Vijay S. Kale
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vijay S. Kale has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Prashant P. Bedekar
10 shared publicationsSudhir R. Bhide
10 shared publications- Srinivas Nagaballi
Department of Electrical Engineering, Visvesvaraya National Institute of Technology, Nagpur, Maharashtra, India
6 shared publications - Arvind Ramnarayan Singh
Department of Electrical Engineering, School of Physics and Electronic Engineering, Hanjiang Normal University, Shiyan, China
3 shared publications Nita R. Patne
3 shared publicationsG. Vamsi Krishna
Electrical & Electronics Department, MIC College of Technology, Vijayawada, India
2 shared publications
Latest Publications
- Open Access
- 16 March 2024
- Published by Association for Computing Machinery (ACM)
- p. 195-202
A Combined Data Mining and Ensembled Machine Learning based Solution for High Impedance Fault Detection in Distribution Systems
Detection of the High Impedance Fault (HIF) has been a problem of research for decades due to its randomness and inability to cause a sufficient disturbance. In the present work, Data Mining and Ensembled Machine Learning (EML) are used in conjunction to detect HIF in the distribution network. The search for the HIFs in space of electrical parameters is curtailed using K-means clustering for the data mining algorithm. EML consisting of a Support Vector Machine (SVM) and Decision Tree (DT) is hence deployed to detect HIF. The data-driven algorithm is adaptive and hence improves detection accuracy in earlier stages of HIF evolution over time. The article also describes tuning strategies of EML algorithms with the objective of minimizing false HIF detection. The offline synthetic data for EML is generated from MATLAB Simulink. Power distribution line parameters are considered for the data generation.
- 16 March 2024
- Published by Association for Computing Machinery (ACM)
- p. 195-202
Open AccessA Combined Data Mining and Ensembled Machine Learning based Solution for High Impedance Fault Detection in Distribution Systems
Detection of the High Impedance Fault (HIF) has been a problem of research for decades due to its randomness and inability to cause a sufficient disturbance. In the present work, Data Mining and Ensembled Machine Learning (EML) are used in conjunction to detect HIF in the distribution network. The search for the HIFs in space of electrical parameters is curtailed using K-means clustering for the data mining algorithm. EML consisting of a Support Vector Machine (SVM) and Decision Tree (DT) is hence deployed to detect HIF. The data-driven algorithm is adaptive and hence improves detection accuracy in earlier stages of HIF evolution over time. The article also describes tuning strategies of EML algorithms with the objective of minimizing false HIF detection. The offline synthetic data for EML is generated from MATLAB Simulink. Power distribution line parameters are considered for the data generation.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Techno-Economic Issues with Increasing DG Penetration level in Sub-Transmission System
The increasing interest in utilizing Distributed Generation (DG) in transmission system is due to rise in energy demand, restriction in new transmission lines, deregulated power and utility limitations. Introduction DG into the electrical network can improve its performance technically. Both DG placement and its penetration level become critical issue for both utility and DG owners. This paper presents the extent to which DG effect the power losses depending on the type of DG, its penetration level (PL) and its optimal location. In this paper, optimal DG placement and sizing in electrical network is found by using a Directed Bee Colony (DBC) optimization algorithm. The objective is to reduce the power losses and enhance voltage profile of the electrical system. The effectiveness of the DBC had been tested on IEEE 14-bus sub-transmission system and is compared with results obtained with Particle Swarm Optimization (PSO) method. As the PL of 55-60% and 70-75% is achieved the real and reactive power losses begin to increase respectively for DGs of type-2 in the electrical system. It is also observed that the net saving cost due to DG placement is beneficial up to 65% PL of DG.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Techno-Economic Issues with Increasing DG Penetration level in Sub-Transmission System
The increasing interest in utilizing Distributed Generation (DG) in transmission system is due to rise in energy demand, restriction in new transmission lines, deregulated power and utility limitations. Introduction DG into the electrical network can improve its performance technically. Both DG placement and its penetration level become critical issue for both utility and DG owners. This paper presents the extent to which DG effect the power losses depending on the type of DG, its penetration level (PL) and its optimal location. In this paper, optimal DG placement and sizing in electrical network is found by using a Directed Bee Colony (DBC) optimization algorithm. The objective is to reduce the power losses and enhance voltage profile of the electrical system. The effectiveness of the DBC had been tested on IEEE 14-bus sub-transmission system and is compared with results obtained with Particle Swarm Optimization (PSO) method. As the PL of 55-60% and 70-75% is achieved the real and reactive power losses begin to increase respectively for DGs of type-2 in the electrical system. It is also observed that the net saving cost due to DG placement is beneficial up to 65% PL of DG.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 491-496
