct wind farms, the dependence structure between wind farm pairs is modeled using copulas. This modeling takes both the wind speed knowledge level and the various spatial interplays among the wind farm pairs into consideration. The findings indicate an inverse proportionality between the strength of dependence and the distance separating the wind farm pairs.
- 20 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 69 (3) , 458-466
Suggesting a Non-Unity Turn Ratio Two-Winding Coupled Inductor for Filtering CM EMI Noise in an SRC
Switched-mode power supplies (SMPS) are the source of both conducted and radiated electromagnetic interference (EMI) noise. Resonant converters are popular due to the possibility of switching loss reduction using zero voltage switching (ZVS) or zero current switching (ZCS) and also attenuating conducted EMI noise. Conventionally, a common-mode (CM) choke with a single core and two identical windings is used to suppress the CM noise in an EMI filter. This paper introduces an effective and cost-efficient method for mitigating the CM EMI noise in SRCs. The proposed method benefits a two-winding coupled inductor instead of the simple resonant inductor in the SRC. While a unity turn ratio does not meet the desired resonance inductance, the suggested two windings coupled inductor with an unequal number of turns deals with the EMI noise as well as the normal operation of an inductor in the resonant tank. Applying the proposed method significantly achieves up to 20 dB attenuation in the noise amplitude both at the input and output terminals of the converter. Simulations are used for investigating the analysis of the method. Moreover, a series resonant converter is designed and implemented to verify both analysis and simulations.
- 20 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 69 (3) , 458-466
Suggesting a Non-Unity Turn Ratio Two-Winding Coupled Inductor for Filtering CM EMI Noise in an SRC
Switched-mode power supplies (SMPS) are the source of both conducted and radiated electromagnetic interference (EMI) noise. Resonant converters are popular due to the possibility of switching loss reduction using zero voltage switching (ZVS) or zero current switching (ZCS) and also attenuating conducted EMI noise. Conventionally, a common-mode (CM) choke with a single core and two identical windings is used to suppress the CM noise in an EMI filter. This paper introduces an effective and cost-efficient method for mitigating the CM EMI noise in SRCs. The proposed method benefits a two-winding coupled inductor instead of the simple resonant inductor in the SRC. While a unity turn ratio does not meet the desired resonance inductance, the suggested two windings coupled inductor with an unequal number of turns deals with the EMI noise as well as the normal operation of an inductor in the resonant tank. Applying the proposed method significantly achieves up to 20 dB attenuation in the noise amplitude both at the input and output terminals of the converter. Simulations are used for investigating the analysis of the method. Moreover, a series resonant converter is designed and implemented to verify both analysis and simulations.
- Open Access
- 3 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 2092-2104
Design and Implementation of a Single Switch High Gain Boost Topology: Structure, Ripple Control and ZCS
The need for high gain DC-DC converters has lately increased in tandem with the utilization of renewable energy supplies. Particularly appealing are high gain converters that do not require the inclusion of extra power switches and/or other passive elements to the system. As a result, this study proposes a non-isolated single switch converter with ultra-high voltage gain (UHG) that is appropriate for most renewable energy conversion systems, like solar installations. With only a single MOSFET working within a suitable duty cycle region, the proposed converter provides significant voltage gain and around 95% efficiency. Moreover, the MOSFET in this UHG converter is turned on in zero current switching (ZCS) mode, resolving the diode recovery issue. The recommended UHG converter’s working modes, steady-state parametric study, circuit variables like voltage stress on switching devices, and converter gain are all thoroughly explained. Comparisons have been done with comparable topologies presented in the literature, and lastly, experimental results depending on 200W (20V input, 320V output voltage) are given to validate the operation of the proposed UHG design.
- 3 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 2092-2104
Open AccessDesign and Implementation of a Single Switch High Gain Boost Topology: Structure, Ripple Control and ZCS
The need for high gain DC-DC converters has lately increased in tandem with the utilization of renewable energy supplies. Particularly appealing are high gain converters that do not require the inclusion of extra power switches and/or other passive elements to the system. As a result, this study proposes a non-isolated single switch converter with ultra-high voltage gain (UHG) that is appropriate for most renewable energy conversion systems, like solar installations. With only a single MOSFET working within a suitable duty cycle region, the proposed converter provides significant voltage gain and around 95% efficiency. Moreover, the MOSFET in this UHG converter is turned on in zero current switching (ZCS) mode, resolving the diode recovery issue. The recommended UHG converter’s working modes, steady-state parametric study, circuit variables like voltage stress on switching devices, and converter gain are all thoroughly explained. Comparisons have been done with comparable topologies presented in the literature, and lastly, experimental results depending on 200W (20V input, 320V output voltage) are given to validate the operation of the proposed UHG design.
- Open Access
- 19 November 2022
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 16 (5) , 816-827
An interleaved non‐isolated high gain soft switching DC–DC converter with small input current ripple
This article suggests a non‐isolated high step‐up interleaved DC–DC topology for renewable energy applications. Two three‐winding coupled‐inductors along with two voltage multiplier cells are used to enhance the voltage gain significantly. One interesting aspect of this new topology is that high duty cycles are not required to achieve high voltage gains; this is done by adjusting the turn ratio of the coupled inductors. Moreover, the presented interleaved converter enjoys not only having less current stress due to the interleaving structure, but also showing 16% increase in voltage gain compared to the best similar boost topologies. Additional elements are designed for the purpose of soft switching and gain increase, which have little effect on the cost, weight and size of the proposed converter. Interestingly, the voltage stresses both on the switching devices and passive elements are much less than the output voltage. Furthermore, the coupled inductor's leakage inductance energy is recovered by employing a passive clamp circuit to minimize stresses across the semiconductors; therefore, efficiency is improved. The suggested converter is analyzed in the steady state, and a 400 W experimental setup was implemented; the outcomes verify the practicality of the proposed boost converter in accordance with the analysis.
- 19 November 2022
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 16 (5) , 816-827
Open AccessAn interleaved non‐isolated high gain soft switching DC–DC converter with small input current ripple
This article suggests a non‐isolated high step‐up interleaved DC–DC topology for renewable energy applications. Two three‐winding coupled‐inductors along with two voltage multiplier cells are used to enhance the voltage gain significantly. One interesting aspect of this new topology is that high duty cycles are not required to achieve high voltage gains; this is done by adjusting the turn ratio of the coupled inductors. Moreover, the presented interleaved converter enjoys not only having less current stress due to the interleaving structure, but also showing 16% increase in voltage gain compared to the best similar boost topologies. Additional elements are designed for the purpose of soft switching and gain increase, which have little effect on the cost, weight and size of the proposed converter. Interestingly, the voltage stresses both on the switching devices and passive elements are much less than the output voltage. Furthermore, the coupled inductor's leakage inductance energy is recovered by employing a passive clamp circuit to minimize stresses across the semiconductors; therefore, efficiency is improved. The suggested converter is analyzed in the steady state, and a 400 W experimental setup was implemented; the outcomes verify the practicality of the proposed boost converter in accordance with the analysis.