Alexandr V. Rybka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alexandr V. Rybka has a total of 144 co-authors. Here are the top co-authors by number of shared publications:
- Vladimir E. Kutny
National Science Ctr. Kharkov Institute of Physics and Technology (Ukraine)
23 shared publications - Aleksey Pudov
Department of Physics, Colorado State University, Fort Collins, CO 80523, USA
11 shared publications - Alexandr A. Zakharchenko
National Science Ctr. Kharkov Institute of Physics and Technology (Ukraine)
9 shared publications - Petro Fochuk
Department of Chemistry and Food Expertise, Yuriy Fedkovych Chernivtsi National University, 2, Kotsjubynskyi St., 58012 Chernivtsi, Ukraine
9 shared publications A. E. Bolotnikov
Brookhaven National Laboratory, Upton, USA
8 shared publicationsR. B. James
Brookhaven National Laboratory, Upton, NY 11973-5000, USA
7 shared publications
Latest Publications
- Open Access
- 15 December 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 134 (23)
Simulation of thin-film detectors of ionizing radiation and thermal neutrons based on CdTe
The article is dedicated to the numerical simulations of thin-layer structures based on CdTe semiconductors, which can be fabricated by using low-cost technologies. Structures Mo/Au/CdS/CdTe/Au, and their modifications, with different thicknesses of the main layers are investigated. The possibility of creating a detector of ionizing radiation based on these structures, which has selective properties with respect to the radiation type, and very low operation voltage, is shown. The detection efficiencies of α-, β-, and γ-radiation in different energy ranges were calculated based on the obtained values of energy losses of ionizing particles, which are proportional to the output signal of the detector. The use of such detectors, together with a solid-state converter made of boron carbide containing either natural boron natB or boron enriched with the 10B isotope up to 95%, for the detection of thermal neutrons was also studied. It was shown that the structures could be used to create α-particle spectrometers, given that the CdTe thickness is tailored to the highest expected α-particle energy. Detectors with thin CdTe (1–5 μm) can be successfully used in the counting mode. For neutron detection, stacking multiple single structures into sandwich structures was proposed and investigated. In such a configuration, the detector qualities were markedly improved: the efficiency of neutron detection reached ∼60%, while the sensitivity to the background γ- and β-radiation was ∼100 times lower than that for neutrons. The very low sensitivity of the simulated neutron detectors to the neutron incidence angle was shown.
- 15 December 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 134 (23)
Open AccessSimulation of thin-film detectors of ionizing radiation and thermal neutrons based on CdTe
The article is dedicated to the numerical simulations of thin-layer structures based on CdTe semiconductors, which can be fabricated by using low-cost technologies. Structures Mo/Au/CdS/CdTe/Au, and their modifications, with different thicknesses of the main layers are investigated. The possibility of creating a detector of ionizing radiation based on these structures, which has selective properties with respect to the radiation type, and very low operation voltage, is shown. The detection efficiencies of α-, β-, and γ-radiation in different energy ranges were calculated based on the obtained values of energy losses of ionizing particles, which are proportional to the output signal of the detector. The use of such detectors, together with a solid-state converter made of boron carbide containing either natural boron natB or boron enriched with the 10B isotope up to 95%, for the detection of thermal neutrons was also studied. It was shown that the structures could be used to create α-particle spectrometers, given that the CdTe thickness is tailored to the highest expected α-particle energy. Detectors with thin CdTe (1–5 μm) can be successfully used in the counting mode. For neutron detection, stacking multiple single structures into sandwich structures was proposed and investigated. In such a configuration, the detector qualities were markedly improved: the efficiency of neutron detection reached ∼60%, while the sensitivity to the background γ- and β-radiation was ∼100 times lower than that for neutrons. The very low sensitivity of the simulated neutron detectors to the neutron incidence angle was shown.
- Open Access
- 12 October 2023
- Published by Problems of Atomic Science and Technology in Problems of Atomic Science and Technology
- No. 5,p. 146-151
PROPORTIONAL DETECTORS OF GAMMA-RADIATION BASED ON HIGH PURITY XENON GAS FOR RADIATION MONITORING
This article is dedicated to a detailed investigation of properties of a proportional counter based on the Xe+2%CH4 mixture. A setup for filling the detectors with high purity Xe gas and Xe-based gas mixtures was designed and made. An optimized design of the proportional counters was developed and investigated. The design parameters, such as the material and diameter of the anode, the number and material of the gas mixture inlets, composition and pressure of the gas were improved. The operating regimes of the proportional counters, as well as their thermal stability, were investigated.
- 12 October 2023
- Published by Problems of Atomic Science and Technology in Problems of Atomic Science and Technology
- No. 5,p. 146-151
Open AccessPROPORTIONAL DETECTORS OF GAMMA-RADIATION BASED ON HIGH PURITY XENON GAS FOR RADIATION MONITORING
This article is dedicated to a detailed investigation of properties of a proportional counter based on the Xe+2%CH4 mixture. A setup for filling the detectors with high purity Xe gas and Xe-based gas mixtures was designed and made. An optimized design of the proportional counters was developed and investigated. The design parameters, such as the material and diameter of the anode, the number and material of the gas mixture inlets, composition and pressure of the gas were improved. The operating regimes of the proportional counters, as well as their thermal stability, were investigated.
