Wenjing Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wenjing Zhang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Zhikuang Cai
Nanjing University of Posts and Telecommunications
2 shared publications - Zixuan Wang
Nanjing University of Posts and Telecommunications
2 shared publications - Ka-Meng Lei
University of Macau
1 shared publication - Pui-In Mak
University of Macau
1 shared publication - Tailong Xu
Department of Electronic Information Engineering, School of Advanced Manufacturing Engineering, Hefei University, Hefei, Anhui, China
1 shared publication - Xin Wang
National and Local Joint Engineering Laboratory of RF Integration and Micro-Assembly Technology, College of Electronic and Optical Engineering & College of Microelectronics, Nanjing University of Posts and Telecommunications, Nanjing 210023, China
1 shared publication
Latest Publications
- 3 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 59 (11) , 3780-3790
A 16-MHz Crystal Oscillator With 17.5- μ s Start-Up Time Under 104-ppm- Δ F Injection Using Automatic Phase-Error Correction
Fast start-up crystal oscillators (XOs) based on energy injection with an auxiliary oscillator (AO) are efficacious in improving the energy consumption of duty-cycled the Internet of Things (IoT) devices. Nonetheless, the frequency mismatch ( ${\Delta } {F}$ ) between the injection frequency and the crystal’s resonance frequency restrains the injection efficiency and start-up improvement. This work presents an automatic phase-error correction (APEC) technique for automatically correcting the phase error incurred due to ${\Delta } {F}$ up to $10{^{4}}$ ppm and safeguarding the XO start-up performance. An inflection detector (ID) based on a dynamic comparator (DCMP) traces the crystal resonant signal’s peak points and selects the appropriate signals for injection. We fabricated the proposed fast start-up XO in a 40-nm CMOS process. It achieves a start-up time of $17.5~{\mu }$ s with a 16-MHz crystal and a 1.0-V ${V} {_{\text {DD}}}$ . Furthermore, the start-up time only varies by ±1.42% over a ${\Delta } {F}$ of ${\pm } 10{^{4}}$ ppm, and ±4.5% amid temperature variations (−40°C to $85~{^{\circ }}$ C), evincing the robustness of the proposed technique. The power consumption and phase noise in the steady state are $84~{\mu }$ W and −139 dBc/Hz at 1-kHz offset, respectively.
- 3 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 59 (11) , 3780-3790
A 16-MHz Crystal Oscillator With 17.5- μ s Start-Up Time Under 104-ppm- Δ F Injection Using Automatic Phase-Error Correction
Fast start-up crystal oscillators (XOs) based on energy injection with an auxiliary oscillator (AO) are efficacious in improving the energy consumption of duty-cycled the Internet of Things (IoT) devices. Nonetheless, the frequency mismatch ( ${\Delta } {F}$ ) between the injection frequency and the crystal’s resonance frequency restrains the injection efficiency and start-up improvement. This work presents an automatic phase-error correction (APEC) technique for automatically correcting the phase error incurred due to ${\Delta } {F}$ up to $10{^{4}}$ ppm and safeguarding the XO start-up performance. An inflection detector (ID) based on a dynamic comparator (DCMP) traces the crystal resonant signal’s peak points and selects the appropriate signals for injection. We fabricated the proposed fast start-up XO in a 40-nm CMOS process. It achieves a start-up time of $17.5~{\mu }$ s with a 16-MHz crystal and a 1.0-V ${V} {_{\text {DD}}}$ . Furthermore, the start-up time only varies by ±1.42% over a ${\Delta } {F}$ of ${\pm } 10{^{4}}$ ppm, and ±4.5% amid temperature variations (−40°C to $85~{^{\circ }}$ C), evincing the robustness of the proposed technique. The power consumption and phase noise in the steady state are $84~{\mu }$ W and −139 dBc/Hz at 1-kHz offset, respectively.
- Open Access
- 25 June 2021
- Published by MDPI AG in Electronics
- Vol. 10 (13) , 1542
A Pipeline-TDC-Based CMOS Temperature Sensor with a 48 fJ·K2 Resolution FoM
An energy-efficient temperature sensor is important for temperature monitoring in Biomedical Internet-of-things (BIoT) applications. This article presents a time-domain temperature sensor with a pipeline time-to-digital converter (TDC). A programmable-gain time amplifier (PGTA) with high linearity and wide linear range is proposed to improve the resolution of the sensor and to reduce the chip area. The conversion time of the sensor is reduced by the fast TDC that only needs ~26 ns/conversion, which means the sensor is suitable for BIoT applications that commonly use duty cycling mode. Fabricated in a 40 nm standard CMOS technology, the sensor consumes 7.6 μA at a 0.6 V supply and achieves a resolution of 90 mK and a sensitivity of 0.62%/°C in a 1.3 μs conversion time. This translates into a resolution figure-of-merit of 48 fJ·K2. The sensor achieves an inaccuracy of 0.39 °C from −20 °C to 80 °C after two-point calibration. Duty cycling the sensor results in an even lower average power: ~18.6 nW at 10 conversions/s.
- 25 June 2021
- Published by MDPI AG in Electronics
- Vol. 10 (13) , 1542
Open AccessA Pipeline-TDC-Based CMOS Temperature Sensor with a 48 fJ·K2 Resolution FoM
An energy-efficient temperature sensor is important for temperature monitoring in Biomedical Internet-of-things (BIoT) applications. This article presents a time-domain temperature sensor with a pipeline time-to-digital converter (TDC). A programmable-gain time amplifier (PGTA) with high linearity and wide linear range is proposed to improve the resolution of the sensor and to reduce the chip area. The conversion time of the sensor is reduced by the fast TDC that only needs ~26 ns/conversion, which means the sensor is suitable for BIoT applications that commonly use duty cycling mode. Fabricated in a 40 nm standard CMOS technology, the sensor consumes 7.6 μA at a 0.6 V supply and achieves a resolution of 90 mK and a sensitivity of 0.62%/°C in a 1.3 μs conversion time. This translates into a resolution figure-of-merit of 48 fJ·K2. The sensor achieves an inaccuracy of 0.39 °C from −20 °C to 80 °C after two-point calibration. Duty cycling the sensor results in an even lower average power: ~18.6 nW at 10 conversions/s.