Mahesh Sakharam Bhadane
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mahesh Sakharam Bhadane has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Kishor H. Gavhane
Department of Physics, Savitribai Phule Pune University, Pune, 411007, India
8 shared publications - Sanjay D. Dhole
Low Energy Ion Accelerator Laboratory, Department of Physics, Savitribai Phule Pune University, Pune, India
8 shared publications S. S. Dahiwale
6 shared publications- Shailendra Satish Dahiwale
Department of physics, Savitribai Phule Pune University Pune Maharashtra, 411007, India
5 shared publications V. N. Bhoraskar
5 shared publicationsD. Kanjilal
4 shared publications
Latest Publications
- 4 November 2025
- Published by Elsevier in Journal of Physics and Chemistry of Solids
- Vol. 210
Probing the thermoluminescence properties of NaLi2PO4: Tb phosphors for low-dose radiation dosimetry applications
- 4 November 2025
- Published by Elsevier in Journal of Physics and Chemistry of Solids
- Vol. 210
Probing the thermoluminescence properties of NaLi2PO4: Tb phosphors for low-dose radiation dosimetry applications
- Open Access
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Thermoluminescence and Photoluminescence Properties of Nayf4 Doped with Tb3+, Eu3+, and Dy3+ Phosphors for Dosimetric Applications
Hexagonal phase sodium yttrium fluoride doped with lanthanide ions; NaYF4: Ln3+, Ln=Tb, Eu and Dy were synthesized via facile hydrothermal route. The photoluminescence studies showed green, red and blue emission lines corresponding to 5D4 → 7FJ (J = 6, 5, 4, 3), 5D0→7FJ (J=1, 2 and 4) and 4F9/2 to 6HJ (J=15/2 and 13/2) transitions characteristic of Tb3+ , Eu3+ and Dy3+ ions, respectively. The as-prepared samples were annealed at different temperatures from 500 ᵒC to 800 ᵒC for optimization of thermoluminescence glow curve and meanwhile the influence of thermal treatment on their structural, morphological, and photoluminescence properties were studied. The spherical-like morphology of NaYF4: Tb3+ phosphor changed to micro block like structures along with phase transformation from hexagonal phase to cubic phase were observed at higher annealing temperature around 800 °C. The photoluminescence intensity also varied at different annealing temperature. The systematic study by using different dopants and annealing temperatures were carried out to achieve high thermoluminescence (TL) efficiency and the most suitable TL dosimetric glow curve was obtained for NaYF4:0.5 % Tb3+ annealed at 800 °C, peaked at 194 °C. The NaYF4: Tb3+ phosphor showed a linear TL response in the range from 1 kGy to 25 kGy gamma dose. Since, the phosphor showed TL response at higher doses, this indicates that the NaYF4: Tb3+ is quite well suited for high dose measurements and respective applications. The phosphor exhibited negligible fading and good reproducibility feature. Trap level analysis and experimental determination of activation energy was carried out by using Tm –Tstop technique and Initial Rise Method (IRM). The trapping parameters of glow curves as trap depth/activation energy (E), order of kinetics (b), and frequency factor (s), were estimated by Chen’s glow Peak shape (PS) method and Glow Curve Deconvolution (GCD) method. The trapping parameters obtained by IRM, PS method and GCD method are in good agreement with each other. Henceforth, along with efficient photoluminescence properties, the NaYF4: Tb3+ phosphor exhibited favorable thermoluminescence dosimetric properties. Consequently, make them a potential phosphor material and promise to endow new opportunities into the radiation dosimetry applications such as environmental and food monitoring, space dosimetry, etc.