The Technical Impact of Increase in Penetration Level of DG Technologies on Power System
Increasing penetration level of Distribution Generation (DG) in power system have been attracted attention of researchers in recent times. Utilities are moving towards DG integration into the system, to meet increase in load demand, to reduce system losses and due to concern about environmental effects etc. Integration of DG technologies in power system have technical as well as economical benefits. Technical impact of DG integration depends on the type of DG technology, penetration level and the location at which it is placed in the system. In this paper, the effect of increasing penetration level of different types of DGs on power loss and voltage profile are analysed on IEEE 14-bus test system. The simulation is carried out using MATLAB software. Newton Raphson method have been used for the load flow study and analytical method is used to find out optimal location and sizing of DGs. The simulation results show that there is significant reduction in power losses and improvement in voltage profile with the utilization of DG technologies in the power system. However, as the penetration level increase to the power losses begins to increase showing bathtub curve.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 491-496
The Technical Impact of Increase in Penetration Level of DG Technologies on Power System
Increasing penetration level of Distribution Generation (DG) in power system have been attracted attention of researchers in recent times. Utilities are moving towards DG integration into the system, to meet increase in load demand, to reduce system losses and due to concern about environmental effects etc. Integration of DG technologies in power system have technical as well as economical benefits. Technical impact of DG integration depends on the type of DG technology, penetration level and the location at which it is placed in the system. In this paper, the effect of increasing penetration level of different types of DGs on power loss and voltage profile are analysed on IEEE 14-bus test system. The simulation is carried out using MATLAB software. Newton Raphson method have been used for the load flow study and analytical method is used to find out optimal location and sizing of DGs. The simulation results show that there is significant reduction in power losses and improvement in voltage profile with the utilization of DG technologies in the power system. However, as the penetration level increase to the power losses begins to increase showing bathtub curve.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 272-275
A Hybrid Fuzzy and PSO based Optimum Placement and Sizing of DG in Radial Distribution System
The power system problems such as power loss and voltage regulation in Radial Distribution System (RDS) can be solved by the integration of the Distributed Generation (DG) in the RDS. The best location and sizing of DG is very challenging concern for maximizing the benefits. Inappropriate placement and capacity of DG may adverse the effect of DG benefits. The artificial intelligence based optimization techniques such as fuzzy, Genetic Algorithm (GA), Particle Swarm optimization (PSO) are very helpful to solve such problems. The objective of this paper is to find optimal location and sizing of DG to minimize the active and reactive power losses and to improve voltage profile of the RDS. In this paper, optimum location is determined by fuzzy system and PSO is used to design the optimal size of DG for standard IEEE 33-bus radial distribution test system.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 272-275
A Hybrid Fuzzy and PSO based Optimum Placement and Sizing of DG in Radial Distribution System
The power system problems such as power loss and voltage regulation in Radial Distribution System (RDS) can be solved by the integration of the Distributed Generation (DG) in the RDS. The best location and sizing of DG is very challenging concern for maximizing the benefits. Inappropriate placement and capacity of DG may adverse the effect of DG benefits. The artificial intelligence based optimization techniques such as fuzzy, Genetic Algorithm (GA), Particle Swarm optimization (PSO) are very helpful to solve such problems. The objective of this paper is to find optimal location and sizing of DG to minimize the active and reactive power losses and to improve voltage profile of the RDS. In this paper, optimum location is determined by fuzzy system and PSO is used to design the optimal size of DG for standard IEEE 33-bus radial distribution test system.
