SDSanjay D. Dhole

Sanjay D. Dhole

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sanjay D. Dhole has a total of 185 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • High‐Performance Hybrid Triboelectric Nanogenerator Integrated With Machine Learning for Human Activity Recognition

    by Navnath B. Phatangare, Amol M. Sonawane, Ambadas B. Phatangare, Vidya Dhamdhere, Shailendra S. Dahiwale, Sanjay D. Dhole

    Rapid advances in wearable electronics have increased demand for sustainable, self‐powered systems for real‐time human activity monitoring without an external power supply. Triboelectric nanogenerators (TENGs) address this need by harvesting mechanical energy and producing electrical signals for activity recognition. Here, we report a TENG‐based wearable sensing system integrating a hybrid Au–rGO/PDMS composite TENG into footwear for real‐time human activity recognition. Au nanoparticles were synthesized and simultaneously embedded on rGO nanosheets by a single‐step, in situ electron irradiation method. Characterization confirmed uniform Au nanoparticle distribution and strong Au–rGO interfacial contact, increasing charge‐trapping site density and the effective dielectric constant. Incorporating Au–rGO nanostructures in PDMS yields a flexible, high‐output TENG with enhanced performance from enlarged contact area, efficient interfacial charge transfer, dense charge trapping, and reduced charge recombination. The optimized device delivers a peak power density of 10.62 W/m 2 , charges a 33 µF capacitor in 210 s, and powers 104 light‐emitting diodes by tapping, achieving nearly fourfold higher output than pure PDMS. For activity recognition, voltage patterns from the footwear‐mounted TENG were processed into time‐ and amplitude‐domain features. Using machine learning, random forest classifier distinguished four activities, no movement, walking, running, and jumping with 90.4% accuracy (leave‐one‐subject‐out, three volunteers), confirming reliable recognition for Internet of Things and health monitoring.

  • Fabrication, testing, and clinical validation of an epoxy resin-based range shifter for pencil beam scanning proton therapy

    by Kantaram Darekar, Bhushankumar J Patil, Akshay Bhavke, Umesh Gayake, Vysakh Raveendran, Rohidas Punde, Prakash Shinde, Sanjay D Dhole, Chithambara Prabu Arunasalam, Lalit Chaudhari, et al.

    Background and Objectives. Range shifters (RS) are used to treat shallow targets in pencil beam scanning (PBS) proton therapy. This study aims to validate an in-house-fabricated epoxy resin RS through mechanical and dosimetric measurements, evaluate the Monte Carlo (MC) algorithm dose‐calculation accuracy of the treatment planning system (TPS) beam model incorporating this device, and assess its clinical feasibility for PBS proton therapy applications. Methods. The RS was fabricated using a silicone mould and machined to the required dimensions after curing. It was further evaluated through material characterization, mechanical testing, and dosimetric validation. Material characterization included determining the elemental composition, mass density, and mean excitation energy, which were incorporated into the beam modelling. Mechanical validation comprised dimensional verification, fitment testing, and assessment of material integrity and uniformity. Dosimetric validation was performed by measuring water-equivalent thickness (WET), range parameters, spot size, absolute dose, and fluence, and comparing them with TPS-MC calculations. Results. The cured epoxy resin exhibited normalized elemental composition of H:8.0%, C:65.0%, N:0.1%, and O:26.9%, with mass density 1.15 g cm −3 and mean excitation energy 72.5 eV. The fabricated RS matched the reference design within ±1 mm and demonstrated satisfactory fitment, reproducibility, material integrity and uniformity. The measured WET agreed with TPS estimated values within 0.06 g cm −2 , while differences in range parameters were Conclusion. This study presents the first comprehensive clinical validation and evaluation of cured solid epoxy resin as an RS material for PBS proton therapy applications. The in-house-fabricated, cured epoxy resin-based RS demonstrated excellent agreement with TPS-MC calculations and experimental measurements, establishing its clinical feasibility.

  • Neutron and Photon-Activation Reaction Cross Sections of 85Rb and 87Rb with Covariance Analysis

    by Rahul Kumar, G.T. Bholane, T.S. Ganesapandy, A.B. Khaire, Prashant Ghule, F.M.D. Attar, S.S. Dahiwale, V.N. Bhoraskar, S.D. Dhole

  • Role of nitrogen ion irradiation in modifying the properties of CZTS thin films for optoelectronic applications

    by Kalyani D. Tikote, Ashish B. Thorat, Pradyumna P. Waifalkar, Santosh K. Mahapatra, Shailendra S. Dahiwale, Sanjay D. Dhole

  • Tailoring CZTS thin film properties via low energy nitrogen ion irradiation

    by Kalyani D. Tikote, Ashish B. Thorat, Santosh K. Mahapatra, Shailendra S. Dahiwale, Sanjay D. Dhole

