Gang Xiong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gang Xiong has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
Bo Qing
Research Center of Laser Fusion, China Academy of Engineering Physics 1 , P.O. Box 919-986, Mianyang 621900
8 shared publications- Jiamin Yang
Laser Fusion Research Center, China Academy of Engineering Physics 2 , Mianyang, Sichuan 621900
7 shared publications Yang Zhao
Research Center of Laser Fusion, China Academy of Engineering Physics 1 , P.O. Box 919-986, Mianyang 621900
7 shared publications- Yuxue Zhang
Laser Fusion Research Center, China Academy of Engineering Physics 1 , Mianyang 621900
7 shared publications - Tianming Song
National Key Laboratory on Plasma Physics, Laser Fusion Research Center, China Academy of Engineering Physics 1 , Mianyang 621900
6 shared publications Chengwu Huang
Research Center of Laser Fusion, China Academy of Engineering Physics 1 , Mianyang 621900
5 shared publications
Latest Publications
- Open Access
- 2 September 2026
- Published by AIP Publishing in Matter and Radiation at Extremes
- Vol. 11 (6)
A comparative benchmarking of optical Thomson scattering and various X-ray emission spectroscopies in nanosecond laser-produced plasmas
X-ray emission spectroscopy (XES) and optical Thomson scattering (OTS) are two of the most indispensable diagnostics for characterization of plasma parameters such as Te and ne in intense laser-produced plasmas (LPPs), but both can also provide weighted-average values owing to the line-of-sight, space, and time-integrated effects of optical/X-ray diagnostic techniques, which has not been thoroughly investigated. In this work, for the first time, the consistency and discrepancy between Te from XES and OTS are examined using intense lasers with a large focal spot to irradiate the smaller tip of a cylindrically symmetric titanium wire. Experimental results reveal that Te profiles derived from the two methods are approximately consistent in the earlier period of 1 ns, but exhibit different trends with increasing time. In addition, the impacts of the three integration effects on the interpretation of Te are assessed through an analysis of three types of XES methods, namely, time- and space-resolved, time-resolved but space-integrated, and time-integrated but space-resolved. Our findings indicate that the line-of-sight integration effect causes uncertainties of less than 5% in the electron temperature of corona LPPs, time-integrated XES can replace time-resolved measurements with an uncertainty of 10% for 1–2 ns laser duration, and space-integrated XES reflects the high-temperature region within 200 μm in front of the target surface, ∼10% lower than the maximum. These insights establish a foundation for the applications of experimental data in LPPs, particularly in the fields of laser-driven inertial confinement fusion and high-energy-density physics.
- 2 September 2026
- Published by AIP Publishing in Matter and Radiation at Extremes
- Vol. 11 (6)
Open AccessA comparative benchmarking of optical Thomson scattering and various X-ray emission spectroscopies in nanosecond laser-produced plasmas
X-ray emission spectroscopy (XES) and optical Thomson scattering (OTS) are two of the most indispensable diagnostics for characterization of plasma parameters such as Te and ne in intense laser-produced plasmas (LPPs), but both can also provide weighted-average values owing to the line-of-sight, space, and time-integrated effects of optical/X-ray diagnostic techniques, which has not been thoroughly investigated. In this work, for the first time, the consistency and discrepancy between Te from XES and OTS are examined using intense lasers with a large focal spot to irradiate the smaller tip of a cylindrically symmetric titanium wire. Experimental results reveal that Te profiles derived from the two methods are approximately consistent in the earlier period of 1 ns, but exhibit different trends with increasing time. In addition, the impacts of the three integration effects on the interpretation of Te are assessed through an analysis of three types of XES methods, namely, time- and space-resolved, time-resolved but space-integrated, and time-integrated but space-resolved. Our findings indicate that the line-of-sight integration effect causes uncertainties of less than 5% in the electron temperature of corona LPPs, time-integrated XES can replace time-resolved measurements with an uncertainty of 10% for 1–2 ns laser duration, and space-integrated XES reflects the high-temperature region within 200 μm in front of the target surface, ∼10% lower than the maximum. These insights establish a foundation for the applications of experimental data in LPPs, particularly in the fields of laser-driven inertial confinement fusion and high-energy-density physics.
