Wenhan Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wenhan Xie has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Guangning Wu
School of Electrical Engineering Southwest Jiaotong University Chengdu China
3 shared publicationsGuoqiang Gao
School of Electrical Engineering Southwest Jiaotong University Chengdu China
2 shared publicationsHaozi Zuo
College of Electrical Engineering, Southwest Jiaotong University , Chengdu 610031, China
2 shared publications- Wenfu Wei
Southwest Jiaotong University
2 shared publications - Zefeng Yang
Southwest Jiaotong University
2 shared publications Chuanjun Tu
College of Materials Science and Engineering Hunan Province Key Laboratory for Advanced Carbon Materials and Applied Technology Hunan University Changsha Hunan China
1 shared publication
Latest Publications
- Open Access
- 27 December 2021
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 7 (2) , 369-381
Characteristics of pantograph‐catenary arc under low air pressure and strong airflow
Pantograph‐catenary arc fault is the primary factor threatening the stability of the power transmission for high‐speed railway. The motion characteristics of the pantograph‐catenary arc under low air pressure and strong airflow is significantly different from the case under atmospheric pressure. In this paper, an experimental platform of pantograph‐catenary arc was built to investigate arc root position‐time and arc column longitudinal drift height‐time characteristic curves under different air pressures and airflow velocites. Via analysing the corresponding results, it can be found that there are different arc root–arc column traction mechanisms at different stages of arc development. The arcing time and arc root stagnation time under low air pressure are significantly longer than the case under atmospheric pressure, resulting in more serious electrode ablation. The arc column longitudinal drift velocity and height are greater with the increase of airflow velocity. Two typical irregular arc motion phenomena—arc root jumping and arc reignition are observed. To clarify the internal mechanism of the above phenomenon, a magnetohydrodynamics (MHD) model of the pantograph‐catenary arc was lauched, the influence mechanism of the pantograph‐catenary arc temperature and voltage are studied, and the physical process of arc temperature oscillation is analysed. The research results provide theoretical support for arc protection in high‐altitude areas.
- 27 December 2021
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 7 (2) , 369-381
Open AccessCharacteristics of pantograph‐catenary arc under low air pressure and strong airflow
Pantograph‐catenary arc fault is the primary factor threatening the stability of the power transmission for high‐speed railway. The motion characteristics of the pantograph‐catenary arc under low air pressure and strong airflow is significantly different from the case under atmospheric pressure. In this paper, an experimental platform of pantograph‐catenary arc was built to investigate arc root position‐time and arc column longitudinal drift height‐time characteristic curves under different air pressures and airflow velocites. Via analysing the corresponding results, it can be found that there are different arc root–arc column traction mechanisms at different stages of arc development. The arcing time and arc root stagnation time under low air pressure are significantly longer than the case under atmospheric pressure, resulting in more serious electrode ablation. The arc column longitudinal drift velocity and height are greater with the increase of airflow velocity. Two typical irregular arc motion phenomena—arc root jumping and arc reignition are observed. To clarify the internal mechanism of the above phenomenon, a magnetohydrodynamics (MHD) model of the pantograph‐catenary arc was lauched, the influence mechanism of the pantograph‐catenary arc temperature and voltage are studied, and the physical process of arc temperature oscillation is analysed. The research results provide theoretical support for arc protection in high‐altitude areas.
- 6 July 2021
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 130 (1) , 015102
Highly conductive graphite matrix/copper composites by a pressureless infiltration method
Graphite matrix/copper composites have found significant potential uses in numerous areas. Until now, a high ambient gas pressure has to be applied to overcome the non-wettability between the copper melt and graphite matrix, which has restricted the technological and economic efficiencies, as well as the composite performance. In this paper, we have proposed a pressureless infiltration strategy to realize the preparation of highly conductive graphite matrix/copper composites. A tungsten carbide network is first in situ constructed in the graphite matrix, transforming the capillary force from the resistance mode to the impetus mode. Results show that the contact angle of graphite/copper decreased from 138.5° to 23° due to the constructed tungsten carbide network. The composites exhibit good interfacial bonding, and the electrical conductivity reaches 15.1 × 105 S/m, far higher than the requirement of the industry standard.
- 6 July 2021
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 130 (1) , 015102
Highly conductive graphite matrix/copper composites by a pressureless infiltration method
Graphite matrix/copper composites have found significant potential uses in numerous areas. Until now, a high ambient gas pressure has to be applied to overcome the non-wettability between the copper melt and graphite matrix, which has restricted the technological and economic efficiencies, as well as the composite performance. In this paper, we have proposed a pressureless infiltration strategy to realize the preparation of highly conductive graphite matrix/copper composites. A tungsten carbide network is first in situ constructed in the graphite matrix, transforming the capillary force from the resistance mode to the impetus mode. Results show that the contact angle of graphite/copper decreased from 138.5° to 23° due to the constructed tungsten carbide network. The composites exhibit good interfacial bonding, and the electrical conductivity reaches 15.1 × 105 S/m, far higher than the requirement of the industry standard.
- Open Access
- 7 June 2021
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 6 (4) , 674-683
Study on the erosion characteristics of copper‐carbon electrode pairs by DC air arc
As common electric contact materials, copper‐carbon electrode pairs are widely used in the field of electric contact such as in high‐speed railways, motor collector rings and grounding brushes. They play a key role in energy transmission in the above‐mentioned systems. Arc erosion has become a key issue threatening system safety. In this work, a dedicated arc erosion platform was built to study the polarity effect of copper‐carbon electrode pairs. It was found that arc dynamics and electrodes erosion behaviours were significantly different under different polarities, which could be understood from the mechanism of heat transfer, cooling and electron emission of the electrode. Then, when the carbon material was used as an anode, the arc caused carbon transfer: the carbon material sublimated quickly due to electron condensation and thermal conduction and quickly condensed on the low‐temperature metal electrode, while the carbon material transfer could partly inhibit the oxidation of the cathode metal electrode. In addition, the rapid sublimation of the carbon material produced high‐temperature airflow, which would make the arc impedance fluctuate and cause the arc voltage to jump. Finally, the anode heat transfer and cathode cooling mechanism directly affected the material state, and the erosion of the anode material was more serious.
- 7 June 2021
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 6 (4) , 674-683
Open AccessStudy on the erosion characteristics of copper‐carbon electrode pairs by DC air arc
As common electric contact materials, copper‐carbon electrode pairs are widely used in the field of electric contact such as in high‐speed railways, motor collector rings and grounding brushes. They play a key role in energy transmission in the above‐mentioned systems. Arc erosion has become a key issue threatening system safety. In this work, a dedicated arc erosion platform was built to study the polarity effect of copper‐carbon electrode pairs. It was found that arc dynamics and electrodes erosion behaviours were significantly different under different polarities, which could be understood from the mechanism of heat transfer, cooling and electron emission of the electrode. Then, when the carbon material was used as an anode, the arc caused carbon transfer: the carbon material sublimated quickly due to electron condensation and thermal conduction and quickly condensed on the low‐temperature metal electrode, while the carbon material transfer could partly inhibit the oxidation of the cathode metal electrode. In addition, the rapid sublimation of the carbon material produced high‐temperature airflow, which would make the arc impedance fluctuate and cause the arc voltage to jump. Finally, the anode heat transfer and cathode cooling mechanism directly affected the material state, and the erosion of the anode material was more serious.