Mahesh Shivabasappa Palled
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mahesh Shivabasappa Palled has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Shailendra S. Suryawanshi
Department of Pharmaceutical Analysis, KLE College of Pharmacy, Belagavi
4 shared publicationsSanit J. Revankar
2 shared publications- Shailendra Sanjay Suryawanshi
Department of Pharmaceutical Analysis, KLE College of Pharmacy, Belagavi, KLE Academy of Higher Education and Research, Belagavi, Karnataka, India
2 shared publications Shweta M. Pandare
2 shared publicationsA. Patel
1 shared publication- A. R. Bhat1 shared publication
Latest Publications
- Open Access
- 18 August 2026
- Published by Manuscript Technomedia LLP in International Journal of Pharmaceutical Investigation
- Vol. 16 (4) , 1578-1592
Integration of Green Chemistry Approach for Development of Box-Behnken Design Assisted RP-HPLC Method for Estimation of Nepafenac in Ophthalmic Dosage Form: A QbD Supported Degradation Approach
Background: NSAIDs, or Non-Steroidal Anti-Inflammatory medicines, are a large family of chemically diverse medications with a wide range of effects. Nepafenac is an anti-inflammatory medication that is used topically as an aqueous solution. Objectives: To develop a simple, dependable, and eco-friendly Reverse-Phase High-Performance Liquid Chromatographic (RP-HPLC) approach for the quantitative measurement of nepafenac in ophthalmic solutions using a Quality by Design (QbD) methodology. Materials and Methods: A Box-Behnken experimental design was used to refine the process and identify the variables influencing chromatographic performance. Chromatographic separation was achieved on a Shimadzu C18 column (250 x 4.6 mm i.d., 5 µm) using a mobile phase of methanol:0.1% orthophosphoric acid in water (75:25 v/v), adjusted to pH 3.0, at a flow rate of 1.1 mL/min and detection at 236 nm. Results: Nepafenac was eluted with a retention time of 4.018 min and showed great accuracy, with recovery ranging from 98.2% to 101.9%. The test for the commercial ophthalmic formulation produced a 96.16% result. Studies on forced deterioration in acidic, alkaline, oxidative, thermal, and photolytic environments validated the method’s stability-indicating properties. Furthermore, the eco-friendliness of the created method was confirmed by evaluating its environmental sustainability using AGREE and the GAPI greenness assessment method. Conclusion: The appropriateness of the suggested method for regular quality control analysis of Nepafenac in ocular dosage forms was demonstrated through its validation in compliance with International Council for Harmonisation (ICH Q2(R2)) criteria.
- 18 August 2026
- Published by Manuscript Technomedia LLP in International Journal of Pharmaceutical Investigation
- Vol. 16 (4) , 1578-1592
Open AccessIntegration of Green Chemistry Approach for Development of Box-Behnken Design Assisted RP-HPLC Method for Estimation of Nepafenac in Ophthalmic Dosage Form: A QbD Supported Degradation Approach
Background: NSAIDs, or Non-Steroidal Anti-Inflammatory medicines, are a large family of chemically diverse medications with a wide range of effects. Nepafenac is an anti-inflammatory medication that is used topically as an aqueous solution. Objectives: To develop a simple, dependable, and eco-friendly Reverse-Phase High-Performance Liquid Chromatographic (RP-HPLC) approach for the quantitative measurement of nepafenac in ophthalmic solutions using a Quality by Design (QbD) methodology. Materials and Methods: A Box-Behnken experimental design was used to refine the process and identify the variables influencing chromatographic performance. Chromatographic separation was achieved on a Shimadzu C18 column (250 x 4.6 mm i.d., 5 µm) using a mobile phase of methanol:0.1% orthophosphoric acid in water (75:25 v/v), adjusted to pH 3.0, at a flow rate of 1.1 mL/min and detection at 236 nm. Results: Nepafenac was eluted with a retention time of 4.018 min and showed great accuracy, with recovery ranging from 98.2% to 101.9%. The test for the commercial ophthalmic formulation produced a 96.16% result. Studies on forced deterioration in acidic, alkaline, oxidative, thermal, and photolytic environments validated the method’s stability-indicating properties. Furthermore, the eco-friendliness of the created method was confirmed by evaluating its environmental sustainability using AGREE and the GAPI greenness assessment method. Conclusion: The appropriateness of the suggested method for regular quality control analysis of Nepafenac in ocular dosage forms was demonstrated through its validation in compliance with International Council for Harmonisation (ICH Q2(R2)) criteria.
