JJJin-Woo Jeong

Jin-Woo Jeong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jin-Woo Jeong has a total of 62 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Characterization of source coherence requirements for laboratory x-ray diffraction imaging

    by Sunghoon Choi, Sora Park, Jun-Tae Kang, Jin-Woo Jeong

    Young’s double-slit (YDS) fringe visibility provides a detector-accessible measure of spatial coherence, but implementing hard-X-ray YDS experiments with compact laboratory sources is fundamentally constrained by the coherence–flux trade-off imposed by spatial filtering. Here we present an end-to-end simulation framework that couples SHADOW3 ray statistics with WOFRY wave-optics propagation to evaluate detector-level interference patterns and feasibility metrics under partial coherence. Partial coherence is defined directly at the pinhole plane by discretizing the pinhole-filtered angular spectrum into a weighted angular-tilt ensemble, which is propagated through Fresnel (pinhole to slit) and Fraunhofer (slit to detector) operators with energy-conserving binning onto an oversampled detector grid. Across parameter sweeps of effective source size w (20–200 µm), source–pinhole distance S (3.0–4.7 m), pinhole diameter D (3–10 µm), pinhole–slit distance R (0.01–1.0 m), and Gaussian relative bandwidth σ BW (0.1–5%), we evaluate Michelson visibility V , detector-ROI photon counts N det , and a photon-statistics-aware figure of merit FOM = V 2 N det . To capture bandwidth-driven degradation not reflected by global visibility alone, we additionally introduce a longitudinal-coherence wash-out metric LC ratio . The resulting inverse-design maps reveal two distinct operating regimes. For larger sources ( w ∼200 µm), the feasible design space becomes visibility-limited, while smaller sources ( w ∼50 µm) operate primarily in a throughput-limited regime where performance improves monotonically with photon acceptance. Absolute photon statistics are anchored by calibrating the pinhole-transmitted flux to a published laboratory benchmark (≈5 × 10 3 ph/s through a 5 µm pinhole at 0.1% σ BW ), enabling exposure-time interpretation of the design maps in experimentally meaningful units. The framework therefore provides a quantitative guideline for selecting source filtering and propagation geometry in compact laboratory YDS measurements under realistic coherence and photon-statistics constraints.

  • Improved E-beam prediction in compact X-ray tube with ceramic charging

    by Sora Park, Yujung Ahn, Jun-Tae Kang, Sunghoon Choi, Ji-Hwan Yeon, Ensol Go, Yoon-Ho Song, Jin-Woo Jeong

  • Effects of Interfacial Electron Transport on Field Electron Emission from Carbon Nanotube Paste Emitters

    by Eunsol Go, Jae-Woo Kim, Jin-Woo Jeong, Sora Park, Jun-Tae Kang, Sunghoon Choi, Ji-Hwan Yeon, Yoon-Ho Song

    Field electron emission from carbon nanotubes (CNT) is preceded by the transport of electrons from the cathode metal to emission sites. Specifically, a supporting layer indispensable for adhesion of CNT paste emitters onto the cathode metal would impose a potential barrier, depending on its work function and interfacial electron transport behaviors. In this paper, we investigated the supporting layer of silicon carbide and nickel nanoparticles reacted onto a Kovar alloy (Fe-Ni-Co) cathode substrate, which has been adopted for reliable CNT paste emitters. The X-ray diffraction, X-ray photoelectron spectroscopy, ultraviolet photoelectron spectroscopy, and electrical conductivity measurements showed that the reaction of silicon carbide and nickel nanoparticles on the Kovar metal strongly depends upon the post-vacuum-annealing conditions and can be classified into two procedures of a diffusion-induced reaction (DIR) and a diffusion-limited reaction (DLR). The prolonged annealing at 750 °C for 5 h before the main annealing of the CNT paste emitters at 800 °C for 5 min led to the DIR that has enhanced the Ni silicide phase and a lower potential barrier for the interfacial electron transport, resulting in increased and weakly temperature-dependent field electron emission from the CNT paste emitters. On the other hand, the DLR with only the main anneal of the CNT paste emitters at 800 °C for 5 min gave rise to a higher potential barrier for the electron transport and so lower and strongly temperature-dependent field electron emission. From the results of the interfacial electron transport for the DIR and DLR mechanisms in the CNT paste emitters, we concluded that the ambient temperature dependency of field electron emission from CNT tips in the moderate range of up to 400 °C, still controversial, is mainly attributed to the supporting layer of the CNT emitter rather than its intrinsic electron emission.


  • Two applications of carbon nanotube paste emitters: nano-focus, and high-flux vacuum-sealed x-ray tubes

    by Jin-Woo Jeong, Jun-Tae Kang, Sora Park, Jae-Woo Kim, Ki Nam Yun, Eunsol Go, Jeong-Woong Lee, Hyojin Jeon, Yujung Ahn, Ji-Hwan Yeon, et al.

