V. P. Saganov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
V. P. Saganov has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- A. V. Mongush
Buryat State University Named after Dorzhi Banzarov
1 shared publication - D. N. Sambuev
Republican Clinical Hospital of Emergency Medicine n.a. V.V. Angapov 1 Stroiteley Ave, Ulan-Ude, 660023, Russia
1 shared publication - Georgiy Ts. Dambaev
Siberian State Medical University
1 shared publication - K. Ts. Erdyneev
Republican Clinical Hospital of Emergency Medicine n.a. V.V. Angapov 1 Stroiteley Ave, Ulan-Ude, 660023, Russia
1 shared publication - Oleg Vladimirovich Zaitsev
Ryazan State Medical University named after academician I. P. Pavlov, Ministry of Health of Russia, Ryazan, Russia
1 shared publication - P. M. Zherbakhanov
Republican Clinical Hospital of Emergency Medicine n.a. V.V. Angapov 1 Stroiteley Ave, Ulan-Ude, 660023, Russia
1 shared publication
Latest Publications
- Open Access
- 28 October 2025
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 28 (3) , 97-106
Prospective testing of the effectiveness and safety of using a medical device “Wound coating based on the NovoSkin collagen-laminate matrix”
The study examines the effectiveness and safety of the medical device “Wound coating based on the NovoSkin collagen-laminate matrix”, conducted from February to May 2024 at the Ryazan State Medical University (Ryazan, Russia). Purpose of a study: to evaluate the use of wound coating NovoSkin in patients with skin defects. Materials and methods. NovoSkin is a sterile, round-shaped coating with a uniform matte and transparent surface. It is made of type 1 collagen and laminin, using safe ingredients, which makes it biocompatible and absorbable within 10–14 days. The use of the coating is indicated for burns of I–III degrees, trophic ulcers and pressure sores, however, it is contraindicated in open bleeding wounds and hypersensitivity to the components. The study included 60 patients (28 men (46.67 %) were and 32 women (53.33 %)) aged from 27 to 92 years (mean age (66.8 ± ± 12.4) years old). The main procedures included demographic data collection, local screening, vital signs assessment, and NovoSkin application. Efficacy was assessed by the percentage of patients with an increase in granulation area of at least 20 % by day 14. The results. Absolute majority (96.67 %) of patients showed a significant increase in granulations, indicating a high coverage efficiency. The safety of the application was assessed through the frequency of undesirable events and changes in vital signs. No serious adverse events have been reported, which confirms NovoSkin’s good tolerability. Conclusion. NovoSkin wound coating has demonstrated high efficacy and safety in the treatment of skin defects, which makes it a promising tool in clinical practice. The test results confirm the product’s compliance with established standards and its feasibility for use in medical institutions.
- 28 October 2025
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 28 (3) , 97-106
Open AccessProspective testing of the effectiveness and safety of using a medical device “Wound coating based on the NovoSkin collagen-laminate matrix”
The study examines the effectiveness and safety of the medical device “Wound coating based on the NovoSkin collagen-laminate matrix”, conducted from February to May 2024 at the Ryazan State Medical University (Ryazan, Russia). Purpose of a study: to evaluate the use of wound coating NovoSkin in patients with skin defects. Materials and methods. NovoSkin is a sterile, round-shaped coating with a uniform matte and transparent surface. It is made of type 1 collagen and laminin, using safe ingredients, which makes it biocompatible and absorbable within 10–14 days. The use of the coating is indicated for burns of I–III degrees, trophic ulcers and pressure sores, however, it is contraindicated in open bleeding wounds and hypersensitivity to the components. The study included 60 patients (28 men (46.67 %) were and 32 women (53.33 %)) aged from 27 to 92 years (mean age (66.8 ± ± 12.4) years old). The main procedures included demographic data collection, local screening, vital signs assessment, and NovoSkin application. Efficacy was assessed by the percentage of patients with an increase in granulation area of at least 20 % by day 14. The results. Absolute majority (96.67 %) of patients showed a significant increase in granulations, indicating a high coverage efficiency. The safety of the application was assessed through the frequency of undesirable events and changes in vital signs. No serious adverse events have been reported, which confirms NovoSkin’s good tolerability. Conclusion. NovoSkin wound coating has demonstrated high efficacy and safety in the treatment of skin defects, which makes it a promising tool in clinical practice. The test results confirm the product’s compliance with established standards and its feasibility for use in medical institutions.