- Open Access
- 19 December 2025
- Published by Universidade Federal do Rio Grande do Sul in Drug Analytical Research
- Vol. 9 (2) , 3-12
Bioanalysis of chrysin in human plasma and analytical stability using validated UV-spectrophotometric method: a quality by design approach
Chrysin is a flavonoid with many biological and medicinal activities, such as anti-cancer, anti-inflammatory, anti-diabetic, and antioxidant properties, and has medicinal value. Based on the Quality by Design approach, the present study used a UV-spectrophotometer to develop a bioanalytical method for chrysin in human plasma. The validation of the method was performed as per ICH M10 guidelines. The technique was performed using methanol as a solvent and the spectrum was recorded at a wavelength of 370 nm. The spiked chrysin from plasma was extracted using the protein precipitation method. The developed method was linear with an r2 value of 0.9996 over a concentration range of 4-20 μg/ml. The results of all validation parameters are found to be within the accepted limits with a % RSD value of less than 2% and the % recovery was greater than 95%. The % RSD and % recovery results confirmed that the method was precise and accurate in the study. LOD and LOQ values in plasma samples were found to be 0.47 μg/ml and 1.43 μg/ml respectively. The stability studies like freeze-thaw, and short-term stability studies were also performed and proved the reliability of the method. Therefore, the developed bioanalytical method can effectively estimate chrysin in plasma samples within its sensitivity limits.
- 19 December 2025
- Published by Universidade Federal do Rio Grande do Sul in Drug Analytical Research
- Vol. 9 (2) , 3-12
Open AccessBioanalysis of chrysin in human plasma and analytical stability using validated UV-spectrophotometric method: a quality by design approach
Chrysin is a flavonoid with many biological and medicinal activities, such as anti-cancer, anti-inflammatory, anti-diabetic, and antioxidant properties, and has medicinal value. Based on the Quality by Design approach, the present study used a UV-spectrophotometer to develop a bioanalytical method for chrysin in human plasma. The validation of the method was performed as per ICH M10 guidelines. The technique was performed using methanol as a solvent and the spectrum was recorded at a wavelength of 370 nm. The spiked chrysin from plasma was extracted using the protein precipitation method. The developed method was linear with an r2 value of 0.9996 over a concentration range of 4-20 μg/ml. The results of all validation parameters are found to be within the accepted limits with a % RSD value of less than 2% and the % recovery was greater than 95%. The % RSD and % recovery results confirmed that the method was precise and accurate in the study. LOD and LOQ values in plasma samples were found to be 0.47 μg/ml and 1.43 μg/ml respectively. The stability studies like freeze-thaw, and short-term stability studies were also performed and proved the reliability of the method. Therefore, the developed bioanalytical method can effectively estimate chrysin in plasma samples within its sensitivity limits.
