Valentyn Glyva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Valentyn Glyva has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Nataliia Burdeina
Kyiv National University of Construction and Architecture
13 shared publications - Larysa Levchenko
National Technical University of Ukraine «Igor Sikorsky Kyiv Polytechnic Institute», Kyiv
11 shared publications - Oksana Tykhenko
National Aviation University
8 shared publications - Yana Biruk
Kyiv National University of Construction and Architecture
8 shared publications - Natalia Kasatkina
National University of Food Technologies, Ukraine
6 shared publications - V. I. Nazarenko
State Institution "Kundiiev Institute of Occupational Health of the National Academy of Medical Sciences of Ukraine", Ukraine
6 shared publications
Latest Publications
- Open Access
- 30 October 2025
- Published by Kyiv National University of Construction and Architecture in Strength of Materials and Theory of Structures
- No. 115
Theoretical and experimental principles of designing sound insulation of buildings and structure
The principles of designing sound insulation of buildings and structures using materials of different physical characteristics are developed. The possibilities of simplifying sound insulation calculations for small values of the phase velocities of bending waves in the surface material are shown. It is shown that such a condition corresponds to small values of sound frequencies compared to the critical frequency of the surface. The limits of the acceptable error of calculations are determined, taking into account mainly resonant and inertial sound absorption. These limits roughly correspond to the sound frequencies f < 0,5fc, 0,5fc < f < 1,2fc and f > 1,2fc, fc being the critical surface frequency of these mass and dimensional parameters. The mathematical functions for calculating the sound insulation of surfaces made of soft materials are obtained. The values of the response functions of surfaces of different sizes are determined. It is shown that for frequencies above 300–400 Hz, the response function approaches unity and can be ignored. This conclusion is confirmed by experimental data, which have an acceptable agreement with the calculations. This greatly simplifies the practical design of soundproof structures. The principles of designing a two-layer structure to improve sound insulation are determined. It was found that sound insulation increases with an increase in the gap between the surfaces. However, at distances greater than 7-8·10-2 m, there is no increase in sound insulation, so an increase in the overall dimensions of soundproof structures is impractical.
- 30 October 2025
- Published by Kyiv National University of Construction and Architecture in Strength of Materials and Theory of Structures
- No. 115
Open AccessTheoretical and experimental principles of designing sound insulation of buildings and structure
The principles of designing sound insulation of buildings and structures using materials of different physical characteristics are developed. The possibilities of simplifying sound insulation calculations for small values of the phase velocities of bending waves in the surface material are shown. It is shown that such a condition corresponds to small values of sound frequencies compared to the critical frequency of the surface. The limits of the acceptable error of calculations are determined, taking into account mainly resonant and inertial sound absorption. These limits roughly correspond to the sound frequencies f < 0,5fc, 0,5fc < f < 1,2fc and f > 1,2fc, fc being the critical surface frequency of these mass and dimensional parameters. The mathematical functions for calculating the sound insulation of surfaces made of soft materials are obtained. The values of the response functions of surfaces of different sizes are determined. It is shown that for frequencies above 300–400 Hz, the response function approaches unity and can be ignored. This conclusion is confirmed by experimental data, which have an acceptable agreement with the calculations. This greatly simplifies the practical design of soundproof structures. The principles of designing a two-layer structure to improve sound insulation are determined. It was found that sound insulation increases with an increase in the gap between the surfaces. However, at distances greater than 7-8·10-2 m, there is no increase in sound insulation, so an increase in the overall dimensions of soundproof structures is impractical.
