    Determining the dynamics of electromagnetic fields, air ionization, low-frequency sound and their normalization in premises for computer equipment

    by Valentyn Glyva, Natalia Kasatkina, Larysa Levchenko, Oksana Tykhenko, Vasyl Nazarenko, Nataliia Burdeina, Olena Panova, Mariia Bahrii, Kyrylo Nikolaiev, Yana Biruk

    This paper reports a study into the quantitative values and dynamics of physical factors in premises and workplaces of stationary and portable computers. The factors that are practically not perceived by the senses of operators were investigated. It is established that modern monitors do not generate electromagnetic fields of hygienically significant levels. System units generate electric fields (18‒22 V/m) and magnetic fields (220‒245 nT) that are approaching the maximum permissible. Sources of uninterruptible power supply and fluorescent lighting systems generate excess magnetic fields (up to 2250 nT and 2300 nT), respectively. The main excessive factor for portable computers is electric fields (up to 9 kV/m), which is the cause of air deionization in the user's zone of stay. It is shown that one system unit in the normative volume of the room (20 m3) deionizes air (into 100 cm-3 positive and 200 cm-3 negative). The generation of ions by modernized laser printers and photocopiers of various models (up to 1500 cm-3 and 2800 cm-3, respectively) was investigated. The distances at which the ionic composition of the air corresponds to the background values (1.0‒1.5 m) were determined. That requires the introduction of artificial air ionization in workplaces of users and a decrease in the levels of electrostatic fields. The spectral composition and amplitudes of magnetic fields of external power supplies of laptop computers were determined. It is shown that the difference in sound levels measured on the scales "Lin" and "A" reaches 24 dB, which indicates a significant impact of infrasound on users. Membrane-type protective panels configured for maximum resonant frequencies of low-frequency sound and infrasound have been proposed


  • Open Access

    FORECASTING THE AEROIN COMPOSITION OF AIR IN THE PRESENCE OF NATURAL AND ARTIFICIAL SOURCES OF IONIZATION

    by V. Frolov, O. Panova, S. Zozulya

    It is shown that for the design of buildings and individual rooms with normative concentrations of light air ions of both polarities, a preliminary estimated assessment of the dynamics of this indicator in space and time is appropriate. In the general case, it is possible to use the continuity equation for weakly ionized plasma for one direction. This is due to the low concentration of air ions in the air. The ratio of molecular kinetic theory of gases is used to determine the necessary indicators - the average lifetime of air ions, free path length. To determine the average speed - Maxwell's distribution. It is shown that the propagation of air ions due to diffusion processes is insignificant, and the corresponding calculations have large errors. Calculations on the propagation of air ions by directed air movement from the source of artificial ionization are given. The distribution of air ion concentrations can be most accurately calculated taking into account their recombination, deposition on heavy air ions and neutral suspended parts (fine dust and aerosols). Relevant coefficients are mostly issued from reference sources. If there are electrostatic fields in the premises, generated due to the triboelectric effect and other factors, it is necessary to take into account the deposition of air ions on these surfaces. In order to correctly determine the concentrations of air ions, in addition to the values of the mobility of negative and positive air ions, data on electrostatic field strengths are required. The values of such fields are unpredictable, so they are measured by appropriate instruments in similar conditions. Verification of calculated data using electrostatic charge meters and air ion counter proved the reasonable convergence of expected and actual data. It is advisable to develop two- and three-dimensional models of the propagation of air ions of both polarities in rooms of different purposes, configurations of equipment placement, the presence of artificial ionization sources and directional air movement.

  • Open Access

    Monitoring and management ion concentrations in the air of industrial and public premises

    by Borys Bolibrukh, Valentyn Glyva, Natalia Kasatkina, Larysa Levchenko, Oksana Tykhenko, Olena Panova, Oleg Bogatov, Tetiana Petrunok, Iryna Aznaurian, Sergey Zozulya

    This paper reports a substantiated method and a designed device for controlling the concentrations of air ions in premises in accordance with the European standards SBM 2015. The use of an ultrasonic humidifier with a capacity of 25 W for two hours increases the concentration of negative ions around the device from 240 to 560 cm-3, positive ones ‒ from 260 to 410 cm-3. The intensity of the electrostatic field of a polymeric coating decreases from 5.1 to 0.2 kV/m. The disadvantage of the humidifier is a small radius of influence (1.0–1.5 m) and the inability to control the polarity of ions. It has been experimentally established that air cooling systems (split systems) deionize the air of the premises. Degrees of deionization and dominating polarity are unpredictable and different for devices of different manufacturers and brands. To control the ion composition of the air simultaneously with the maintenance of normative relative humidity and stresses of static fields, the structure was proposed and the effectiveness of a bipolar ultrasonic air ionizer with adjusted performance and dominating polarity has been tested. The maximum productivity of the ionizer is 4,000–5,000 cm-3. The radius of exposure is 5 m (reducing the concentration of ions with a distance to 500 cm-3). To pass the ionized air through an air capacitor, the number and predominant polarity of air ions are regulated by the polarity and voltage on the covers of the capacitor. It was established that in order to service a room with an area of 50 m2, an ultrasonic emitter with a capacity of 25 W would suffice. The adjustability of the device performance makes it possible to reduce or increase the service area. The ability to purify air from suspended particles is shown. During the two hours of operation of the ionizer, the dust content decreased from 4.3–4.4 mg/m3 to 1.4–1.6 mg/m3.