- Open Access
- 6 November 2025
- Published by Frontiers Media SA in Frontiers in Aging Neuroscience
- Vol. 17, 1614962
Biological determinants of blood-based biomarker levels in Alzheimer’s disease: role of nutrition, inflammation, and metabolic factors
Objectives: The review discusses the effect of biological determinants such as nutritional deficiency, systemic inflammation, and metabolic disorders affect blood-based biomarker (BBBM) levels, influencing their use in diagnosing, prognosticating, and treatment in Alzheimer’s disease (AD). While the individual contributions of neuroinflammation, brain insulin resistance, and micronutrient deficiencies to AD pathology are well-established, a significant knowledge gap exists in understanding their intricate, synergistic interactions. This review proposes a novel integrated framework of bidirectional crosstalk where these three factors create a self-perpetuating cycle of neurodegeneration. Methods: A comprehensive literature review was conducted, including all aspects of epidemiological and biological context associated with vitamins, micronutrients, and dietary patterns; inflammatory cytokines; insulin resistance; metabolic syndrome; and hormonal changes. Emerging integrative approaches such as multi-omics, AI modeling, and systems biology were also reviewed for their possible refinement in biomarker interpretation. Results: The results prove that the deprivation of vitamins E, D, B12, and antioxidants contributes to oxidative stress and subsequent neuroinflammation that changes levels of blood-based biomarkers. A chronic state of inflammation caused by cytokines like IL-6, IL-18, and TNF-α represents a major link to the formation of increased amyloid plaques and tau tangles. Metabolically deregulated states, such as insulin resistance, dyslipidemia, and thyroid imbalance, further alter variability in biomarkers. All these factors would act together to affect the expression of key biomarkers-Aβ, p-tau, and neurofilament light chain (NFL). Individualized interpretation, stratified clinical trials, and digital monitoring tools are potentially effective for achieving better diagnostic precision and boosting treatment efficacy. Conclusion: To a large extent, factors must all be understood thoroughly from multiple biological angles to improve early diagnosis, risk prevention, and treatment personalization in AD. Future studies should develop integrative models that consider nutrition, metabolism, and inflammation to address and fully exploit biomarker utility as well as support precision medicine approaches.
- 6 November 2025
- Published by Frontiers Media SA in Frontiers in Aging Neuroscience
- Vol. 17, 1614962
Open AccessBiological determinants of blood-based biomarker levels in Alzheimer’s disease: role of nutrition, inflammation, and metabolic factors
Objectives: The review discusses the effect of biological determinants such as nutritional deficiency, systemic inflammation, and metabolic disorders affect blood-based biomarker (BBBM) levels, influencing their use in diagnosing, prognosticating, and treatment in Alzheimer’s disease (AD). While the individual contributions of neuroinflammation, brain insulin resistance, and micronutrient deficiencies to AD pathology are well-established, a significant knowledge gap exists in understanding their intricate, synergistic interactions. This review proposes a novel integrated framework of bidirectional crosstalk where these three factors create a self-perpetuating cycle of neurodegeneration. Methods: A comprehensive literature review was conducted, including all aspects of epidemiological and biological context associated with vitamins, micronutrients, and dietary patterns; inflammatory cytokines; insulin resistance; metabolic syndrome; and hormonal changes. Emerging integrative approaches such as multi-omics, AI modeling, and systems biology were also reviewed for their possible refinement in biomarker interpretation. Results: The results prove that the deprivation of vitamins E, D, B12, and antioxidants contributes to oxidative stress and subsequent neuroinflammation that changes levels of blood-based biomarkers. A chronic state of inflammation caused by cytokines like IL-6, IL-18, and TNF-α represents a major link to the formation of increased amyloid plaques and tau tangles. Metabolically deregulated states, such as insulin resistance, dyslipidemia, and thyroid imbalance, further alter variability in biomarkers. All these factors would act together to affect the expression of key biomarkers-Aβ, p-tau, and neurofilament light chain (NFL). Individualized interpretation, stratified clinical trials, and digital monitoring tools are potentially effective for achieving better diagnostic precision and boosting treatment efficacy. Conclusion: To a large extent, factors must all be understood thoroughly from multiple biological angles to improve early diagnosis, risk prevention, and treatment personalization in AD. Future studies should develop integrative models that consider nutrition, metabolism, and inflammation to address and fully exploit biomarker utility as well as support precision medicine approaches.
