Mika Vestenius
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mika Vestenius has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Karri Saarnio
Finnish Meteorological Institute
3 shared publications Hannele Hakola
Atmospheric Composition Research, Finnish Meteorological Institute, Helsinki, Finland
2 shared publications- Katriina Kyllönen
Finnish Meteorological Institute Helsinki Finland
2 shared publications A. Järvinen
1 shared publication- Andre Stephan Henry Prevot
Paul Scherrer Institute
1 shared publication - Andreas Massling
Department of Environmental Science, Aarhus University, Roskilde, Denmark
1 shared publication
Latest Publications
- Open Access
- 14 July 2026
- Published by Elsevier in Atmospheric Environment
- Vol. 382
Composition and sources of atmospheric trace elements at three urban sites in Helsinki, Finland
- 14 July 2026
- Published by Elsevier in Atmospheric Environment
- Vol. 382
Open AccessComposition and sources of atmospheric trace elements at three urban sites in Helsinki, Finland
- 1 January 2025
- Published by Finnish Meteorological Institute
Verification of suitability of automated PM10 and PM2.5 measuring systems in Finland 2021 (Ongoing-2021)
The Air Quality Directive (2008/50/EC) defines the reference methods (RM) for determining the mass concentration of particulate matter (PM) in air. A Member State may use other methods provided that they can demonstrate a consistent relationship with the reference method. In Finland, a demonstration of equivalence (DoE) for automated continuous monitoring systems (AMS) for PM10 and PM2.5 was conducted in Kuopio in 2014–2015 (Waldén et al., 2017). The AMS instruments used in DoE and this study are the ones that are widely used in local air quality networks to control compliance with the limit values for particulate matter concentrations. The present study verifies the suitability of calibration factors obtained in the Kuopio DoE for use elsewhere in Finland. The 2021 verification campaign was carried out at the Tikkurila station in Vantaa, operated by Helsinki Region Environmental Services (HSY), within the project National quality program for particulate matter measurements: Ongoing verification of suitability of automated measuring systems (Ongoing 2021). Seven AMS representing different instrument types and measurement techniques were compared with the gravimetric reference method according to EN 12341:2014. The verification followed a modified approach based on EN 16450:2017, enabling broader inclusion of instruments over a seven-month campaign. The results showed that TEOM 1405, TEOM 1405-D, and Palas Fidas 200 S performed within the expanded uncertainty limit (≤25%) for PM10 measurements, while GRIMM EDM180 failed with the Kuopio DoE calibration but it would pass when a new theoretical equation derived from the current study would be applied. For PM2.5, TEOM 1405 and Palas Fidas 200 S fulfilled the uncertainty criteria, whereas TEOM 1405-D and GRIMM EDM180 did not, although both would pass using revised theoretical calibration factors. The correction equations of TEOM 1405-D are not official, and they are not recommended for wider use. Two Palas AQ Guard monitors were also tested for the first time in Finland, showing promising results for both PM10 and PM2.5, with uncertainties below 25%, but lacking EN 16450:2017 type-testing certification. Overall, the verification confirmed that the calibration factors from the Kuopio DoE remain valid for TEOM 1405 and the provisional calibration factors from Ongoing 2019–2020 (Saarnio et al., 2021) for Palas Fidas 200 series instruments. GRIMM EDM180 requires additional verification tests or an updated calibration equation, TEOM 1405-D needs a revised correction equation for PM2.5, and Palas AQ Guard instruments show potential for good performance in PM monitoring. The results highlight the importance of continued national verification to ensure consistent and reliable particulate matter measurements throughout Finland.