- Open Access
- 30 December 2025
- Published by AIP Publishing in Matter and Radiation at Extremes
- Vol. 11 (2)
Effect of intense radiation on the X-ray emission spectrum of non-LTE plasmas
Low-density non–local-thermodynamic-equilibrium plasmas in intense radiation fields occur widely in inertial confinement fusion and astrophysics. Understanding the X-ray spectrum and the atomic kinetics of such plasmas is therefore of great importance. However, the creation of uniform-density nonequilibrium plasmas in intense radiation fields in the laboratory and the measurement of their spectra with high resolution are challenging tasks. Here, we present a new method to produce such a uniform aluminum plasma and explore photon-induced kinetics and relevant atomic physics by measuring its spectrum. It is observed that in the presence of an external radiation field, the satellites q, r and a–d of the He-α resonance line are greatly enhanced compared with the satellites j, k, l. Analysis of atomic kinetics reveals that this effect of intense radiation is due to competition between the photoexcitation and autoionization processes. With this effect taken into account, simulated spectra are able to reproduce the measured spectra quite well.
- 30 December 2025
- Published by AIP Publishing in Matter and Radiation at Extremes
- Vol. 11 (2)
Open AccessEffect of intense radiation on the X-ray emission spectrum of non-LTE plasmas
Low-density non–local-thermodynamic-equilibrium plasmas in intense radiation fields occur widely in inertial confinement fusion and astrophysics. Understanding the X-ray spectrum and the atomic kinetics of such plasmas is therefore of great importance. However, the creation of uniform-density nonequilibrium plasmas in intense radiation fields in the laboratory and the measurement of their spectra with high resolution are challenging tasks. Here, we present a new method to produce such a uniform aluminum plasma and explore photon-induced kinetics and relevant atomic physics by measuring its spectrum. It is observed that in the presence of an external radiation field, the satellites q, r and a–d of the He-α resonance line are greatly enhanced compared with the satellites j, k, l. Analysis of atomic kinetics reveals that this effect of intense radiation is due to competition between the photoexcitation and autoionization processes. With this effect taken into account, simulated spectra are able to reproduce the measured spectra quite well.
- 1 June 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (6)
A large-dynamic-range high-time-resolved transmission grating spectrometer for the measurement of broadband x-ray spectrum
The temporal measurement of broadband x-ray spectrum is important for the study of x-ray sources and their applications in high-energy-density plasmas. A spectrometer with a large dynamic range is required for these measurements. In this paper, a large-dynamic-range x-ray spectrometer has been designed, in which transmission grating is coupled to an x-ray streak camera with a novel varying-width slit photocathode. Compared to a traditional fixed-width slit photocathode, the dynamic range of the spectrometer has been increased by a factor of 23. The spectral range of the spectrometer is 0.12–6.2 keV, and the temporal resolution is 40 ps. This spectrometer would be a powerful diagnostic tool for hohlraum radiation characterization and radiative ablation in inertial confinement fusion.
- 1 June 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (6)
A large-dynamic-range high-time-resolved transmission grating spectrometer for the measurement of broadband x-ray spectrum
The temporal measurement of broadband x-ray spectrum is important for the study of x-ray sources and their applications in high-energy-density plasmas. A spectrometer with a large dynamic range is required for these measurements. In this paper, a large-dynamic-range x-ray spectrometer has been designed, in which transmission grating is coupled to an x-ray streak camera with a novel varying-width slit photocathode. Compared to a traditional fixed-width slit photocathode, the dynamic range of the spectrometer has been increased by a factor of 23. The spectral range of the spectrometer is 0.12–6.2 keV, and the temporal resolution is 40 ps. This spectrometer would be a powerful diagnostic tool for hohlraum radiation characterization and radiative ablation in inertial confinement fusion.
- Open Access
- 14 May 2024
- Published by AIP Publishing in Matter and Radiation at Extremes
- Vol. 9 (4)
Measurement of 2p-3d absorption in a hot molybdenum plasma
We present measurements of the 2p-3d transition opacity of a hot molybdenum–scandium sample with nearly half-vacant molybdenum M-shell configurations. A plastic-tamped molybdenum–scandium foil sample is radiatively heated to high temperature in a compact D-shaped gold Hohlraum driven by ∼30 kJ laser energy at the SG-100 kJ laser facility. X rays transmitted through the molybdenum and scandium plasmas are diffracted by crystals and finally recorded by image plates. The electron temperatures in the sample in particular spatial and temporal zones are determined by the K-shell absorption of the scandium plasma. A combination of the IRAD3D view factor code and the MULTI hydrodynamic code is used to simulate the spatial distribution and temporal behavior of the sample temperature and density. The inferred temperature in the molybdenum plasma reaches a average of 138 ± 11 eV. A detailed configuration-accounting calculation of the n = 2–3 transition absorption of the molybdenum plasma is compared with experimental measurements and quite good agreement is found. The present measurements provide an opportunity to test opacity models for complicated M-shell configurations.