- 31 December 2024
- Published by Kundiiev Institute of Occupational Health of National Academy of Medical Sciences of Ukraine in Ukrainian Journal of Occupational Health
- Vol. 2024 (4) , 301-310
Influence of the electrostatic field on workers and measures regarding its normalization in office and production premises
Influence of the electrostatic field on workers and measures regarding its normalization in office and production premises: ISSN 2223-6775 Ukrainian journal of occupational health Vol.20, No 4, 2024 https://doi.org/10.33573/ujoh2024.04.301 Influence of the electrostatic field on workers and measures regarding its normalization in office and production premises Nazarenko V.I.1)
- 31 December 2024
- Published by Kundiiev Institute of Occupational Health of National Academy of Medical Sciences of Ukraine in Ukrainian Journal of Occupational Health
- Vol. 2024 (4) , 301-310
Influence of the electrostatic field on workers and measures regarding its normalization in office and production premises
Influence of the electrostatic field on workers and measures regarding its normalization in office and production premises: ISSN 2223-6775 Ukrainian journal of occupational health Vol.20, No 4, 2024 https://doi.org/10.33573/ujoh2024.04.301 Influence of the electrostatic field on workers and measures regarding its normalization in office and production premises Nazarenko V.I.1)
- Open Access
- 30 December 2024
- Published by Kyiv National University of Construction and Architecture in Transfer of innovative technologies
- Vol. 7 (1) , 11-19
CORROSION AND ELECTROMAGNETIC SHIELDING PROPERTIES OF POWDER PAINT COATINGS PREPARED FROM GALVANIC WASTE
This work is focused on the study of the properties of powder paint coatings modified with fillers, which are obtained from ferritization waste processing of spent technological solutions of galvanic industries. The physical, mechanical and shielding properties of powder systems with iron-containing products introduced into their composition were investigated in the work. It is shown that the use of iron-containing waste in general contributes to the increase of both mechanical characteristics and corrosion resistance of coatings. It was determined that the introduction of Ni0.5Cu0.5Fe2O4 and Zn0.5Cu0.5Fe2O4 into the composition allows to significantly increase their mechanical and shielding properties
- 30 December 2024
- Published by Kyiv National University of Construction and Architecture in Transfer of innovative technologies
- Vol. 7 (1) , 11-19
Open AccessCORROSION AND ELECTROMAGNETIC SHIELDING PROPERTIES OF POWDER PAINT COATINGS PREPARED FROM GALVANIC WASTE
This work is focused on the study of the properties of powder paint coatings modified with fillers, which are obtained from ferritization waste processing of spent technological solutions of galvanic industries. The physical, mechanical and shielding properties of powder systems with iron-containing products introduced into their composition were investigated in the work. It is shown that the use of iron-containing waste in general contributes to the increase of both mechanical characteristics and corrosion resistance of coatings. It was determined that the introduction of Ni0.5Cu0.5Fe2O4 and Zn0.5Cu0.5Fe2O4 into the composition allows to significantly increase their mechanical and shielding properties
- Open Access
- 29 November 2024
- Published by Kyiv National University of Construction and Architecture in Strength of Materials and Theory of Structures
- No. 113,p. 329-336
Modelling the thermal resistance of layered structures for blocking infrared radiation
Ensuring high thermal resistance of building, cladding, finishing and other materials helps to solve the problems of energy efficiency of buildings and energy saving in general. Typically, building and cladding structures have several layers. This makes it difficult to predict their heat transfer. To solve these problems, it is proposed to model the thermal resistance of layered structures. The mathematical functions that should be used in modelling are determined. In particular, the mechanisms of heat transfer due to thermal conductivity and radiant heat transfer are separated. The assumptions and simplifications in the calculations that are acceptable in terms of errors are determined. The use of glass fibres for blocking infrared radiation is theoretically substantiated. The thermal resistance of a layered structure with an arbitrary number of layers and different thermal properties of each layer was modelled. The modelling was carried out using COMSOL tools. Changes in the thermal state of the layered structure in space and time were obtained. The modelling results were verified. Samples of materials based on glass fibre were manufactured and tested using a standard thermal imager. It was found that such a three-layer glass fibre material actually completely blocks infrared radiation at an initial temperature of up to 40 °С. Comparison of the results with the efficiency of a standard thermal insulation product shows that the predominant mechanism for blocking infrared radiation in a glass fibre-based product is the scattering of infrared radiation. This opens up the possibility of using glass fibre fabrics both to increase the thermal resistance of building and finishing materials and to produce infrared camouflage.
- 29 November 2024
- Published by Kyiv National University of Construction and Architecture in Strength of Materials and Theory of Structures
- No. 113,p. 329-336
Open AccessModelling the thermal resistance of layered structures for blocking infrared radiation
Ensuring high thermal resistance of building, cladding, finishing and other materials helps to solve the problems of energy efficiency of buildings and energy saving in general. Typically, building and cladding structures have several layers. This makes it difficult to predict their heat transfer. To solve these problems, it is proposed to model the thermal resistance of layered structures. The mathematical functions that should be used in modelling are determined. In particular, the mechanisms of heat transfer due to thermal conductivity and radiant heat transfer are separated. The assumptions and simplifications in the calculations that are acceptable in terms of errors are determined. The use of glass fibres for blocking infrared radiation is theoretically substantiated. The thermal resistance of a layered structure with an arbitrary number of layers and different thermal properties of each layer was modelled. The modelling was carried out using COMSOL tools. Changes in the thermal state of the layered structure in space and time were obtained. The modelling results were verified. Samples of materials based on glass fibre were manufactured and tested using a standard thermal imager. It was found that such a three-layer glass fibre material actually completely blocks infrared radiation at an initial temperature of up to 40 °С. Comparison of the results with the efficiency of a standard thermal insulation product shows that the predominant mechanism for blocking infrared radiation in a glass fibre-based product is the scattering of infrared radiation. This opens up the possibility of using glass fibre fabrics both to increase the thermal resistance of building and finishing materials and to produce infrared camouflage.