- 1 January 2025
- Published by Finnish Meteorological Institute
Verification of suitability of automated PM10 and PM2.5 measuring systems in Finland 2021 (Ongoing-2021)
The Air Quality Directive (2008/50/EC) defines the reference methods (RM) for determining the mass concentration of particulate matter (PM) in air. A Member State may use other methods provided that they can demonstrate a consistent relationship with the reference method. In Finland, a demonstration of equivalence (DoE) for automated continuous monitoring systems (AMS) for PM10 and PM2.5 was conducted in Kuopio in 2014–2015 (Waldén et al., 2017). The AMS instruments used in DoE and this study are the ones that are widely used in local air quality networks to control compliance with the limit values for particulate matter concentrations. The present study verifies the suitability of calibration factors obtained in the Kuopio DoE for use elsewhere in Finland. The 2021 verification campaign was carried out at the Tikkurila station in Vantaa, operated by Helsinki Region Environmental Services (HSY), within the project National quality program for particulate matter measurements: Ongoing verification of suitability of automated measuring systems (Ongoing 2021). Seven AMS representing different instrument types and measurement techniques were compared with the gravimetric reference method according to EN 12341:2014. The verification followed a modified approach based on EN 16450:2017, enabling broader inclusion of instruments over a seven-month campaign. The results showed that TEOM 1405, TEOM 1405-D, and Palas Fidas 200 S performed within the expanded uncertainty limit (≤25%) for PM10 measurements, while GRIMM EDM180 failed with the Kuopio DoE calibration but it would pass when a new theoretical equation derived from the current study would be applied. For PM2.5, TEOM 1405 and Palas Fidas 200 S fulfilled the uncertainty criteria, whereas TEOM 1405-D and GRIMM EDM180 did not, although both would pass using revised theoretical calibration factors. The correction equations of TEOM 1405-D are not official, and they are not recommended for wider use. Two Palas AQ Guard monitors were also tested for the first time in Finland, showing promising results for both PM10 and PM2.5, with uncertainties below 25%, but lacking EN 16450:2017 type-testing certification. Overall, the verification confirmed that the calibration factors from the Kuopio DoE remain valid for TEOM 1405 and the provisional calibration factors from Ongoing 2019–2020 (Saarnio et al., 2021) for Palas Fidas 200 series instruments. GRIMM EDM180 requires additional verification tests or an updated calibration equation, TEOM 1405-D needs a revised correction equation for PM2.5, and Palas AQ Guard instruments show potential for good performance in PM monitoring. The results highlight the importance of continued national verification to ensure consistent and reliable particulate matter measurements throughout Finland.
- Open Access
- 28 February 2022
- Published by Springer Nature in Nature Geoscience
- Vol. 15 (3) , 196-202
Equal abundance of summertime natural and wintertime anthropogenic Arctic organic aerosols
Aerosols play an important yet uncertain role in modulating the radiation balance of the sensitive Arctic atmosphere. Organic aerosol is one of the most abundant, yet least understood, fractions of the Arctic aerosol mass. Here we use data from eight observatories that represent the entire Arctic to reveal the annual cycles in anthropogenic and biogenic sources of organic aerosol. We show that during winter, the organic aerosol in the Arctic is dominated by anthropogenic emissions, mainly from Eurasia, which consist of both direct combustion emissions and long-range transported, aged pollution. In summer, the decreasing anthropogenic pollution is replaced by natural emissions. These include marine secondary, biogenic secondary and primary biological emissions, which have the potential to be important to Arctic climate by modifying the cloud condensation nuclei properties and acting as ice-nucleating particles. Their source strength or atmospheric processing is sensitive to nutrient availability, solar radiation, temperature and snow cover. Our results provide a comprehensive understanding of the current pan-Arctic organic aerosol, which can be used to support modelling efforts that aim to quantify the climate impacts of emissions in this sensitive region.
- 28 February 2022
- Published by Springer Nature in Nature Geoscience
- Vol. 15 (3) , 196-202
Open AccessEqual abundance of summertime natural and wintertime anthropogenic Arctic organic aerosols
Aerosols play an important yet uncertain role in modulating the radiation balance of the sensitive Arctic atmosphere. Organic aerosol is one of the most abundant, yet least understood, fractions of the Arctic aerosol mass. Here we use data from eight observatories that represent the entire Arctic to reveal the annual cycles in anthropogenic and biogenic sources of organic aerosol. We show that during winter, the organic aerosol in the Arctic is dominated by anthropogenic emissions, mainly from Eurasia, which consist of both direct combustion emissions and long-range transported, aged pollution. In summer, the decreasing anthropogenic pollution is replaced by natural emissions. These include marine secondary, biogenic secondary and primary biological emissions, which have the potential to be important to Arctic climate by modifying the cloud condensation nuclei properties and acting as ice-nucleating particles. Their source strength or atmospheric processing is sensitive to nutrient availability, solar radiation, temperature and snow cover. Our results provide a comprehensive understanding of the current pan-Arctic organic aerosol, which can be used to support modelling efforts that aim to quantify the climate impacts of emissions in this sensitive region.