- Open Access
- 18 July 2025
- Published by Universidade Federal do Rio Grande do Sul in Drug Analytical Research
- Vol. 9 (1) , 32-41
Quality by design-assisted green uv-spectrophotometric method development and validation for the quantitative estimation of letrozole
Letrozole, a potent aromatase inhibitor, is commonly used in treating hormone-responsive breast cancer. With the rising incidence of breast cancer and increased demand for anticancer agents, this study aims to develop a green, cost-effective, and precise UV-spectrophotometric method for Letrozole estimation using Quality by Design (QbD) and Green Analytical Chemistry (GAC) approaches. A UV-spectrophotometric method was developed using an eco-friendly solvent system to improve the solubility and analytical efficiency of Letrozole. Method optimization was carried out using a QbD to ensure robustness and sustainability. The method was validated as per ICH Q2(R1) guidelines for linearity, accuracy, precision, specificity, and robustness, confirming its suitability for routine analysis. The developed method exhibited excellent linearity within the concentration range of 2–10 µg/mL, with a correlation coefficient (R²) of 0.9994. The limit of detection (LOD) and limit of quantification (LOQ) were determined to be 0.870 µg/mL and 2.021 µg/mL, respectively. Precision, robustness, and ruggedness assessments demonstrated percent relative standard deviation values below 2%, indicating high method reproducibility and reliability. The mean recovery values ranged from 99.71% to 102.40%, confirming the method’s accuracy. Furthermore, the assay of marketed formulations yielded consistent results, supporting the suitability of the method for routine quality control applications. A novel, simple, eco-friendly, and QbD guided UV-spectrophotometric method was successfully developed and validated for the estimation of Letrozole in bulk and pharmaceutical dosage forms. The method is suitable for routine analytical applications due to its precision, accuracy, and environmental sustainability.
- 18 July 2025
- Published by Universidade Federal do Rio Grande do Sul in Drug Analytical Research
- Vol. 9 (1) , 32-41
Open AccessQuality by design-assisted green uv-spectrophotometric method development and validation for the quantitative estimation of letrozole
Letrozole, a potent aromatase inhibitor, is commonly used in treating hormone-responsive breast cancer. With the rising incidence of breast cancer and increased demand for anticancer agents, this study aims to develop a green, cost-effective, and precise UV-spectrophotometric method for Letrozole estimation using Quality by Design (QbD) and Green Analytical Chemistry (GAC) approaches. A UV-spectrophotometric method was developed using an eco-friendly solvent system to improve the solubility and analytical efficiency of Letrozole. Method optimization was carried out using a QbD to ensure robustness and sustainability. The method was validated as per ICH Q2(R1) guidelines for linearity, accuracy, precision, specificity, and robustness, confirming its suitability for routine analysis. The developed method exhibited excellent linearity within the concentration range of 2–10 µg/mL, with a correlation coefficient (R²) of 0.9994. The limit of detection (LOD) and limit of quantification (LOQ) were determined to be 0.870 µg/mL and 2.021 µg/mL, respectively. Precision, robustness, and ruggedness assessments demonstrated percent relative standard deviation values below 2%, indicating high method reproducibility and reliability. The mean recovery values ranged from 99.71% to 102.40%, confirming the method’s accuracy. Furthermore, the assay of marketed formulations yielded consistent results, supporting the suitability of the method for routine quality control applications. A novel, simple, eco-friendly, and QbD guided UV-spectrophotometric method was successfully developed and validated for the estimation of Letrozole in bulk and pharmaceutical dosage forms. The method is suitable for routine analytical applications due to its precision, accuracy, and environmental sustainability.
- 28 April 2025
- Published by Indian Drug Manufacturers' Association (IDMA) in INDIAN DRUGS
- Vol. 62 (04) , 37-47
DESIGN OF EXPERIMENT BASED UV-SPECTROPHOTOMETRIC METHOD FOR QUALITY CONTROL ANALYSIS OF SILYMARIN IN MARKETED TABLET FORMULATION
Silymarin is a significant medication that is used to treat chronic liver disease and liver cirrhosis. The focus of the current study is on the development of UV based analytical procedures for silymarin quantification using quality by design methodologies. Materials and procedures selected significant factors, optimized using central composite design (CCD). The absorbance at 287 nm was taken into account as the response, while the mobile phase ratio and scanning speed were taken into account as independent variables. In order to predict responses within predefined ranges and optimize outcomes using mathematical modelling, we employed response surface plots and design space. These tools were instrumental in developing a framework for anticipating and enhancing responses within specified parameters. The developed analytical method was further verified in accordance with ICH Q2 recommendations. With r2 > 0.999 and % RSD <2, the technique demonstrated high linearity and good recovery. It was discovered that the limit of detection and limit of quantification of the UV created method were adequate and perfectly within the permissible range. The established method for silymarin estimation may serve as a cost-effective quality control approach for routine and industrial-level silymarin estimation in bulk and unit dose forms.
