Hanns-Erik Endres
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hanns-Erik Endres has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
- Jamila Boudaden
Fraunhofer EMFT, Research Institution for Microsystems and Solid State Technologies EMFT, Hansastraße 27d, D-80686 Munich, Germany
5 shared publications S. Drost
Fraunhofer Society
5 shared publications- Giorgio Sberveglieri
Department of Information Engineering, University of Brescia, via Branze 38, 25123 Brescia, Italy
3 shared publications - Ignaz Eisele
Fraunhofer Institute for Electronic Microsystems and Solid State Technologies EMFT, 80686 Munich, Germany
3 shared publications K. Bock
3 shared publicationsMathias Roth
3 shared publications
Latest Publications
- Open Access
- 20 April 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (5) , 261
Passivated Impedimetric Sensors for Immobilization-Free Pathogen Detection by Isothermal Amplification and Melt Curve Analysis
The ongoing SARS-CoV-2 pandemic demonstrates that the capacity of centralized clinical diagnosis laboratories represents a significant limiting factor in the global fight against the newly emerged virus. Scaling up these capacities also requires simple and robust methods for virus diagnosis to be easily driven by untrained personnel in a point-of-care (POC) environment. The use of impedance sensors reduces the complexity and costs of diagnostic instruments and increases automation of diagnosis processes. We present an impedance point-of-care system (IMP-POCS) that uses interdigitated electrodes surrounded by an integrated heating meander to monitor loop-mediated isothermal amplification (LAMP) and melt curve analysis (MCA) consecutively in a short time. MCA permits distinguishing false- from true-positive results and significantly raises the validity of pathogen detection. Conclusively, the herein-developed miniaturized total analysis system (µTAS) represents a powerful and promising tool for providing reliable, low-cost alternatives to standard clinical diagnosis.
- 20 April 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (5) , 261
Open AccessPassivated Impedimetric Sensors for Immobilization-Free Pathogen Detection by Isothermal Amplification and Melt Curve Analysis
The ongoing SARS-CoV-2 pandemic demonstrates that the capacity of centralized clinical diagnosis laboratories represents a significant limiting factor in the global fight against the newly emerged virus. Scaling up these capacities also requires simple and robust methods for virus diagnosis to be easily driven by untrained personnel in a point-of-care (POC) environment. The use of impedance sensors reduces the complexity and costs of diagnostic instruments and increases automation of diagnosis processes. We present an impedance point-of-care system (IMP-POCS) that uses interdigitated electrodes surrounded by an integrated heating meander to monitor loop-mediated isothermal amplification (LAMP) and melt curve analysis (MCA) consecutively in a short time. MCA permits distinguishing false- from true-positive results and significantly raises the validity of pathogen detection. Conclusively, the herein-developed miniaturized total analysis system (µTAS) represents a powerful and promising tool for providing reliable, low-cost alternatives to standard clinical diagnosis.
- Open Access
- 31 July 2019
- Published by MDPI AG in Nanomaterials
- Vol. 9 (8) , 1097
Towards Low Cost and Low Temperature Capacitive CO2 Sensors Based on Amine Functionalized Silica Nanoparticles
Hybrid materials based on inorganic particles and an organic polymer were developed and used as an efficient sensing material for carbon dioxide (CO2). The sensing material consists of fumed silica that is functionalized with an organic polymer, polyethylenimine, by means of the impregnation method. The organic polymer is effectively immobilized around the silica nanoparticles and confirmed by infrared spectroscopy. Thermogravimetric analysis proves the thermal stability of the sensing material. CO2 capacitive sensors operating at temperatures lower than 70 °C were fabricated by depositing a thin layer of hybrid sensing material on interdigitated gold electrodes. Impedance spectroscopy explored the sensing capability of the hybrid organic–inorganic material towards CO2 in the presence of different relative humidity levels, as well as its stability and reversibility. This strategy to couple organic and inorganic materials as a sensing layer for CO2 paves the way for the design of a low-cost CO2 sensor.
- 31 July 2019
- Published by MDPI AG in Nanomaterials
- Vol. 9 (8) , 1097
Open AccessTowards Low Cost and Low Temperature Capacitive CO2 Sensors Based on Amine Functionalized Silica Nanoparticles
Hybrid materials based on inorganic particles and an organic polymer were developed and used as an efficient sensing material for carbon dioxide (CO2). The sensing material consists of fumed silica that is functionalized with an organic polymer, polyethylenimine, by means of the impregnation method. The organic polymer is effectively immobilized around the silica nanoparticles and confirmed by infrared spectroscopy. Thermogravimetric analysis proves the thermal stability of the sensing material. CO2 capacitive sensors operating at temperatures lower than 70 °C were fabricated by depositing a thin layer of hybrid sensing material on interdigitated gold electrodes. Impedance spectroscopy explored the sensing capability of the hybrid organic–inorganic material towards CO2 in the presence of different relative humidity levels, as well as its stability and reversibility. This strategy to couple organic and inorganic materials as a sensing layer for CO2 paves the way for the design of a low-cost CO2 sensor.
- Open Access
- 30 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 812
Method to Study Water Diffusion into Polymers
We designed and realized a low cost relative humidity (RH) capacitive sensor having an interdigitated transducer coated with a cheap sensing material working at room temperature (polyimide). Thermally perturbed diffusion of water molecules into the polyimide layer is studied by heating the sensor locally and measuring the sensor capacitance change. The swelling and deswelling model is applied to determine the time constant of involved processes. This simple method, using an evaluation kit developed by our group, to measure the sensor capacitance and to study the diffusion process of water molecules into polyimide could be generalized to analyze the gas diffusion processes into polymer based sensing layer generally used in the field of gas chemical sensors.