- 1 December 2021
- Published by Finnish Meteorological Institute
Attestation of conformity of particulate matter measurements (HIVATO) 2019–2020
The National Reference Laboratory for Air Quality (NRL) ensures the high quality of air quality measurements in Finland by organising audits and intercomparison campaigns. In this project, the conformity of the particulate matter measurements was evaluated with a particular focus on the measurement used for calculating the average exposure index (AEI) of Finland. The representativity and applicability of the AEI measurements made at the Kallio station in Helsinki were evaluated. It was noticed that the results of the Kallio measurement represent well the average fine particle (PM2.5) concentrations and the yearly based trend of fine particles in Finland. In addition, the yearly average concentrations of fine particles have been smaller than the AEI limit value of 8.5 µg/m3, at all individual urban background stations in Finland since year 2015. The measurement results made with the PM monitor used for AEI measurement, i.e. TEOM 1405 analyser at the Kallio station, were compared to the results from the reference method that follows the standard SFS-EN 12341:2014. It was noticed that the uncertainty requirement of 25% was reached and therefore the quality of the measurement is sufficient to use it for the calculation of AEI. However, the fine particle concentrations were generally very low and therefore the requirements given in the standard SFS-EN 16450:2017 for an intercomparison against the reference method were not perfectly fulfilled. This report presents also results from intercomparison measurements made for automated continuous measurement systems (AMS). At the Virolahti station and at the Mäkelänkatu station in Helsinki, PM10 and PM2.5 measurements were compared. In Kuopio and in Lahti, intercomparison measurements were made for PM2.5 only. Based on the results from these intercomparisons, the calibration coefficients both for PM10 and PM2.5 were defined for the first time in Finland for a FIDAS 200 analyser that is a new PM monitor in the Finnish market. It was concluded that FIDAS 200 analysers can be used for the PM measurements in Finland when the calibration coefficients are applied for the data; however, one must note that the presented calibration coefficients do not fulfil the requirements given for the demonstration of equivalence (DoE). Nevertheless, these coefficients are recommended to be used until the official coefficients will be delivered from the next DoE campaign. Two AMS (SHARP 5030 and TEOM 1405) were compared to the reference method for the measurements of PM10 and PM2,5 in Virolahti and in Helsinki, respectively. It was revealed that the calibration coefficients based on the DoE in Kuopio (2014–2015) do not always fit ideally at different locations and seasons due to differences in the environmental characteristics of the measurement sites. Therefore, NRL recommends that DoE should be organised every five years and in between the DoE’s so called ongoing-intercomparison measurements should be carried out continuously. In the ongoing-intercomparison, suitability of the calibration coefficients from DoE will be verified in different locations with varying environmental characteristics. The ongoing-intercomparison campaigns should take place at one site from a half a year to one year and after that, the campaign should continue at a different location similarly. This would ensure that the influence of seasonal differences to the suitability of coefficients will be verified at each measurement site.