- Open Access
- 27 September 2024
- Published by Kyiv National University of Construction and Architecture in Spatial development
- No. 9,p. 163-174
IMPROVEMENT OF THE METHODOLOGY FOR OBTAINING BASELINE DATA TO RATIONALISE THE EFFECTIVENESS OF SHIELDING PHYSICAL FIELDS
The shortcomings of the current regulatory framework for obtaining initial data for the design of materials and structures for shielding electromagnetic and acoustic fields are identified. It is shown that in order to obtain reliable data by the method of field measurements, it is necessary to be guided by the maximum basic error of the equipment. The calculations of the total electromagnetic field differ in the two existing acts on electromagnetic safety. They give different results, which complicates design work and forces the use of over-efficiency protection. It is necessary to harmonise national and international standards for determining the electromagnetic load on people. Currently, Ukraine lacks a metrological and methodological framework for determining the specific absorbed energy and specific absorbed power of an electromagnetic field. Only resonant structures are effective for protection against low-frequency sound and infrasound. To obtain information about the frequencies of maximum amplitudes that are selected as resonant, it is necessary to measure the previous vibration spectrum. But this is not provided for by the current standards.
- 27 September 2024
- Published by Kyiv National University of Construction and Architecture in Spatial development
- No. 9,p. 163-174
Open AccessIMPROVEMENT OF THE METHODOLOGY FOR OBTAINING BASELINE DATA TO RATIONALISE THE EFFECTIVENESS OF SHIELDING PHYSICAL FIELDS
The shortcomings of the current regulatory framework for obtaining initial data for the design of materials and structures for shielding electromagnetic and acoustic fields are identified. It is shown that in order to obtain reliable data by the method of field measurements, it is necessary to be guided by the maximum basic error of the equipment. The calculations of the total electromagnetic field differ in the two existing acts on electromagnetic safety. They give different results, which complicates design work and forces the use of over-efficiency protection. It is necessary to harmonise national and international standards for determining the electromagnetic load on people. Currently, Ukraine lacks a metrological and methodological framework for determining the specific absorbed energy and specific absorbed power of an electromagnetic field. Only resonant structures are effective for protection against low-frequency sound and infrasound. To obtain information about the frequencies of maximum amplitudes that are selected as resonant, it is necessary to measure the previous vibration spectrum. But this is not provided for by the current standards.
- Open Access
- 30 April 2024
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 2 (10 (128)) , 26-33
Study of air deionization factors
The object of research is the dynamics in the concentration of air ions and suspended particles in atmospheric air and in supply-exhaust ventilation systems. An urgent task is to determine the factors and obtain quantitative data on the deionization of the atmospheric air that enters the environment where people live. Quantitative data on changes in the concentration of air ions depending on the time of day, temperature, and relative air humidity have been established. It was shown that even in the absence of significant man-made influence on the concentration of suspended particles, this indicator is at least 7000 cm-3. In the presence of wind, this indicator reaches 30000 cm-3 and higher. Measurement of the spectrum of suspended particles in the range of 0,3–6,0 μm showed that the predominant fraction is particles with sizes of about 3 μm. Studies have been conducted on changes in the concentrations of air ions in supply-exhaust ventilation systems. It was established that in the air duct made of galvanized iron, which has a length of 16 m, the concentration of negative air ions is reduced by 67 %, and positive by 78 %. Laboratory studies of air deionization in air ducts made of different materials were carried out. There is significant air deionization in metal and cardboard ducts while it is absent in wooden ducts. This indicates the electrical nature of deionization. A calculation method for forecasting the aero-ionic mode of premises, taking into account the factors of air deionization, is proposed. For rooms with supply-exhaust ventilation, a calculation apparatus is proposed taking into account the air exchange rate (the number of complete air changes per unit of time). The results make it possible to choose the required performance of artificial air ionization devices for normalizing the aero-ionic regimes in the premises
- 30 April 2024
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 2 (10 (128)) , 26-33
Open AccessStudy of air deionization factors