- 28 April 2025
- Published by Indian Drug Manufacturers' Association (IDMA) in INDIAN DRUGS
- Vol. 62 (04) , 37-47
DESIGN OF EXPERIMENT BASED UV-SPECTROPHOTOMETRIC METHOD FOR QUALITY CONTROL ANALYSIS OF SILYMARIN IN MARKETED TABLET FORMULATION
Silymarin is a significant medication that is used to treat chronic liver disease and liver cirrhosis. The focus of the current study is on the development of UV based analytical procedures for silymarin quantification using quality by design methodologies. Materials and procedures selected significant factors, optimized using central composite design (CCD). The absorbance at 287 nm was taken into account as the response, while the mobile phase ratio and scanning speed were taken into account as independent variables. In order to predict responses within predefined ranges and optimize outcomes using mathematical modelling, we employed response surface plots and design space. These tools were instrumental in developing a framework for anticipating and enhancing responses within specified parameters. The developed analytical method was further verified in accordance with ICH Q2 recommendations. With r2 > 0.999 and % RSD <2, the technique demonstrated high linearity and good recovery. It was discovered that the limit of detection and limit of quantification of the UV created method were adequate and perfectly within the permissible range. The established method for silymarin estimation may serve as a cost-effective quality control approach for routine and industrial-level silymarin estimation in bulk and unit dose forms.
- 9 January 2025
- Published by Taylor & Francis in Natural Product Research
- Vol. 40 (11) , 3028-3038
A simple, cost-efficient stability-indicating RP-HPLC method for simultaneous estimation of embelin and piperine for routine analysis of marketed polyherbal capsules and tablets
Embelin (EMB) and Piperine (PIP) alkaloids are reported for -antidiabetic, hypolipidemic, antioxidant, and anti-cancer properties. However, simultaneous analytical methods are scarce. A stability-indicating RP-HPLC method was developed with mobile phase MeOH: 0.1%TEA (pH 4.2 adjusted by OPA) (92:08 v/v ratio), CHEMSIL-ODS, C18 (4.6 × 250mm, 5 µm) column, and 1.2 mL/min -flowrate. Retention times were 3.2, and 6.2 min for PIP and EMB respectively, at 289 nm, and validated as per Q2 (R1) ICH guidelines. Linearity ranging (2-10 µg/mL), with regression coefficients (r2), LOD, and LOQ for PIP were r2 = 0.9979, 0.793 µg/mL, 2.403 µg/mL, and r2 = 0.9974, 0.851 µg/mL, 2.578 µg/mL for EMB. Developed method precision, robustness, and ruggedness were confirmed by Embelia ribes Brum. and Piper nigrum Linn. extracts.
- 9 January 2025
- Published by Taylor & Francis in Natural Product Research
- Vol. 40 (11) , 3028-3038
A simple, cost-efficient stability-indicating RP-HPLC method for simultaneous estimation of embelin and piperine for routine analysis of marketed polyherbal capsules and tablets
Embelin (EMB) and Piperine (PIP) alkaloids are reported for -antidiabetic, hypolipidemic, antioxidant, and anti-cancer properties. However, simultaneous analytical methods are scarce. A stability-indicating RP-HPLC method was developed with mobile phase MeOH: 0.1%TEA (pH 4.2 adjusted by OPA) (92:08 v/v ratio), CHEMSIL-ODS, C18 (4.6 × 250mm, 5 µm) column, and 1.2 mL/min -flowrate. Retention times were 3.2, and 6.2 min for PIP and EMB respectively, at 289 nm, and validated as per Q2 (R1) ICH guidelines. Linearity ranging (2-10 µg/mL), with regression coefficients (r2), LOD, and LOQ for PIP were r2 = 0.9979, 0.793 µg/mL, 2.403 µg/mL, and r2 = 0.9974, 0.851 µg/mL, 2.578 µg/mL for EMB. Developed method precision, robustness, and ruggedness were confirmed by Embelia ribes Brum. and Piper nigrum Linn. extracts.