- 1 December 2021
- Published by Finnish Meteorological Institute
Attestation of conformity of particulate matter measurements (HIVATO) 2019–2020
The National Reference Laboratory for Air Quality (NRL) ensures the high quality of air quality measurements in Finland by organising audits and intercomparison campaigns. In this project, the conformity of the particulate matter measurements was evaluated with a particular focus on the measurement used for calculating the average exposure index (AEI) of Finland. The representativity and applicability of the AEI measurements made at the Kallio station in Helsinki were evaluated. It was noticed that the results of the Kallio measurement represent well the average fine particle (PM2.5) concentrations and the yearly based trend of fine particles in Finland. In addition, the yearly average concentrations of fine particles have been smaller than the AEI limit value of 8.5 µg/m3, at all individual urban background stations in Finland since year 2015. The measurement results made with the PM monitor used for AEI measurement, i.e. TEOM 1405 analyser at the Kallio station, were compared to the results from the reference method that follows the standard SFS-EN 12341:2014. It was noticed that the uncertainty requirement of 25% was reached and therefore the quality of the measurement is sufficient to use it for the calculation of AEI. However, the fine particle concentrations were generally very low and therefore the requirements given in the standard SFS-EN 16450:2017 for an intercomparison against the reference method were not perfectly fulfilled. This report presents also results from intercomparison measurements made for automated continuous measurement systems (AMS). At the Virolahti station and at the Mäkelänkatu station in Helsinki, PM10 and PM2.5 measurements were compared. In Kuopio and in Lahti, intercomparison measurements were made for PM2.5 only. Based on the results from these intercomparisons, the calibration coefficients both for PM10 and PM2.5 were defined for the first time in Finland for a FIDAS 200 analyser that is a new PM monitor in the Finnish market. It was concluded that FIDAS 200 analysers can be used for the PM measurements in Finland when the calibration coefficients are applied for the data; however, one must note that the presented calibration coefficients do not fulfil the requirements given for the demonstration of equivalence (DoE). Nevertheless, these coefficients are recommended to be used until the official coefficients will be delivered from the next DoE campaign. Two AMS (SHARP 5030 and TEOM 1405) were compared to the reference method for the measurements of PM10 and PM2,5 in Virolahti and in Helsinki, respectively. It was revealed that the calibration coefficients based on the DoE in Kuopio (2014–2015) do not always fit ideally at different locations and seasons due to differences in the environmental characteristics of the measurement sites. Therefore, NRL recommends that DoE should be organised every five years and in between the DoE’s so called ongoing-intercomparison measurements should be carried out continuously. In the ongoing-intercomparison, suitability of the calibration coefficients from DoE will be verified in different locations with varying environmental characteristics. The ongoing-intercomparison campaigns should take place at one site from a half a year to one year and after that, the campaign should continue at a different location similarly. This would ensure that the influence of seasonal differences to the suitability of coefficients will be verified at each measurement site.
- 27 October 2021
- Published by Finnish Meteorological Institute
Sources of Selected Chemical Components in Atmospheric Components in Finland
Air pollution is an important environmental risk to human health and ecosystems around the world. Particulate matter (PM), especially fine particulate matter, is an important part of this air pollution problem. Particle composition varies greatly and depends on the emission source. In addition to inorganic components, organic particulate fraction can contain several hundred organic compounds from anthropogenic and natural sources. The health risk of particulate is related to the particle size and the compounds inside or on the surface of the aerosol particles. The overall aim of this thesis was to study the selected chemical substances of atmospheric aerosol from both anthropogenic and natural sources. Concentrations of polycyclic aromatic hydrocarbons (PAH) and biogenic organic acids in aerosol were measured, and their effect on the local air quality was estimated. The sources of PAHs, trace elements, biogenic volatile organic compounds (BVOCs), and persistent organic compounds (POPs) in air were studied using positive matrix factorization (PMF), which was used as the main source apportionment tool in three of five papers and for the unpublished data in this thesis. Particles from burning emissions, e.g., diesel particles and particles from biomass burning, are the most toxic in our daily environment. Because of intensive wood use for heating and in sauna stoves, residential biomass burning is the major PAH air pollution source in Finland. Sources of atmospheric PAH pollution and its influence on local air quality were estimated at Virolahti background air quality station and in the Helsinki Metropolitan Area (HMA). The main source of PAHs at Virolahti were found to be combustion- and traffic-related source from the direction of St. Petersburg. Instead, local traffic appeared to have a very small influence on PAH levels in HMA, as local residential wood burning was found to be the main b(a)p source in Helsinki Metropolitan Area. Biogenic VOCs like monoterpenes and sesquiterpenes are highly reactive and oxidize rapidly in the atmosphere, producing secondary organic aerosol (SOA). We showed that positive matrix factorization (PMF) is a useful tool in estimating separate sources in a quasistationary dynamic system like ambient VOC concentrations in the boreal forest. Selected biogenic organic acids were measured from fine particles in the boreal forest in order to estimate their influence on aerosol production. Results indicated that sesquiterpene emissions from boreal forest are probably underestimated and their oxidation products probably have more important role in the SOA production that previously estimated. The Kola Peninsula area was found to be the major source of heavy metal pollution at Pallas. However, as Norilsk Nickel has now partly shut down its metallurgical operations, the trace element and SO2 emissions from the Kola Peninsula should be declining in the future. The ambient concentrations of POP compounds are globally declining but, in the Arctic, for some compounds this is not the case. In the source apportionment study for Pallas 1996–2018 POPs data, relatively big portion of measured POPs at Pallas came within the marine source from clean areas from the north. These long-lived compounds, which have migrated into the Arctic from the southern areas along the air and sea currents for many decades, are now released back into the atmosphere from the melting Arctic ice cover due to global warming. For these compounds, the Arctic has turned from the sink to the source.