The object of research is the dynamics in the concentration of air ions and suspended particles in atmospheric air and in supply-exhaust ventilation systems. An urgent task is to determine the factors and obtain quantitative data on the deionization of the atmospheric air that enters the environment where people live. Quantitative data on changes in the concentration of air ions depending on the time of day, temperature, and relative air humidity have been established. It was shown that even in the absence of significant man-made influence on the concentration of suspended particles, this indicator is at least 7000 cm-3. In the presence of wind, this indicator reaches 30000 cm-3 and higher. Measurement of the spectrum of suspended particles in the range of 0,3–6,0 μm showed that the predominant fraction is particles with sizes of about 3 μm. Studies have been conducted on changes in the concentrations of air ions in supply-exhaust ventilation systems. It was established that in the air duct made of galvanized iron, which has a length of 16 m, the concentration of negative air ions is reduced by 67 %, and positive by 78 %. Laboratory studies of air deionization in air ducts made of different materials were carried out. There is significant air deionization in metal and cardboard ducts while it is absent in wooden ducts. This indicates the electrical nature of deionization. A calculation method for forecasting the aero-ionic mode of premises, taking into account the factors of air deionization, is proposed. For rooms with supply-exhaust ventilation, a calculation apparatus is proposed taking into account the air exchange rate (the number of complete air changes per unit of time). The results make it possible to choose the required performance of artificial air ionization devices for normalizing the aero-ionic regimes in the premises
- 25 December 2023
- Published by Kundiiev Institute of Occupational Health of National Academy of Medical Sciences of Ukraine in Ukrainian Journal of Occupational Health
- Vol. 2023 (4) , 285-293
Light pulsation coefficient in workplaces with visual means of displaying information and ways of its normalization
Light pulsation coefficient in workplaces with visual means of displaying information and ways of its normalization: ISSN 2223-6775 Ukrainian journal of occupational health Vol.19, No 4, 2023https://doi.org/10.33573/ujoh2023.04 Light pulsation coefficient in workplaces with visual means of displaying information and ways of its normalization Nazarenko V.I.1, Glyva V.A.2
- 25 December 2023
- Published by Kundiiev Institute of Occupational Health of National Academy of Medical Sciences of Ukraine in Ukrainian Journal of Occupational Health
- Vol. 2023 (4) , 285-293
Light pulsation coefficient in workplaces with visual means of displaying information and ways of its normalization
Light pulsation coefficient in workplaces with visual means of displaying information and ways of its normalization: ISSN 2223-6775 Ukrainian journal of occupational health Vol.19, No 4, 2023https://doi.org/10.33573/ujoh2023.04 Light pulsation coefficient in workplaces with visual means of displaying information and ways of its normalization Nazarenko V.I.1, Glyva V.A.2
- Open Access
- 31 August 2023
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 4 (10 (124)) , 6-14
Identifying regularities in the propagation of air ions in rooms with artificial air ionization
The object of the study is the dynamics of air ion spread in rooms from the source of artificial air ionization under different starting conditions. There is currently the problem of distribution of air ions in the room with regulatory concentrations in all critical zones. An effective method of ensuring proper air ion concentrations is to model their propagation from ionization sources. Existing approaches to calculating the dynamics of air ions of both polarities have been improved in this study. Unlike known solutions, the impact on their concentration of electrostatic field and the interaction of air ions with suspended particles was taken into account. A model of air ion propagation in rooms with artificial air ionization and the principles of its numerical modeling was built. The use of Laplace Equation in the aerodynamic model instead of the Navier-Stokes equation for the potential of the flow rate has made it possible to design an "Ion 3D" tool, which reduces the time of implementation of one scenario from several hours to 7 seconds. Modeling of the propagation of air ions of both polarities in the room under different initial conditions was carried out. Two-dimensional and three-dimensional models with their visualization was implemented. The peculiarity of the resulting models is that they make it possible to determine the concentrations of air ions in any section of the room by three coordinates. Given this, the rapid selection of the variants of the source data makes it possible to achieve the normative values of concentrations of air ions in the area of breathing – exceeding 500 cm-3 of each polarity. Simulation makes it possible to design a room in which, under the condition of artificial ionization of air, the concentrations of air ions close to the optimal values of 3000–5000 cm-3 are provided
- 31 August 2023
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 4 (10 (124)) , 6-14
Open AccessIdentifying regularities in the propagation of air ions in rooms with artificial air ionization
