Sorin Ionuț Salcu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sorin Ionuț Salcu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Petre Dorel Teodosescu
Department of Electrical Machines and Drives, Technical University of Cluj-Napoca, 400489 Cluj-Napoca, Romania
6 shared publications - Lucian Nicolae Pintilie
Faculty of Electrical Engineering, Technical University of Cluj-Napoca, 26-28 G. Bariţiu Street, 400027 Cluj-Napoca, Romania
5 shared publications - Vasile Mihai Suciu
Department of Electrical Machines and Drives, Technical University of Cluj-Napoca, 400489 Cluj-Napoca, Romania
5 shared publications - Norbert Csaba Szekely
Department of Electrical Machines and Drives, Technical University of Cluj-Napoca, 400489 Cluj-Napoca, Romania
4 shared publications - Alexandru Madalin Pacuraru
Department of Electrical Machines and Drives, Faculty of Electrical Engineering, Technical University of Cluj-Napoca, 400489 Cluj-Napoca, Romania
2 shared publications - Mircea Bojan
Technical University of Cluj-Napoca
2 shared publications
Latest Publications
- Open Access
- 30 March 2024
- Published by MDPI AG in Electronics
- Vol. 13 (7) , 1302
The Condition Number Perspective in Modeling and Designing an Electronic IDBIC Converter
This paper proposes a novel method of evaluating the Independent Double-Boost Interleaved Converter’s performance, which can offer an overview of its behavior and can enhance the design stage of the converter. The concept of “condition number” is utilized and applied to the converter’s model. Correlations between the condition number variation and the converter parameters lead to a qualitative assessment of the converter’s behavior and offer the possibility to anticipate aspects like the stability and response of the converter. An in-depth analysis is conducted, starting from the state matrix and continuing with a series of presumptions regarding the converter and its operating mode, obtaining a series of expressions that define the condition number for the converter.
- 30 March 2024
- Published by MDPI AG in Electronics
- Vol. 13 (7) , 1302
Open AccessThe Condition Number Perspective in Modeling and Designing an Electronic IDBIC Converter
This paper proposes a novel method of evaluating the Independent Double-Boost Interleaved Converter’s performance, which can offer an overview of its behavior and can enhance the design stage of the converter. The concept of “condition number” is utilized and applied to the converter’s model. Correlations between the condition number variation and the converter parameters lead to a qualitative assessment of the converter’s behavior and offer the possibility to anticipate aspects like the stability and response of the converter. An in-depth analysis is conducted, starting from the state matrix and continuing with a series of presumptions regarding the converter and its operating mode, obtaining a series of expressions that define the condition number for the converter.
- Open Access
- 10 October 2023
- Published by MDPI AG in Electricity
- Vol. 4 (4) , 277-308
Energy Conversion Optimization Method in Nano-Grids Using Variable Supply Voltage Adjustment Strategy Based on a Novel Inverse Maximum Power Point Tracking Technique (iMPPT)
This paper introduces a novel power supply voltage adjustment strategy that can determine the optimum voltage value based on the amount of absorbed power. The novel automatic voltage adjustment technique was called inverse maximum power point tracking (iMPPT). The proposed control strategy consists of a modified maximum power point tracking (MPPT) algorithm (more precisely the P&O method). In this case, the modified MPPT technique establishes the minimum value of the input absorbed power of a consumer load served by a switched-mode power supply (SMPS). The iMPPT adjusts the input power by modifying the input voltage of the main power supply. The served loads are connected to the variable power supply via an interfacing power electronics converter that performs the automatic voltage regulation function (AVR). The optimal value of the input voltage level can be achieved when the input power of the automatic voltage regulation converter is at a minimum. In that case, the energy conversion efficiency ratio is at a maximum, and the overall losses related to the front-end power stage are at a minimum. The proposed technique can also be considered a Maximum Efficiency Tracking (MET) method. By performing the inverse operation of a maximum power point tracking algorithm on the input demanded power of a switched mode power supply (SMPS), the optimum input voltage level can be determined when the maximum energy conversion ratio (related to a given load level) is achieved. The novel proposed iMPPT method can improve the energy conversion ratio from 85% up to approximately 10% in the case of an output power level of 800 W served by a synchronous buck converter at the input voltage level of 350 V. The total amount of recovered power in this situation can be approximately 100 W.