- 14 May 2024
- Published by AIP Publishing in Matter and Radiation at Extremes
- Vol. 9 (4)
Open AccessMeasurement of 2p-3d absorption in a hot molybdenum plasma
We present measurements of the 2p-3d transition opacity of a hot molybdenum–scandium sample with nearly half-vacant molybdenum M-shell configurations. A plastic-tamped molybdenum–scandium foil sample is radiatively heated to high temperature in a compact D-shaped gold Hohlraum driven by ∼30 kJ laser energy at the SG-100 kJ laser facility. X rays transmitted through the molybdenum and scandium plasmas are diffracted by crystals and finally recorded by image plates. The electron temperatures in the sample in particular spatial and temporal zones are determined by the K-shell absorption of the scandium plasma. A combination of the IRAD3D view factor code and the MULTI hydrodynamic code is used to simulate the spatial distribution and temporal behavior of the sample temperature and density. The inferred temperature in the molybdenum plasma reaches a average of 138 ± 11 eV. A detailed configuration-accounting calculation of the n = 2–3 transition absorption of the molybdenum plasma is compared with experimental measurements and quite good agreement is found. The present measurements provide an opportunity to test opacity models for complicated M-shell configurations.
- Open Access
- 29 February 2024
- Published by AIP Publishing in Matter and Radiation at Extremes
- Vol. 9 (3)
Self-consistent and precise measurement of time-dependent radiative albedo of gold based on specially symmetrical triple-cavity Hohlraum
A self-consistent and precise method to determine the time-dependent radiative albedo, i.e., the ratio of the reemission flux to the incident flux, for an indirect-drive inertial confinement fusion Hohlraum wall material is proposed. A specially designed symmetrical triple-cavity gold Hohlraum is used to create approximately constant and near-equilibrium uniform radiation with a peak temperature of 160 eV. The incident flux at the secondary cavity waist is obtained from flux balance analysis and from the shock velocity of a standard sample. The results agree well owing to the symmetrical radiation in the secondary cavity. A self-consistent and precise time-dependent radiative albedo is deduced from the reliable reemission flux and the incident flux, and the result from the shock velocity is found to have a smaller uncertainty than that from the multi-angle flux balance analysis, and also to agree well with the result of a simulation using the HYADES opacity.
- 29 February 2024
- Published by AIP Publishing in Matter and Radiation at Extremes
- Vol. 9 (3)
Open AccessSelf-consistent and precise measurement of time-dependent radiative albedo of gold based on specially symmetrical triple-cavity Hohlraum
A self-consistent and precise method to determine the time-dependent radiative albedo, i.e., the ratio of the reemission flux to the incident flux, for an indirect-drive inertial confinement fusion Hohlraum wall material is proposed. A specially designed symmetrical triple-cavity gold Hohlraum is used to create approximately constant and near-equilibrium uniform radiation with a peak temperature of 160 eV. The incident flux at the secondary cavity waist is obtained from flux balance analysis and from the shock velocity of a standard sample. The results agree well owing to the symmetrical radiation in the secondary cavity. A self-consistent and precise time-dependent radiative albedo is deduced from the reliable reemission flux and the incident flux, and the result from the shock velocity is found to have a smaller uncertainty than that from the multi-angle flux balance analysis, and also to agree well with the result of a simulation using the HYADES opacity.
- Open Access
- 29 June 2022
- Published by AIP Publishing in Matter and Radiation at Extremes
- Vol. 7 (4) , 045902
Experimental and simulation studies of thermal transport based on plasma flow motion in laser-ablated dense regions of Au and CH
A practical experimental method is proposed to investigate thermal transport by characterizing the motion of plasma flows through a x-ray spectroscopic technique using tracers. By simultaneously measuring multiple parameters, namely, the mass-ablation rate, the temporal evolution of plasma flow velocities and trajectories and the temperature, it is possible to observe a variety of physical processes, such as shock wave compression, heating by thermal waves, and plasma thermal expansion, and to determine their relative importance in different phases during the irradiation of CH and Au targets. From a comparison with hydrodynamic simulations, we find significant differences in the motion of the plasma flows between CH and Au, which can be attributed to different sensitivities to the thermal transport process. There are also differences in the ablation and electron temperature histories of the two materials. These results confirm that velocities and trajectories of plasma motion can provide useful evidence in the investigation of thermal conduction, and the approach presented here deserves more attention in the context of inertial confinement fusion and high-energy-density physics.