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessThermoluminescence and Photoluminescence Properties of Nayf4 Doped with Tb3+, Eu3+, and Dy3+ Phosphors for Dosimetric Applications
Hexagonal phase sodium yttrium fluoride doped with lanthanide ions; NaYF4: Ln3+, Ln=Tb, Eu and Dy were synthesized via facile hydrothermal route. The photoluminescence studies showed green, red and blue emission lines corresponding to 5D4 → 7FJ (J = 6, 5, 4, 3), 5D0→7FJ (J=1, 2 and 4) and 4F9/2 to 6HJ (J=15/2 and 13/2) transitions characteristic of Tb3+ , Eu3+ and Dy3+ ions, respectively. The as-prepared samples were annealed at different temperatures from 500 ᵒC to 800 ᵒC for optimization of thermoluminescence glow curve and meanwhile the influence of thermal treatment on their structural, morphological, and photoluminescence properties were studied. The spherical-like morphology of NaYF4: Tb3+ phosphor changed to micro block like structures along with phase transformation from hexagonal phase to cubic phase were observed at higher annealing temperature around 800 °C. The photoluminescence intensity also varied at different annealing temperature. The systematic study by using different dopants and annealing temperatures were carried out to achieve high thermoluminescence (TL) efficiency and the most suitable TL dosimetric glow curve was obtained for NaYF4:0.5 % Tb3+ annealed at 800 °C, peaked at 194 °C. The NaYF4: Tb3+ phosphor showed a linear TL response in the range from 1 kGy to 25 kGy gamma dose. Since, the phosphor showed TL response at higher doses, this indicates that the NaYF4: Tb3+ is quite well suited for high dose measurements and respective applications. The phosphor exhibited negligible fading and good reproducibility feature. Trap level analysis and experimental determination of activation energy was carried out by using Tm –Tstop technique and Initial Rise Method (IRM). The trapping parameters of glow curves as trap depth/activation energy (E), order of kinetics (b), and frequency factor (s), were estimated by Chen’s glow Peak shape (PS) method and Glow Curve Deconvolution (GCD) method. The trapping parameters obtained by IRM, PS method and GCD method are in good agreement with each other. Henceforth, along with efficient photoluminescence properties, the NaYF4: Tb3+ phosphor exhibited favorable thermoluminescence dosimetric properties. Consequently, make them a potential phosphor material and promise to endow new opportunities into the radiation dosimetry applications such as environmental and food monitoring, space dosimetry, etc.
- 1 March 2020
- Published by Elsevier in Journal of Alloys and Compounds
- Vol. 817
Tm-Tstop analysis and dosimetric properties of Ce doped BaB4O7 phosphor
- 1 March 2020
- Published by Elsevier in Journal of Alloys and Compounds
- Vol. 817
Tm-Tstop analysis and dosimetric properties of Ce doped BaB4O7 phosphor
- 1 May 2019
- Published by Elsevier in Journal of Luminescence
- Vol. 209, 316-320
TL properties of BaF2:Ce phosphor for high gamma ray dosimetry
- 1 May 2019
- Published by Elsevier in Journal of Luminescence
- Vol. 209, 316-320
TL properties of BaF2:Ce phosphor for high gamma ray dosimetry
- 17 January 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (5) , 055901
Structural, morphological and 6 MeV energy electron dosimetric properties of Cu doped SnO2 phosphor
Cu doped SnO2 (SnO2:Cu) nano phosphor (NP) was successfully synthesized by one-step simple hydrothermal method and it was characterized by XRD (X-Ray Diffraction) for structural, FESEM (Field Emission Scanning Electron Microscopy) for morphological and EDS (Electron Dispersive Spectroscopy) for elemental analysis. NP was annealed at 700 oC for 2 hr and its crystallinity for tetragonal phase was confirmed through XRD. The crystallite size was ~10.39 nm for un-annealed and ~18.16 nm for annealed samples which has been calculated using Scherer equation. The particle size was estimated to be ~43 nm and the elemental composition of Sn, O, Cu was obtained by EDS. In addition, to study the dosimetric properties, the SnO2:Cu phosphors were irradiated with 6 MeV electron beam at fluences ranging from 10 x 1011 e/cm2 to 20 x 1012 e/cm2 which is equivalent to the 1.55 kGy to 31 kGy. The irradiated sample showed Thermoluminescence (TL) dosimetric glow peaks at 170 C, 263 C and 303 C. SnO2:Cu NP was found to be sensitive enough for energetic electrons. Further, it has been noticed that the TL dose response found sensitive upto 10 x 1012 e/cm2 (15.50 kGy) with fading of 5.1 % for 2 months. Hence, SnO2:Cu can be used for the measurement of electron doses.
