Daniel Augusto Cantane
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Daniel Augusto Cantane has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Fernando Marcos de Oliveira
Itaipu Parquetec, Foz do Iguaçu 85867-900, PR, Brazil
3 shared publications - Tales Gottlieb Jahn
Energy Management Center - GE.DT, Itaipu Parquetec, Foz do Iguaçu, Brazil
3 shared publications - Adalberto Teogenes Tavares Junior
PPGIES, UNILA, Foz do iguaçu, Brazil
2 shared publications - Angel Ambrocio Quispe
Itaipu Parquetec, Foz do Iguaçu 85867-900, PR, Brazil
2 shared publications - Carina Bonavigo Jakubiu
Itaipu Parquetec, Foz do Iguaçu 85867-900, PR, Brazil
2 shared publications - Filipe Tavares Carneiro
Itaipu Parquetec, Foz do Iguaçu 85867-900, PR, Brazil
2 shared publications
Latest Publications
- Open Access
- 10 November 2026
- Published by Springer Nature in Journal of Solid State Electrochemistry
- p. 1-13
Koutecký-Levich analysis of the hydrogen evolution reaction on commercial Ni 201 and Ni-based alloy in alkaline media
- 10 November 2026
- Published by Springer Nature in Journal of Solid State Electrochemistry
- p. 1-13
Open AccessKoutecký-Levich analysis of the hydrogen evolution reaction on commercial Ni 201 and Ni-based alloy in alkaline media
- Open Access
Hydrogen Production Plant Retrofit for Green H2: Experimental Validation of a High-Efficiency Retrofit of an Alkaline Hydrogen Plant Using an Isolated DC Microgrid
Given the climate change observed in the past few decades, sustainable development and the use of renewable energy sources are urgent. In this scenario, hydrogen production through electrolyzers is a promising renewable source and energy vector because of its ultralow greenhouse emissions and high energy content. Hydrogen can be used in a variety of applications, from transportation to electricity generation, contributing to the diversification of the energy matrix. In this context, this paper presents an autonomous isolated DC microgrid system for generating and storing electrical energy to be exclusively used for feeding an electrolyzer hydrogen production plant, which has been retrofitted for green hydrogen production. Experimental verification was performed at Itaipu Parquetec, which consists of an alkaline electrolysis unit directly integrated with a battery energy storage system and renewable sources (e.g., photovoltaic and wind) by using an isolated DC microgrid concept based on DC/DC and AC/DC converters. Experimental results revealed that the new electrolyzer DC microgrid increases the system’s overall efficiency in comparison to the legacy thyristor-based power supply system by 26%, and it autonomously controls the energy supply to the electrolyzer under optimized conditions with an extremely low output current ripple. Another advantage of the proposed DC microgrid is its ability to properly manage the startup and shutdown process of the electrolyzer plant under power generation outages. This paper is the result of activities carried out under the R&D project of ANEEL program No. PD-10381-0221/2021, entitled “Multiport DC-DC Converter and IoT System for Intelligent Energy Management”, which was conducted in partnership with CTG-Brazil.
Open AccessHydrogen Production Plant Retrofit for Green H2: Experimental Validation of a High-Efficiency Retrofit of an Alkaline Hydrogen Plant Using an Isolated DC Microgrid
Given the climate change observed in the past few decades, sustainable development and the use of renewable energy sources are urgent. In this scenario, hydrogen production through electrolyzers is a promising renewable source and energy vector because of its ultralow greenhouse emissions and high energy content. Hydrogen can be used in a variety of applications, from transportation to electricity generation, contributing to the diversification of the energy matrix. In this context, this paper presents an autonomous isolated DC microgrid system for generating and storing electrical energy to be exclusively used for feeding an electrolyzer hydrogen production plant, which has been retrofitted for green hydrogen production. Experimental verification was performed at Itaipu Parquetec, which consists of an alkaline electrolysis unit directly integrated with a battery energy storage system and renewable sources (e.g., photovoltaic and wind) by using an isolated DC microgrid concept based on DC/DC and AC/DC converters. Experimental results revealed that the new electrolyzer DC microgrid increases the system’s overall efficiency in comparison to the legacy thyristor-based power supply system by 26%, and it autonomously controls the energy supply to the electrolyzer under optimized conditions with an extremely low output current ripple. Another advantage of the proposed DC microgrid is its ability to properly manage the startup and shutdown process of the electrolyzer plant under power generation outages. This paper is the result of activities carried out under the R&D project of ANEEL program No. PD-10381-0221/2021, entitled “Multiport DC-DC Converter and IoT System for Intelligent Energy Management”, which was conducted in partnership with CTG-Brazil.