- 10 October 2023
- Published by MDPI AG in Electricity
- Vol. 4 (4) , 277-308
Open AccessEnergy Conversion Optimization Method in Nano-Grids Using Variable Supply Voltage Adjustment Strategy Based on a Novel Inverse Maximum Power Point Tracking Technique (iMPPT)
This paper introduces a novel power supply voltage adjustment strategy that can determine the optimum voltage value based on the amount of absorbed power. The novel automatic voltage adjustment technique was called inverse maximum power point tracking (iMPPT). The proposed control strategy consists of a modified maximum power point tracking (MPPT) algorithm (more precisely the P&O method). In this case, the modified MPPT technique establishes the minimum value of the input absorbed power of a consumer load served by a switched-mode power supply (SMPS). The iMPPT adjusts the input power by modifying the input voltage of the main power supply. The served loads are connected to the variable power supply via an interfacing power electronics converter that performs the automatic voltage regulation function (AVR). The optimal value of the input voltage level can be achieved when the input power of the automatic voltage regulation converter is at a minimum. In that case, the energy conversion efficiency ratio is at a maximum, and the overall losses related to the front-end power stage are at a minimum. The proposed technique can also be considered a Maximum Efficiency Tracking (MET) method. By performing the inverse operation of a maximum power point tracking algorithm on the input demanded power of a switched mode power supply (SMPS), the optimum input voltage level can be determined when the maximum energy conversion ratio (related to a given load level) is achieved. The novel proposed iMPPT method can improve the energy conversion ratio from 85% up to approximately 10% in the case of an output power level of 800 W served by a synchronous buck converter at the input voltage level of 350 V. The total amount of recovered power in this situation can be approximately 100 W.
- 17 August 2022
- Published by Springer Nature
- p. 607-615
Integrating the Behavior at Reactive Power Flow in the Model of the Single-Phase PWM Rectifier
- 17 August 2022
- Published by Springer Nature
- p. 607-615
Integrating the Behavior at Reactive Power Flow in the Model of the Single-Phase PWM Rectifier
- Open Access
- 18 July 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (14) , 7209
Power Factor Correction Application Based on Independent Double-Boost Interleaved Converter (IDBIC)
In this paper, a Power Factor Correction (PFC) application, based on the novel power stage topology named Independent Double-Boost Interleaved Converter (IDBIC), has been analyzed. The novelty of the proposed PFC rectifier is based on the sum of capabilities, such as supplying three independent output voltage levels with interleaved operation at the input and high voltage gain. The hardware used within this application consists of an AC input L-C-L filter, a single-phase bridge rectifier, the IDBIC power stage, output capacitors group and a group of variable high-power rheostats (resistors) group as DC load. The main purpose of the carried study was to highlight the advantages and disadvantages of the novel power stage topology in the context of a green and modern AC to DC conversion solution. Nowadays, a high level of the efficiency and power factor have become a mandatory feature for the AC to DC conversion solutions to satisfy the international electrical standards. Thus, considering the modern electrical standards and recommendations, the current study tries to better depict the working steps and principles of the modern power stage topology within an AC to DC conversion application. The behavior of the considered power stage described in different detailed working steps (such as the Discontinuous Conduction Mode and Continuous Conduction Mode) may help understand how the energy conversions process of AC to DC becomes more efficient. The high output voltage gain of the considered power stage is the key feature in the Power Factor Correction process. With such a feature, the AC to DC conversion solution/application can also operate at lower input AC voltages (such as 90 [V] and 110 [V]). The proposed solution can be successfully used in the electric vehicle (automotive field) and high-power electrical traction (e.g., trains, high power electrical machines and drives). The same solution can also be used successfully in fast battery charging applications and chemical electrolysis processes.