The object of the study is the dynamics of air ion spread in rooms from the source of artificial air ionization under different starting conditions. There is currently the problem of distribution of air ions in the room with regulatory concentrations in all critical zones. An effective method of ensuring proper air ion concentrations is to model their propagation from ionization sources. Existing approaches to calculating the dynamics of air ions of both polarities have been improved in this study. Unlike known solutions, the impact on their concentration of electrostatic field and the interaction of air ions with suspended particles was taken into account. A model of air ion propagation in rooms with artificial air ionization and the principles of its numerical modeling was built. The use of Laplace Equation in the aerodynamic model instead of the Navier-Stokes equation for the potential of the flow rate has made it possible to design an "Ion 3D" tool, which reduces the time of implementation of one scenario from several hours to 7 seconds. Modeling of the propagation of air ions of both polarities in the room under different initial conditions was carried out. Two-dimensional and three-dimensional models with their visualization was implemented. The peculiarity of the resulting models is that they make it possible to determine the concentrations of air ions in any section of the room by three coordinates. Given this, the rapid selection of the variants of the source data makes it possible to achieve the normative values of concentrations of air ions in the area of breathing – exceeding 500 cm-3 of each polarity. Simulation makes it possible to design a room in which, under the condition of artificial ionization of air, the concentrations of air ions close to the optimal values of 3000–5000 cm-3 are provided
- Open Access
- 30 June 2023
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 3 (10 (123)) , 23-29
Determining the efficiency of using led sources of ultraviolet radiation for ionization and disinfection of room air
This paper reports a study into the possibility of using LED systems of ultraviolet radiation for air ionization and disinfection of air and indoor surfaces in the presence of people. It has been established that UV LED lamps with 120° opening angles have parameters under which radiation intensity does not exceed 30 J/m2 at distances of 2 meters. Based on experimental data, a methodology for designing the placement of lamps in the room was devised, which meets the requirements of the SBM-2015 standard and the European Directive 2006/25/EU. The use of LED emitters with a total intensity of up to 25 J/m2 increases the concentration of aero ions. The background concentrations were 140‒180 cm-3 (positive) and 160‒190 cm-3 (negative). The minimum permissible level is 500 cm-3. As a result of irradiation, the concentrations were 1100‒1460 cm-3 (positive) and 1260‒1470 cm-3 (negative). The influence of the recirculator-air purifier on the concentration of aero ions has not been established. The ionization process began immediately after turning on the irradiation systems in the entire volume of the premises (4‒5 meters from the source). The dynamic equilibrium of aero ion concentrations was established within 10‒15 minutes after the irradiation was switched on. The presence of a large number of people (up to 0.97 m2 per person) did not affect the concentration of aero ions. Under the combined effect of ultraviolet radiation and a recirculator-air purifier, the number of mold fungi colonies decreased by 20 times. Under the influence of only ultraviolet radiation – by 2.3 times. The decrease in the number of microbes under the combined effect was 1.6 times, and under the effect of only ultraviolet radiation – 2.8 times
- 30 June 2023
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 3 (10 (123)) , 23-29
Open AccessDetermining the efficiency of using led sources of ultraviolet radiation for ionization and disinfection of room air
This paper reports a study into the possibility of using LED systems of ultraviolet radiation for air ionization and disinfection of air and indoor surfaces in the presence of people. It has been established that UV LED lamps with 120° opening angles have parameters under which radiation intensity does not exceed 30 J/m2 at distances of 2 meters. Based on experimental data, a methodology for designing the placement of lamps in the room was devised, which meets the requirements of the SBM-2015 standard and the European Directive 2006/25/EU. The use of LED emitters with a total intensity of up to 25 J/m2 increases the concentration of aero ions. The background concentrations were 140‒180 cm-3 (positive) and 160‒190 cm-3 (negative). The minimum permissible level is 500 cm-3. As a result of irradiation, the concentrations were 1100‒1460 cm-3 (positive) and 1260‒1470 cm-3 (negative). The influence of the recirculator-air purifier on the concentration of aero ions has not been established. The ionization process began immediately after turning on the irradiation systems in the entire volume of the premises (4‒5 meters from the source). The dynamic equilibrium of aero ion concentrations was established within 10‒15 minutes after the irradiation was switched on. The presence of a large number of people (up to 0.97 m2 per person) did not affect the concentration of aero ions. Under the combined effect of ultraviolet radiation and a recirculator-air purifier, the number of mold fungi colonies decreased by 20 times. Under the influence of only ultraviolet radiation – by 2.3 times. The decrease in the number of microbes under the combined effect was 1.6 times, and under the effect of only ultraviolet radiation – 2.8 times
- Open Access
- 26 June 2023
- Published by Kyiv National University of Construction and Architecture in Strength of Materials and Theory of Structures