- Open Access
- 25 June 2022
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 25 (2) , 38-44
Usage of shape memory implants in the formation of interstitial anastomoses in the experiment
The purpose of the study was to study in an experiment the advantages of creating interintestinal anastomoses using a construction with thermomechanical memory made of titanium nickelide in comparison with the classical method of imposing interintestinal anastomoses. The work was carried out on mongrel dogs by the method of performing compression and ligature interintestinal anastomoses. The tissue response in the area of interintestinal anastomosis was studied by the authors and confirmed by histological studies. In the studied tissues of the compression interintestinal anastomosis, microscopically, the indicators of the reactive inflammatory process were less pronounced and, ultimately, no dystrophic changes and tissue nutritional disorders were found in the test material. The healing of the intestinal mucosa was significantly better than in the classical ligature anastomosis. On the basis of the experimental data obtained by us, it was concluded that the use of compression interintestinal anastomoses for the purpose of creating anastomoses occurs with the best conditions for wound healing at the site of imposition of the performed anastomosis, in contrast to the classical ligature anastomosis.
- 25 June 2022
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 25 (2) , 38-44
Open AccessUsage of shape memory implants in the formation of interstitial anastomoses in the experiment
The purpose of the study was to study in an experiment the advantages of creating interintestinal anastomoses using a construction with thermomechanical memory made of titanium nickelide in comparison with the classical method of imposing interintestinal anastomoses. The work was carried out on mongrel dogs by the method of performing compression and ligature interintestinal anastomoses. The tissue response in the area of interintestinal anastomosis was studied by the authors and confirmed by histological studies. In the studied tissues of the compression interintestinal anastomosis, microscopically, the indicators of the reactive inflammatory process were less pronounced and, ultimately, no dystrophic changes and tissue nutritional disorders were found in the test material. The healing of the intestinal mucosa was significantly better than in the classical ligature anastomosis. On the basis of the experimental data obtained by us, it was concluded that the use of compression interintestinal anastomoses for the purpose of creating anastomoses occurs with the best conditions for wound healing at the site of imposition of the performed anastomosis, in contrast to the classical ligature anastomosis.
- Open Access
- 8 June 2021
- Published by Association of Spine Surgeons in Russian Journal of Spine Surgery (Khirurgiya Pozvonochnika)
- Vol. 18 (2) , 83-92
The use of various materials and drugs for the prevention of the development of postoperative lumbar epidural fibrosis: literature review
The paper is a review of the current literature data on the use of various materials and drugs for the prevention of the development of postoperative lumbar epidural fibrosis. Literature searches were performed in the Pubmed, Medline, EMBASE, Cochrane Library and eLibrary databases. The formation and growth of fibrous tissue in the epidural space, followed by tissue adhesion to the dura mater, is the leading cause of pain afferentation in the lumbar spine and/or lower extremities. Several molecular and cellular mechanisms play an important role in the pathophysiology of connective tissue formation in the epidural space. An analysis of experimental and clinical studies examining the effectiveness of various materials and drugs is presented. The authors present the current data on new therapeutic approaches to the prevention of postoperative epidural fibrosis. Topical, unresolved issues which necessitate further research on the pathophysiology of epidural fibrosis are indicated.
- 8 June 2021
- Published by Association of Spine Surgeons in Russian Journal of Spine Surgery (Khirurgiya Pozvonochnika)
- Vol. 18 (2) , 83-92
Open AccessThe use of various materials and drugs for the prevention of the development of postoperative lumbar epidural fibrosis: literature review
The paper is a review of the current literature data on the use of various materials and drugs for the prevention of the development of postoperative lumbar epidural fibrosis. Literature searches were performed in the Pubmed, Medline, EMBASE, Cochrane Library and eLibrary databases. The formation and growth of fibrous tissue in the epidural space, followed by tissue adhesion to the dura mater, is the leading cause of pain afferentation in the lumbar spine and/or lower extremities. Several molecular and cellular mechanisms play an important role in the pathophysiology of connective tissue formation in the epidural space. An analysis of experimental and clinical studies examining the effectiveness of various materials and drugs is presented. The authors present the current data on new therapeutic approaches to the prevention of postoperative epidural fibrosis. Topical, unresolved issues which necessitate further research on the pathophysiology of epidural fibrosis are indicated.