- 29 June 2022
- Published by AIP Publishing in Matter and Radiation at Extremes
- Vol. 7 (4) , 045902
Open AccessExperimental and simulation studies of thermal transport based on plasma flow motion in laser-ablated dense regions of Au and CH
A practical experimental method is proposed to investigate thermal transport by characterizing the motion of plasma flows through a x-ray spectroscopic technique using tracers. By simultaneously measuring multiple parameters, namely, the mass-ablation rate, the temporal evolution of plasma flow velocities and trajectories and the temperature, it is possible to observe a variety of physical processes, such as shock wave compression, heating by thermal waves, and plasma thermal expansion, and to determine their relative importance in different phases during the irradiation of CH and Au targets. From a comparison with hydrodynamic simulations, we find significant differences in the motion of the plasma flows between CH and Au, which can be attributed to different sensitivities to the thermal transport process. There are also differences in the ablation and electron temperature histories of the two materials. These results confirm that velocities and trajectories of plasma motion can provide useful evidence in the investigation of thermal conduction, and the approach presented here deserves more attention in the context of inertial confinement fusion and high-energy-density physics.
- 1 June 2021
- Published by AIP Publishing in Physics of Plasmas
- Vol. 28 (6) , 062707
Multi-keV x-ray radiator from titanium cylindrical cavity at the Shenguang-III prototype laser facility
Great efforts have been made to create a bright K-shell source using the thin metal cylindrical cavities in the past few decades. Several metal materials such as titanium (Ti), iron, and so on have been tested for high x-ray conversion efficiency mainly at the OMEGA and NIF laser facilities. Recently, x-ray sources in Ti K-shell transition energy range were investigated at the Shenguang-III prototype laser facility with ∼5 kJ laser energy. The experiments were aimed to reproduce the previous ones at OMEGA, but with an extraordinarily small volume of cylindrical cavity and detailed characterizations of the x-ray source. The cavities were 800 μm inner diameter, 800 μm length, and 30 μm thick plastic tubes supporting 1 μm thick Ti. Seven laser beams were focused to 200 μm diameter. The combination of the small cavity volume and the focused laser spots is intended to improve the electron temperature with limited laser energy since the electron temperature is a key issue for high x-ray conversion efficiency. Thomson scattering was adopted to experimentally probe the electron temperatures at special time and space zones as well as the average temperature obtained from the Ti K-shell spectrum. The evolutions of the electron temperature and density are predicted by the radiation hydrodynamic simulation. A top view and two photon energy bands of x-ray source images provide a way to directly observe the plasma movement toward the cavity axis and distinguish the different emission mechanisms between the Ti K-shell and lower energy x rays. Six Higher-energy x-ray detectors located at different angles were used to record the Ti K-shell x-ray emission and demonstrate its isotropic feature. The characteristics of the x-ray radiate intensity including the time evolution, the angular distribution, and the total yields for both the photon energy regions above and below 4 keV are compared between the cavity and planar targets. Obviously, different behaviors were found between the two photon energy regions and the two types of targets. The x-ray conversion efficiency of the Ti cylinder was determined to be and in sr in the Ti K-shell (4–7 keV) and <4 keV range, respectively. The Ti K-shell conversion efficiency obtained in the present experiments is between the ones driven by 13.5 and 4.5 kJ laser energy at OMEGA.- 1 June 2021
- Published by AIP Publishing in Physics of Plasmas
- Vol. 28 (6) , 062707
Multi-keV x-ray radiator from titanium cylindrical cavity at the Shenguang-III prototype laser facility
Great efforts have been made to create a bright K-shell source using the thin metal cylindrical cavities in the past few decades. Several metal materials such as titanium (Ti), iron, and so on have been tested for high x-ray conversion efficiency mainly at the OMEGA and NIF laser facilities. Recently, x-ray sources in Ti K-shell transition energy range were investigated at the Shenguang-III prototype laser facility with ∼5 kJ laser energy. The experiments were aimed to reproduce the previous ones at OMEGA, but with an extraordinarily small volume of cylindrical cavity and detailed characterizations of the x-ray source. The cavities were 800 μm inner diameter, 800 μm length, and 30 μm thick plastic tubes supporting 1 μm thick Ti. Seven laser beams were focused to 200 μm