- 17 January 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (5) , 055901
Structural, morphological and 6 MeV energy electron dosimetric properties of Cu doped SnO2 phosphor
Cu doped SnO2 (SnO2:Cu) nano phosphor (NP) was successfully synthesized by one-step simple hydrothermal method and it was characterized by XRD (X-Ray Diffraction) for structural, FESEM (Field Emission Scanning Electron Microscopy) for morphological and EDS (Electron Dispersive Spectroscopy) for elemental analysis. NP was annealed at 700 oC for 2 hr and its crystallinity for tetragonal phase was confirmed through XRD. The crystallite size was ~10.39 nm for un-annealed and ~18.16 nm for annealed samples which has been calculated using Scherer equation. The particle size was estimated to be ~43 nm and the elemental composition of Sn, O, Cu was obtained by EDS. In addition, to study the dosimetric properties, the SnO2:Cu phosphors were irradiated with 6 MeV electron beam at fluences ranging from 10 x 1011 e/cm2 to 20 x 1012 e/cm2 which is equivalent to the 1.55 kGy to 31 kGy. The irradiated sample showed Thermoluminescence (TL) dosimetric glow peaks at 170 C, 263 C and 303 C. SnO2:Cu NP was found to be sensitive enough for energetic electrons. Further, it has been noticed that the TL dose response found sensitive upto 10 x 1012 e/cm2 (15.50 kGy) with fading of 5.1 % for 2 months. Hence, SnO2:Cu can be used for the measurement of electron doses.
- 1 January 2019
- Published by AIP Publishing
- Vol. 2115, 030177
A study on thermoluminescence dosimetric properties of CaMoO4:Cu nanophosphor
- 1 January 2019
- Published by AIP Publishing
- Vol. 2115, 030177
A study on thermoluminescence dosimetric properties of CaMoO4:Cu nanophosphor
- 17 December 2018
- Published by Taylor & Francis in Materials Technology
- Vol. 34 (6) , 324-335
Development of graphene-drug nanoparticle based supramolecular self assembled pH sensitive hydrogel as potential carrier for targeting MDR tuberculosis
The Mycobacterium tuberculosis (MTB) resides in mononuclear phagocytes (macrophages) hence selective targeting at the molecular level using Graphene Oxide (GO) Air Dried Hydrogel (ADH) is investigated in present investigation. The GO has capability to form supramolecular self assembly, due to π – π stacking and hydrogen bonding interactions between surface groups of GO and oppositely charged drug molecule in presence of water. The hydrogel was fabricated using GO and Para-aminosalicylic acid (PAS) in solution phase. The fabricated hydrogel was lyophilized to obtain air dried hydrogel (ADH). The ADH showed potent antimicrobial activity and in-vitro cytotoxicity against S. Aureus and E. Coli, and MCF −7 cells respectively. The Alamar blue assay demonstrated the invasive characteristics of ADH in MTB (H37Rv). From the results obtained so far we lead to conclude that ADH is more invasive compared to the equivalent amount of pure PAS.
- 17 December 2018
- Published by Taylor & Francis in Materials Technology
- Vol. 34 (6) , 324-335
Development of graphene-drug nanoparticle based supramolecular self assembled pH sensitive hydrogel as potential carrier for targeting MDR tuberculosis
The Mycobacterium tuberculosis (MTB) resides in mononuclear phagocytes (macrophages) hence selective targeting at the molecular level using Graphene Oxide (GO) Air Dried Hydrogel (ADH) is investigated in present investigation. The GO has capability to form supramolecular self assembly, due to π – π stacking and hydrogen bonding interactions between surface groups of GO and oppositely charged drug molecule in presence of water. The hydrogel was fabricated using GO and Para-aminosalicylic acid (PAS) in solution phase. The fabricated hydrogel was lyophilized to obtain air dried hydrogel (ADH). The ADH showed potent antimicrobial activity and in-vitro cytotoxicity against S. Aureus and E. Coli, and MCF −7 cells respectively. The Alamar blue assay demonstrated the invasive characteristics of ADH in MTB (H37Rv). From the results obtained so far we lead to conclude that ADH is more invasive compared to the equivalent amount of pure PAS.
- 18 April 2018
- Published by IGI Global Scientific Publishing
- p. 53-84
Phosphors for Various Dosimetry Applications Derived by Different Synthesis Routes
The chapter provides useful information about synthesis and characterization of dysprosium doped oxide and fluoride-based phosphors such as SrGd2O4, CaSO4, and CaF2. Various techniques (e.g., acid-recrystallization, chemical co-precipitation, and homogenous precipitation cum auto-combustion methods) were adopted to synthesize these phosphors for large-scale production. All the prepared phosphors were characterized by x-ray diffraction analysis, scanning electron microscopy, and transmission electron microscopy techniques. The thermoluminescence (TL) studies were performed after different irradiation sources such as gamma rays, thermal neutrons, and low energy ions (H, Ar, and N), respectively. Linear dose responses were observed in a wide range of doses for all the samples. Various trapping parameters, namely order of kinetics, activation energy, and frequency factors, were calculated by using computerized glow curve deconvolution (CGCD) method.