- Open Access
- 25 October 2024
- Published by Journal of Applied Pharmaceutical Sciences and Research in Journal of Applied Pharmaceutical Sciences and Research
- Vol. 7 (3) , 30-35
QUALITY BY DESIGN STRATEGY FOR DEVELOPMENT AND VALIDATION OF AN RP- HPLC METHOD FOR MARKER-BASED STANDARDIZATION OF FISETIN IN MARKETED HERBAL PREPARATIONS
Introduction: This study underscores the importance of QbD in developing pharmaceutical processes, with a strong emphasis on risk assessment. It demonstrates how QbD principles were applied to create a reliable and cost-effective HPLC method for fisetin capsules, ensuring consistent quality within defined criteria. Method: The method, developed through a rigorous Design of Experiment approach, employs an isocratic elution method using a Chemsil ODS-C18 column with a mobile phase composition of 70:30 methanol to 0.1% OPA. Detection of peaks was achieved with a UV detector set at 362 nm, and an optimal flow rate of 1.0 mL/min was determined. The column oven was maintained at an ambient temperature, and the injection volume was set at 10 μL. Result: Thorough validation following ICH Q2 (R1) guidelines verifies the method’s reliability. Key parameters evaluated during this process include linearity, which was established over a range of 10 to 50 μg/mL with an r² value of 0.997; LoD and LoQ, determined to be 2.903 and 8.797 μg/mL, respectively; and precision and robustness, with %RSD values found to be below 2%. Furthermore, accuracy and assay tests were performed, and the results were within the acceptable range as specified by ICH guidelines. Discussion and Conclusion: The method is particularly suitable for analyzing fisetin capsules in the pharmaceutical industry due to its remarkable sensitivity, selectivity, precision and accuracy. Designed for routine pharmaceutical quality control, this method effectively distinguishes between marketed drugs and the innovator product.
- 25 October 2024
- Published by Journal of Applied Pharmaceutical Sciences and Research in Journal of Applied Pharmaceutical Sciences and Research
- Vol. 7 (3) , 30-35
Open AccessQUALITY BY DESIGN STRATEGY FOR DEVELOPMENT AND VALIDATION OF AN RP- HPLC METHOD FOR MARKER-BASED STANDARDIZATION OF FISETIN IN MARKETED HERBAL PREPARATIONS
Introduction: This study underscores the importance of QbD in developing pharmaceutical processes, with a strong emphasis on risk assessment. It demonstrates how QbD principles were applied to create a reliable and cost-effective HPLC method for fisetin capsules, ensuring consistent quality within defined criteria. Method: The method, developed through a rigorous Design of Experiment approach, employs an isocratic elution method using a Chemsil ODS-C18 column with a mobile phase composition of 70:30 methanol to 0.1% OPA. Detection of peaks was achieved with a UV detector set at 362 nm, and an optimal flow rate of 1.0 mL/min was determined. The column oven was maintained at an ambient temperature, and the injection volume was set at 10 μL. Result: Thorough validation following ICH Q2 (R1) guidelines verifies the method’s reliability. Key parameters evaluated during this process include linearity, which was established over a range of 10 to 50 μg/mL with an r² value of 0.997; LoD and LoQ, determined to be 2.903 and 8.797 μg/mL, respectively; and precision and robustness, with %RSD values found to be below 2%. Furthermore, accuracy and assay tests were performed, and the results were within the acceptable range as specified by ICH guidelines. Discussion and Conclusion: The method is particularly suitable for analyzing fisetin capsules in the pharmaceutical industry due to its remarkable sensitivity, selectivity, precision and accuracy. Designed for routine pharmaceutical quality control, this method effectively distinguishes between marketed drugs and the innovator product.
