Benjamin Brown
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Benjamin Brown has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Amanda Semper
Public Health England
1 shared publication - David H. Wyllie
Public Health England, UK
1 shared publication EDSAB-HOME Study Investigators
Public Health England, University of Bristol, University of Warwick
1 shared publication- Ezra Linley
Public Health England
1 shared publication - Nicholas Machin
Public Health England
1 shared publication - Ranya Mulchandani
Health Geography and Policy Group, ETH Zurich, Zurich, Switzerland
1 shared publication
Latest Publications
- Open Access
Use of dried blood spot samples for SARS-CoV-2 antibody detection using the Roche Elecsys ® high throughput immunoassay
Background: Dried blood spot samples (DBS) provide an alternative sample type to venous blood samples for antibody testing. DBS are used by NHS for diagnosing HCV and by PHE for large scale HIV and Hepatitis C serosurveillance; the applicability of DBS based approaches to SARS-CoV-2 antibody detection is uncertain. Objective: To compare antibody detection in dried blood spot eluates using the Roche Elecsys ® immunoassay (index test) with antibody detection in paired plasma samples, using the same assay (reference test). Setting: One Police and one Fire & Rescue facility in England. Participants: 195 participants within a larger sample COVID-19 serodiagnostics study of keyworkers, EDSAB-HOME. Outcome Measures: Sensitivity and specificity of DBS (the index test) relative to plasma (the reference test), at an experimental cut-off; quality of DBS sample collected; estimates of relative sensitivity of DBS vs. plasma immunoassay in a larger population. Results: 18/195 (9.2%) participants tested positive using plasma samples. DBS sample quality varied markedly by phlebotomist, and low sample volume significantly reduced immunoassay signals. Using a cut-off of ten median absolute deviations above the immunoassay result with negative samples, sensitivity and specificity of DBS were 89.0% (95% CI 67.2, 96.9%) and 100.0% (95% CI 97.9, 100%) respectively compared with using plasma. The limit of detection for DBS is about 30 times higher than for plasma. Conclusion: DBS use for SARS-CoV-2 serology, though feasible, is insensitive relative to immunoassays on plasma. Sample quality impacts on assay performance. Alternatives, including the collection of capillary blood samples, should be considered for screening programs.
Open AccessUse of dried blood spot samples for SARS-CoV-2 antibody detection using the Roche Elecsys ® high throughput immunoassay
Background: Dried blood spot samples (DBS) provide an alternative sample type to venous blood samples for antibody testing. DBS are used by NHS for diagnosing HCV and by PHE for large scale HIV and Hepatitis C serosurveillance; the applicability of DBS based approaches to SARS-CoV-2 antibody detection is uncertain. Objective: To compare antibody detection in dried blood spot eluates using the Roche Elecsys ® immunoassay (index test) with antibody detection in paired plasma samples, using the same assay (reference test). Setting: One Police and one Fire & Rescue facility in England. Participants: 195 participants within a larger sample COVID-19 serodiagnostics study of keyworkers, EDSAB-HOME. Outcome Measures: Sensitivity and specificity of DBS (the index test) relative to plasma (the reference test), at an experimental cut-off; quality of DBS sample collected; estimates of relative sensitivity of DBS vs. plasma immunoassay in a larger population. Results: 18/195 (9.2%) participants tested positive using plasma samples. DBS sample quality varied markedly by phlebotomist, and low sample volume significantly reduced immunoassay signals. Using a cut-off of ten median absolute deviations above the immunoassay result with negative samples, sensitivity and specificity of DBS were 89.0% (95% CI 67.2, 96.9%) and 100.0% (95% CI 97.9, 100%) respectively compared with using plasma. The limit of detection for DBS is about 30 times higher than for plasma. Conclusion: DBS use for SARS-CoV-2 serology, though feasible, is insensitive relative to immunoassays on plasma. Sample quality impacts on assay performance. Alternatives, including the collection of capillary blood samples, should be considered for screening programs.