- 6 May 2018
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 28 (11) , e2615
On the significance of the plug setting in optimal time coordination of directional overcurrent relays
- 6 May 2018
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 28 (11) , e2615
On the significance of the plug setting in optimal time coordination of directional overcurrent relays
- 1 February 2018
- Published by Elsevier in Measurement
- Vol. 116, 96-105
Synchronized measurement based an adaptive distance relaying scheme for STATCOM compensated transmission line
- 1 February 2018
- Published by Elsevier in Measurement
- Vol. 116, 96-105
Synchronized measurement based an adaptive distance relaying scheme for STATCOM compensated transmission line
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
MTLBO Algorithm for DG Placement in RDS to Improve Voltage Stability Index and Minimize Losses
The proportion of Distributed Generations (DGs) in distribution system has been increasing due to growing electrical energy demand, economic growth and environmental reasons. In distribution system, the challenging issue for obtaining positive benefits for system with DG integration is its allocation. In this paper, a relatively new optimization method named Modified Teaching Learning Based Optimization (MTLBO) method for DG allocation in Radial Distribution System (RDS) is presented. The multiobjective optimization problem is considered. The objectives include voltage stability and active power loss issues. The optimization problem solved using MTLBO algorithm was tested on IEEE 33-bus RDS to demonstrate its efficacy and simulation studies were carried out using MATLAB software. The results obtained using MTLBO algorithm are compared with those using Particle Swarm Optimization (PSO) and Genetic Algorithm (GA) techniques.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
MTLBO Algorithm for DG Placement in RDS to Improve Voltage Stability Index and Minimize Losses
The proportion of Distributed Generations (DGs) in distribution system has been increasing due to growing electrical energy demand, economic growth and environmental reasons. In distribution system, the challenging issue for obtaining positive benefits for system with DG integration is its allocation. In this paper, a relatively new optimization method named Modified Teaching Learning Based Optimization (MTLBO) method for DG allocation in Radial Distribution System (RDS) is presented. The multiobjective optimization problem is considered. The objectives include voltage stability and active power loss issues. The optimization problem solved using MTLBO algorithm was tested on IEEE 33-bus RDS to demonstrate its efficacy and simulation studies were carried out using MATLAB software. The results obtained using MTLBO algorithm are compared with those using Particle Swarm Optimization (PSO) and Genetic Algorithm (GA) techniques.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 302-306
Real power loss reduction in radial distribution system by integrating DGs using MTLBO algorithm
In today's scenario, the energy demand is increasing because of growing rate of urbanization, economic growth, increasing prosperity and rising per capita energy consumption. Operation and planning of wide-area power system network is becoming more complex, with the rise in electrical energy demand. Distributed Generation (DG) is cost effective and environment friendly solution to fulfill the increasing power demand. This paper presents optimal placement and sizing of DG using Modified Teaching Learning Based Optimization (MTLBO) algorithm in the Radial Distribution System (RDS). In this paper, the main aim is to reduce the real power loss. MTLBO algorithm was tested on IEEE 33-bus RDS to demonstrate its efficacy and simulation studies were carried out using MATLAB software. The results of the optimization problem solved using MTLBO method are compared with those obtained using analytical method and Particle Swarm Optimization (PSO) technique. MTLBO algorithm is found to be promising for the optimization problem considered.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 302-306
Real power loss reduction in radial distribution system by integrating DGs using MTLBO algorithm
In today's scenario, the energy demand is increasing because of growing rate of urbanization, economic growth, increasing prosperity and rising per capita energy consumption. Operation and planning of wide-area power system network is becoming more complex, with the rise in electrical energy demand. Distributed Generation (DG) is cost effective and environment friendly solution to fulfill the increasing power demand. This paper presents optimal placement and sizing of DG using Modified Teaching Learning Based Optimization (MTLBO) algorithm in the Radial Distribution System (RDS). In this paper, the main aim is to reduce the real power loss. MTLBO algorithm was tested on IEEE 33-bus RDS to demonstrate its efficacy and simulation studies were carried out using MATLAB software. The results of the optimization problem solved using MTLBO method are compared with those obtained using analytical method and Particle Swarm Optimization (PSO) technique. MTLBO algorithm is found to be promising for the optimization problem considered.