- Open Access
- 30 August 2024
- Published by Lattice Science Publication (LSP) in International Journal of Advanced Pharmaceutical Sciences and Research
- Vol. 4 (5) , 9-15
A Quality by Design (QBD) Approach for the Development and Validation of RP-HPLC Method for the Quantification of Silymarin Tablet
This study emphasizes the crucial role of Quality by Design (QbD) in developing pharmaceutical procedures, particularly in risk assessment. It demonstrates how QbD principles were applied to create a precise and effective HPLC method for Silymarin Tablets, ensuring consistent quality within specified criteria. The optimized method, developed using a Design of Experiment approach, employs a C18 column (150 mm x 4.6 mm, 5μm) with isocratic elution using a 95:25 ratio of acetonitrile to orthophosphoric acid buffer (pH 3). Peaks were detected using a PDA detector calibrated at 287 nm, with a flow rate of 1.0 mL/min. The column oven temperature was maintained at 25°C, and a 10 μL injection volume was used. Thorough validation, adhering to USP and ICH Q2 (R1) standards, ensures the method's reliability. Key factors such as accuracy, precision, robustness, limit of detection (LOD), and limit of quantification (LOQ) were comprehensively assessed. The method exhibits exceptional sensitivity, selectivity, efficiency, precision, accuracy, and cost-effectiveness, making it ideal for pharmaceutical analysis of Silymarin tablets. It has been validated to effectively differentiate between marketed products, including those closely resembling the original. This method is intended for routine quality control analysis in the pharmaceutical industry, highlighting its suitability and reliability for ongoing use.
- 30 August 2024
- Published by Lattice Science Publication (LSP) in International Journal of Advanced Pharmaceutical Sciences and Research
- Vol. 4 (5) , 9-15
Open AccessA Quality by Design (QBD) Approach for the Development and Validation of RP-HPLC Method for the Quantification of Silymarin Tablet
This study emphasizes the crucial role of Quality by Design (QbD) in developing pharmaceutical procedures, particularly in risk assessment. It demonstrates how QbD principles were applied to create a precise and effective HPLC method for Silymarin Tablets, ensuring consistent quality within specified criteria. The optimized method, developed using a Design of Experiment approach, employs a C18 column (150 mm x 4.6 mm, 5μm) with isocratic elution using a 95:25 ratio of acetonitrile to orthophosphoric acid buffer (pH 3). Peaks were detected using a PDA detector calibrated at 287 nm, with a flow rate of 1.0 mL/min. The column oven temperature was maintained at 25°C, and a 10 μL injection volume was used. Thorough validation, adhering to USP and ICH Q2 (R1) standards, ensures the method's reliability. Key factors such as accuracy, precision, robustness, limit of detection (LOD), and limit of quantification (LOQ) were comprehensively assessed. The method exhibits exceptional sensitivity, selectivity, efficiency, precision, accuracy, and cost-effectiveness, making it ideal for pharmaceutical analysis of Silymarin tablets. It has been validated to effectively differentiate between marketed products, including those closely resembling the original. This method is intended for routine quality control analysis in the pharmaceutical industry, highlighting its suitability and reliability for ongoing use.
- Open Access
- 1 January 2023
- Published by Open Science Publishers LLP in Journal of Applied Pharmaceutical Science
- Vol. 13 (10) , 238-244
A green chemistry approach to establish a conductometric technique for quantifying Metformin HCl in pharmaceutical samples and its greenness assessment using an analytical greenness metric calculator
Green analytical chemistry focuses on making analytical processes safer and more environment friendly for the analyst. The primary goals of the proposed research are to develop and validate a conductometric method with green chemistry assistance for the estimation of Metformin HCl (MET), as well as to assess the method’s level of greenness using the AGREE-analytical greenness measure tool. The conductometric method for quantification of MET was developed in two steps. Step 1: Preparation of working standard solutions of MET and Step 2: Estimation of electrical conductivity of working standard solutions of MET. During the development, various dilutions of MET were prepared in Millipore water (MW) ranging from 50 to 250 μg/ml. The prepared solutions were subjected to the measurement of electrical conductivity using the conductometer ELICO CM 183EC-TDS analyzer version 2.3 instrument. The created approach was authenticated to regulate its routine capabilities in accordance with the most recent International Council for Harmonisation guidelines for regulatory recommendations. With an r2 value of 0.999, MET demonstrated linearity concerning amount ranges from 50 to 250 μg/ml. Less than 2% RSD was observed for each set of validation parameters, which was substantially within acceptable limits. The observed recovery levels ranged from 99% to 100%. According to the AGREE metric tool calculation, the suggested method was deemed to be greener and more suitable for analyzing MET in pharmaceutical samples. The proposed research found to show advantages over reported methods in terms of usage of solvents, cost, and time of analysis. The method suggests the usage of MW as a cheap solvent, only simple dilutions and measuring the conductance of the analyte solution makes the method less time-consuming.
