Total Ionizing Dose Radiation Test on the Temperature Sensor TMP36 from Analog Devices
Authors:
- Maite ÁlvarezMÁMaite Álvarez
- Juan J. JiménezJJJuan J. Jiménez
- Miguel González-GuerreroMGMiguel González-Guerrero
- Carlos HernandoCHCarlos Hernando
- Héctor GuerreroHGHéctor Guerrero
- 1 July 2012
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Abstract
TMP36 temperature sensors were irradiated with Co-60 gamma rays up to 35 krad(Si). This temperature sensor will be used as a total ionizing dose sensor in a radiation monitor that will be on board the Spanish Earth observation satellite SEOSAT/INGENIO. Several samples were irradiated at different dose rates while their response was continuously measured. The sensitivity of the TMP36 to the total ionizing dose has been assessed by studying the evolution of the next three metrics: the output voltage, its temperature dependence and the power consumption. It has been observed that the degradation of these parameters increase significantly at doses higher than about 7 krad(Si), independently of the dose rate.Keywords
This publication has 2 references indexed in Scilit:
- The effect of proton and gamma radiation on different types of temperature sensors2009
- Neutron and gamma radiation tests of the analog devices TMP37 temperature sensorsIEEE Transactions on Nuclear Science, 2004