- No. 110,p. 245-255
Methodological Foundations Protective Structures Development for Shielding Electromagnetic and Acoustic Fields
In many cases the simultaneous protection against electromagnetic and acoustic fields of wide frequency ranges is required. The complexity of such a task lies in the impossibility of significantly reducing low-frequency sound levels with traditional sound-absorbing materials, as well as the different requirements for materials that shield low-frequency and high-frequency electromagnetic fields. It is proposed to solve this problem by creating a two-layer structure, the front surface of which is solid, and the inner surface is perforated. The front panel can be made of non-conductive material. It is a variant of the Bekeshi panel and is mainly intended to reduce the level of low-frequency sound of a certain frequency with high amplitude. The perforation of the internal (metal) panel is chosen based on the need to provide shielding of electromagnetic and acoustic fields of certain frequencies or frequency bands. A calculator is provided for calculating the required panel parameters (linear dimensions, thickness, hole diameters, their number per unit of surface area). It is advisable to fill the space between the panels with a sound-absorbing material, for example, granulated polystyrene. It provides sound absorption of medium and high frequencies and makes the design broadband. The use of ferromagnetic material of the inner panel provides protection against the magnetic component of the ultra-low frequency electromagnetic field (mainly industrial). The perforation of the panel is calculated based on the waveguide theory of high-frequency electromagnetic waves. The results of tests of the effectiveness of facing metal-polymer material in the form of tiles are presented. The performance of the material is satisfactory for most industrial and domestic conditions. Determination of the mechanical properties of the material (Young's modulus, shear modulus and Poisson's ratio) showed that it is not inferior to known materials even with a large content of shielding substance. In order to rationalize the design of the structure, a priority factor and frequency (frequency band) is selected on the basis of live measurements of the electromagnetic and acoustic spectra. It is shown that the calculations have large volumes, and the solution of two-factor optimization problems is not always possible. Appropriate creation of application software to simplify the process of designing protective structures and rationalizing panel parameters based on the principles of reasonable sufficiency.
- 26 June 2023
- Published by Kyiv National University of Construction and Architecture in Strength of Materials and Theory of Structures
- No. 110,p. 245-255
Open AccessMethodological Foundations Protective Structures Development for Shielding Electromagnetic and Acoustic Fields
In many cases the simultaneous protection against electromagnetic and acoustic fields of wide frequency ranges is required. The complexity of such a task lies in the impossibility of significantly reducing low-frequency sound levels with traditional sound-absorbing materials, as well as the different requirements for materials that shield low-frequency and high-frequency electromagnetic fields. It is proposed to solve this problem by creating a two-layer structure, the front surface of which is solid, and the inner surface is perforated. The front panel can be made of non-conductive material. It is a variant of the Bekeshi panel and is mainly intended to reduce the level of low-frequency sound of a certain frequency with high amplitude. The perforation of the internal (metal) panel is chosen based on the need to provide shielding of electromagnetic and acoustic fields of certain frequencies or frequency bands. A calculator is provided for calculating the required panel parameters (linear dimensions, thickness, hole diameters, their number per unit of surface area). It is advisable to fill the space between the panels with a sound-absorbing material, for example, granulated polystyrene. It provides sound absorption of medium and high frequencies and makes the design broadband. The use of ferromagnetic material of the inner panel provides protection against the magnetic component of the ultra-low frequency electromagnetic field (mainly industrial). The perforation of the panel is calculated based on the waveguide theory of high-frequency electromagnetic waves. The results of tests of the effectiveness of facing metal-polymer material in the form of tiles are presented. The performance of the material is satisfactory for most industrial and domestic conditions. Determination of the mechanical properties of the material (Young's modulus, shear modulus and Poisson's ratio) showed that it is not inferior to known materials even with a large content of shielding substance. In order to rationalize the design of the structure, a priority factor and frequency (frequency band) is selected on the basis of live measurements of the electromagnetic and acoustic spectra. It is shown that the calculations have large volumes, and the solution of two-factor optimization problems is not always possible. Appropriate creation of application software to simplify the process of designing protective structures and rationalizing panel parameters based on the principles of reasonable sufficiency.