diameter. The combination of the small cavity volume and the focused laser spots is intended to improve the electron temperature with limited laser energy since the electron temperature is a key issue for high x-ray conversion efficiency. Thomson scattering was adopted to experimentally probe the electron temperatures at special time and space zones as well as the average temperature obtained from the Ti K-shell spectrum. The evolutions of the electron temperature and density are predicted by the radiation hydrodynamic simulation. A top view and two photon energy bands of x-ray source images provide a way to directly observe the plasma movement toward the cavity axis and distinguish the different emission mechanisms between the Ti K-shell and lower energy x rays. Six Higher-energy x-ray detectors located at different angles were used to record the Ti K-shell x-ray emission and demonstrate its isotropic feature. The characteristics of the x-ray radiate intensity including the time evolution, the angular distribution, and the total yields for both the photon energy regions above and below 4 keV are compared between the cavity and planar targets. Obviously, different behaviors were found between the two photon energy regions and the two types of targets. The x-ray conversion efficiency of the Ti cylinder was determined to be and in sr in the Ti K-shell (4–7 keV) and <4 keV range, respectively. The Ti K-shell conversion efficiency obtained in the present experiments is between the ones driven by 13.5 and 4.5 kJ laser energy at OMEGA.- Open Access
- 29 December 2015
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 816 (1) , 36
OPACITY MEASUREMENT AND THEORETICAL INVESTIGATION OF HOT SILICON PLASMA
We report on opacity measurements of a silicon (Si) plasma at a temperature of (72 ± 5) eV and a density of (6.0 ± 1.2) mg cm−3 in the photon energy range of 1790–1880 eV. A 23 μg cm−2 Si foil tamped by 50 μg cm−2 CH layers on each side was heated to a hot-dense plasma state by X-ray radiation emitted from a D-shaped gold cavity that was irradiated by intense lasers. Absorption lines of 1s − 2p transitions of Si xiii to Si ix ions have been measured using point-projection spectroscopy. The transmission spectrum of the silicon plasma was determined by comparing the light passing through the plasma to the light from the same shot passing by the plasma. The density of the Si plasma was determined experimentally by side-on radiography and the temperature was estimated from the radiation flux data. Radiative hydrodynamic simulations were performed to obtain the temporal evolutions of the density and temperature of the Si plasma. The experimentally obtained transmission spectra of the Si sample plasma have been reproduced using a detailed term account model with the local thermodynamic equilibrium approximation. The energy levels, oscillator strengths and photoionization cross-sections used in the calculation were generated by the flexible atomic code. The experimental transmission spectrum was compared with the theoretical calculation and good agreement was found. The present experimental spectrum and theoretical calculation were also compared with the new opacities available in the Los Alamos OPLIB database.
- 29 December 2015
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 816 (1) , 36
Open AccessOPACITY MEASUREMENT AND THEORETICAL INVESTIGATION OF HOT SILICON PLASMA
We report on opacity measurements of a silicon (Si) plasma at a temperature of (72 ± 5) eV and a density of (6.0 ± 1.2) mg cm−3 in the photon energy range of 1790–1880 eV. A 23 μg cm−2 Si foil tamped by 50 μg cm−2 CH layers on each side was heated to a hot-dense plasma state by X-ray radiation emitted from a D-shaped gold cavity that was irradiated by intense lasers. Absorption lines of 1s − 2p transitions of Si xiii to Si ix ions have been measured using point-projection spectroscopy. The transmission spectrum of the silicon plasma was determined by comparing the light passing through the plasma to the light from the same shot passing by the plasma. The density of the Si plasma was determined experimentally by side-on radiography and the temperature was estimated from the radiation flux data. Radiative hydrodynamic simulations were performed to obtain the temporal evolutions of the density and temperature of the Si plasma. The experimentally obtained transmission spectra of the Si sample plasma have been reproduced using a detailed term account model with the local thermodynamic equilibrium approximation. The energy levels, oscillator strengths and photoionization cross-sections used in the calculation were generated by the flexible atomic code. The experimental transmission spectrum was compared with the theoretical calculation and good agreement was found. The present experimental spectrum and theoretical calculation were also compared with the new opacities available in the Los Alamos OPLIB database.