- 9 September 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 132 (10) , 104501
Radiation sensor based on thin-film CdTe/CdS device structure and its radiation resistance under high-intensity hydrogen plasma
In this work, the ability of CdTe/CdS thin-film device structures prepared by the hot-wall method to detect ionizing radiation was investigated. The samples were fabricated with a structure typical of CdTe/CdS-based solar cells and exhibit radiation sensitivity even without the application of an external voltage. This allows such structures to be used as low-voltage radiation sensors. An investigation of the radiation resistance of the structures, namely, the effect of irradiation with high-intensity hydrogen plasma H2+ on the crystal structure and performance, was carried out. It was shown that the device structures remained operational after two plasma pulses at an ion density of 2 × 1023 m−2 and an energy density of up to 0.2 MJ/m2. With further exposure to plasma, the device structures deteriorated, first, due to gradual sputtering off of the back contact, and, second, as a result of diffusion processes that occurred when the structures were heated to high temperatures, due to which the entire volume of the CdTe base layer got converted into a CdSxTe1−x solid solution.
- 9 September 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 132 (10) , 104501
Radiation sensor based on thin-film CdTe/CdS device structure and its radiation resistance under high-intensity hydrogen plasma
In this work, the ability of CdTe/CdS thin-film device structures prepared by the hot-wall method to detect ionizing radiation was investigated. The samples were fabricated with a structure typical of CdTe/CdS-based solar cells and exhibit radiation sensitivity even without the application of an external voltage. This allows such structures to be used as low-voltage radiation sensors. An investigation of the radiation resistance of the structures, namely, the effect of irradiation with high-intensity hydrogen plasma H2+ on the crystal structure and performance, was carried out. It was shown that the device structures remained operational after two plasma pulses at an ion density of 2 × 1023 m−2 and an energy density of up to 0.2 MJ/m2. With further exposure to plasma, the device structures deteriorated, first, due to gradual sputtering off of the back contact, and, second, as a result of diffusion processes that occurred when the structures were heated to high temperatures, due to which the entire volume of the CdTe base layer got converted into a CdSxTe1−x solid solution.
- 27 June 2020
- Published by Springer Nature
- p. 229-243
Hand-Held Gamma Detector Based on High-Pressure Xenon Gas: Determination of Charge Carrier Lifetime in Xe
- 27 June 2020
- Published by Springer Nature
- p. 229-243
Hand-Held Gamma Detector Based on High-Pressure Xenon Gas: Determination of Charge Carrier Lifetime in Xe
- 30 January 2020
- Published by Problems of Atomic Science and Technology
- p. 211-214
MINERAL INSULATORS FOR KOMPTON DETECTORS OF NEUTRONS WITH A METAL HAFNIUM EMITTER
One of the priority tasks of nuclear power industry is to increase the reliability and safety of nuclear power plants. In this regard, traditional detectors for measuring the neutron flux in the reactor core are being improved and new ones are developed. This work is dedicated to one of the tasks of creating a compton self-powered neutron detector, namely, the formation of an insulator of magnesium oxide on an emitter of metallic hafnium. The effect of three types of magnesium oxide of different purity and structural state, as well as annealing temperature on the electrical resistance of the insulator between the collector and the emitter of the detector, is studied. The detector prototypes were manufactured by filling with magnesium oxidepowders or by applying liquid-phase mixturesthereof.
- 30 January 2020
- Published by Problems of Atomic Science and Technology
- p. 211-214
MINERAL INSULATORS FOR KOMPTON DETECTORS OF NEUTRONS WITH A METAL HAFNIUM EMITTER
One of the priority tasks of nuclear power industry is to increase the reliability and safety of nuclear power plants. In this regard, traditional detectors for measuring the neutron flux in the reactor core are being improved and new ones are developed. This work is dedicated to one of the tasks of creating a compton self-powered neutron detector, namely, the formation of an insulator of magnesium oxide on an emitter of metallic hafnium. The effect of three types of magnesium oxide of different purity and structural state, as well as annealing temperature on the electrical resistance of the insulator between the collector and the emitter of the detector, is studied. The detector prototypes were manufactured by filling with magnesium oxidepowders or by applying liquid-phase mixturesthereof.
- Open Access
- 1 December 2019
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 51 (8) , 1964-1969
Radiation-induced transformation of Hafnium composition
- 1 December 2019
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 51 (8) , 1964-1969
Open AccessRadiation-induced transformation of Hafnium composition
- Open Access
- 25 September 2018
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) in Nuclear Physics and Atomic Energy
- Vol. 19 (3) , 237-243
Compton-emissive hafnium detector of neutrons for in-core monitoring
- 25 September 2018
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) in Nuclear Physics and Atomic Energy
- Vol. 19 (3) , 237-243
Open AccessCompton-emissive hafnium detector of neutrons for in-core monitoring
- 26 August 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9593, 959318
Response function of planar Cd(Zn)Te detectors to beta radiation
We investigated the response function of a planar Cd(Zn)Te detector designed for measurement of electron energy spectra and experimentally measured the response of Cd(Zn)Te detector to radiation of 90Sr/90Y reference radiation source. The obtained experimental spectra were compared with the spectra simulated by the Monte-Carlo method with Geant4 package. We managed to agree the simulated response with the experimental one using only two fitting parameters: products of mobility and average lifetime for electrons and holes. Thereby determined transport parameters of charge carriers were independently verified through the measurement of the positions of low energy 133Ba photopeaks of a reference gamma-ray source.
- 26 August 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9593, 959318
Response function of planar Cd(Zn)Te detectors to beta radiation
We investigated the response function of a planar Cd(Zn)Te detector designed for measurement of electron energy spectra and experimentally measured the response of Cd(Zn)Te detector to radiation of 90Sr/90Y reference radiation source. The obtained experimental spectra were compared with the spectra simulated by the Monte-Carlo method with Geant4 package. We managed to agree the simulated response with the experimental one using only two fitting parameters: products of mobility and average lifetime for electrons and holes. Thereby determined transport parameters of charge carriers were independently verified through the measurement of the positions of low energy 133Ba photopeaks of a reference gamma-ray source.