  • High performance Pd/g-C3N4/PDMS triboelectric nanogenerator for energy harvesting and machine learning-based human activity recognition

    by Amol Martin Sonawane, Ambadas Bajirao Phatangare, Puspen Mondal, Nitin Khantwal, Janardhanrao Gadde, Shailendra Satish Dahiwale, Vasant Nagesh Bhoraskar, Sanjay D Dhole

    The growing use of wearable Internet of Things (IoT) devices and smart sensors demands sustainable, self-powered systems for real-time human motion monitoring. Current sensing technologies rely on batteries, which have short lifespans, require frequent maintenance, and pose environmental risks. In this work, we present a battery-free motion sensing system using a triboelectric nanogenerator (TENG) embedded in footwear, with a Pd/g-C3N4/PDMS composite as the active layer. Two different sized Pd nanoparticles Pd nanoparticles were synthesized and simultaneously decorated on g-C3N4 nanosheets by the synchrotron X-ray irradiation. The characterization results indicate the formation of strong Pd-N and Pd-O bonds at the metal-semiconductor interface, which enhances charge transfer and storage by introducing additional trapping sites. High-performance and stable-output TENGs were fabricated using two types of Pd nanoparticle-decorated g-C3N4 nanosheets incorporated into PDMS insulating matrix. Compared to pristine PDMS and g-C3N4/PDMS-based TENGs, the Pd/g-C3N4/PDMS composite showed significantly better performance due to its higher contact surface area, surface charge density, and charge trapping centres. The optimized TENG achieved a peak power density of 9.6 W/m² and demonstrated practical utility by charging a 33 µF capacitor in 310 seconds and powering 102 LEDs through finger tapping. Additionally, we developed a machine learning based human motion detection system utilizing the electrical signals generated by the TENG. The TENG data was collected through Arduino microcontroller and processed using a random forest classifier to distinguish between four human activity states, no movement, walking, running, and jumping, enabling real-time monitoring. Experimental tests confirmed the 92 % accuracy in classifying each activity. This work combines TENG technology with ML to create an efficient, self-powered human motion detection system, offering potential applications in health monitoring, sports analytics, and smart wearable systems.

  • Thermoluminescence characteristics of Ca10K(PO4)7:Eu3+ phosphor for gamma radiation dosimetry

    by Sandhya B. Deshmukh, Preeti Padhye Kulkarni, Kishor H. Gavhane, Yogeshri Bagekari, Mahesh S. Bhadane, S. S. Dahiwale, S. D. Dhole


  • Exploring the thermoluminescence properties of terbium doped Mg5(BO3)3F phosphors for gamma dosimetry

    by Preeti Padhye Kulkarni, Kishor H. Gavhane, Sandhya Deshmukh, Mahesh Bhadane, S. S. Dahiwale, S. D. Dhole


  • Top Cited Papers

    Flexible Polyurethane - Tungsten oxide based composite for γ radiation shielding

    by Prashant G. Ghule, G.T. Bholane, Rahul Kumar, R.P. Joshi, S.S. Dahiwale, P.N. Shelke, S.D. Dhole


  • Open Access

    High performance triboelectric nanogenerator by synchrotron x-ray assisted Ru/g-C3N4 nanostructure incorporated into PDMS matrix

    by A. M. Sonawane, A. B. Phatangare, Balu R. Thombare, A. P. Jadhav, Puspen Mondal, Nitin Khantwal, S. S. Dahiwale, V. N. Bhoraskar, S. D. Dhole

    The integration of metal–semiconductor nanostructures is of significant interest to the advanced technology development. However, the synthesis methods for metal–semiconductor nanostructures are complicated and require multi-stage processing, which includes the separate synthesis of metallic and semiconductor nanostructures, controlling pH, and dedicated equipments. Herein, we report a one-step in situ synthesis and simultaneous embedding of Ru nanostructures on g-C3N4 nanosheets using the synchrotron x-ray irradiation method. The results indicate that Ru nanostructures were uniformly embedded within the g-C3N4 nanosheets, leading to the formation of Ru—O, RuO2, and Ru—O—Ru chemical bonds. Moreover, three distinct types of Ru nanostructures could be achieved by adjusting the x-ray dose. High-performance triboelectric nanogenerators (TENGs) were fabricated using these three types of Ru-embedded g-C3N4 nanosheets within a PDMS matrix. The output performance of these TENG devices was compared with that of PDMS and g-C3N4/PDMS TENGs. The improved dielectric constant contributes to the high performance of the TENG. The synthesized Ru/g-C3N4 nanostructures are notably significant due to increased contact surface area, charge distribution density, and the formation of a metal–semiconductor heterostructure system. These characteristics lead to high charge transfer rates, improved charge transport, and a higher density of charge trapping centers within the insulating matrix. Thus, we achieved a high TENG peak power density of 4.86 W/m2 during the contact separation process. The practical applicability of the TENG is also demonstrated. Furthermore, a 47 μF capacitor could be charged to 7.8 V in ∼400 s and can be used to continuously drive low power electronic gadgets.