- Open Access
- 7 July 2017
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 11 (10) , 2586-2598
Digital impedance pilot relaying scheme for STATCOM compensated TL for fault phase classification with fault location
This study presents calculation of fundamental frequency‐based per phase digital impedance pilot relaying (DIPR) scheme for static synchronous compensator (STATCOM) compensated transmission line (TL) using two end synchronised measurement. DIPR involves computation of absolute value of ratio of estimated phasor sum of voltages to the phasor sum of currents of both ends. DIPR inherently differentiate between internal and external faults on the line. For all internal faults, computed value of DIPR ratio is equivalent to system and TL impedance value whereas for external faults, it is equal to line capacitance impedance value. This novel pilot relaying scheme is easy to set once the system parameters are estimated and has the ability to detect all types of faults and correctly classify faulty phase with mid‐point connected STATCOM on TL. This scheme is immune to effect of STATCOM compensation mode, level of injection and its dynamic response. Also it is not affected by line charging capacitive current and fault transient resistance. The fault distance is estimated using the STATCOM current injection information for various types of fault with high accuracy, considering maximum fault resistance of 20 Ω. Accuracy and effectiveness of this scheme is evaluated in EMTDC/PSCAD simulation for 230 kV, 300 km, mid‐point STATCOM compensated TL and in hardware setup with mid‐point STATCOM on 100 V supply voltage having 200 km TL in offline mode. Results bring out the robustness, reliability and superiority of proposed novel pilot relaying scheme with fault location algorithm.
- 7 July 2017
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 11 (10) , 2586-2598
Open AccessDigital impedance pilot relaying scheme for STATCOM compensated TL for fault phase classification with fault location
This study presents calculation of fundamental frequency‐based per phase digital impedance pilot relaying (DIPR) scheme for static synchronous compensator (STATCOM) compensated transmission line (TL) using two end synchronised measurement. DIPR involves computation of absolute value of ratio of estimated phasor sum of voltages to the phasor sum of currents of both ends. DIPR inherently differentiate between internal and external faults on the line. For all internal faults, computed value of DIPR ratio is equivalent to system and TL impedance value whereas for external faults, it is equal to line capacitance impedance value. This novel pilot relaying scheme is easy to set once the system parameters are estimated and has the ability to detect all types of faults and correctly classify faulty phase with mid‐point connected STATCOM on TL. This scheme is immune to effect of STATCOM compensation mode, level of injection and its dynamic response. Also it is not affected by line charging capacitive current and fault transient resistance. The fault distance is estimated using the STATCOM current injection information for various types of fault with high accuracy, considering maximum fault resistance of 20 Ω. Accuracy and effectiveness of this scheme is evaluated in EMTDC/PSCAD simulation for 230 kV, 300 km, mid‐point STATCOM compensated TL and in hardware setup with mid‐point STATCOM on 100 V supply voltage having 200 km TL in offline mode. Results bring out the robustness, reliability and superiority of proposed novel pilot relaying scheme with fault location algorithm.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Review of network technologies in intelligent power system
Communication infrastructure plays a crucial role in operation and construction of a smart grid (SG). The growing issue of power grid congestion and the increase in power disturbances have emphasized the need to enhance electrical power networks using Wide Area Monitoring, Protection and Control (WAMPAC). Operation and control of the power grid need efficient and robust communication network architecture. To upgrade the existing power grid with present technologies used, new wired and wireless technologies, which are emerging out need to be addressed. In this paper, an overview of smart grid communication architecture and a comparative survey of the available communication technologies for the smart grid are given. The paper provides the necessary input to researchers and engineers about the communication technologies available for the SG. It deals with various ways to enhance the potential of traditional transmission and distribution system within the smart grid.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Review of network technologies in intelligent power system
Communication infrastructure plays a crucial role in operation and construction of a smart grid (SG). The growing issue of power grid congestion and the increase in power disturbances have emphasized the need to enhance electrical power networks using Wide Area Monitoring, Protection and Control (WAMPAC). Operation and control of the power grid need efficient and robust communication network architecture. To upgrade the existing power grid with present technologies used, new wired and wireless technologies, which are emerging out need to be addressed. In this paper, an overview of smart grid communication architecture and a comparative survey of the available communication technologies for the smart grid are given. The paper provides the necessary input to researchers and engineers about the communication technologies available for the SG. It deals with various ways to enhance the potential of traditional transmission and distribution system within the smart grid.