  • Open Access

    EVALUATION OF ELECTROMAGNETIC RADIATION SHIELDING CHARACTERISTICS OF FACING BUILDING VATERIALS

    by Olena Panova, Grigory Krasnyansky, Irina Aznauryan

    Представлено результати теоретичних досліджень захисних властивостей композиційних облицювальних матеріалів на основі діелектричної матриці з немагнітним електропровідним наповнювачем у широкому діапазоні частот падаючого електромагнітного випромінювання. Отримано вирази для величин проходження, відбиття та поглинання і розрахованої на їх основі ефективності екранування електромагнітного випромінювання матеріалом. Необхідні для розрахунків залежності діелектричної проникності та електро-провідності композиту від об'ємної частки електропровідної добавки отримано на підставі гіпотези подібності при врахуванні ненульової провідності діелектричної матриці. Встановлено задовільну відповідність результатів розрахунків із виміряними характеристиками екранування зразків металосилікатних матеріалів на основі гідросилікатів кальцію та мідного порошку. Загалом наведені результати показують адекватність запропонованої розрахункової методики і свідчать, що вона може бути використана для попередніх оцінок характеристик екранування при проєктуванні електромагнітних екранів на основі композиційних облицювальних матеріалів.

  • CURRENT PROBLEMS OF NORMALIZATION OF PHYSICAL FACTORS IN THE OPERATION OF COMPUTER EQUIPMENT

    by O. Panova

    Analysis of national and international databases on the safety of physical factors. Non-regulatory working conditions of computer users are largely due to the lack of national sanitary norms and rules for the safe operation of computer equipment. Current international standards relate to the radiative properties of technical means and do not consider the conditions in the workplace. It is shown that general standards on maximum permissible levels of physical factors are unacceptable for their application in the field of user safety due to high maximum permissible levels of electromagnetic fields, infrasound, electrostatic fields, etc. In addition, there are significant differences in the various current regulations regarding limit levels and methods for determining the integrated electromagnetic load. When developing sanitary norms for the safety of users of computer equipment, the dependence of air quality on the aeroionic composition on the presence of surface electrophysical charges on polymer surfaces and models of technical means and means of air cooling should be taken into account. It is advisable to regulate the use of artificial air ionization devices. Given the relatively low levels of electromagnetic fields in the workplace of users, it is necessary to regulate the ways of controlling the levels of electromagnetic fields with acceptable errors. Given the impact of unstable operation of technical ways on the psychomatic state of users in the process of developing the relevant standard, it is necessary to take into account the stable operation of equipment by increasing the levels of electromagnetic compatibility of equipment.

  • RESEARCH OF AIR IONIZATION OF AIR IN PREMISES ON OPERATION OF COMPUTER EQUIPMENT

    by O. Panova, L. Levchenko, I. Teslytsky

    All known studies on the effect of computer equipment on the concentration of air ions of both signs have been used for rooms where desktop computers are operated. The expediency of conducting research using a laptop computer is substantiated. Therefore, the urgent task is to study the dynamics of the air ionic composition of the air from the operation of personal computers and identify ways to maintain this indicator at the regulatory level. It is shown that the switched on computer deionizes air, and mainly on one polarity. It is established that this is a consequence of electrification of polymer surfaces. The cause of electrification is triboelectric phenomena, including the directional movement of dry air from the CPU cooling fan. Additional electrification (and consequently - deionization of air) gives the presence of the user. Confirmation of the cause of deionization is the slow recovery of the concentration of air ions after turning on the computer to a certain neutralization of surface charges. The dependences of the change of air ion concentrations on the distance from the electric field source are established. At its intensity of about 5 kV/m with dimensions of 1.0×1.0 m, the critical distance is 1.2-1.3 m. It is recommended to carry out wet absorption for an unambiguous workplace, which provides insignificant electric fields for 1.5 hours. During the operation of many personal computers, it is advisable to neutralize surface charges with an ultrasonic humidifier-ionizer. It is emphasized that the conducted research has a separate character. This is due to the presence of specific synthetic materials It is advisable to conduct research in standard rooms for the operation of computer equipment to obtain information that can be summarized and used to develop sanitary standards for the operation of computer equipment.

