Héctor Guerrero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Héctor Guerrero has a total of 120 co-authors. Here are the top co-authors by number of shared publications:
- Rafael Perez del Real
Instituto de Ciencia de Materiales de Madrid, CSIC, Madrid, 28049, Spain
12 shared publications - Eusebio Bernabeu
Univ Complutense Madrid, Appl Opt Complutense Grp, Dept Opt, Fac Ciencias Fis, E-28040 Madrid, Spain
9 shared publications I. Arruego
Departamento de Programas Espaciales y Ciencias del Espacio, Instituto Nacional de Técnica Aeroespacial (INTA), Torrejón de Ardoz, Spain
8 shared publications- Maite Alvarez
Instituto Nacional de Tècnica Aeroespacial" (INTA), Torrejón de Ardoz, 28850 Madrid, Spain
8 shared publications - David Levy
Instituto de Ciencia de Materiales de Madrid, ICMM. CSIC
7 shared publications G. Rosa
Instituto Nacional de Técnica Aeroespacial (INTA)
6 shared publications
Latest Publications
- 11 November 2017
- Published by Springer Nature in CEAS Space Journal
- Vol. 9 (4) , 543-554
OWLS as platform technology in OPTOS satellite
- 11 November 2017
- Published by Springer Nature in CEAS Space Journal
- Vol. 9 (4) , 543-554
OWLS as platform technology in OPTOS satellite
- Open Access
- 30 November 2016
- Published by Universidad Complutense de Madrid (UCM) in Física de la Tierra
- Vol. 28, 65-82
El Magnetómetro MOURA para la Misión Mars MetNet Precursor y su potencial para la caracterización magnética de la superficie del Planeta
El magnetómetro y gradiómetro MOURA forma parte de la instrumentación científica de la misión precursora de MetNet a Marte. En este trabajo se describen los objetivos de esta investigación, se recopilan las tareas de diseño y desarrollo del mismo así como su posterior calibración y se muestran las principales acciones de demostración emprendidas con el instrumento que muestran su capacidad para medidas magnéticas a bordo de aterrizadores y rovers.
- 30 November 2016
- Published by Universidad Complutense de Madrid (UCM) in Física de la Tierra
- Vol. 28, 65-82
Open AccessEl Magnetómetro MOURA para la Misión Mars MetNet Precursor y su potencial para la caracterización magnética de la superficie del Planeta
El magnetómetro y gradiómetro MOURA forma parte de la instrumentación científica de la misión precursora de MetNet a Marte. En este trabajo se describen los objetivos de esta investigación, se recopilan las tareas de diseño y desarrollo del mismo así como su posterior calibración y se muestran las principales acciones de demostración emprendidas con el instrumento que muestran su capacidad para medidas magnéticas a bordo de aterrizadores y rovers.
- 14 May 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 60 (4) , 2461-2468
Dosimeter for The Two Towers in SEOSAT-INGENIO Based on the TMP36 Temperature Sensor
A dosimeter for space applications is presented. It is based on the ionization damage affecting the TMP36 sensors when they are exposed to external radiation, which produces an increase of their output voltages. This work explains the configuration, sensing mechanism and working modes of this device and reports the results obtained in a gamma radiation test carried out in March 2012. The test results allow us to select the mode of operation that provides the highest response to the TID, as well as the most sensitive devices. The highest sensitivity is above 100 μV/rad. This dosimeter is part of The Two Towers radiation monitor that will fly on board of the SEOSAT-INGENIO satellite.
- 14 May 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 60 (4) , 2461-2468
Dosimeter for The Two Towers in SEOSAT-INGENIO Based on the TMP36 Temperature Sensor
A dosimeter for space applications is presented. It is based on the ionization damage affecting the TMP36 sensors when they are exposed to external radiation, which produces an increase of their output voltages. This work explains the configuration, sensing mechanism and working modes of this device and reports the results obtained in a gamma radiation test carried out in March 2012. The test results allow us to select the mode of operation that provides the highest response to the TID, as well as the most sensitive devices. The highest sensitivity is above 100 μV/rad. This dosimeter is part of The Two Towers radiation monitor that will fly on board of the SEOSAT-INGENIO satellite.