- 1 January 2023
- Published by Open Science Publishers LLP in Journal of Applied Pharmaceutical Science
- Vol. 13 (10) , 238-244
Open AccessA green chemistry approach to establish a conductometric technique for quantifying Metformin HCl in pharmaceutical samples and its greenness assessment using an analytical greenness metric calculator
Green analytical chemistry focuses on making analytical processes safer and more environment friendly for the analyst. The primary goals of the proposed research are to develop and validate a conductometric method with green chemistry assistance for the estimation of Metformin HCl (MET), as well as to assess the method’s level of greenness using the AGREE-analytical greenness measure tool. The conductometric method for quantification of MET was developed in two steps. Step 1: Preparation of working standard solutions of MET and Step 2: Estimation of electrical conductivity of working standard solutions of MET. During the development, various dilutions of MET were prepared in Millipore water (MW) ranging from 50 to 250 μg/ml. The prepared solutions were subjected to the measurement of electrical conductivity using the conductometer ELICO CM 183EC-TDS analyzer version 2.3 instrument. The created approach was authenticated to regulate its routine capabilities in accordance with the most recent International Council for Harmonisation guidelines for regulatory recommendations. With an r2 value of 0.999, MET demonstrated linearity concerning amount ranges from 50 to 250 μg/ml. Less than 2% RSD was observed for each set of validation parameters, which was substantially within acceptable limits. The observed recovery levels ranged from 99% to 100%. According to the AGREE metric tool calculation, the suggested method was deemed to be greener and more suitable for analyzing MET in pharmaceutical samples. The proposed research found to show advantages over reported methods in terms of usage of solvents, cost, and time of analysis. The method suggests the usage of MW as a cheap solvent, only simple dilutions and measuring the conductance of the analyte solution makes the method less time-consuming.
- Open Access
- 31 October 2022
- Published by Springer Nature in Research Square
Development of Conductometric Method for Quantification of Metformin HCl in Bulk and Pharmaceuticals
Purpose The main objectives of proposed research work is to develop and validate novel cost effective conductometric method for quantification of Metformin HCl in bulk and its marketed pharmaceuticals. Methods The proposed conductometric method makes the use Millipore water as solvent system for the analysis. The method was developed by preparing various concentration of analyte in water and measuring the electrical conductance. In order to measure the electrical conductivity of analyte solution ELICO CM 183EC-TDS analyser version 2.3 was utilized. The developed method was validated in order to standardize its performance as per current regulatory recommendations. Results Metformin HCl displayed the linearity between the concentration ranges of 50 to 250 µg/mL with r2 value of 0.9999. The % relative standard deviation observed at each validation parameters was well within the acceptance with less than 2% RSD. The recovery values were observed between 99 to 100%. Conclusion The newly established and authenticated conductometric tool was found to be realistic for quantification of Metformin HCl in its marketed tablet pharmaceuticals.
- 31 October 2022
- Published by Springer Nature in Research Square
Open AccessDevelopment of Conductometric Method for Quantification of Metformin HCl in Bulk and Pharmaceuticals
Purpose The main objectives of proposed research work is to develop and validate novel cost effective conductometric method for quantification of Metformin HCl in bulk and its marketed pharmaceuticals. Methods The proposed conductometric method makes the use Millipore water as solvent system for the analysis. The method was developed by preparing various concentration of analyte in water and measuring the electrical conductance. In order to measure the electrical conductivity of analyte solution ELICO CM 183EC-TDS analyser version 2.3 was utilized. The developed method was validated in order to standardize its performance as per current regulatory recommendations. Results Metformin HCl displayed the linearity between the concentration ranges of 50 to 250 µg/mL with r2 value of 0.9999. The % relative standard deviation observed at each validation parameters was well within the acceptance with less than 2% RSD. The recovery values were observed between 99 to 100%. Conclusion The newly established and authenticated conductometric tool was found to be realistic for quantification of Metformin HCl in its marketed tablet pharmaceuticals.