- 30 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 812
Open AccessMethod to Study Water Diffusion into Polymers
We designed and realized a low cost relative humidity (RH) capacitive sensor having an interdigitated transducer coated with a cheap sensing material working at room temperature (polyimide). Thermally perturbed diffusion of water molecules into the polyimide layer is studied by heating the sensor locally and measuring the sensor capacitance change. The swelling and deswelling model is applied to determine the time constant of involved processes. This simple method, using an evaluation kit developed by our group, to measure the sensor capacitance and to study the diffusion process of water molecules into polyimide could be generalized to analyze the gas diffusion processes into polymer based sensing layer generally used in the field of gas chemical sensors.
- Top Cited PapersOpen Access
Polyimide-Based Capacitive Humidity Sensor
The development of humidity sensors with simple transduction principles attracts considerable interest by both scientific researchers and industrial companies. Capacitive humidity sensors, based on polyimide sensing material with different thickness and surface morphologies, are prepared. The surface morphology of the sensing layer is varied from flat to rough and then to nanostructure called nanograss by using an oxygen plasma etch process. The relative humidity (RH) sensor selectively responds to the presence of water vapor by a capacitance change. The interaction between polyimide and water molecules is studied by FTIR spectroscopy. The complete characterization of the prepared capacitive humidity sensor performance is realized using a gas mixing setup and an evaluation kit. A linear correlation is found between the measured capacitance and the RH level in the range of 5 to 85%. The morphology of the humidity sensing layer is revealed as an important parameter influencing the sensor performance. It is proved that a nanograss-like structure is the most effective for detecting RH, due to its rapid response and recovery times, which are comparable to or even better than the ones of commercial polymer-based sensors. This work demonstrates the readiness of the developed RH sensor technology for industrialization.
Top Cited PapersOpen AccessPolyimide-Based Capacitive Humidity Sensor
The development of humidity sensors with simple transduction principles attracts considerable interest by both scientific researchers and industrial companies. Capacitive humidity sensors, based on polyimide sensing material with different thickness and surface morphologies, are prepared. The surface morphology of the sensing layer is varied from flat to rough and then to nanostructure called nanograss by using an oxygen plasma etch process. The relative humidity (RH) sensor selectively responds to the presence of water vapor by a capacitance change. The interaction between polyimide and water molecules is studied by FTIR spectroscopy. The complete characterization of the prepared capacitive humidity sensor performance is realized using a gas mixing setup and an evaluation kit. A linear correlation is found between the measured capacitance and the RH level in the range of 5 to 85%. The morphology of the humidity sensing layer is revealed as an important parameter influencing the sensor performance. It is proved that a nanograss-like structure is the most effective for detecting RH, due to its rapid response and recovery times, which are comparable to or even better than the ones of commercial polymer-based sensors. This work demonstrates the readiness of the developed RH sensor technology for industrialization.
- 1 January 2018
- Published by AMA Service GmbH
- p. 298-299
GS8.2 - Smart Monitoring System for Air Quality Control with Capacitive Sensors
- 1 January 2018
- Published by AMA Service GmbH
- p. 298-299
GS8.2 - Smart Monitoring System for Air Quality Control with Capacitive Sensors
- Open Access
- 11 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 472
Capacitive CO2 Sensor
The objective of the present paper is to provide a concept for a chemical sensor having a small size, a low power consumption and a high reliability for sensing CO2 under different humidity levels at atmospheric pressure, while maintaining a long term stability under working conditions. A high temperature regeneration process of the sensing layer is unneeded to ensure a long term stability of the sensing material. This objective is achieved by using a hybrid organic-inorganic nanomaterial, consisting of inorganic nanoparticles functionalized with an amine-based polymer.
- 11 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 472
Open AccessCapacitive CO2 Sensor
The objective of the present paper is to provide a concept for a chemical sensor having a small size, a low power consumption and a high reliability for sensing CO2 under different humidity levels at atmospheric pressure, while maintaining a long term stability under working conditions. A high temperature regeneration process of the sensing layer is unneeded to ensure a long term stability of the sensing material. This objective is achieved by using a hybrid organic-inorganic nanomaterial, consisting of inorganic nanoparticles functionalized with an amine-based polymer.
- Open Access
- 1 January 2014
- Published by Elsevier in Procedia Engineering
- Vol. 87, 1234-1238
Simple Cost Effective and Network Compatible Readout for Capacitive and Resistive (Chemical) Sensors
- 1 January 2014
- Published by Elsevier in Procedia Engineering
- Vol. 87, 1234-1238
Open AccessSimple Cost Effective and Network Compatible Readout for Capacitive and Resistive (Chemical) Sensors
- 1 November 2013
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 202, 197-203
“Sensor-filter”—Intelligent micro filter system in foil technology
- 1 November 2013
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 202, 197-203
“Sensor-filter”—Intelligent micro filter system in foil technology
- Open Access
- 1 January 2012
- Published by Elsevier in Procedia Engineering
- Vol. 47, 212-215
“Sensor-Filter”–Intelligent Micro Filter System in Foil Technology
- 1 January 2012
- Published by Elsevier in Procedia Engineering
- Vol. 47, 212-215
Open Access“Sensor-Filter”–Intelligent Micro Filter System in Foil Technology
- 1 January 2012
- Published by AMA Service GmbH
- p. 531-532
6.2.2 Flexible sensors for an indoor air quality sensor system
- 1 January 2012
- Published by AMA Service GmbH
- p. 531-532
6.2.2 Flexible sensors for an indoor air quality sensor system