- 1 July 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Total Ionizing Dose Radiation Test on the Temperature Sensor TMP36 from Analog Devices
TMP36 temperature sensors were irradiated with Co-60 gamma rays up to 35 krad(Si). This temperature sensor will be used as a total ionizing dose sensor in a radiation monitor that will be on board the Spanish Earth observation satellite SEOSAT/INGENIO. Several samples were irradiated at different dose rates while their response was continuously measured. The sensitivity of the TMP36 to the total ionizing dose has been assessed by studying the evolution of the next three metrics: the output voltage, its temperature dependence and the power consumption. It has been observed that the degradation of these parameters increase significantly at doses higher than about 7 krad(Si), independently of the dose rate.
- 1 July 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Total Ionizing Dose Radiation Test on the Temperature Sensor TMP36 from Analog Devices
TMP36 temperature sensors were irradiated with Co-60 gamma rays up to 35 krad(Si). This temperature sensor will be used as a total ionizing dose sensor in a radiation monitor that will be on board the Spanish Earth observation satellite SEOSAT/INGENIO. Several samples were irradiated at different dose rates while their response was continuously measured. The sensitivity of the TMP36 to the total ionizing dose has been assessed by studying the evolution of the next three metrics: the output voltage, its temperature dependence and the power consumption. It has been observed that the degradation of these parameters increase significantly at doses higher than about 7 krad(Si), independently of the dose rate.
- 6 June 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 59 (4) , 1092-1098
Proton Monitor Las Dos Torres: First Intercomparison of In-Orbit Results
A new proton monitor on board NANOSAT-1B—Las Dos Torres (translated: The Two Towers)—and its preliminary results after two years in orbit and its intercomparison to a RadFET and to trapped proton models are presented. This satellite was fully developed by INTA (National Institute of Aerospace Technology, Spain) and was launched on July 29, 2009. The instrument includes two stacks of radiation-sensing elements: the “dark” and “light” towers. The displacement damage was measured, both through the increase of a photodiode dark current (“dark tower”) and the decrease of the photocurrent signal in a photodiode optically linked to light emitting diodes (“light tower”). The instrument was also designed to monitor the ionization current of the photodiodes and the variations in the proton flux in the South Atlantic Anomaly.
- 6 June 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 59 (4) , 1092-1098
Proton Monitor Las Dos Torres: First Intercomparison of In-Orbit Results
A new proton monitor on board NANOSAT-1B—Las Dos Torres (translated: The Two Towers)—and its preliminary results after two years in orbit and its intercomparison to a RadFET and to trapped proton models are presented. This satellite was fully developed by INTA (National Institute of Aerospace Technology, Spain) and was launched on July 29, 2009. The instrument includes two stacks of radiation-sensing elements: the “dark” and “light” towers. The displacement damage was measured, both through the increase of a photodiode dark current (“dark tower”) and the decrease of the photocurrent signal in a photodiode optically linked to light emitting diodes (“light tower”). The instrument was also designed to monitor the ionization current of the photodiodes and the variations in the proton flux in the South Atlantic Anomaly.
- 1 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 58 (6) , 3067-3075
In-Orbit Measurement of SET and DD Effects on Optical Wireless Links for Intra-Satellite Data Transmission
In-orbit measurements of two experimental optical-wireless data links on board a polar LEO (Low Earth Orbit) spacecraft are presented. The effects of single event transients on the bit error rate, as well as those of displacement damage on the optoelectronic components being used, were measured. The results are consistent with those obtained from proton irradiations carried out in ground facilities.
- 1 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 58 (6) , 3067-3075
In-Orbit Measurement of SET and DD Effects on Optical Wireless Links for Intra-Satellite Data Transmission
In-orbit measurements of two experimental optical-wireless data links on board a polar LEO (Low Earth Orbit) spacecraft are presented. The effects of single event transients on the bit error rate, as well as those of displacement damage on the optoelectronic components being used, were measured. The results are consistent with those obtained from proton irradiations carried out in ground facilities.