- 18 April 2018
- Published by IGI Global Scientific Publishing
- p. 53-84
Phosphors for Various Dosimetry Applications Derived by Different Synthesis Routes
The chapter provides useful information about synthesis and characterization of dysprosium doped oxide and fluoride-based phosphors such as SrGd2O4, CaSO4, and CaF2. Various techniques (e.g., acid-recrystallization, chemical co-precipitation, and homogenous precipitation cum auto-combustion methods) were adopted to synthesize these phosphors for large-scale production. All the prepared phosphors were characterized by x-ray diffraction analysis, scanning electron microscopy, and transmission electron microscopy techniques. The thermoluminescence (TL) studies were performed after different irradiation sources such as gamma rays, thermal neutrons, and low energy ions (H, Ar, and N), respectively. Linear dose responses were observed in a wide range of doses for all the samples. Various trapping parameters, namely order of kinetics, activation energy, and frequency factors, were calculated by using computerized glow curve deconvolution (CGCD) method.
- 2 December 2017
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 172 (11-12) , 931-951
Design and development of the 6–18 MeV electron beam system for medical and other applications
A system for the electron and photon therapy has been designed and developed at SAMEER, IITB, Mumbai. All the components of the system such as the 270° beam bending electromagnet, trim coils, magnet chamber, electron scattering foil, slits, applicators, etc., were designed and fabricated indigenously. The electrons of 6, 8, 9, 12, 15 and 18 MeV energies were provided by a linear accelerator, indigenously designed and made at SAMEER, IITB campus, Mumbai. The electron beam from the LINAC enters the magnet chamber horizontally, and after deflection and focusing in the 270° bending magnet, comes out of the exit port, and travels a straight path vertically down. After passing through the beryllium and tantalum scattering foils, the electron beam gets scattered and turns into a solid cone shape such that the diameter increases with the travel distance. The simulation results indicate that at the exit port of the 270° beam bending magnet, the electron beam has a divergence angle of ≤ 3 mrad and diameter ∼2–3 mm, and remains constant over 6–18 MeV. Normally, 6–18 MeV electrons are used for the electron therapy of skin and malignant cancer near the skin surface. On a plane at a distance of 100 cm from the scattering foils, the size of the electron beam could be varied from 10 cm × 10 cm to 25 cm × 25 cm using suitable applicators and slits. Different types of applicators were therefore designed and fabricated to provide required beam profile and dose of electrons to a patient. The 6 MeV cyclic electron accelerator called Race-Track Microtron of S. P. Pune University, Pune, was extensively used for studying the performances of the scattering foils, electron beam uniformity and radiation dose measurement. Different types of thermoluminescent dosimetry dosimeters were developed to measure dose in the range of 1–10kGy.
- 2 December 2017
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 172 (11-12) , 931-951
Design and development of the 6–18 MeV electron beam system for medical and other applications
A system for the electron and photon therapy has been designed and developed at SAMEER, IITB, Mumbai. All the components of the system such as the 270° beam bending electromagnet, trim coils, magnet chamber, electron scattering foil, slits, applicators, etc., were designed and fabricated indigenously. The electrons of 6, 8, 9, 12, 15 and 18 MeV energies were provided by a linear accelerator, indigenously designed and made at SAMEER, IITB campus, Mumbai. The electron beam from the LINAC enters the magnet chamber horizontally, and after deflection and focusing in the 270° bending magnet, comes out of the exit port, and travels a straight path vertically down. After passing through the beryllium and tantalum scattering foils, the electron beam gets scattered and turns into a solid cone shape such that the diameter increases with the travel distance. The simulation results indicate that at the exit port of the 270° beam bending magnet, the electron beam has a divergence angle of ≤ 3 mrad and diameter ∼2–3 mm, and remains constant over 6–18 MeV. Normally, 6–18 MeV electrons are used for the electron therapy of skin and malignant cancer near the skin surface. On a plane at a distance of 100 cm from the scattering foils, the size of the electron beam could be varied from 10 cm × 10 cm to 25 cm × 25 cm using suitable applicators and slits. Different types of applicators were therefore designed and fabricated to provide required beam profile and dose of electrons to a patient. The 6 MeV cyclic electron accelerator called Race-Track Microtron of S. P. Pune University, Pune, was extensively used for studying the performances of the scattering foils, electron beam uniformity and radiation dose measurement. Different types of thermoluminescent dosimetry dosimeters were developed to measure dose in the range of 1–10kGy.