- 27 October 2021
- Published by Finnish Meteorological Institute
Sources of Selected Chemical Components in Atmospheric Components in Finland
Air pollution is an important environmental risk to human health and ecosystems around the world. Particulate matter (PM), especially fine particulate matter, is an important part of this air pollution problem. Particle composition varies greatly and depends on the emission source. In addition to inorganic components, organic particulate fraction can contain several hundred organic compounds from anthropogenic and natural sources. The health risk of particulate is related to the particle size and the compounds inside or on the surface of the aerosol particles. The overall aim of this thesis was to study the selected chemical substances of atmospheric aerosol from both anthropogenic and natural sources. Concentrations of polycyclic aromatic hydrocarbons (PAH) and biogenic organic acids in aerosol were measured, and their effect on the local air quality was estimated. The sources of PAHs, trace elements, biogenic volatile organic compounds (BVOCs), and persistent organic compounds (POPs) in air were studied using positive matrix factorization (PMF), which was used as the main source apportionment tool in three of five papers and for the unpublished data in this thesis. Particles from burning emissions, e.g., diesel particles and particles from biomass burning, are the most toxic in our daily environment. Because of intensive wood use for heating and in sauna stoves, residential biomass burning is the major PAH air pollution source in Finland. Sources of atmospheric PAH pollution and its influence on local air quality were estimated at Virolahti background air quality station and in the Helsinki Metropolitan Area (HMA). The main source of PAHs at Virolahti were found to be combustion- and traffic-related source from the direction of St. Petersburg. Instead, local traffic appeared to have a very small influence on PAH levels in HMA, as local residential wood burning was found to be the main b(a)p source in Helsinki Metropolitan Area. Biogenic VOCs like monoterpenes and sesquiterpenes are highly reactive and oxidize rapidly in the atmosphere, producing secondary organic aerosol (SOA). We showed that positive matrix factorization (PMF) is a useful tool in estimating separate sources in a quasistationary dynamic system like ambient VOC concentrations in the boreal forest. Selected biogenic organic acids were measured from fine particles in the boreal forest in order to estimate their influence on aerosol production. Results indicated that sesquiterpene emissions from boreal forest are probably underestimated and their oxidation products probably have more important role in the SOA production that previously estimated. The Kola Peninsula area was found to be the major source of heavy metal pollution at Pallas. However, as Norilsk Nickel has now partly shut down its metallurgical operations, the trace element and SO2 emissions from the Kola Peninsula should be declining in the future. The ambient concentrations of POP compounds are globally declining but, in the Arctic, for some compounds this is not the case. In the source apportionment study for Pallas 1996–2018 POPs data, relatively big portion of measured POPs at Pallas came within the marine source from clean areas from the north. These long-lived compounds, which have migrated into the Arctic from the southern areas along the air and sea currents for many decades, are now released back into the atmosphere from the melting Arctic ice cover due to global warming. For these compounds, the Arctic has turned from the sink to the source.
- 1 September 2016
- Published by Elsevier in Atmospheric Environment
- Vol. 140, 22-33
Assessment of the spatial and temporal distribution of persistent organic pollutants (POPs) in the Nordic atmosphere
- 1 September 2016
- Published by Elsevier in Atmospheric Environment
- Vol. 140, 22-33
Assessment of the spatial and temporal distribution of persistent organic pollutants (POPs) in the Nordic atmosphere