- 1 September 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 03796566,p. 587-594
Proton monitor Las Dos Torres: First intercomparison of in-orbit results
The proton monitor on board NANOSAT 1B - Las Dos Torres (translated, The Two Towers) - and its preliminary results after two years in orbit are presented. This satellite was fully developed by INTA (National Institute of Aerospace Technique, Spain) and was launched on the 29 th of July, 2009. The instrument includes two stacks of radiation sensing elements: the `dark' and `light' towers. The displacement damage was measured, both through the increase of a photodiode dark current (`dark tower'), and the decrease of the photocurrent signal in a photodiode optically linked to an IRED (`light tower'). The instrument was also designed to monitor the ionization current of the photodiodes and it can monitor variations in the proton flux in the South Atlantic Anomaly (SAA).
- 1 September 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 03796566,p. 587-594
Proton monitor Las Dos Torres: First intercomparison of in-orbit results
The proton monitor on board NANOSAT 1B - Las Dos Torres (translated, The Two Towers) - and its preliminary results after two years in orbit are presented. This satellite was fully developed by INTA (National Institute of Aerospace Technique, Spain) and was launched on the 29 th of July, 2009. The instrument includes two stacks of radiation sensing elements: the `dark' and `light' towers. The displacement damage was measured, both through the increase of a photodiode dark current (`dark tower'), and the decrease of the photocurrent signal in a photodiode optically linked to an IRED (`light tower'). The instrument was also designed to monitor the ionization current of the photodiodes and it can monitor variations in the proton flux in the South Atlantic Anomaly (SAA).
- 21 May 2010
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 20 (7)
Comparative performance of static-mode ferrous MEMS gradiometers fabricated by a three-step DRIE process
- 21 May 2010
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 20 (7)
Comparative performance of static-mode ferrous MEMS gradiometers fabricated by a three-step DRIE process
- 6 May 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Aerospace and Electronic Systems
- Vol. 46 (2) , 542-557
COTS-Based Wireless Magnetic Sensor for Small Satellites
We report on the utilization of a commercial off-the-shelf (COTS) magnetic sensor for the mission NANOSAT-01 and the set of tests that have been developed to up-screen it. The magnetic sensor head is a Wheatstone bridge formed by four anisotropic magnetoresistances (AMR). AMR sensors are an adequate choice for medium- to high-sensitivity (~3 mV/V/G) and resolution (~ 3 ¿G) requirements, mostly due to their low weight and volume that are so interesting for the aerospace industry. The whole system installed in NANOSAT-01 is formed by two biaxial sensors with two redundant PCBs (printed circuit boards) of RAD-HARD proximity electronics, which conditions the AMR output signal, measure the temperature, and resets the AMR. This magnetic sensor belongs to the attitude control system (ACS) of the satellite.
- 6 May 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Aerospace and Electronic Systems
- Vol. 46 (2) , 542-557
COTS-Based Wireless Magnetic Sensor for Small Satellites
We report on the utilization of a commercial off-the-shelf (COTS) magnetic sensor for the mission NANOSAT-01 and the set of tests that have been developed to up-screen it. The magnetic sensor head is a Wheatstone bridge formed by four anisotropic magnetoresistances (AMR). AMR sensors are an adequate choice for medium- to high-sensitivity (~3 mV/V/G) and resolution (~ 3 ¿G) requirements, mostly due to their low weight and volume that are so interesting for the aerospace industry. The whole system installed in NANOSAT-01 is formed by two biaxial sensors with two redundant PCBs (printed circuit boards) of RAD-HARD proximity electronics, which conditions the AMR output signal, measure the temperature, and resets the AMR. This magnetic sensor belongs to the attitude control system (ACS) of the satellite.
- 30 April 2010
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 159 (1) , 33-40
In situ MEMS gradiometer with nanometer-resolution optical detection system
- 30 April 2010
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 159 (1) , 33-40
In situ MEMS gradiometer with nanometer-resolution optical detection system