- Open Access
- 25 June 2025
- Published by MDPI AG in Preprints.org
Hydrogen Production Plant Retrofit Towards Green H2: an Isolated Microgrid Highly Integrated with Battery Storage, Wind and Solar Sources
Given the climate change being observed in the past few decades, sustainable development and the use of renewable energy sources are urgent. In this scenario, hydrogen production through electrolyzers is a promising renewable source and energy vector because of its ultralow greenhouse emissions and high energy content. Hydrogen can be used in a variety of applications, from transportation to electricity generation, contributing to the diversification of the energy matrix. In this context, this paper presents an autonomous isolated microgrid system for generating and storing electrical energy, to be exclusively used for feeding an electrolyzer hydrogen production plant, which has been retrofitted toward green hydrogen production. The experimental verification was performed at Itaipu Parquetec, which consists of an alkaline electrolysis unit directly integrated with a battery energy storage system and renewable sources (e.g., photovoltaic and wind) by using an isolated DC microgrid concept based on DC-DC and AC-DC converters. Experimental results revealed that the new electrolyzer DC-DC converter increases the system’s overall efficiency in comparison to the legacy thyristor-based power supply system, and autonomously control the energy supply to the electrolyzer under optimized conditions with extremely low output current ripple. Another advantage of the proposed DC microgrid is its ability to proper manage the startup and shutdown process of the electrolyzer plant under generation outages. This paper is the result of activities carried out under the R&D project of the ANEEL program No. PD-10381-0221/2021, entitled Multiport DC-DC Converter and IoT System for Intelligent Energy Management, which was conducted in partnership with CTG-Brasil.
- 25 June 2025
- Published by MDPI AG in Preprints.org
Open AccessHydrogen Production Plant Retrofit Towards Green H2: an Isolated Microgrid Highly Integrated with Battery Storage, Wind and Solar Sources
Given the climate change being observed in the past few decades, sustainable development and the use of renewable energy sources are urgent. In this scenario, hydrogen production through electrolyzers is a promising renewable source and energy vector because of its ultralow greenhouse emissions and high energy content. Hydrogen can be used in a variety of applications, from transportation to electricity generation, contributing to the diversification of the energy matrix. In this context, this paper presents an autonomous isolated microgrid system for generating and storing electrical energy, to be exclusively used for feeding an electrolyzer hydrogen production plant, which has been retrofitted toward green hydrogen production. The experimental verification was performed at Itaipu Parquetec, which consists of an alkaline electrolysis unit directly integrated with a battery energy storage system and renewable sources (e.g., photovoltaic and wind) by using an isolated DC microgrid concept based on DC-DC and AC-DC converters. Experimental results revealed that the new electrolyzer DC-DC converter increases the system’s overall efficiency in comparison to the legacy thyristor-based power supply system, and autonomously control the energy supply to the electrolyzer under optimized conditions with extremely low output current ripple. Another advantage of the proposed DC microgrid is its ability to proper manage the startup and shutdown process of the electrolyzer plant under generation outages. This paper is the result of activities carried out under the R&D project of the ANEEL program No. PD-10381-0221/2021, entitled Multiport DC-DC Converter and IoT System for Intelligent Energy Management, which was conducted in partnership with CTG-Brasil.
- Open Access
FBM-CSoC Control and Management System for Multi-Port Converter Applied in Hybrid Energy Storage System Used in Microgrid
Several management and control techniques for hybrid energy storage systems (HESS) with batteries and supercapacitors are presented in the literature applied to microgrids (MGs). The filter-based control strategy for defining the control loop actuation is one of the most widely used approaches with satisfactory performance. Variations of the Filter-Based Method (FBM) method are proposed to improve the control efficiency of the HESS under load disturbance and intermittent generator sources. However, not enough attention has been paid to the impacts of MG on the operational performance of batteries, despite the fact that they represent a non-negligible percentage of the total cost of MGs. In this paper, a control strategy called FBM-CSoC is proposed that focuses primarily on mitigating battery safety and degradation issues. The control strategy proposes a distribution of the charging and discharging current in a weighted proportional way to the normalized rated capacity and current state of charge (SoC) of each battery in the MG. This control strategy favors both the reduction of the internal temperature variation of the cells and the possibility of them operating in overcharging or over-discharging conditions. A comparative case study between the traditional FBM method and the FBM-CSoC, by means of numerical simulations, demonstrated that the load distribution occurs satisfactorily in energy storage systems. Finally, the FBM-CSoC method can be flexibly used for different types of battery technology and/or batteries with different SoCs integrated with supercapacitors.