    The printed carbon nanotube (CNT) paste emitters were applied to two types of vacuum-sealed x-ray tubes for several hundred-nanometer-resolution non-destructive testing (NDT) and cone-beam breast computed tomography (CB-BCT) applications. A single dot CNT emitter of 200 micrometer in diameter was made for a small focal spot size of NDT imaging meanwhile a 983-dots array was for a high current of CB-BCT imaging. The electron beam emitted from the single dot emitter in the nano-focus x-ray tube is strongly focused to a small focal spot size of 1 micrometer or less in diameter by help of electrostatic and magnetic focusing lenses, and the 983 emitters produce a large field emission current over 200 mA with a moderate focal spot, tentatively applicable to CB-BCT imaging. The printed CNT emitters can be used for a variety of electron sources from several hundred-nanometer focusing to high-flux xray tubes.


  • Optimization of carbon nanotube paste emitter by controlling the size distribution of SiC nanofiller aggregates

    by Eunsol Go, Hyojin Jeon, Jeong-Woong Lee, Yoon-Ho Song, Jae-Woo Kim, Young Chul Choi, Sora Park, Jun-Tae Kang, Jin-Woo Jeong, Ji-Hwan Yeon, et al.

    We tried to improve field emission properties of carbon nanotube (CNT) paste emitters by controlling the size distribution of aggregated SiC fillers. The SiC fillers used as an adhesion promoter strongly affects the dispersion of CNT paste, determining uniformity and reproducibility of the field emitter. We found, to date, that the optimum distribution is about 1 μm of D50, the value of the particle diameter at 50% in cumulative distribution. The CNT emitters with the optimized paste showed uniform and reproducible emission performances along with high adhesion to the cathode. The improved paste formulation and emitter fabrication could lead to successful field emission devices and applications.

  • A field emission nano-focus x-ray source with effective electron beam focusing module

    by Sora Park, Jin-Woo Jeong, Jae-Woo Kim, Jun-Tae Kang, Ji-Hwan Yeon, Min-Sik Shin, Sunghee Kim, Eunsol Go, Hyojin Jeon, Young Chul Choi, et al.

    We developed a field emission nano-focus x-ray source using carbon nanotube (CNT) emitters and electron beam (E-beam) focusing modules, which could be used in the applications requiring the high-resolution x-ray images. For the nano-size focusing of E-beam from CNT emitters, we designed special focusing modules consisting of electrostatic and magnetic lenses. The geometries and operating conditions of focusing modules were optimized to give the desired demagnification characteristics by performing the electron optics simulations of the designed x-ray source under external electric and magnetic fields. We constructed and operated an open-type nano-focus x-ray system using the focusing modules under a high-voltage condition to attain the high-resolution x-ray images. The results showed a possibility of field emission nano-focus x-ray sources with a relatively high current and controllable magnification through the effective focusing modules.

  • A high-performance carbon nanotube-based field emission x-ray tube for commercial dental imaging

    by Sora Park, Jin-Woo Jeong, Jae-Woo Kim, Jun-Tae Kang, Ji-Hwan Yeon, Min-Sik Shin, Sunghee Kim, Eunsol Go, Hyojin Jeon, Young Chul Choi, et al.

    We developed a fully vacuum-sealed carbon nanotube (CNT)-based field emission x-ray tube with commercial-level performance for dental imaging application. The CNT x-ray tube was designed in a triode configuration with the focus-functional gate and had a compact size, much smaller than the conventional hot-cathode tubes. The small size of CNT x-ray tubes along with no cathode heating enables us to make a very compact portable dental imaging system. We have obtained a quite good x-ray image of a human tooth phantom by operating the CNT x-ray tube in an anode voltage of 65 kV, an emission current of 3 m A, and a pulse duration of 0.5 s, which is comparable to that of the conventional commercial hot-cathode tube.


  • Digital properties of field emission X-ray tubes with carbon nanotube field emitters

    by Jun-Tae Kang, Min-Sik Shin, Hyojin Jeon, Jin-Woo Jeong, Young-Chul Choi, Jae-Woo Kim, Sora Park, Ji-Hwan Yeon, Yoon-Ho Song

    We describe reliable CNT x-ray tubes and their digital properties such as easy modulation of x-ray dose, high-speed operation, and low-voltage and low-power consumption control with an active-current control unit (ACCU) developed. The simple and advanced ACCU was found to shorten the response time of CNT x-ray tube down to sub-microsecond along with stable and reliable operation. The fast digital CNT x-ray tubes with the ACCU could provide improved x-ray imaging like blur-less and short-time scanning.