  • Open Access

    Design of liquid composite materials for shielding electromagnetic fields

    by Valentyn Glyva, Volodymyr Bakharev, Natalia Kasatkina, Oleg Levchenko, Larysa Levchenko, Nataiia Burdeina, Sergii Guzii, Olena Panova, Oksana Tykhenko, Yana Biruk

    This paper reports the principles of design and the examined protective properties of liquid materials for shielding the electric, magnetic, and electromagnetic fields over a wide frequency range. The materials were made on the basis of iron ore concentrate and a pigment additive, with water-dispersed and geopolymer paints used as a matrix. The tests of protective properties for the electrical and magnetic components of the electromagnetic field of industrial frequency showed that the electric field shielding coefficients at a concentration of the screening substance of 15−60 % (by weight) equaled 1.1−8.6; magnetic field – 1.2−5.3. The shielding coefficients of the material based on a water-dispersed paint are lower than those of a geopolymer one, which can be explained by the oxidation of an iron-containing component and a decrease in electrical conductivity. The shielding coefficients of the electromagnetic field with a frequency of 2.45 GHz are 1.2−7.9. The highest coefficients are inherent in the material with filler made of iron ore concentrate and titanium-containing pigment powder in a ratio of 1:1. To design materials with the required (predictable) protective properties, the relative magnetic, dielectric permeability of materials was calculated. It is shown that the obtained data are acceptably the same as the results from direct measurements of magnetic and dielectric permeability and could be used to calculate the wave resistance of the material and the predicted reflection coefficient of electromagnetic waves. Thus, there is reason to assert the need to build a database on the frequency dependence of effective magnetic and dielectric permeability in order to automate the design processes of composite materials with predefined protective properties.


  • Open Access

    INVESTIGATION OF THE LATEST COATINGS WITH SHIELDING PROPERTIES OF ITS OWN PRODUCTION

    by Olena Panova, Yana Biruk, Oleg Besarab, Yan Kormilitsyn

    In the modern world, protection against the influence of man-made electromagnetic fields shielding will be increasingly used. In the transition to international standards (in various industries) in the manufacture of the latest facing and finishing materials, the most promising and demanded building materials with shielding properties. Reducing weight due to the thickness of the shielding coating of building material is not always expedient and is not always allowed by the relevant state and international sanitary norms. Theoretical calculations on this issue or mathematical forecasting minimize the cost of manufacturing the substance of the shielding material, and in general, reduce the total number of measurements to their confirmation. The presented methodology enables to predict protective properties, depending on the parameters of fields that need shielding. The purpose of the study is – the manufacture of the latest coatings of composite structures to predict the protective properties of building materials in a wide frequency range. Methods and methods of research – improvement of the development of a new shielding material by producing metal-polymer material for shielding physical fields and developing a technology for increasing the distribution of shielding particles in the body of a polymeric material (matrix), preventing particle adhesion and increase their dispersion.

  • Open Access

    METHODOLOGY OF DETERMINATION OF ELECTROMAGNETIC TECHNOGENIC LOAD AND WAYS OF THEIR IMPROVEMENT

    by Olena Panova, Yana Biruk

    The subject of research is the processes of formation of man - made electromagnetic load at the enterprise under the influence of external and internal fields. The purpose of the work - to develop a modern algorithm for estimating the electromagnetic load at the enterprise and provide recommendations for the introduction of means of protection of workers without large economic losses. To solve this goal, approaches and methods of theoretical research were used, which are based on the fundamental principles of classical physics and systems analysis. The paper shows that the development of an algorithm for estimating man -made electromagnetic load at the enterprise depends on the identification of man - made fields and determining their spatial propagation (taking into account the prediction of the effects of edge effects) is a necessary general complex for further professional shielding at the enterprise. It is concluded that the presented algorithm for estimating man-made electromagnetic load at the enterprise and the described recommendations for implementation solve the main issue - forecasting protective properties, which simplifies further selection of technical methods of protection of workers, individual workplace or sensitive electronic device or enterprise as a whole.

  • Open Access

    Studying the shielding of an electromagnetic field by a textile material containing ferromagnetic nanostructures

    by Valentyn Glyva, Oleg Barabash, Natalia Kasatkina, Mykhailo Katsman, Larysa Levchenko, Oksana Tykhenko, Kyrylo Nikolaiev, Olena Panova, Batyr Khalmuradov, Oleksiy Khodakovskyy

    Studying the shielding of an electromagnetic field by a textile material containing ferromagnetic nanostructures