- 18 July 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (14) , 7209
Open AccessPower Factor Correction Application Based on Independent Double-Boost Interleaved Converter (IDBIC)
In this paper, a Power Factor Correction (PFC) application, based on the novel power stage topology named Independent Double-Boost Interleaved Converter (IDBIC), has been analyzed. The novelty of the proposed PFC rectifier is based on the sum of capabilities, such as supplying three independent output voltage levels with interleaved operation at the input and high voltage gain. The hardware used within this application consists of an AC input L-C-L filter, a single-phase bridge rectifier, the IDBIC power stage, output capacitors group and a group of variable high-power rheostats (resistors) group as DC load. The main purpose of the carried study was to highlight the advantages and disadvantages of the novel power stage topology in the context of a green and modern AC to DC conversion solution. Nowadays, a high level of the efficiency and power factor have become a mandatory feature for the AC to DC conversion solutions to satisfy the international electrical standards. Thus, considering the modern electrical standards and recommendations, the current study tries to better depict the working steps and principles of the modern power stage topology within an AC to DC conversion application. The behavior of the considered power stage described in different detailed working steps (such as the Discontinuous Conduction Mode and Continuous Conduction Mode) may help understand how the energy conversions process of AC to DC becomes more efficient. The high output voltage gain of the considered power stage is the key feature in the Power Factor Correction process. With such a feature, the AC to DC conversion solution/application can also operate at lower input AC voltages (such as 90 [V] and 110 [V]). The proposed solution can be successfully used in the electric vehicle (automotive field) and high-power electrical traction (e.g., trains, high power electrical machines and drives). The same solution can also be used successfully in fast battery charging applications and chemical electrolysis processes.
- 12 July 2022
- Published by Springer Nature
- p. 539-548
Analysis of an Independent Double Boost Interleaved Converter in a Renewable Energy Application
- 12 July 2022
- Published by Springer Nature
- p. 539-548
Analysis of an Independent Double Boost Interleaved Converter in a Renewable Energy Application
- 12 July 2022
- Published by Springer Nature
- p. 589-600
AC-DC Microgrid Analysis Using a Hybrid Real-Time HiL Approach
- 12 July 2022
- Published by Springer Nature
- p. 589-600
AC-DC Microgrid Analysis Using a Hybrid Real-Time HiL Approach
- Open Access
- 28 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (13) , 5993
Independent Double-Boost Interleaved Converter with Three-Level Output
This paper introduces a novel converter topology based on an independent controlled double-boost configuration. The structure was achieved by combining two independent classic boost converters connected in parallel at the input and in series at the output. Through proper control of the two boost converters, an interleaved topology was obtained, which presents a low ripple for the input current. Being connected in series at the output, a three-level structure was attained with twice the voltage gain of classic boost and interleaved topologies. A significant feature of the proposed converter is the possibility of independent operation of the two integrated boost converters, in both symmetrical and asymmetrical modes. This feature may be particularly useful in voltage balancing or interconnection with bipolar DC grids/applications. The operation principle, simulations, mathematical analysis, and laboratory prototype experimental results are presented.
- 28 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (13) , 5993
Open AccessIndependent Double-Boost Interleaved Converter with Three-Level Output
This paper introduces a novel converter topology based on an independent controlled double-boost configuration. The structure was achieved by combining two independent classic boost converters connected in parallel at the input and in series at the output. Through proper control of the two boost converters, an interleaved topology was obtained, which presents a low ripple for the input current. Being connected in series at the output, a three-level structure was attained with twice the voltage gain of classic boost and interleaved topologies. A significant feature of the proposed converter is the possibility of independent operation of the two integrated boost converters, in both symmetrical and asymmetrical modes. This feature may be particularly useful in voltage balancing or interconnection with bipolar DC grids/applications. The operation principle, simulations, mathematical analysis, and laboratory prototype experimental results are presented.