Open AccessFBM-CSoC Control and Management System for Multi-Port Converter Applied in Hybrid Energy Storage System Used in Microgrid
Several management and control techniques for hybrid energy storage systems (HESS) with batteries and supercapacitors are presented in the literature applied to microgrids (MGs). The filter-based control strategy for defining the control loop actuation is one of the most widely used approaches with satisfactory performance. Variations of the Filter-Based Method (FBM) method are proposed to improve the control efficiency of the HESS under load disturbance and intermittent generator sources. However, not enough attention has been paid to the impacts of MG on the operational performance of batteries, despite the fact that they represent a non-negligible percentage of the total cost of MGs. In this paper, a control strategy called FBM-CSoC is proposed that focuses primarily on mitigating battery safety and degradation issues. The control strategy proposes a distribution of the charging and discharging current in a weighted proportional way to the normalized rated capacity and current state of charge (SoC) of each battery in the MG. This control strategy favors both the reduction of the internal temperature variation of the cells and the possibility of them operating in overcharging or over-discharging conditions. A comparative case study between the traditional FBM method and the FBM-CSoC, by means of numerical simulations, demonstrated that the load distribution occurs satisfactorily in energy storage systems. Finally, the FBM-CSoC method can be flexibly used for different types of battery technology and/or batteries with different SoCs integrated with supercapacitors.
- Open Access
Comparative Analysis of Degradation Assessment of Battery Energy Storage Systems in PV Smoothing Application
Photovoltaic (PV) generation depends on the availability of solar resources, being directly influenced by the variation in irradiance due to the presence of clouds over the PV panels, causing a variation in the power output. The use of battery energy storage systems integrated with the PV showed to be a technically feasible solution to mitigate these power output fluctuations within the maximum ramp limit. Most articles reported in the literature on smoothing PV power output, by coupling with battery degradation as performance indicators of the control strategy, used the event-oriented model that considers only the number of cycles and depth of discharge. This paper presents on the comparative analysis of two approaches to battery degradation models, an event-oriented model based on the Rainflow counting and a semiempirical model, and applies to photovoltaic power smoothing by using a wide range of restrictions and installed PV plant capacities. The semi-empirical degradation model revealed higher battery degradation for all simulated cases. For Strategy 2, the order was 50% higher than the event-oriented model, probably due to severe DR and RR, which increases the stress on the battery. For Strategy 1, the difference was greater, between 100% and 300%. The event-based model indicated that Strategy 1 implied less battery degradation, but the semi-empirical model indicated the opposite. Considering that the semi-empirical model considers more parameters of degradation, the fact that Strategy 2 implies less degradation is more reliable. Moreover, the result obtained by the SimSES model corroborates that the accelerated lithium cell battery degradation takes place, as the operation is at high SoC. Maintaining Ebat, reference is SoC 80% decreased the degradation in at least 25% with respect to degradation, maintaining Ebat, reference is SoC 100%. For this, Ebat, reference of the SoC control, can be designed to avoid operating under a high load state. The results demonstrated that choosing a simplified degradation model approach can lead to an error in the conclusion of which strategies are the best since calendar life effects are very important in the application of PV power smoothing.
Open AccessComparative Analysis of Degradation Assessment of Battery Energy Storage Systems in PV Smoothing Application
Photovoltaic (PV) generation depends on the availability of solar resources, being directly influenced by the variation in irradiance due to the presence of clouds over the PV panels, causing a variation in the power output. The use of battery energy storage systems integrated with the PV showed to be a technically feasible solution to mitigate these power output fluctuations within the maximum ramp limit. Most articles reported in the literature on smoothing PV power output, by coupling with battery degradation as performance indicators of the control strategy, used the event-oriented model that considers only the number of cycles and depth of discharge. This paper presents on the comparative analysis of two approaches to battery degradation models, an event-oriented model based on the Rainflow counting and a semiempirical model, and applies to photovoltaic power smoothing by using a wide range of restrictions and installed PV plant capacities. The semi-empirical degradation model revealed higher battery degradation for all simulated cases. For Strategy 2, the order was 50% higher than the event-oriented model, probably due to severe DR and RR, which increases the stress on the battery. For Strategy 1, the difference was greater, between 100% and 300%. The event-based model indicated that Strategy 1 implied less battery degradation, but the semi-empirical model indicated the opposite. Considering that the semi-empirical model considers more parameters of degradation, the fact that Strategy 2 implies less degradation is more reliable. Moreover, the result obtained by the SimSES model corroborates that the accelerated lithium cell battery degradation takes place, as the operation is at high SoC. Maintaining Ebat, reference is SoC 80% decreased the degradation in at least 25% with respect to degradation, maintaining Ebat, reference is SoC 100%. For this, Ebat, reference of the SoC control, can be designed to avoid operating under a high load state. The results demonstrated that choosing a simplified degradation model approach can lead to an error in the conclusion of which strategies are the best since calendar life effects are very important in the application of PV power smoothing.