Amanda Semper
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Amanda Semper has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Tim Brooks
Public Health England
2 shared publications - Aneesh Chandran
Division of Infection and Immunity, University College London, London, UK
1 shared publication - Angelique Smit
Royal Free London NHS Foundation Trust, London, UK
1 shared publication - Ben O'BRien
Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, UK & William Harvey Research Institute, Barts and the London School of Medicine and Dentistry, Queen Mary University of London, London, UK
1 shared publication - Benjamin Brown
Public Health England
1 shared publication - Benny Chain
Division of Infection and Immunity, University College London
1 shared publication
Latest Publications
- Open Access
Use of dried blood spot samples for SARS-CoV-2 antibody detection using the Roche Elecsys ® high throughput immunoassay
Background: Dried blood spot samples (DBS) provide an alternative sample type to venous blood samples for antibody testing. DBS are used by NHS for diagnosing HCV and by PHE for large scale HIV and Hepatitis C serosurveillance; the applicability of DBS based approaches to SARS-CoV-2 antibody detection is uncertain. Objective: To compare antibody detection in dried blood spot eluates using the Roche Elecsys ® immunoassay (index test) with antibody detection in paired plasma samples, using the same assay (reference test). Setting: One Police and one Fire & Rescue facility in England. Participants: 195 participants within a larger sample COVID-19 serodiagnostics study of keyworkers, EDSAB-HOME. Outcome Measures: Sensitivity and specificity of DBS (the index test) relative to plasma (the reference test), at an experimental cut-off; quality of DBS sample collected; estimates of relative sensitivity of DBS vs. plasma immunoassay in a larger population. Results: 18/195 (9.2%) participants tested positive using plasma samples. DBS sample quality varied markedly by phlebotomist, and low sample volume significantly reduced immunoassay signals. Using a cut-off of ten median absolute deviations above the immunoassay result with negative samples, sensitivity and specificity of DBS were 89.0% (95% CI 67.2, 96.9%) and 100.0% (95% CI 97.9, 100%) respectively compared with using plasma. The limit of detection for DBS is about 30 times higher than for plasma. Conclusion: DBS use for SARS-CoV-2 serology, though feasible, is insensitive relative to immunoassays on plasma. Sample quality impacts on assay performance. Alternatives, including the collection of capillary blood samples, should be considered for screening programs.
Open AccessUse of dried blood spot samples for SARS-CoV-2 antibody detection using the Roche Elecsys ® high throughput immunoassay
Background: Dried blood spot samples (DBS) provide an alternative sample type to venous blood samples for antibody testing. DBS are used by NHS for diagnosing HCV and by PHE for large scale HIV and Hepatitis C serosurveillance; the applicability of DBS based approaches to SARS-CoV-2 antibody detection is uncertain. Objective: To compare antibody detection in dried blood spot eluates using the Roche Elecsys ® immunoassay (index test) with antibody detection in paired plasma samples, using the same assay (reference test). Setting: One Police and one Fire & Rescue facility in England. Participants: 195 participants within a larger sample COVID-19 serodiagnostics study of keyworkers, EDSAB-HOME. Outcome Measures: Sensitivity and specificity of DBS (the index test) relative to plasma (the reference test), at an experimental cut-off; quality of DBS sample collected; estimates of relative sensitivity of DBS vs. plasma immunoassay in a larger population. Results: 18/195 (9.2%) participants tested positive using plasma samples. DBS sample quality varied markedly by phlebotomist, and low sample volume significantly reduced immunoassay signals. Using a cut-off of ten median absolute deviations above the immunoassay result with negative samples, sensitivity and specificity of DBS were 89.0% (95% CI 67.2, 96.9%) and 100.0% (95% CI 97.9, 100%) respectively compared with using plasma. The limit of detection for DBS is about 30 times higher than for plasma. Conclusion: DBS use for SARS-CoV-2 serology, though feasible, is insensitive relative to immunoassays on plasma. Sample quality impacts on assay performance. Alternatives, including the collection of capillary blood samples, should be considered for screening programs.
- Open Access
Healthcare workers with mild / asymptomatic SARS-CoV-2 infection show T cell responses and neutralising antibodies after the first wave
Studies of adaptive immunity to SARS-CoV-2 include characterisation of lethal, severe and mild cases 1-8 . Understanding how long immunity lasts in people who have had mild or asymptomatic infection is crucial. Healthcare worker (HCW) cohorts exposed to and infected by SARS-CoV-2 during the early stages of the pandemic are an invaluable resource to study this question 9-14 . The UK COVIDsortium is a longitudinal, London hospital HCW cohort, followed from the time of UK lockdown 9,10 ; weekly PCR, serology and symptom diaries allowed capture of asymptomatic infection around the time of onset, so duration of immunity could be tracked. Here, we conduct a cross-sectional, case-control, sub-study of 136 HCW at 16-18 weeks after UK lockdown, with 76 having had laboratory-confirmed SARS-CoV-2 mild or asymptomatic infection. Neutralising antibodies (nAb) were present in 90% of infected HCW sampled after the first wave; titres, likely to correlate with functional protection, were present in 66% at 16-18 weeks. T cell responses tended to be lower in asymptomatic infected HCW than those reporting case-definition symptoms of COVID-19, while nAb titres were maintained irrespective of symptoms. T cell and antibody responses were discordant. HCW lacking nAb also showed undetectable T cells to Spike protein but had T cells of other specificities. Our findings suggest that the majority of HCW with mild or asymptomatic SARS-CoV-2 infection carry nAb complemented by multi-specific T cell responses for at least 4 months after mild or asymptomatic SARS-CoV-2 infection.
Open AccessHealthcare workers with mild / asymptomatic SARS-CoV-2 infection show T cell responses and neutralising antibodies after the first wave
Studies of adaptive immunity to SARS-CoV-2 include characterisation of lethal, severe and mild cases 1-8 . Understanding how long immunity lasts in people who have had mild or asymptomatic infection is crucial. Healthcare worker (HCW) cohorts exposed to and infected by SARS-CoV-2 during the early stages of the pandemic are an invaluable resource to study this question 9-14 . The UK COVIDsortium is a longitudinal, London hospital HCW cohort, followed from the time of UK lockdown 9,10 ; weekly PCR, serology and symptom diaries allowed capture of asymptomatic infection around the time of onset, so duration of immunity could be tracked. Here, we conduct a cross-sectional, case-control, sub-study of 136 HCW at 16-18 weeks after UK lockdown, with 76 having had laboratory-confirmed SARS-CoV-2 mild or asymptomatic infection. Neutralising antibodies (nAb) were present in 90% of infected HCW sampled after the first wave; titres, likely to correlate with functional protection, were present in 66% at 16-18 weeks. T cell responses tended to be lower in asymptomatic infected HCW than those reporting case-definition symptoms of COVID-19, while nAb titres were maintained irrespective of symptoms. T cell and antibody responses were discordant. HCW lacking nAb also showed undetectable T cells to Spike protein but had T cells of other specificities. Our findings suggest that the majority of HCW with mild or asymptomatic SARS-CoV-2 infection carry nAb complemented by multi-specific T cell responses for at least 4 months after mild or asymptomatic SARS-CoV-2 infection.